| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC PHAYANG GOMPA COMPLEX AGLING ROAD SKALZANGLING LEH LADAKH J K 194101 | LEH | LEH | LADAKH | 194101 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹40.7 L+₹6.5 L (19.1%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L2 | Rejected-Finance Other than lowest Bidder | |
| 3 | L3₹44.3 L+₹10.1 L (29.6%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L3 | Rejected-Finance Other than lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
21 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col S S Babu
Headquarters 138 Works Engineers Pin-914138 C/o 56 APO
Repair and Maint of Central Heating Plant and Hot water plant installed at OTM accn of 153 GH, CHS and Charlie Mess and Oil fired incinerator under AGE EM II of GE 865 EWS at Leh
2021_MES_461271_1
138WE/L-44/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 865 EWS
₹96,000
Yes
18 Sept 2021
20 Jul 2021
23 Aug 2021
20 Jul 2021
21 Aug 2021
3 Aug 2021
60 days
Amount
Dismantling of burner assembly of CHS and remvoing of side cover and repairing the same by removing the old burnt fire refractory cement plastering, replastering the same as per existing with fire refractory cement for boiler capacity 3-4 lakh kilo/cal/hr and complete servicing the boiler by removing the complete carbon/oil deposits with suitable coil shine chemical including repir to coil assembly by welding if there is any leakage found or any other repair required at site and reassembling/ testing the same, (4 Months after again service) complete all as specified and directed.
S&F in sequence controller suitable for 3-4 lakh kilo/hr with burner rod assembly, complete all as specified and directed.
S&F in replacement of ignition rod suitable for 3-4 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed.
S&F in replacement of ignition Transformer electronic type suitable for 3-4 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed.
S&F temp controller digital type DTC 503 with sensor suitable for 3-4 lakh kilo/Cal/hr LAL 2.25 burner rod assembly, complete all as specified and directed.
S&F in replacement of photo cell as per existing suitable for 3-4 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed.
S&F in replacement of burner nozzle suitable for 3-4 lakh K/Cal/Hr, complete all as specified and directed.
S&F in replacement of Electrode suitable for burner of capacity 3-4 lakh K/Cal/Hr, complete all as specified and directed.
Dismantling of burner assembly of CHS and remvoing of side cover and repairing the same by removing the old burnt fire refractory cement plastering, replastering the same as per existing with fire refractory cement for boiler capacity 1-2 lakh kilo/cal/hr and complete servicing the boiler by removing the complete carbon/oil deposits with suitable coil shine chemical including repir to coil assembly by welding if there is any leakage found or any other repair required at site and reassembling/ testing the same, (4 Months after again service) complete all as specified and directed.
S&F in sequence controller suitable for 1-2 lakh kilo/hr with burner rod assembly, complete all as specified and directed.
S&F in replacement of ignition rod suitable for 1-2 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed.
S&F in replacement of ignition Transformer electronic type suitable for 1-2 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed.
S&F temp controller digital type DTC 503 with sensor suitable for 1/2 lakh kilo/Cal/hr LAL 2.25 burner rod assembly, complete all as specified and directed.
S&F in replacement of photo cell as per existing suitable for 1-2 lakh kilo/Cal/hr burner rod assembly, complete all as specified and directed.
S&F in replacement of burner nozzle suitable for 1-2 lakh K/Cal/Hr, complete all as specified and directed.
S&F in replacement of Electrode suitable for burner of capacity 1-2 lakh K/Cal/Hr, complete all as specified and directed.
S&F in replacement of pressure gauage 0 to 20 Kg/cm sq as per existing, complete all as directed by Engineer-in-Charge.
S&F in replacement of Bridge rectifire complete all as specified and directed by Engr-in-Charge.
S & F in replacement of hooter round type, complete all as specified and directed.
S&F in replacement of thermostate assembly tail type as per existing suitable for 0-30 degree centrigrade temprature, complete all as specified and directed.
M&L for repair of exhaust pipe by welding, complete all as specified and directed.
S&F in replacement of auto air pressure valve 3/8" as per existing, complete all as specified and directed.
S&F in replacement of High pressure fuel pipe 1.5 mtr as per existing, complete all as specified and directed.
Material and labour for taking down and Re fixing the same after rewinding of electric motor 3 phase 415 volts of capacity 7.5 HP with superior quality super enameled copper winding wire of appropriate size and gauge as existing including varnishing , cotton tape, PVC sleeves etc, complete all as specified and directed.
Material and labour for taking down and Re fixing the same after rewinding of electric motor 3 phase 415 volts of capacity 5.0 HP with superior quality super enameled copper winding wire of appropriate size and gauge as existing including varnishing , cotton tape, PVC sleeves etc, complete all as specified and directed.
Material and labour for taking down and Re fixing the same after rewinding of electric motor 3 phase 415 volts of capacity 3.0 HP with superior quality super enameled copper winding wire of appropriate size and gauge as existing including varnishing , cotton tape, PVC sleeves etc, complete all as specified and directed.
M&L for servicing to the glycol pump and motor of capacity 3.0 HP, 2870 RPM including replacement of bearings, oil seals or any other spares / work required for smooth functioning of pump, complete all as specified and directed.
M&L for servicing to the glycol pump and motor of capacity 5.0 HP, 2870 RPM including replacement of bearings, oil seals or any other spares / work required for smooth functioning of pump, complete all as specified and directed.
Material and labour for taking down and Re fixing the same after rewinding of electric motor single phase 240 volts of capacity 1-2 HP with superior quality super enameled copper winding wire of appropriate size and gauge as existing including varnishing , cotton tape, PVC sleeves etc, complete all as specified and directed.
M & L for disconnecting the all connection in existing panel board complete and re-fixing the same after removing the burnt lugs/thimbles complete including replacing the U/S MCCBS, Contactors, relay, bus bar indicator lamps etc., all as specified and as direcrted. Note- MCCBS, Contactors, relay, indicator lamps, S/Switchs are to be measured and paid seperately.
S&F in replacement of contactor type 3 TF 33, 415 volts complete all as specified and directed. Make : Siemens, L&T, Havells
S&F in replacement of contactor type ML 1.5, 220 volts, complete all as speified and directed. Make : Siemens, L&T, Havells
S&F in replacement of over load relay 8 to 12.5 Amps for contactor matching ser No 48 series 3 TF 33 complete all as specified and directed. Make- Siemens, L & T , Havells
S&F in replacement of over load relay 1.25 to 2 Amps for contactor matching ser No 49 series 3 TF 33, complete all as specified and directed. Make : Siemens/L&T/Havells
S&F MCCB with current rating 160 Amps 415V 4 Pole 36 KA with thermally adjustable complete all as specified and as directed by Engr-in-charge.
S&F MCCB with current rating 200 Amps 415V 4 Pole 36 KA with thermally adjustable complete all as specified and as directed by Engr-in-charge.
S&F MCCB with current rating 100 Amps 415V 4 Pole 16 KA complete all as specified and as directed by Engr-in-charge.
S&F in replacement of digital type volt meter 0-500 volts, complete all as specified and directed.
S&F in replacement of digital type Amp meter complete with suitable CTs 0-300 Amps, complete all as specified and directed.
S&F in replacement of indicating lamps RYB as per existing complete all as specified and directed.
S&F in replacement of rotary type ON/OFF switches, 22mm dia as per existing, complete all as specified and directed.
S&F in replacement of push button switch in RED or GREEN colours, 22mm dia as per existing, complete all as specified and directed.
S&F in replacement of PVC flexible copper multistrand wire 3 core of 6 sqmm as per existing, complete all as specified and directed.
S&F in replacement of PVC flexible copper multistrand wire 3 core of 4 sqmm as per existing, complete all as specified and directed.
M&L for insulation of MS pipe with PUF slab 40 mm thick with and including applying bituminous compound and GI cladding with 26 gauge GI sheet complete of size of 80mm dia of pipe, complete all as specified and directed by Engr-in-charge
M&L for insulation of MS pipe with PUF slab 30 mm thick with and including applying bituminous compound and GI cladding with 26 gauge GI sheet complete of size of 50mm dia of pipe, complete all as specified and directed by Engr-in-charge
M&L for welding the leakage portion of MS Pipe line including all T&P and materials required for welding the pipe line of size 25mm to 200mm including testing on full pressure complete all as specified and directed by Engr-in-charge
S&F in replacement of gun metal butter fly control valves of 65mm bore as per existing, complete all as specified and directed complete all as specified and directed by Engr-in-charge
S&F in replacement of gun metal butter fly control valves of 80mm bore as per existing, complete all as specified and directed complete all as specified and directed by Engr-in-charge
S&F in replacement of gun metal butter fly control valves of 50mm bore as per existing, complete all as specified and directed complete all as specified and directed by Engr-in-charge
S&F in replacement of gun metal butter fly control valves of 40mm bore as per existing, complete all as specified and directed complete all as specified and directed by Engr-in-charge
M&L for Cleaning of MS diesel storage tanks (day to day tank) of capacity 1000 ltrs by removing of sludge from tanks and scrapping the side walls by means of wire brush or emery paper and wash the same with castic soda and clear water and painting the internal wall with two coats of black rubber emulsion paint and painting the complete tank from out side with two coats of synthetic enamel paint, complete all as specified and directed.
M&L for Cleaning of MS diesel storage tanks of capacity 10000 ltrs by removing of sludge from tanks and scrapping the side walls by means of wire brush or emery paper and wash the same with castic soda and clear water and painting the internal wall with two coats of black rubber emulsion paint and painting the complete tank from out side with two coats of synthetic enamel paint, complete all as specified and directed.
M&L for Cleaning of MS over head circulation tank of capacity 1000 ltrs of all type of T&P and chemical reqd the same, including welding work to leakage surface including opening and refixing the existing insulating material to the external surface including painting the complete tank from out side with two coats of synthetic enamel paint, complete all as specified and directed.
Supply and replacement of MS Pipes (ERW) heavy duty including fittings grade with all fittings complete of size 100 MM dia, complete all as specified and directed by Engr-in-Charge. (Note - The rate include cutting to any levels/shapes like elbows, teesbends etc welding joints wherever necessary as per the site requirement)
Supply and replacement of MS Pipes (ERW) heavy duty including fittings grade with all fittings complete of size 80 MM dia, complete all as specified and directed by Engr-in-Charge. (Note - The rate include cutting to any levels/shapes like elbows, teesbends etc welding joints wherever necessary as per the site requirement)
Supply and replacement of MS Pipes (ERW) heavy duty including fittings grade with all fittings complete of size 50 MM dia, complete all as specified and directed by Engr-in-Charge. (Note - The rate include cutting to any levels/shapes like elbows, teesbends etc welding joints wherever necessary as per the site requirement)
Supply and replacement of MS Pipes (ERW) heavy duty including fittings grade with all fittings complete of size 40 MM dia, complete all as specified and directed by Engr-in-Charge. (Note - The rate include cutting to any levels/shapes like elbows, teesbends etc welding joints wherever necessary as per the site requirement)
Supply and replacement of MS Pipes (ERW) heavy duty including fittings grade with all fittings complete of size 25 MM dia, complete all as specified and directed by Engr-in-Charge. (Note - The rate include cutting to any levels/shapes like elbows, teesbends etc welding joints wherever necessary as per the site requirement)
Supply and replacement of MS Pipes (ERW) heavy duty including fittings grade with all fittings complete of size 20 MM dia, complete all as specified and directed by Engr-in-Charge. (Note - The rate include cutting to any levels/shapes like elbows, teesbends etc welding joints wherever necessary as per the site requirement)
Supply and replacement of FCU connection flexible pipe 20/16 mm as per existing, complete all as specified and directed.
S&F in replacement of FCU connection copper pipe 20/16 mm with check nut at both side as per reqd length, complete all as specified and directed by Engr-in-Charge
Supply and fix switch socket combination of 5Amp flush type comple all as specified and directed by Engr-in-charge
S&F in replacement of plug top 3 pin of capacity 5Amp complete all as specified and directed by Engr-in-Charge.
M&L for Electrical control wiring for FCU of any size including electronic display complete as per sample all as specified and directed by Engr-in-Charge
M&L only for attending of break down/day to day complaint or call on attending any break down or maint work in CHS located in GH OTM, FSH and 'C' Mess checking the serviceability of fan coil unit of any capacity for having continuous serviceability of FCU for any number of time as desired by Engr-in-charge including replacement of minor spare part like Gasket, Teflon tape, flare nut, tightening of any loose glycol line connections, shifting FCU from one place to another place if required, heating up the freezed glycol line any where about the premices to have continuous flow of glycol fluid, repairing the insulation of pipe line of any size by providing shallow tape/ GI wire as deemed fit, for fastening the insulation with pipe line, stopping any kind of leakage from any size of pipe line, tightening the loose electrical connections as related with FCU/Heating system, cleaning the air filter including radiator of FCU to the entire satisfaction of Engr-in-charge complete as as directed at site.
Dismantling the existing radiator unit of capacity from 3000 to 6500 K Cal per hour, taking it to nearest workshop cleaning the complete unit with coilshine chemical, detecting the leakage protion by applying nitrogen gas pressure, brazing the leakage portion by applying nitrogen gas pressure, brazing the leakage portion, refixing the same unit from dismantled location including testing on load complete all as directed at site by Engr-in-charge.
Supply and fixing radiator unit of FCU including connection with the unit and making it leak proof of consisting of copper coils covered with aluminium finishing as per existing size of capacity 3000K Cal/Hour including dismantling the existing unserviceable.
Supply and fixing radiator unit of FCU including connection with the unit and making it leak proof of consisting of copper coils covered with aluminium finishing as per existing size of capacity 4500K Cal/Hour including dismantling the existing unserviceable.
Supply and fixing radiator unit of FCU including connection with the unit and making it leak proof of consisting of copper coils covered with aluminium finishing as per existing size of capacity 6000K Cal/Hour including dismantling the existing unserviceable.
Supply and fix in replacement of needle valve 3/8 inch BSP as per existing complete all as specified and directed by Engr-in-charge
S&F in replacement of ring 'O' Clip of flexible pipe of existing size complete all as specified and directed by Engr in charge
Supply and fix inlet/outlet forged brass ball valve 20mm with Y stainer for FCU, hot water for 25 to 90 degree temperature as per existing, incluing supply and fixing of GI nipple of size 3/4 inch including welding work cutting the existing rusty unserviceable MS/GI nipple complete including taking out existing unserviceable valve complete all as specified and directed.
Supply and fix inlet/outlet forged brass ball valve 15mm with Y stainer for FCU, hot water for 25 to 90 degree temperature as per existing, incluing supply and fixing of GI nipple of size 3/4 inch including welding work cutting the existing rusty unserviceable MS/GI nipple complete including taking out existing unserviceable valve complete all as specified and directed.
S&F for closed cell elastometric insulation 30 to 40 Kg/Cub mtr density 25 mm thick (nitrite insulation) complete all as specified, Make- Eurobatex/ Superion/ Aeorflex.
S&F in replacement of Oil Pressure pump 7276-3D67A complete all as specified and directed by Engr-in-charge
S&F in Repair / replacement of fan coil unit parts, duel shaft electric motor of capacity 30 watt 930 RPM, 3 speed as per existing, complete all as specified and directed.
Supply and replacement of PP-R Pipe with fitting of 40 MM size, complete all as specified and directed.
Supply and replacement of PP-R Pipe with fitting of 32 MM size, complete all as specified and directed.
Supply and replacement of PP-R Pipe with fitting of 25 MM size, complete all as specified and directed.
Supply and replacement of PP-R Pipe with fitting of 20 MM size, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for foundation, laying of pipes, cables etc. Or for manholes pier holes poles not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out in hard/dence soil complete all as specified and directed by Engr-in-charge
Returning filling in soil including spreading levelling watering and well ramming in layers not exc. 25cm thick complete all as specified and directed by Engr in Charge.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 above the starting point including spreading and leveling complete all as specified and directed by Engr-in-charge.
S&F in replacement Temp controller regular type complete all as specified and directed by Engr-in-charge
Supply and fixing in replacement of Lagging all around with 150 mm thick sections bonded mineral wool of density 144 kg /cum conforming to IS 9842 for heating circulation pipe lines of 150mm over chicken wiremess complete and as directed. Note : Retrieved glass wool to be disposed off by the contractor.
Supply and fixing in replacement of Lagging all around with 100 mm thick sections bonded mineral wool of density 144 kg /cum conforming to IS 9842 for heating circulation pipe lines of 100mm over chicken wiremess complete and as directed. Note : Retrieved glass wool to be disposed off by the contractor.
Supply and fixing in replacement of Lagging all around with 80 mm thick sections bonded mineral wool of density 144 kg /cum conforming to IS 9842 for heating circulation pipe lines of 80mm over chicken wiremess complete and as directed. Note : Retrieved glass wool to be disposed off by the contractor.
Supply and fixing in replacement of Lagging all around with 65 mm thick sections bonded mineral wool of density 144 kg /cum conforming to IS 9842 for heating circulation pipe lines of 65mm over chicken wiremess complete and as directed. Note : Retrieved glass wool to be disposed off by the contractor.
Supply and fixing in replacement of Lagging all around with 50/40 mm thick sections bonded mineral wool of density 144 kg /cum conforming to IS 9842 for heating circulation pipe lines of 50/40mm over chicken wiremess complete and as directed. Note : Retrieved glass wool to be disposed off by the contractor.
M&L for Galvanised iron pipe medium grade of size 50mm dia complete with all fitting and fixed complete to wall and ceillings or laid in floors complete all as specified and directed by Engr-in-Chrage
M&L for Galvanised iron pipe medium grade of size 40mm dia complete with all fitting and fixed complete to wall and ceillings or laid in floors complete all as specified and directed by Engr-in-Chrage
M&L for Galvanised iron pipe medium grade of size 25mm dia complete with all fitting and fixed complete to wall and ceillings or laid in floors complete all as specified and directed by Engr-in-Chrage
M&L for Galvanised iron pipe medium grade of size 20mm dia complete with all fitting and fixed complete to wall and ceillings or laid in floors complete all as specified and directed by Engr-in-Chrage
M&L for Gun-metal, gate valves with iron wheel head, screwed both ends for iron pipe and fixing or size 25mm complete all as specified and directed by Engr-in-charge.
M&L for Gun-metal, gate valves with iron wheel head, screwed both ends for iron pipe and fixing or size 20mm complete all as specified and directed by Engr-in-charge.
M&L for Gun-metal, gate valves with iron wheel head, screwed both ends for iron pipe and fixing or size 40mm complete all as specified and directed by Engr-in-charge.
M&L for Gun-metal, gate valves with iron wheel head, screwed both ends for iron pipe and fixing or size 50mm complete all as specified and directed by Engr-in-charge.
M&L for dismantling of burner rod assy and removing of top cover of boiler capacity 20 lakh kilo/cal/hr model TPA-20/L/P/17 and complete servicing the boiler by using coil shine chemical and removing the complete carbon/oil deposits including repair to coil assy if there is any leakage found and reassebling/testing the same complete all as specified and directed by Engr-in-charge.
M&L for complete servicing to the thermic fluid pump and electric motor of capacity 60HP 2960 RPM, by following services :- (a) Replacement of berarings, oil carbon glands seal or any other spares required for smooth functioning of pump, complete all as specified as directed. (b) Repair/replacement impeller suitable for 60 HP centrigugal pump (c) Pump shaft including steel gland bush suitable for centrifugal pump of capacity 60 HP
M&L for servicing to the modulation assebly including replacement of fuel control valve or any other spares required for smooth functioning of modulation assy all as specified and directed by Engr-in-charge.
M&L for replacement of star coupling with rubber love joint coupling F225 suitable for 60 HP TF Pump
M&L for servicing of Air Handling Unit capacity 15000 CFM including repair to coil assy by welding if there is any leakage found and testing the same, replacement bearings of motor capacity 7.5 HP/10HP, reassembling/testing the same including painting of AHU with two coats of aluminium paint over a coat of red oxide primer and cleaning of AHU room complete all as specified and directed by Engr-in-charge.
M&L for servicing of Air Handling Unit capacity 10000 CFM including repair to coil assy by welding if there is any leakage found and testing the same, replacement bearings of motor capacity 5.5 HP/10HP, reassembling/testing the same including painting of AHU with two coats of aluminium paint over a coat of red oxide primer and cleaning of AHU room complete all as specified and directed by Engr-in-charge.
S&F in replacement V Belt B-77/B-100 suitable for AHU as per sample all as specified and as directed
Supply, fixing and testing fuel injection nozzle suitable for working on 20 Lac K Cal/Hr oil fired boiler capacity burner complete all as specified and directed
M&L for control wiring of complete AHU of capacity 15000/10000 CFM connecting blower motor of capacity 7.5/10 HP with auto control panel with PVC copper conductor of not less than 4/6 Sqmm including binding of complete wiring with tie, concealed channel as required at site complete all as directed and testing to the entire satisfaction of Engr-in-charge
M&L for cleaning of Thermic fluid pipe line ducts complete incuding removing of wastage sand stone, etc complete all as specified and directed by Engr-in-Charge.
M&L for removing of old unsv refractory compound from oil fired incinerator and oil fired boiler at 153 GH and applying the same evenly iside the surface of oil fired incinerator and oil fired boiler with refactory compound complete all ass specified and directed by Engr-in-charge
M&L for replacement of digtal temperature controller suitable for oil fired incinerator panel board as per sample with sensor complete all as specified and as directed by Engr-in-charge. Make : AE/L&T/Schneider
M&L for replacement of photo cell as per existing suitable for boiler of oil fired incinerator assy model TPA-20/L/P/17 complete all as specified and as directed by Engr-in-charge
M&L for welding work as reqd for separate chamber including removing, cutting the crodded portion and reassembling, testing the unit after welding complete all as specified and directed by Engr-in-charge
M&L for welding work as per site reqmt to leakage in steel pipe complete all as specified and directed by Engr-in-charge
M&L for removing old burnt carbon from chimeny of oil fired incenator and cleaning the chimney complete all as specified and directed by Engr-in-charge
M&L only for attending of break down/day to day complaint or call on attending any break down or maint work in CHS of cap 20lkcal/hr located in 153 GH checking the serviceablility of AHU's/Boilers/Fluid lines/AHU's motors of any capacity for having continuous serviceablility of CHS plant in 153 GH for any number of time as desired by Engr-in-charge including servicing of GI Duct use for following of Hot air and replacement of minor spare parts required at site and maint the fluid pipe line any where about the premices to have continuous flow of Thermic fluid, repairing the insulation of pipe line of any size, stopping any kind of leakage from any size of pipe line, tightening the loose electrical connections as related with AHU's panel/Main electrical panel/AHU remote control panel including all other related complaints to the entire satisfaction of Engr-in-charge complete all as specified at site.
EESSI
national engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .