| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹44.9 L+₹1.2 L (2.64%)Rejected-AOC 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | L2 | Rejected-AOC Not Being L1 | |
| 3 | L3₹45.1 L+₹1.4 L (3.12%)Rejected-AOC SR NO 331 2B PLOT NO 43 R H NO 02 BALDEWA RAO BUNGLOW NEWA NMC WATER TANK PATHARDI SHIVAR NASHIK 422 009 INDEX NO E 84CWE AF LOHEGAON PUNE | NASHIK | MAHARASHTRA | 422009 | L3 | Rejected-AOC Not Being L1 | |
| 4 | L4₹45.5 L+₹1.8 L (4.10%)Rejected-AOC | L4 | Rejected-AOC Not Being L1 | |
| 5 | L5₹46.0 L+₹2.3 L (5.17%)Rejected-AOC | L5 | Rejected-AOC Not Being L1 |
| Sl No | Description | Qty | Unit | MAHIMA CONSTRUCTION L2 | SHRI SULAI ELECTRICALS L8 | United Enterprises L5 | M/s.NIKI ENTERPRISES L4 | LOKMANYA ENTERPRISES L7 | SONA LAKSHMI ASSOCIATE L1 | Shree Sai Samarth Enterprises L3 | DIAMOND ENTERPRISES L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for Cutting of branches of trees having girth exceeding 5 cm but not exceeding 20 cm in over head conductor span approximate length 30-40 mtr including disposal of unserviceable material to a distance 100 mtr for removing/ cleaning over head ACSR conductor around 3 mtrs all as directed by the Engineer in charge. Note : T &P for above mentioned work included in quoted rate. | 1,000 | RM | 46 ₹46,000 | 50 ₹50,000 | 33 ₹33,000 | 50 ₹50,000 | 23 ₹23,000 | 20 ₹20,000 | 10 ₹10,000 Lowest | 40 ₹40,000 |
| 2.00 | M&L for in repair of jointing & testing heat shrinkable cable joint kit , straight through , out door type for 1100 volts LT XLPE/PVC insulated cable of aluminium conductor up to 50sqmm 3-1/2 core cable including necessary jointing work all as specified & directed | 15 | Each | 1,450 ₹21,750 | 7,500 ₹1,12,500 | 2,110 ₹31,650 | 1,300 ₹19,500 | 2,500 ₹37,500 | 1,250 ₹18,750 | 1,200 ₹18,000 Lowest | 1,500 ₹22,500 |
| 3.00 | M&L for inrepair for jointing & testing heat shrinkable cable joint kit , end termination , out door type for 1100 volts LT XLPE/PVC insulated cable of aluminium conductor up to 50 sqmm 3-1/2 core cable including necessary jointing work all as specified & directed | 10 | Each | 2,000 ₹20,000 | 5,000 ₹50,000 | 2,650 ₹26,500 | 1,200 ₹12,000 | 2,500 ₹25,000 | 1,150 ₹11,500 Lowest | 1,200 ₹12,000 | 1,500 ₹15,000 |
| 4.00 | M&L inrepair for jointing & testing heat shrinkable cable joint kit , straight through , out door type for 1100 volts LT XLPE/PVC insulated cable of aluminium conductor 50sqmm to 120 sqmm 3.5 core cable including necessary jointing work all as specified & directed | 10 | Each | 1,900 ₹19,000 | 10,000 ₹1,00,000 | 2,800 ₹28,000 | 1,700 ₹17,000 | 2,500 ₹25,000 | 1,750 ₹17,500 | 1,500 ₹15,000 Lowest | 1,500 ₹15,000 Lowest |
| 5.00 | M&L inrepair for jointing & testing heat shrinkable cable joint kit , end termination , out door type for 1100 volts LT XLPE/PVC insulated cable of aluminium conductor 120sqmm to 185sqmm 3.5 core cable including necessary jointing work all as specified & directed | 6 | Each | 2,950 ₹17,700 | 7,000 ₹42,000 | 3,005 ₹18,030 | 2,400 ₹14,400 | 2,500 ₹15,000 | 2,550 ₹15,300 | 4,000 ₹24,000 | 2,000 ₹12,000 Lowest |
| 6.00 | Restringing of existing LT overhead line of copper/ACSR conductor after opening of binding wire from insulator and bringing the sag within limit rebinding the same with insulator with 16 SWG aluminium wire/suitable copper wire all including renewal of jumpers by providing heavy duty alkathine pipe of approved quality, reconnecting the service connections after cleaning the carbon and foreign material complete all as directed. (Note : All the tree branches obstructing to the O.H line shall be trimmed up to 3 mtr away from the O.H line. Unit rate quoted shall be deemed to be inclusive of charges for the trimming of trees.) Note : T &P for above mentioned work included in quoted rate. | 800 | RM | 8 ₹6,400 Lowest | 10 ₹8,000 | 40 ₹32,000 | 100 ₹80,000 | 40 ₹32,000 | 20 ₹16,000 | 10 ₹8,000 | 40 ₹32,000 |
| 7.00 | S& F in repairs pin type porcelain, vitreous, white, brown or green insulator including one mild steel spindle, two galvanised iron washers and one galvanised iron nut 100mm height, 65 mm dia for 1100 volts grade on existing cross arms on LT poles | 6 | Each | 145 ₹870 Lowest | 200 ₹1,200 | 152 ₹912 | 1,000 ₹6,000 | 1,300 ₹7,800 | 200 ₹1,200 | 250 ₹1,500 | 950 ₹5,700 |
| 8.00 | S&F in repairs shackle type porcelain, vitreous white brown or green, insulator for working pressure 6600 volts of 150 mmx 125mm including galvanised mild steel straps of 38x5 mm size 20mm dia bolts, washers & nuts or 50x6 mm size Flat iron D clamp etc on existing cross arms on LT pole all as specified and directed by Engr in charge. | 6 | Each | 145 ₹870 Lowest | 250 ₹1,500 | 152 ₹912 | 430 ₹2,580 | 400 ₹2,400 | 400 ₹2,400 | 300 ₹1,800 | 400 ₹2,400 |
| 9.00 | Excavation in trenches n. exc 1.5 Mtr wide and n. exc 1.5 mtr in depth and getting out in soft soil and taking existing cable taking out old UNSV cable from the trench any size and rating complete all as specified and directed
Note :- Excavation carried out by contractor without damage existing services, if it is any services damage by contractor during excavation of work it will repair/serviceable at site without occurring any extra cost | 510.3 | Cum | 155 ₹79,096.5 | 200 ₹1,02,060 | 210 ₹1,07,163 | 350 ₹1,78,605 | 300 ₹1,53,090 | 168 ₹85,730.4 | 150 ₹76,545 Lowest | 300 ₹1,53,090 |
| 10.00 | Excavation in trenches n. exc 1.5 Mtr wide and n. exc 1.5 mtr in depth and getting out in hard soil. | 145.8 | Cum | 295 ₹43,011 | 500 ₹72,900 | 325 ₹47,385 | 300 ₹43,740 | 310 ₹45,198 | 305 ₹44,469 | 250 ₹36,450 Lowest | 250 ₹36,450 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
20 Dec 2025, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
REPAIR / REPLACEMENT AND MAINT OF LT OVER HEAD LINE, LT CABLE, LT FEEDER PILLAR BOXES AND CONNECTED ITEMS OF VARIOUS LOCATIONS AT 25ED AF DEOLALI
2025_MES_742183_1
8360/E8
Open Tender
Electrical and Maintenance Works
Works
335 days
DEOLALI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹80,000
Yes
18 Apr 2026
29 Nov 2025
22 Dec 2025
30 Nov 2025
20 Dec 2025
13 Dec 2025
Amount
M & L for Cutting of branches of trees having girth exceeding 5 cm but not exceeding 20 cm in over head conductor span approximate length 30-40 mtr including disposal of unserviceable material to a distance 100 mtr for removing/ cleaning over head ACSR conductor around 3 mtrs all as directed by the Engineer in charge. Note : T &P for above mentioned work included in quoted rate.
M&L for in repair of jointing & testing heat shrinkable cable joint kit , straight through , out door type for 1100 volts LT XLPE/PVC insulated cable of aluminium conductor up to 50sqmm 3-1/2 core cable including necessary jointing work all as specified & directed
M&L for inrepair for jointing & testing heat shrinkable cable joint kit , end termination , out door type for 1100 volts LT XLPE/PVC insulated cable of aluminium conductor up to 50 sqmm 3-1/2 core cable including necessary jointing work all as specified & directed
M&L inrepair for jointing & testing heat shrinkable cable joint kit , straight through , out door type for 1100 volts LT XLPE/PVC insulated cable of aluminium conductor 50sqmm to 120 sqmm 3.5 core cable including necessary jointing work all as specified & directed
M&L inrepair for jointing & testing heat shrinkable cable joint kit , end termination , out door type for 1100 volts LT XLPE/PVC insulated cable of aluminium conductor 120sqmm to 185sqmm 3.5 core cable including necessary jointing work all as specified & directed
Restringing of existing LT overhead line of copper/ACSR conductor after opening of binding wire from insulator and bringing the sag within limit rebinding the same with insulator with 16 SWG aluminium wire/suitable copper wire all including renewal of jumpers by providing heavy duty alkathine pipe of approved quality, reconnecting the service connections after cleaning the carbon and foreign material complete all as directed. (Note : All the tree branches obstructing to the O.H line shall be trimmed up to 3 mtr away from the O.H line. Unit rate quoted shall be deemed to be inclusive of charges for the trimming of trees.) Note : T &P for above mentioned work included in quoted rate.
S& F in repairs pin type porcelain, vitreous, white, brown or green insulator including one mild steel spindle, two galvanised iron washers and one galvanised iron nut 100mm height, 65 mm dia for 1100 volts grade on existing cross arms on LT poles
S&F in repairs shackle type porcelain, vitreous white brown or green, insulator for working pressure 6600 volts of 150 mmx 125mm including galvanised mild steel straps of 38x5 mm size 20mm dia bolts, washers & nuts or 50x6 mm size Flat iron D clamp etc on existing cross arms on LT pole all as specified and directed by Engr in charge.
Excavation in trenches n. exc 1.5 Mtr wide and n. exc 1.5 mtr in depth and getting out in soft soil and taking existing cable taking out old UNSV cable from the trench any size and rating complete all as specified and directed Note :- Excavation carried out by contractor without damage existing services, if it is any services damage by contractor during excavation of work it will repair/serviceable at site without occurring any extra cost
Excavation in trenches n. exc 1.5 Mtr wide and n. exc 1.5 mtr in depth and getting out in hard soil.
Returning Filling in including spreading, leveling, watering & well ramming in layers n. exc 25 Cm.
Removing excavated/Surplus soil n exc 50 Mtr & depositing where directed at a level n. exc 1.5 Mtr above the starting point.
M&L in repair for double wall corrugated (DWC) duct (dure guard) as per IS 14930 part II LT UG cable protection including coupler, elbows, T joiints, Bends etc. and test report Make: Dura line/ Gemini/ Rex/Aestral of size 38mm inner dia and 50mm outer dia al as per direted by Engr in charge.
M&L in repair for double wall corrugated (DWC) duct (dure guard) as per IS 14930 part II LT UG cable protection including coupler, elbows, T joiints, Bends etc. and test report Make: Dura line/ Gemini/ Rex/Aestral of size 63mm inner dia and 77mm outer dia al as per direted by Engr in charge.
M&L in repair for double wall corrugated (DWC) duct (dure guard) as per IS 14930 part II LT UG cable protection including coupler, elbows, T joiints, Bends etc. and test report Make: Dura line/ Gemini/ Rex/Aestral of size 95mm inner dia and 110mm outer dia al as per direted by Engr in charge.
Material & labour for laying, fitted on wall plinth with saddle complete in repairs LT XLPE insulated/PVC heavy duty armoured cablle 1100 volts grade stranded aluminium conductor electric cable cross sectional area 25 Sqmm 3.5 Core including necessary connection with provision of lugs & cable gland fixing arrangements all as specified and directed by Engr in charge. (Note for sl no 16 to 20: Cable will be issue by department from MES Ojhar yard, contractor has to arrange the required T&P to load & unload cable drum it at proposed site and the lugs/thimble, cable glands, saddle coupling , insulation tap and other connected items required for requisite connection of the cable. The rates quoted are deemed to be included with ,no claim whatsoever on this account shall entertain)
All as per item above but size 16 Sqmm 4 Core including necessary connection with lugs, cable gland & fixing arrangements all as specified and directed by Engr in charge.
All as per item above but size 10 Sqmm 4 Core including necessary connection with lugs, cable gland & fixing arrangements all as specified and directed by Engr in charge.
All as per item above but size 10 Sqmm 2 Core including necessary connection with lugs, cable gland & fixing arrangements all as specified and directedby Engr in charge.
All as per item above but size 70 Sqmm 3.5 Core including necessary connection with lugs, cable gland & fixing arrangements all as specified and directed by Engr in charge.
Supply and laying in trenches/ducts or passing through pipes multi-stranded aluminium conductor electric cable cross sectional area 50 Sqmm 3.5 Core including necessary connection with lugs, cable gland & fixing arrangements all as specified and directed by Engr in charge.
All as per item above but size 35 Sqmm 3.5 Core including necessary connection with lugs, cable gland & fixing arrangements all as specified and directed.
All as per item above but size 10 Sqmm 2 Core including necessary connection with lugs, cable gland & fixing arrangements all as specified and directed.
All as per item above but size 95 Sqmm 3.5 Core including necessary connection with lugs, cable gland & fixing arrangements all as specified and directed.
All as per item above but size 120 Sqmm 3.5 Core including necessary connection with lugs, cable gland & fixing arrangements all as specified and directed.
All as per item above but size 150 Sqmm 3.5 Core including necessary connection with lugs, cable gland & fixing arrangements all as specified and directed.
All as per item above but size 185 Sqmm 3.5 Core including necessary connection with lugs, cable gland & fixing arrangements all as specified and directed.
S&F in replacement for cable joint termination box PVC body housing 230x185x110 suitable for housing and including 100 amps rated aluminium bus bar,suitable MCB SP, 3 phase, 4 wire system mounted on PVC insulators for one incomming and two out going cable entry space mounted on street light PCC/ tublar pole with 25x3 mm GI clamps with GI nut, bolts washers ,thimble etc & Make: Sintex /C&S/National& double compression gland of Make : Dovel or comet, complete all as specified and directed by Engineer-in-Charge.
M&L for Cable route indicator fabricated from 600x180x40mm Precast RCC/PCC , duly painted with yellow colour synthetic enamel paint complete marking name in black colour using tensils " LT cable/HT cable/HT cable Joint" in letters with suitable visible font including grouted in ground with PCC 1:4:8 type D-2, compete all as specified and directed by Eng- In Charge
M & L in repair for cement concrete (1:3:6 ) type C-1 using 20 mm graded stone aggregate, including weathering, slightly rounded Chamfered angles and throating including necessary form work all as directed .
M & L inrepair for cement concrete (1:4:8 ) type D-2 using 40 mm graded stone aggregate, in foundation all as directed .
Material & labour for carring out fault detection of LT XLPE electrical cable located inside 25 ED station complex through cable fault detector van of MSEDCL (testing division) or equivalent approved vendor,identifing the the fault carring out necessary exacavation using JCB/Manualy for verification of fault& fault confirmation , complete all as specified and directed by Engineer-in-Charge. Note ; If fault not located by the contractor within specified time a recovery of an amount of Rs 5000/- will be recovered per day.
M&L repair for Preparation of old painted surfaces of steel tubular poles,cross arms and painting with two coat of aluminium paint after scrapping old paint marking of pole no number over black back ground with white paint size of letter as directed by Engr-in-Charge all as directed for pole of LT pole up to 9/11 mtr long including marking of pole number. Note:- (i) T&P will be included by firm in quoted rate (ii) Any casualty or injury sustained by the contractor’s workers during the working hours shall be sole liability of the contractor. No claim on this account shall be entertained by the department
M&L inrepair for painting with two coat of cement based paint after scrapping old painted surfaces of concrete poles of height upto 9/11 meters and including marking of poles numbers in white on black background complete all as directed.
M&L inrepair for cross arms, bracings, supports, clamps and back plates fabricated from strucural steel sections including nuts, bolts, washers,welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated, with & inclusive of one coat red oxide primer & one under coat and one finishing coat of synthetic enamel paint after preperation of surfaces all as soecified, as directed by engg in charge.
Supply and errection in position of steel tubular pole swaged complete with cast iron base plate finial taper plug, bolts, nuts, pole caps and screws, top cover all as specified type 410 SP 31 ( 9 mtr long ).The poles shall be painted with two coat of black bituminous paint through internally and externally up to planting depth and balance portion of pole shall be painted with two coats of aluminium paint over a coat of red oxide primer, marking of pole no number over black back ground with white paint size of letter all as specified, as directed by Engr in charge. Note:-Excavation and earth work shall be paid separatly and including taking out old uNSV one by Engr in charge.
S&F in repairs MCCB four pole, 415 Volts, of rating capacity 500 Amps, 50 KA, 50 Hz, ICS=100% ICU with thermal setting adjustable 70-100% of capacity including dismantaling and reconnecting all necessary connections & testing complete by Engr in charge.
S&F in repairs MCCB four pole, 415 Volts, of rating capacity 200 Amps, 36 KA, 50 Hz, ICS=100% ICU with thermal setting adjustable 70-100% of capacity including dismantaling and reconnecting all necessary connections & testing complete.
S&F in repairs MCCB four pole, 415 Volts, of rating capacity 160Amps, 36 KA, 50 Hz ICS=100% ICU with thermal setting adjustable 70-100% of capacity including dismantaling and reconnecting all necessary connections & testing complete.
S&F in repairs on load change over switch of capacity 200 Amps in sheet steel enclosure, 415 Volts, 50 Hz, AC, 4 pole including necessary connections & modification in existing panel if required complete all as directed by Engr-in-charge.
All as per item no-40 but 100 Amps capacity
Supply and fix busbar chamber TPN-Type (AI Busbar) with IP 42 protection and Spl. 200 Amp TPN BBC (AI) with 4 O/g ways. Indo Asian Cat Part No: CPPI1026 or equivalent in Legrand/Siemens.,Complete all as specified & as directed by Engineer-In-Charge.
S & F in replacement of Automatic street light control with infrared sensor based NATURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS) Three phase load of 5 KW for automation of street lights. Nature Switch operation should be based on Natural light Lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs. VMS should have adjustable over & under Voltage trip level and protection against phase loss, Neutral loss & Phase reverse incl Power contactors (3 nos of capacity 16 amps per phase each) and incoming (3 nos of capacity 20 amps each)- outgoing MCB(3 nos of capacity 20 amps each) & main load circuit wiring (Copper) of minimum 10 sqmm. The sensor , VSM, Power contactor, MCBs incl connected items should be enclosed in a Pole/wall mountable enclosure made of rust proof, electric shock proof,termite proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for manual operation (i.e. sensor & VMS By-Pass option).Model Swadeep- 02EC5kW3P-VMS or equivqlent in Schneider/Havells/Legrand
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI wire 4 mm dia through GI pipe 15 mm dia light grade by means of bolts,nuts, check nuts and washers of galvanised iron or steel,with adequate quantity of charcoal and salt, proper watering arrangements including 20 mm dia medium grade GI tubing.PCC chamber,Chamber Cover all as shown in electrical plate No 3 of SSR part I 2009 connected to earthing test point all as specified or indicated and testing on completion. The end point connection of eatrhing will be carried out with the help of GI bolt grouted and washer and nut.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI strip 25x4 mm through GI pipe 40 mm dia light grade by means of bolts,nuts, check nuts and washers of galvanised iron or steel,with adequate quantity of charcoal and salt, proper watering arrangements including 20 mm dia medium grade GI tubing.PCC chamber,Chamber Cover all as shown in electrical plate no 3of SSR part I 2009 connected to earthing test point all as specified or indicated and testing on completion. The end point connection of eatrhing will be carried out with the help of GI bolt grouted and washer and nut.
M&L for removal of green vegetation from substations, pumphouse area by spraying the weedicide chemical Glufosinate ammonium 13.5% W/W SL using spray pump for burning of the grass on 500 Sq M Area including removing the vegetation fromits roots from existing place & depositing the vegetation away from the places , complete all as specified and directed by Engineer-in-Charge
M&L for carring out the repair to panel structure,metal body ,frame by doing necessary fabrication,replacement of the hinges, welding replacement of hinges as per reqiure exisiting door size of old,replacement of the locks,carring out necessary fabrication work using MS sheet of suitable thickness all as directed including marking of building number on front face of panel in colour as directed by Engr in charge.
Material & labour for panel painting the surfaces of outdoor LT panel(of any size) including scraping out old paint,preparation of surfaces and painting with two coat of synthetic enameled siemens grey paint complete all as directed including marking of building number on front face of panel in colour as directed by Engr In charge.
M&L for maintainance of LT panel/feeder piller box indoor/outdoor type(of any size) by cutting corroded MS lid from panel, weilding the same with 3 mm thick./ MS sheet in any desired shape including removing the carbonised/ melted sparked thimbles cleaning the carbonised bus-bar making cable end clean, welding/ replacement of broken hinges with new one,replacement of locks with new one (as per reqiurement ) mounted on exisiting door , including taking elect shut down and cleaning the all bus bar system , incomming and out going cables,replacement of burnt thimble/caple pieces/glands by using new thimble,cleaning of MCBs/ MCCBs complete all as directed including marking of building number on front face of panel in colour as directed by Engr In charge.
Material and labour for earthing (in repair) complete with copper earth plate electrode of size 60cm x 60 cm x 3.0 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 mtr below ground level connected to copper strip 20 x 3 mm by means of galvanized iron nuts & bolts or as directed at site by Engineer -in-Charge protected by GI Pipe 40 mm dia light grade and connected to test point and further connected to equipment, machinery, electrical panel or any other as directed by Engineer-in-Charge, which to be earthed, all as shown in electrical plate No 3 of SSR Part I including provision of concrete earth pit constructed in PCC 1:3:6 type C-1 as earth pit and PCC 1:2:4 type B-1 for cover slab with necessary reinforcement with handle for lifting also including provision of funnel with wire mesh with 20 mm GI pipe medium grade for watering, charcoal and salt in alternative layers of 15 cm thick all around the electrode , including necessary excavation and earth work , testing and commissioning complete all as directed.
Supply, install, testing and commissioning of cubicle type outdoor LT feeder pillar box fabricated out of 3.15mm thick CRCA sheet of size 64x64x37 cm (hight xwidthxdepth) with separate locking arrangement, painted with epoxy powder coated over a coat of red oxide primer, factory made, cubicle type, double door hinged type, both side openable, mounting electrical accessories, holes for cable entries, detachable gland plates at bottom, earth connection terminals etc. and mounted on 40x40x5 mm angle iron frame, adequate clearance from ground level for the entry and exit of cables, provision of ventilation on sides, manufacturer details, necessary PCC work for grouting and provn of cable lugs for connection etc. complete and consisting of following:- (a) MCCB 125A 4 pole, 25 KA -01 Nos ( as main incomer), (b) LED indication lamps 3 Phase,(d) 32 to 42 Amp MCB 4 TPN - 04 Nos as out goinnig (e) Aluminum bus bar 200 Amp current capacity..
Labour only for following services are to be provided for to carry out the preventive maintenance for existing electrical LT equipment of 1100 Volt and LT over head lines and all accessories by employing requisite numbers of man power (Electricians and helpers shall be experienced in their trades).will report to JE E/M in charge of receiving sub station for to receiving instructions to carrying out repair at sharp 0900 hrs on every working day i.e. for 8 hrs with necessary tools complete all as directed. (a). Carrying out periodaical checking and maintenance of LT panel (b). Checking and tightning of all jumpers, earth connection, Lightning Arresters, fuses including putting of fuses and necessary repair and maintenance as required and as directed by Engineer-in-Charge / Rep of dept in all four pole structure under complete area of 25 ED AF. (c).Checking and tightning of all jumpers, earth connection, tightning of ACSR conductor and necessary repair and maintenance as required and as directed by Engineer-in-Charge / Rep of dept in all LT O/H Feeders and LT Two pole structure under complete 25 ED AF area. (d).Checking of Earthing, test points, earth leads, periodical testing of earth resistance, cheching and rectification of earth neutral voltage fault all as directed by Engineer-in-Charge. (e).Carrying out minor repair of LT Panel and MCCB DBs tightning of terminal studs, ftc. (f). Carrying out maintenance and repair to Indoor / Outdoor LT distribution Feeder Pillar Box checking of all terminals, internal wiring, replacement of fuses all as required and directed by Engineer-in-Charge. Note :-1. The above quoted rates are deemed to include the cost of labour for cleaning of grass / bushes around the machines, plants, machines, transformers, Two/Four pole structure and Fencing for above installation. Note 2:-. Complete material and necessary T&P ( earth megger, multi meter, all electrical tools, ladder, trasportation etc.) as required for rectification of defects/attending to fault shall be arranged by contractor and cost of the same will be deemed to be included in the unit rate quoted. Note:-3. Any casualty or injury sustained by the contractor’s workers during the working hours shall be sole liability of the contractor. No claim on this account shall be entertained by the department Note 4 : If it is Elect and Helper absent from duty amount of Rs 4048/- will be recovered per day. Note 5 ;- Contractor shall ensure that during working Elect and Helper wear safety gear and eqpt.
Boring of holes under road, pavement, hard standing by trenchless technology using technique and necessary machine 0.7 to 1 mtr depth suitable for 103 mm dia DWC pipe passing complete all as directed by Engr-in-Charge.
S&F in repairs LED Perimeter light fittings 60 watt perimeter lights are aerodynamically designe for all weather conditions with excellent thermal management, made with pressure die cast housing with toughened glass and high power LED's with secondary optics and IP66 protection. Efficacy > 110/120 LPW, available with 10KV SPD extrnal surge, top opening dirver fixed on existing/new GI pipe braket fixed on HT/LT poles and connection suitable size including taking down old UNSV one all as directed. make: Crompton /Bajaj/ Havells.
S & F PVC Insulated and weather proof three core multistrand conductor cable 1.5 sqmm, size as required length for replacing US cable for street light where ever founf US from junction bos to street light all as directed by Engr-In-Charge. Make Havells, polycab, Gloster and plaza
All as per item aove but cable 2.5 sqmm, size as required length for replacing US cable for street light where ever founf US from junction box to street light all as directed by Engr-In-Charge. Make Havells, polycab, Gloster and plaza
M&L for repairing gate motor of size 2 to 3 HP remove motor form it original position and opening motor checking bearing, taking out burn winding, rewinding motor change PLC card , contactor as per existing quantity and require connection cable etc, testing complete serviceable all as directed by Engr-in-Charge
M&L for repair maintenance of existing high mast light gear assembly, taking out drive/driven gear part, steel wire rope of existing complete servicing with greasing, oiling and refitting with it original position and alignment with serviceable gear Up and down,making Highmast completely serviceable, complete all specified and directed by Engr-in-Charge
Taking Out motor from SMQ /OMQ area high mast gear assembly of capacity 3 to 5 HP motor after disconnecting all electric connections. re-winding of the motor with approved quality insulated water proof copper wire of same gauge same number of turns and same numbers of poles complete with Varnishing of re-wounded coils with insulated and packing materials, and tapping of coils, and heating in oven at desired temperature, replacement of existing bearing reconnect all the connections of starter/switch and testing complete and place the motor in same location after repair complete serviceable all as directed by Engr-in-Charge.
M&L for maintenance & servicing of servo voltage stablilizer 5-25 KVA three phase 440 V for as per sample, section Indoor/ outdoor type after disconnecting incoming & outgoing LT connection / Earthing and opening the voltage stabilizer complete and cleaning throughly, removing, cleaning old gasket and replacement with new gasket and servicing of servo motors as recommonded by the manufacture insulating properly with genuine material, and stablizer body gasket reassembling the voltage stabilizer with and repair /maintance/replacement of volt meter, Am meter, PF meter, indicator lamp RYB, servo motor, rpelace MMCB as per exisiting capacity resistance contact and remounting on foundation, complete with connecting back all removed electrical earth connection and testing on completion of functioning of the Voltage Stabilizer for stable voltage output, completed all as specified & as directed by Engineer- In - Charge.
Material & labour for replacing under voltage coil of Air Circuit Breakers Conforms to IS/IEC 60947-2 & IEC 60947-2 Current rating from 630 A ,completed all as specified & as directed by Engineer- In - Charge.
Material & labour for replacing Auxilary switch of Air Circuit Breakers Conforms to IS/IEC 60947-2 & IEC 60947-2 Current rating from 630 A ,completed all as specified & as directed by Engineer- In - Charge.
Material & labour for replacing controller & interlocking mechanism with 2NO+2NC of Air Circuit Breakers Conforms to IS/IEC 60947-2 & IEC 60947-2 Current rating from 630 A ,completed all as specified & as directed by Engineer- In - Charge.
Material & labour for retrofitting Job of L&T make 630A FP ,50KA using replacing the existing bus-bar with bus -bar of 1.5 times capacity of the incommer & doing necessary modification in the existing panel of pump House 25ED for accomodating the Air Circuit Breaker Conforming to IS/IEC 60947-2 & IEC 60947-2 Current rating of 630 A ,FP-02 Nos testing the ACBs for smooth working & to achieve constant voltage output,complete all as specified & as directed by Engineer- In - Charge. Note : The entire Job is to be executed on site within 8 hrs without disturbing the water supply of station.Contractor/tenderer is advised to visit and him-self familiar with the aforementioned No claim whatsoever entertain on non completion of job within stipulated time.
Material & labour for marking elecptical shape on the steel tubular/PCC pole in black colour and marking the pole number using suitable tensils with synthetic enamel paint in white colour in the suitable size font so that it can be visible from 7 meter away,complete all as specified & as directed by Eng-In-Charge.
Supply and fix in replacement garden light GI pipe/tubing light grade of size 50 to 63 mm outer dia not less than 1.2 Mtr long by putting in side PCC block 1:2:4 (30x30x30Cm) with cable passing arrengement in side of PCC block for guarden light fitting nuts, bolts and washers suitable etc and applying two coats of black paint over a coat of red oxide primer complete all as specified and directed. Make-/Prakesh surya/Swastik/Jindal,complete all as specified & as directed by Eng-In-Charge.
Material and labour for supply and fixing 1200 mm sweep ,BEE 5 star rated ceiling fan with brush bless direct current (BLDC) motor class of insulation B.3 nos blades 30 cm long down rod/down rod as per height avilable at site, 2 nos canopies shackle kit safety rope copper winding, power factor not less tha.09 service value (CMM/W) minimum 6.0 Air delivery minimum 210 CMM 350 RPM (tolrance as per IS 374-2019) THD less than 10% remote or electronic regulator unit for speed control and all remaning accessoiries inculuding safety pin nut boltts washesrs temperature rise=75 degree C (max) insulation resistance more than 2 mega ohm and 26 to 30 watt, suitable for 230 volt V 50 Hz single phase AC supply etc, complete with fixing arrenement anchor type faster hook including connection with 1.5 sqmm multisand copper conductor flexible wire from ceiling rose to fan down through PVC flexible conduit complete including taking down old and deposited to MES store yard all as specified and directed
Taking down solar street light/Gate light LED acrylic letters Name of (AIR FORCE STATION DEOLALI ) from pole and repair/ servicing of check mono crystaline panel/ lithium ferro phospate (LifeP0 4) , replace battery, MPPT charge controller and PIR sensor with colour complete refixing at existing locations or as directed by Eng. in charge, connecting with source and testing for proper functioning of the solar fittings complete as directed. Note :Rate are included require material for solar light and LED acrylic letters Name of (AIR FORCE STATION DEOLALI serviceable
S&F in replacement street light brackets with 32/36/40 mm dia GI tubing light grade, 1.5 metre length, bend to shape using sand at 45 degrees including fixing with suitable MS clamps made out of MS flat 40x3 mm, nuts, blots, washers etc. and fitted on 11 meter HT/LT poles/walls all as directed.
Taking down of carefully existing old unserviceable over head LT/HT ACSR conductor,cross arms ,clamps , insulator of from existing RCC/steel tubular pole of height 9 to 11 Mtr pole SMQ and OMQ area complete with safety precaution contractor and super wiser ensure road traffic movement, during taking down over head LT conductor Complete with closed conductor 1.5 to 2 Mtr circumference and tight with binding wire deposits to E&M store. (Note 1: Material and necessary T&P for taking down of LT over head line, all electrical tools, ladder, transportation shall be arranged by contractor and cost of the same will be deemed to be included in the unit rate quoted. Note 2: Any casualty or injury sustained by the contractor’s workers during the working hours shall be sole responsibility of the contractor. No claim on this account shall be entertained by the department. Note 3. 5 to 6 conductor taken as one length for measurement.)
Supply, install, testing and commissioning of IP 65 cubicle type 300 Amp mini-pillar box with TPN copper bus bar of size (30x10mm) fabricated out of 3.15mm thick CRCA sheet of size not less than 500mmx500mmx250mm with MS angle iron frame of size not less than 50x50x6 mm fitted on wall ground without damage existing wall repair surface as match with existing surface with PCC complete and heat shrinkable cable joint kit , straight through , out door type for 1100 volts LT XLPE/PVC insulated cable of aluminium conductor 25 sqmm to 95 sqmm 3/5 core cable including necessary jointing work if require site all as specified and directed by Engr-in-Charge.
MAHIMA CONSTRUCTION (BID ID -3503089)
Shree Sai Samarth Enterprises (BID ID -3503177)
M/s.NIKI ENTERPRISES (BID ID -3503448)
United Enterprises (BID ID -3503358)
DIAMOND ENTERPRISES (BID ID -3503182)
LOKMANYA ENTERPRISES (BID ID -3503623)
SHRI SULAI ELECTRICALS (BID ID -3503332)
stage.html
html • 0.06 MB
technical_831085.pdf
techsummary_831085.pdf
finance_831085.pdf
BOQ Comparative Chart
xlsx
finsummary_831085.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.30 MB
GENPAGE8360.pdf
Tender Documents • 0.48 MB
PSEM8360.pdf
Tender Documents • 0.79 MB
CREDIT8360.pdf
Tender Documents • 0.35 MB
BOQ_831085.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .