Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.7 LAccepted-Finance 3 147 KPN NAGAR MELTUR DAM 636 401 | SALEM | TAMIL NADU | 636401 | 1 | Accepted-Finance satisfied | |
| 2 | 2₹6.1 L+₹45,162.50 (7.95%)Accepted-Finance 12 144A KPN NAGAR METTUR DAM 636401 | METTUR DAM | SALEM | TAMIL NADU | 636401 | 2 | Accepted-Finance satisfied |
Tender Value
Refer Docs
EMD Value
₹7,200
Closing Date
15 Jun 2022, 2:00 pmClosed
Superintending Engineer /Mechanical-I/MTPS-I
Office of the Superintending Engineer / Mechanical -I Mettur Thermal Power Station- I Mettur Dam-636406
MTPS I BM Unit II Boiler Pressure parts AOH 2022 Removal and refixing of Skin casing sheet and insulation for attending boiler 1st pass water wall tubes and 2nd pass steam cooled wall tube rectification works replacing damaged insulation in boiler
2022_EB_234683_1
CE / MTPS-I / SE / M-I / BM / OT. 139 / 2022-23
Open Tender
Power/Energy Projects/Products
Works
25 days
Mettur Thermal Power Station-I / Mettur Dam
As per the Tender Specifications
4 documents required · 4 mandatory
₹0
₹7,200
Yes
18 Jun 2022
1 Jun 2022
16 Jun 2022
1 Jun 2022
15 Jun 2022
1 Jun 2022
Amount
Charges for removal and refixing the insulation and skin casing sheets to carry out Boiler tubes & fin welding rectification works and reposition the dislodged /damaged insulation and skin casing sheet in Ist & IInd pass Wall tube of Boiler including the charges for transportation of insulation and skin casing sheets, and for necessary scaffolding arrangements.
Charges for removal of worn out/ damaged insulation and Aluminium sheet from Boiler pipe lines.
Charges for cutting of new / old ceramic blanket/wool mattress for required size and fixing on Boiler pipe lines.
Charges for cutting new Aluminium / G.I sheet to required size, bending forming and making locking grooves and Fixing / Repairing, dents removal from released Aluminium/ G.I sheets, fixing on insulation and positioning the sheets intact with suitable fasteners on Boiler pipe lines
Charges for removal and refixing of insulation hood and insulation of the 100/250 size valves for repairing /OH works
Charges for removal and refixing of insulation hood and insulation of the 65/250 size valves for repairing /OH works
Charges for leading, lifting and arranging platform and scaffolding wherever required in the boiler and dismantling after completion of work.
Charges for loading in to tipper and disposing the waste insulation to ear marked area
Scaffolding materials
Fixing screws
Light Resin Bonded wool Mattresses Size 1.62 m X 1.22 m X 60mm thick confirming to IS8183,93.Density : 150 Kg/m3both sides 0.75 inch X 23 SWG G.I wire knitting with machine stitched and Laid in HDPE
T &Ps and consumables
SRP AGENCIES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .