| Sl No | Description | Qty | Unit | Uma engineers L3 | M/S KAPIL CONSTRUCTION CO L2 | M/S Rakesh Verma L4 | BABA DEVELOPERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Testing /Checking of serviceable /unserviceable solar heating system device complete incoming /outlet cold /hot water supply system like GI pipes ,gate valves, ,water storage tank. Heat exchanger tank,thermostate / heating element ,power supply backup ,solar plate ,glass wool ,steel structure mounting system ,pcc work, aluminium cladding material etc complete all as specified and as directed. Note : The unsv items /parts etc shall be paid and measured separately under respective items . | 70 | Each Job | 600 ₹42,000 | 250 ₹17,500 | 500 ₹35,000 | 200 ₹14,000 |
| 2.00 | Disconnecting and taking up or down old existing steel tubing/PPR pipe 20 mm bore and connections of any description/ grade and in any position from trenches / walls / floors/ roof etc including connected fittings/accessories and fixtures complete all as specified and as directed | 550 | RM | 20 ₹11,000 | 10 ₹5,500 | 10 ₹5,500 | 5 ₹2,750 |
| 3.00 | Description all as per item No 2 above but 25 mm bore pipe complete all as specified and as directed | 500 | RM | 25 ₹12,500 | 10 ₹5,000 | 10 ₹5,000 | 5 ₹2,500 |
| 4.00 | Description all as per item No 2 above but 32 mm bore pipe complete all as specified and as directed | 200 | RM | 30 ₹6,000 | 12 ₹2,400 | 10 ₹2,000 | 5 ₹1,000 |
| 5.00 | Description all as per item No 2 above but 40 mm bore pipe complete all as specified and as directed | 148 | RM | 50 ₹7,400 | 15 ₹2,220 | 10 ₹1,480 | 5 ₹740 |
| 6.00 | S&F 20 mm bore medium grade (ISI Marked) 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for cold water supply including all PP-R plain & brass threaded polypropylene random with and including all fittings and fixture (ISI Marked) such as TEE, elbow, reducer, union, sockets etc fittings fixed complete to walls, ceilings or in floors etc complete all as specified and as directed | 550 | RM | 125 ₹68,750 | 108 ₹59,400 | 85 ₹46,750 | 105 ₹57,750 |
| 7.00 | S&F 25 mm bore medium grade (ISI Marked) 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for cold water supply including all PP-R plain & brass threaded polypropylene random with and including all fittings and fixture (ISI Marked) such as TEE, elbow, reducer, union, sockets etc fittings fixed complete to walls, ceilings or in floors etc complete all as specified and as directed | 500 | RM | 150 ₹75,000 | 118 ₹59,000 | 117 ₹58,500 | 120 ₹60,000 |
| 8.00 | S&F 32 mm bore medium grade (ISI Marked) Hot water pipe duly insulated with glass wool and aluminium cladding bore Galvanised iron tubing with and including all fittings and fixture (ISI Marked) such as TEE, elbow, reducer, union, sockets etc and fixed on roof top walls and floors complete all as specified and as directed | 200 | RM | 450 ₹90,000 | 368 ₹73,600 | 187 ₹37,400 | 300 ₹60,000 |
| 9.00 | S&F 40 mm bore medium grade (ISI Marked) Hot water pipe duly insulated with glass wool and aluminium cladding bore Galvanised iron tubing with and including all fittings and fixture (ISI Marked) such as TEE, elbow, reducer, union, sockets etc and fixed on roof top walls and floors complete all as specified and as directed | 148 | RM | 600 ₹88,800 | 444 ₹65,712 | 303 ₹44,844 | 430 ₹63,640 |
| 10.00 | Disconnecting and taking up or down existing unserviceable rotational moulded polyethylene water storage tank of any capacity and description complete all as specified and as directed | 9 | Each | 100 ₹900 | 50 ₹450 | 100 ₹900 | 100 ₹900 |
Updated dates
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
27 Dec 2025, 6:00 pmClosed
GE(AF) ADM AREA
GE (AF) ADM AREA GWALIOR - 474020
REPAIR/REPLACEMENT AND ROUTINE MAINTENANCE OF SOLAR WATER HEATING SYSTEM AND OTHER RELATED ACCESSORIES AT AF STN GWALIOR
2025_MES_741248_1
8543/E8
Open Tender
Civil Works
210 days
GE (AF) ADM AREA GWALIOR
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) ADM AREA
₹50,000
Yes
25 Feb 2026
24 Nov 2025
1 Jan 2026
24 Nov 2025
27 Dec 2025
8 Dec 2025
Amount
Testing /Checking of serviceable /unserviceable solar heating system device complete incoming /outlet cold /hot water supply system like GI pipes ,gate valves, ,water storage tank. Heat exchanger tank,thermostate / heating element ,power supply backup ,solar plate ,glass wool ,steel structure mounting system ,pcc work, aluminium cladding material etc complete all as specified and as directed. Note : The unsv items /parts etc shall be paid and measured separately under respective items .
Disconnecting and taking up or down old existing steel tubing/PPR pipe 20 mm bore and connections of any description/ grade and in any position from trenches / walls / floors/ roof etc including connected fittings/accessories and fixtures complete all as specified and as directed
Description all as per item No 2 above but 25 mm bore pipe complete all as specified and as directed
Description all as per item No 2 above but 32 mm bore pipe complete all as specified and as directed
Description all as per item No 2 above but 40 mm bore pipe complete all as specified and as directed
S&F 20 mm bore medium grade (ISI Marked) 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for cold water supply including all PP-R plain & brass threaded polypropylene random with and including all fittings and fixture (ISI Marked) such as TEE, elbow, reducer, union, sockets etc fittings fixed complete to walls, ceilings or in floors etc complete all as specified and as directed
S&F 25 mm bore medium grade (ISI Marked) 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for cold water supply including all PP-R plain & brass threaded polypropylene random with and including all fittings and fixture (ISI Marked) such as TEE, elbow, reducer, union, sockets etc fittings fixed complete to walls, ceilings or in floors etc complete all as specified and as directed
S&F 32 mm bore medium grade (ISI Marked) Hot water pipe duly insulated with glass wool and aluminium cladding bore Galvanised iron tubing with and including all fittings and fixture (ISI Marked) such as TEE, elbow, reducer, union, sockets etc and fixed on roof top walls and floors complete all as specified and as directed
S&F 40 mm bore medium grade (ISI Marked) Hot water pipe duly insulated with glass wool and aluminium cladding bore Galvanised iron tubing with and including all fittings and fixture (ISI Marked) such as TEE, elbow, reducer, union, sockets etc and fixed on roof top walls and floors complete all as specified and as directed
Disconnecting and taking up or down existing unserviceable rotational moulded polyethylene water storage tank of any capacity and description complete all as specified and as directed
Supply and fixing Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified of capacity 1000 Ltrs, triple layer construction, ISI marked including GI pipe 20mm bore medium grade, over flow pipe 450mm long and waste water pipe 600mm long with including all fitting complete all as specified and as directed
Supply and fixing Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified of capacity 500 Ltrs, triple layer construction, ISI marked including GI pipe 20mm bore medium grade, over flow pipe 450mm long and waste water pipe 600mm long with including all fitting complete all as specified and as directed
Disconnecting and taking up or down existing unserviceable solar hot water tank with heat exchanger, of any description Supply and fixing of solar hot water tank with heat exchanger complete of 1000 Ltrs capacity having 100 mm rockwool insulation including all inlet out let connection, insulation and aluminium cladding etc complete all as specified and as directed. Note:Ser no. 01 to 13. NOTE - 1) Proper care shall be take while repairing the solar plant and ensure No damage to the water proofing of the external roof shall be occured. 2)Making good to any damage shall be done by the contractor without any extra cost till satisfactory checking of water roof leakage 3). Materials approved as per sample to be reached within 10 days of date of commencement of work for smooth seasonal functioning of solar water Heater. 4). Penalty of Rs 1000/ to be imposed on complaint found unattended by the contractor. 3.Contractor to deploy skilled manpower for specified jobs. 5). The installations of heat exchanger unit, solar flat plate collector and steel structure shall be in presence of Experts/OEM to avoid any damage of equipment due to heavy wind pressure
Taking down unserviceable heating element / thermostat from the solar water heating system of any size any capacity and any shape complete all as specified and as directed
S&F of heating element 2 KW 230 Volt single phase suitable for solar water heating system complete and including proper dressing of wire by providing suitable flexible conduct all as specified and as directed
S & F of thermostat auto reset 230 Volt 50 Hz single phase suitable for solar water heating system complete and including proper dressing of wire by providing suitable flexible conduct all as specified and as directed
Disconnecting & taking out existing unserviceable 15 mm bore Fancy type Chromium plated bib taps in any position complete all as specified and as directed
S & F of 15 mm bore Fancy type Chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule. complete all as specified and as directed
Taking down unserviceable solar water heater heat exchanger flat plate collector panel from the roof with and including taking out or dismantling of the water supply connection without any damage to the serviceable fitting and fixture complete all as specified and as directed. Note : 1) Proper care shall be take while repairing the solar plant and ensure No damage to the water proofing of the external roof.
Supply and fixing of solar flat plate collector complete of size 2.01 Sqm ( 1992x1090x94mm size) complete all as specified and as directed
Taking down unserviceable insulating glass wool and Supply and fixing of insulating glass wool to insulate the solar water heating tanks or pipe line etc complete all as specified and as directed
M&L for servicing of hot water tank with and including of descaling of the tank with descaling solution and removing all scaling material and deposited at a distance not less than 100 mtr from the site including cleaning of solar flat plate collector complete all as specified and as directed
Disconnecting & taking out existing unserviceable float valve assembly 20mm bore of any description and in any position complete all as specified and as directed
Supply, fixing, jointing and testing of 20mm bore, ball brass valve, high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed
Disconnecting and taking down old existing unserviceable aluminium foil cladding of any description and in any position and Supply and fixing of aluminium foil cladding of thickness 0.63mm complete all as specified and as directed
Disconnecting & taking out old existing unserviceable temperature meter of any description and in any position and Supply and fixing of new temperature meter, 0-100 ºC range, dial type suitable for 15mm GI pipe including all necessary fittings complete all as specified and as directed
Opening of existing aluminium cladding from tank ,cleaning and stacking the same for reuse ,taking out glass wool and repairing the stainless steel tank and repairing the leakage by means of TIG welding as approved ,refilling of glass wool ,aluminium cladding by using old aluminium sheet complete all as specified and as directed. Note:- Existing glass wool & aluminium sheet shall be reused, New glass wool & aluminium sheet if required shall be measured and paid for separately under appropriate item of this Sch as ‘Supply only’.
Disconnecting & taking up or down unserviceable sub main wiring of aluminium/Copper conductor with two run of single core cable and one run of single core earth cable of of size 2.5 Sqmm 1100 Volts, & in any position including taking out existing conduits of any description and making good the disturbed surfaces to the existing surfaces complete all as specified and as directed. Note : 1) Proper care shall be take while repairing the solar plant and ensure No damage to the water proofing of the external roof.
M&L for surface/concealed sub main wiring as required with two single core FR PVC insulated and unsheathed copper stranded conductor of size 2.5 Sqmm 1100 Volts and one run of copper stranded conductor of size 2.5 Sqmm for continuous earthing drawn in rigid non metallic PVC conduit pipe ISI marked of size not less than 20 mm Dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed. Note : 1) Proper care shall be take while repairing the solar plant and ensure No damage to the water proofing of the external roof.
Disconnecting & taking up or down unserviceable sub main wiring of aluminium/Copper conductor with two run of single core cable and one run of single core earth cable of of size 4 Sqmm 1100 Volts, & in any position including taking out existing conduits of any description and making good the disturbed surfaces to the existing surfaces complete all as specified and as directed. Note : 1) Proper care shall be take while repairing the solar plant and ensure No damage to the water proofing of the external roof.
M&L for surface/concealed sub main wiring as required with two single core FR PVC insulated and unsheathed copper stranded conductor of size 4 Sqmm 1100 Volts and one run of copper stranded conductor of size 4 Sqmm for continuous earthing drawn in rigid non metallic PVC conduit pipe ISI marked of size not less than 20 mm Dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed. Note : 1) Proper care shall be take while repairing the solar plant and ensure No damage to the water proofing of the external roof.
Disconnecting & taking up or down unserviceable sub main wiring of aluminium/Copper conductor with two run of single core cable and one run of single core earth cable of any description, of size 6.0 Sqmm of voltage rating up to and including 1100 Volts grade taking out existing conduits of any description and making good the disturbed surfaces to the existing surfaces complete all as specified and as directed. Note : 1) Proper care shall be take while repairing the solar plant and ensure No damage to the water proofing of the external roof.
Taking down old unserviceable and rusted supporting structure of panel/PVC TANKS of any type and in any position and Supply and fixing supporting structure made of mild steel supports epoxy coated including nuts and bolts etc as required complete all as specified and as directed. Note: 1) Proper care shall be take while repairing the solar plant and ensure No damage to the water proofing of the external roof shall be occured. 2)Making good to any damage shall be done by the contractor without any extra cost till satisfactory checking of water roof leakage.
Taking down broken/cracked glass of solar panel complete all as specified and as directed
Supply and fixing of toughened glass 4 mm thick size suitable for 1992x1090 / 2030X1030mm size solar panel complete all as specified and as directed Note: 1) Proper care shall be take while repairing the solar plant and ensure No damage to the water proofing of the external roof. 2)Making good to any damage shall be done by the contractor with no extra cost till satisfactory checking of water roof leakage.
Material & labour for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in PCC block for fixing of supporting structure complete all as specified and as directed
Material & labour for plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in copping including necessary form work or in any situation all as specified and directed.
Disconnecting and taking up or down old existing of 50mm gun metal, globe/gate valve with brass spindle iron wheel head, both ends screwed for iron pipe complete all as specified and directed.
Description all as per item No 39 above but 40mm bore complete all as specified and as directed
Description all as per item No 39 above but 25mm bore complete all as specified and as directed
Description all as per item No 39 above but 20mm bore complete all as specified and as directed
Supply, fixing, jointing and testing of , 50mm bore, ISI Marked, of approved quality, gun metal, globe/gate valve with brass spindle iron wheel head, both ends screwed for iron pipe complete all as specified and directed.
Description all as per item No 43 above but 40mm bore complete all as specified and as directed
Description all as per item No 43 above but 25mm bore complete all as specified and as directed
Description all as per item No 43 above but 20mm bore complete all as specified and as directed
Disconnecting and taking up or down existing unserviceable solar hot water tank with heat exchanger, of any description Supply and fixing of solar hot water tank with heat exchanger complete of 500 Ltrs capacity having 100 mm rockwool insulation including all inlet out let connection, insulation and aluminium cladding etc complete all as specified and as directed
Material and labour for cast iron/ductile iron specials/fittings such as bend, tee, socket, collar Reducer, Tail Pieces etc. suitable for spigot and socketed/ flanged end pipe up to 150 mm bore complete all as specified and directed.
Disconnecting and taking up or down existing unserviceable Rubber hose of any description and Supply and fixing of Rubber hose 32/40 mm Dia of size ISI marked complete all as specified and as directed
Disconnecting and taking up or down existing unserviceable Coupler of any description and Supply and fixing of Coupler suitable for solar heat plate collector ISI marked complete all as specified and as directed
Disconnecting and taking up or down existing unserviceable MCB SP of MCB SP 6 to 32 Amp 240 volt "c" series complete all as specified and as directed
Supply and fixing of AMP rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 6 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed
Disconnecting and taking up or down existing unserviceable MCB DB SPN of any description wooden plank/grouted on wall , sheet metal enclosure MCB DB SPN 8 ways,240 V single door complete all as specified and as directed
Supply and fixing of wooden plank/grouted on wall , sheet metal enclosure MCB DB SPN 8 ways,240 V single door complete all as specified and as directed. .
M/S KAPIL CONSTRUCTION CO (BID ID -3509426)
Uma engineers (BID ID -3504836)
M/S Rakesh Verma (BID ID -3509583)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
TENDER8543.pdf
Tender Documents • 0.79 MB
BOQ_830010.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid