Tender Value
Refer Docs
Closing Date
13 Jul 2026, 6:00 pm5d left
Ex.Engr.Jigaon Project Dam and Rehab.Dn.,Shegaon
Executive Engineer,Jigaon Project Dam and Rehabilitation Division, Nr By Shri Sant Gajanan Maharaj Vatika, Khamgaon Road, Shgaon Dist. Buldana 444203
Instalation of Dam Instruments at Jigaon Project Tal Nandura Dist.Buldhana
2026_CEWRA_1313816_1
Budgetary_Offer_No_01/2026-27
Open Tender
Supply, Erection and Commissioning
Jigaon Project Tal Nandura Dist.Buldhana
Please refer Budgetary Offer notice and BOQ
2 documents required · 2 mandatory
₹0
Exempted
6 Jul 2026
6 Jul 2026
15 Jul 2026
6 Jul 2026
13 Jul 2026
6 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing and installing Long Guage Extensometer Multiplebore hole Extenssometer For Concrete Spillway.
Specification
Measurement Range: 0–300 mm
Accuracy: ±0.1% F.S.
Resolution: 0.01 mm
Protection: IP68
Cable Requirement: Shielded, UV resistant, armoured, 4-core
Installation: Installed in drilled borehole with anchors at specified depths
Calibration: Factory calibration with traceable certificate
Acceptance Tests: Calibration certificate, insulation test, field baseline reading | - | No. | - | - |
| 2 | Providing and installing Tiltmeter For Concrete Spillway.
Specification
Measurement Range: 0–300 mm
Accuracy: ±0.1% F.S.
Resolution: 0.01 mm
Protection: IP68
Cable Requirement: Shielded, UV resistant, armoured, 4-core
Installation: Installed in drilled borehole with anchors at specified depths
Calibration: Factory calibration with traceable certificate
Acceptance Tests: Calibration certificate, insulation test, field baseline reading | - | No. | - | - |
| 3 | Providing and installing Temperature Stress For Concrete Spillway.
Specification
Measurement Range: 0–300 mm
Accuracy: ±0.1% F.S.
Resolution: 0.01 mm
Protection: IP68
Cable Requirement: Shielded, UV resistant, armoured, 4-core
Installation: Installed in drilled borehole with anchors at specified depths
Calibration: Factory calibration with traceable certificate
Acceptance Tests: Calibration certificate, insulation test, field baseline reading | - | No. | - | - |
| 4 | Providing and installing Laser Plumb bob For Concrete Spillway.
Specification
Measurement Range: 0–300 mm
Accuracy: ±0.1% F.S.
Resolution: 0.01 mm
Protection: IP68
Cable Requirement: Shielded, UV resistant, armoured, 4-core
Installation: Installed in drilled borehole with anchors at specified depths
Calibration: Factory calibration with traceable certificate
Acceptance Tests: Calibration certificate, insulation test, field baseline reading | - | No. | - | - |
| 5 | Providing and installing Pore pressure Transducers For Earthen Dam.
Specification
Measurement Range: 0–300 mm
Accuracy: ±0.1% F.S.
Resolution: 0.01 mm
Protection: IP68
Cable Requirement: Shielded, UV resistant, armoured, 4-core
Installation: Installed in drilled borehole with anchors at specified depths
Calibration: Factory calibration with traceable certificate
Acceptance Tests: Calibration certificate, insulation test, field baseline reading | - | No. | - | - |
| 6 | Providing and installing Casagrande/ Stand Pipe Piezometer For Earthen Dam.
Specification
Measurement Range: 0–300 mm
Accuracy: ±0.1% F.S.
Resolution: 0.01 mm
Protection: IP68
Cable Requirement: Shielded, UV resistant, armoured, 4-core
Installation: Installed in drilled borehole with anchors at specified depths
Calibration: Factory calibration with traceable certificate
Acceptance Tests: Calibration certificate, insulation test, field baseline reading | - | No. | - | - |
| 7 | Providing and installing Horrizontal/ Vertical/ Cross arm Surface settlement plug For Earthen Dam.
Specification
Measurement Range: 0–300 mm
Accuracy: ±0.1% F.S.
Resolution: 0.01 mm
Protection: IP68
Cable Requirement: Shielded, UV resistant, armoured, 4-core
Installation: Installed in drilled borehole with anchors at specified depths
Calibration: Factory calibration with traceable certificate
Acceptance Tests: Calibration certificate, insulation test, field baseline reading | - | No. | - | - |
| 8 | Providing and installing Earth pressure Cells For Earthen Dam.
Specification
Measurement Range: 0–300 mm
Accuracy: ±0.1% F.S.
Resolution: 0.01 mm
Protection: IP68
Cable Requirement: Shielded, UV resistant, armoured, 4-core
Installation: Installed in drilled borehole with anchors at specified depths
Calibration: Factory calibration with traceable certificate
Acceptance Tests: Calibration certificate, insulation test, field baseline reading | - | No. | - | - |
| 9 | Providing and installing 2 Pair ,4 core Armoured Jelly filled 7/0.34 mm annealed copper, petroleum jelly filled, 0.5 mm Ø galvanized steel wire armoured cable with Splicing Kit, water proof label and proper harnessing and protection cover with VW read out unit for 622 sensors as per direction of Engineer Incharge etc complete.
Specification
Measurement Range: 0–300 mm
Accuracy: ±0.1% F.S.
Resolution: 0.01 mm
Protection: IP68
Cable Requirement: Shielded, UV resistant, armoured, 4-core
Installation: Installed in drilled borehole with anchors at specified depths
Calibration: Factory calibration with traceable certificate
Acceptance Tests: Calibration certificate, insulation test, field baseline reading | - | Mtr | - | - |
| 10 | Providing and installing 10 P, 20 core 7/0.25 mm ATC, twisted pairs screened with water blocking aluminum foil, 0.3 mm galvanized iron wire braid armoured Jelly filled cable with Splicing Kit, water proof label and proper harnessing and protection cover with VW read out unit for connecting sensors to data logger units as per direction of Engineer Incharge etc complete.
Specification
Measurement Range: 0–300 mm
Accuracy: ±0.1% F.S.
Resolution: 0.01 mm
Protection: IP68
Cable Requirement: Shielded, UV resistant, armoured, 4-core
Installation: Installed in drilled borehole with anchors at specified depths
Calibration: Factory calibration with traceable certificate
Acceptance Tests: Calibration certificate, insulation test, field baseline reading | - | Mtr | - | - |