Directorate of Municipal Administration
SHEKHAR
Eletrical Repairs work At shikaripura TMC office building
DMA/2026-27/EL/WORK_INDENT62514
DMA/2026-27/EL/WORK_INDENT62514
Open
Electrical
Two Tender Document System(Two Cover)
DMA Town Municipal Council Shikaripura
4 documents required · 4 mandatory
Department Registration Details
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing work
List of works for which tenders already submitted
Banker Details
GST
Pwd licence
audited
Pan card
₹500
₹12,500
25 Sept 2026
25 Sept 2026
9 Oct 2026
8 Oct 2026
Eletrical Repairs work At shikaripura TMC office building
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire...
Supply and laying of under floor junction boxes shall be of three-piece construction Base box frame and load plate Base box shall be robust in its construction manufactured from 1.5 mm thick zero span...
Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF scr...
Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS2509with suitable sizebends metal/PVCJunction boxes adhesive paste etc andrunningbeforeconcretingtheslab Theconduitshouldbetiedto...
Supplying and fixing PVC/metal conduit Deep junction box 1.5.3 ---- Condition are Apply As per Bid Document
Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wall ---- Cond...
Supplyingand flushmounting teakwooden boxwithout front plank made of not less than12mthickwood after duegroove cutting finishing with necessary cement plastering complete.1.6.1 12x 12x 3 (300 x 300 x ...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed systemof wiring with specified IS-...
Supplying anddrawing with electrolytic grade flexible copper with low conductor
confirming to IS 8130-1984 and (Virgin) PVC insulation sheathedsuitable forworking voltageupto1100Vas per IS 694:2010 2....
Supplying 6A flush type socket and 6A flush type SP switch either surface /flush mounting in existing gang boxor in 4mm thickplasticsheetandfixingoveraflushmountedwoodenbox and wiring using necessary ...
Supplying and fixing superior quality modular switch mounting oly carbonate plate with necessary supporting back plate with requirednos. ofmachinescrews, boltsnutsetc., completeon
the existing metal/P...
Supplying and fixingo fmodular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.2 6A Two Way Switch ---- Condition are Apply As per Bid Document
Supplyingandfixingof modular switch&connected accessories on existing modular switch plate as per IS 3854 and IS 1293 3.6.10 32A DP Switch ---- Condition are Apply As per Bid Document
Supplying and fixing 32A security and energy savingDP switchwith keytag suitable tooperate on 230 V,50HzAC
supply & completely wired on existing box.4 ---- Condition are Apply As per Bid Document
Supplying wayplasticgangboxandfixingusingnecessary wooden/ rawl/phill plugs and screws 3 12 3 6 to 10 Way Gang Box ---- Condition are Apply As per Bid Document
Supplying and fixing HRC fuse units base on existing switch panel board 5 9 2 32 to 63 A ---- Condition are Apply As per Bid Document
Supplying of on load change over switches 4 poles,AC 23ADuty415V 50Hz,ACSupply. Withall accessories. (SM Enclosure Sheet Metal Execution)) 5.12.1 63 A ---- Condition are Apply As per Bid Document
Supplying and fixingMouldedCase Circuit Breaker (MCCB) over the existingwood/panel boardusing necessary screws, bolts, nuts, necessary phase separators, handle andwiring complete. ProtectionofOverload...
Supplying& fixing miniature circuit breakers on existing MCBdistribution boards using necessary fixing materials and C Type curve indicator ON/OFF, energy cross-3 with Shortcircuitbreaking capacityof1...
Supplying fixing andwiringResidual current circuit breaker (RCCB) 240/450Vupto 300mAsensitivity on existingwood/ panel board. 5 19 1 16A-25A 2 pole ---- Condition are Apply As per Bid Document
Supply and Installation /Fixing /Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid shock proof IP65 (Weather Proof) rust oof dustproof waterproof, corr...
Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220V/50 Hz, Ratedpower input ...
Supplying and fixing PVC/metal conduit Deep junction box 32 mm deep Junction box (PWDSR 2023-24 P.NO 1 I No.1.5.3 VOL6 ---- Condition are Apply As per Bid Document
Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc compl...
Supplying & fixing ofretrofittype-bulb.WwithOPALacrylicdiffusercomprisingof LEDsourcewith CCT6500 degreeK CRI 70 efficacy 80lumenper Wlife 25000 burning hours andCompliancetoIS 10322/IEC60598 LM79&LM8...
Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of sa...
Supplying of recess mounting non integrated type LED down light W luminaire comprising of pressuredecast extruded aluminiumhousing withspring loadedfalseceilingclA LEDof Power/COB with CCT6500degreeK ...
Supplyingof feet PVC Batten with integratedLEDtube W withhigh quality diffuser with Life of 25000 burning hours 70 lumen maintenance with CRI 80. Power Input:220-240V 50/60Hz Power factor 0.9alongwith...
Work of supply, erection and commissioning of indoor upto 250 Amps distribution panel as specified below: Supply, erection and commissioning of Indoor type upto 250 Amps MCCB distribution panel with o...
Supplying fixing andwiringResidual current circuit breaker (RCCB) 240/450Vupto 300mAsensitivity on existingwood/ panel board. 5 19 1 16A-25A 2 pole ---- Condition are Apply As per Bid Document
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Office eletrical.docx
Tender Document • 1.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .