Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹4.9 L
EMD Value
₹9,885
Closing Date
26 Mar 2022, 1:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (E)
BSNL, Electrical Division, GPO Compound, Meerut Cantt.
Shifting of Electro Mechanical Services from T.E. L-Block, Shastri Nagar to L-261, Shastri Nagar ,Meerut.
2022_BSNL_677219_1
29/NIT/EE(E)/BSNL/ED/MT/21-22
Open Tender
Non-Explosive
Item Rate
60 days
Meerut
Please refer Tender documents.
5 documents required · 5 mandatory
₹590
Accounts Officer Cash, BSNL O/o GMTD, Meerut
₹9,885
16 Apr 2022
5 Mar 2022
28 Mar 2022
5 Mar 2022
26 Mar 2022
5 Mar 2022
90 days
Dismantling of existing copper wiring, fittings, fans, conduit pipe, changeover switch, TPN DB and power cable, switch board, Electrical panel, Power room panel, Fire panel & fire detection system, cabling i/c repairing & painting of wall & roof with desired colours etc as reqd.
Shifting (Loading-Unloading) of all dismantled material i.e. copper wiring, fittings, fans, conduit pipe, power cable, switch board, distribution panel, Fire panel and detectors etc from T. E. Building L-Block, Shastri Nagar to new location at L-261, Shastri Nagar (Meerut) / Store at GPO Compond.
Dismantling of 3 x 1.5 TR Split AC Unit and re-insatllation at new location and servicing etc complete as required
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) GROUP-B
S/fixing of following sizes of steel conduit a/w accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as reqd. (a) 20 mm
S/L of following size of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel /PVC conduit as reqd. (a) 2 x 1.5 sq. mm
(b) 3 x 1.5 sq. mm
(c) 4 x 1.5 sq. mm
(d) 3 x 2.5 sq. mm
(e) 3 x 4.0 sq. mm
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
S/Fixing 20 watt LED 4 feet tube fitting suitable for single phase, 230 volts AC supply system connection etc complete as required.(M/s Cromption/ Philips or S.S make)
Supplying and fixing 2 waysheet steel enclosure dust protected, duly powder painted with 32 amps "C" curve, SP&N MCB on surface or in recess complete with connections, testing and commissioning etc. as required. (M/s legrand or SS Make)
S/Fixing following way distribution board made of sheet steel on surface/recess having IP 43 protection double door complete with all standard accessories, inter connection, i/c painting earthing etc. as required. (M/s Legrand or SS make) (a) 4 Way. TP & N DB
S/Fixing of following rating MCB/Isolator in the existing MCB DB complete with connection, testing & commissioning etc. as required. (a) 6-32 Amp SP MCB
(b) 63 Amp four pole Isolator
Dismentalling of 6-32 Amp. MCB from existing panel & fixing the same in the existing MCB DB complete with connection, testing & commissioning etc. as required.
Supply & Laying on surface of 4 x 16 Sq.mm PVC insulated and PVC sheathed/ XLPE Alum. conductor cable of 1.1 KV grade.(M/s Havells / Finolex make)
S/M end termination with brass compression gland and aluminum luges for the following size PVC insulated and sheathed aluminum conductor cable of 1.1 KV grade etc. as reqd. (a) 4 x 16 Sq. mm
Supplying and charging of refrigerant Gas R-22 in the existing split AC units etc. as required.
Pressure testing with nitrogen after leakage detection and removal including vaccmization etc. complete with connections, testing and commissioning etc. as required.
Supply & Fixing of copper refrigerant pipe lines as suction and discharge length for 1.5 TR split A/C unit of i/c foam insulation etc. complete as required.
Supply & fixing of 32 mm dia heavy duty C.P.V.C drain Pipe i/c accessories from unit to suitable distance for drain etc. complete as required
Supplying and drawing 3 core 2.5 Sqmm multi core copper conductor PVC insulated FR Power cable for electrical connection etc. as reqd.
Supply & fixing of powder coated prefabricated mounting stand for out door unit made out of 18 SWG Powder coated M.s Sheet and perforated angle iron of suitable size i/c cutting, welding, painting and grouting etc. complete as reqd.( M/s Hitachi/L.G. or S.S. make)
I.T.C of eisting 04 Zone dismantling and existing fire alarm wall mounted main control i/c repairing, servicing etc as reqd.
S.I.T.C of 12 Volt, 42 AH SMF battery complete as required.
I.T.C of optical detectors dismantlled from old TE Bldg. i/c R.I etc. complete as required.
I.T.C of hooters dismantlled from old TE Bldg. i/c R.I etc. complete as required.
S.I.T.C of 63 Amp four pole 'On Load' change over switch in Sheet steel enclosure i/c making connection etc. as reqd. (M/s L&T or SS make)
S/Fixing of 63Amp HRC Fuse suitable for FN 63 Amp existing TPN in L T Panel etc. as required. (M/s L&T or SS make)
S/Fixing of LED type Indication lamp in existing L T Panel etc. as required.( M/s L&T or SS make) a) LED Indication Lamp Blue
b) LED Indication Lamp Red / Yellow
I.T.C of Electrical panel and transportation from T.E. Aminagar Sarai to L-261 Shastri Nagar, Meerut i/c loading unloading and lifting to second floor etc complete as required.
Dismantling of existing power plant and battery set at Old T.E L-Block Shastri Nagar, Meerut complete as required.
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm Copper strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm Copper strip on surface or in recess for connections etc. as required
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground / surface as required.
Dismantlling of existing 1 x 25 KVA EA set along with sound proof enlousre etc. complete as required.
Loading, unloading, transportation of existing 1 x 25 KVA DG set from old location to new location and shifting to the roof of second floor at new location complete as reqd.( the work will be carred out with manual labour as well as hydraulic crane)
Installation of existing 1 x 25 KVA DG set at new location i/c connection of cable, earthing etc. complete as reqd.
Installation of existing Power room Panel at new location i/c connection of cable etc. complete as reqd.
M/s Mohit Engineers
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .