| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.1 LAccepted-AOC | L1 | Accepted-AOC BEING L1 AND REASONABLE | |
| 2 | L2₹45.6 L+₹42,320 (0.94%)Rejected-AOC AWADHI ROAD ADAJAN 1ST 102 DABKA NO 1 1 6 4 C 4TH FLOOR | GANDHINAGAR | L2 | Rejected-AOC NOT BEING L1 | |
| 3 | L3₹49.8 L+₹4.6 L (10.2%)Rejected-AOC A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | L3 | Rejected-AOC NOT BEING L1 | |
| 4 | L4₹56.5 L+₹11.3 L (25.0%)Rejected-AOC | L4 | Rejected-AOC NOT BEING L1 | |
| 5 | Rejected-Technical MUSTKIL 47 KHASRA NO 4 1 SIKRI PIYALA ROAD VILL SIKRI BALLABGARH FARIDABAD HARYANA 121004 | FARIDABAD | HARYANA | 121004 | - | Rejected-Technical DOCUMENT NOT IN ORDER |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
16 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M RR HOSPITAL
GE E/M RR HOSPITAL, RAO TULA RAM MARG DELHI CANTT-10
CA NO GE/H-53/2021-22 NAME OF WORK COMPREHENSIVE MAINTENANCE OF MODULAR OT OF CTVS CENTRE AND OTHER MISC WORKS UNDER GE E M RR DELHI CANTT-10
2022_MES_508291_3
GE/H-53/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE E/M RR HOSPITAL
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE E/M RR HOSPITAL
₹83,000
Yes
7 Jul 2022
25 Apr 2022
18 May 2022
25 Apr 2022
16 May 2022
2 May 2022
60 days
Amount
Comprehensive Maintenance of Modular OT- 04 Nos comprising of Ceiling Mounted Pendant -08, Surgeon control panel – 04 Nos, Hatch Box - 04 Nos, X-Ray View Box- 04 Nos, Scrub Sink- 04 Nos Laminar Diffuser Cloth and Automatic Sliding Door- 08 Nos by employing 01 technician having qualification of ITI in electrical/electronics engineering with adequate experience and 01 Helper in the general shift from 0900 hrs to 1700 hrs including Sunday and holiday to make the system functional in installed at CTVS AHRR Notes : (i) Preventive & routine repair/maintenance of Surgeon Control panel. (ii) Preventive & routine repair/maintenance of Ceiling Mounted Pendant. (iii) Preventive & routine repair/maintenance of Hatch Box (iv) Preventive & routine repair/maintenance of X-Ray- View Box (v) Preventive repair & Maintenance of Automatic Sliding Door and Scrub Sink. (vi) Preventive repair & Maintenance of Laminar Diffuser Cloth (vii) Preventive repair & Maintenance of all systems on monthly basis and upkeep of log book. (viii) Attending to all complaints within 24 hours failing which the recovery @ Rs 1000.00 /complaint per day will be effected from contractor's dues (ix) Field Service Reports will be maintained and submitted to the concerned JE(MES) whenever required. (x) All spares parts included in quoted rates including Motor of sliding Door (xi) The complete work is to be carried out through “MOU” between authorized firm which has minimum 3 years experience and must have performance certificate from minimum three hospitals and to be submitted within 15 days of acceptance of tender.
Supply and Installation and Commissioning of 2.00 mm thick CONDUCTIVE ESD tiles of size 615 mm x 615mm as per EN 427.(Imported) The tiles are manufactured from PVC chips coated with a conductive substance. The tiles will offer guarantee a longlife conductivity independently from humidity and temperature. Tiles will be highly compressed with a compact surface. These conductive tiles will be completly free from volatile antistatic chemicals, and ensures a permanent and stable conductive performance of the floor over its entire life time. For cleanroom application tiles will satisfy the strictest requirements for particle release behaviour, helping to reduce any threat of contamination certified by Fraunhofer IPA Institute in Germany. The compact, pore-free surface will be unfriendly to bacteria and moulds to maintain highest standards of hygiene. The seams between the tiles shall be hot welded using the same base material of tiles so that a true material cohesion between the tiles can be produced. The welding / seaming shall be done using hot air welding machine. The Electrical Resistance offered by the tiles is as per IEC 61340-4-1, EN 1081(100v) ANSI/ESD 7.1. The laying of Copper tape and conductive adhesive has to be laid before the tiles.
Supply and installation of repair work two primer coat alongwith two coats of antibacterial & antifungal paint coating system on old panel wall or steel panel which protects against the growth of microorganism, such as mould, fungi, yeast and bacteria on its surface. Meets with fire safety norms BS-476 part 7 class 1, Impact resistancy level as per BS3900(E3) TB 24/S withstand 5 mm along with Chemical resistancy standard BS standards for acids and alkalies incl nitric acid and caustic soda test. TB 6/S resistance to phosphine TB 100/s equivalent to a minimum dry film thickness of 300 to 600 microns. Proper scrubbing of walls should be done before applying the coat.
Supply and fix environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD 4X1 LEDs panel of 36 Watt as light source, suitable for Armstrong/Grid ceiling.
Supply and fix smart surgeon PLC based electronic control panel of size not less than 32 inches mounted flush in the theatre wall comprising of the following features all as specified : - (a) Real time clock (b) Elapsed Clock (c) Hands free Telephone (d) audio alarm (e) temp and humidity indication (f) 6-Medical gas alarm (g) hepa filter status indicator (h) Lighting control (i) Differential pressure (j) Ambient pressure (k) OT pressure (l) OT integration capability (m) music player (n) startup logo (o) Runtime logo . Control: PLC Based (i) Power Requirement : AC - 100-240 V, 50/60 Hz (ii) Power Consumption : 45 Watt (iii) Boot Time: 10-30 Sec, Refresh Rate: 90 Hz (iv) OS: PIECO Kore 3.6 (LINUX) with Crash Protection (v) Processor: Broad com Quad core ARMv8 CPU (High Speed) (vi) Screen Size : 20/24/32/40 Inches Brightness: 400 cd/m2 (vii) Display: HD, LED Type, Infrared based high durability Touch Screen, Contrast Ratio: 3500:01:00 (Static) (viii) Heat Emission: Very Low Fan Less Operation Note: (i) Rates shall include the cost of wiring for control panel and for sensors. No extra payment shall be made for such works. (ii) After fixing of control panel surface shall be make good by the contractor. No extra payment shall be made.
Supply and fixing twin plate X- ray -viewing LCD Screen of size 862X562 mm (Approx) designed to provide a high level of control luminance flicker, recessed in the wall ( Dimming range 3-100%)., illuminated by high frequency florescent lamps, controlled by dimming ballast complete all as specified and directed by Engr-in-Charge.
siddharthenterprises
R D ENTERPRISES
PD SHARMA AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .