Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹31.2 L+₹3.4 L (12.2%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹38.1 L+₹10.2 L (36.8%)Rejected-Finance | L3 | Rejected-Finance Not Lowest |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
7 Dec 2022, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIR/ MAINTENANCE OF HT/LT SWITCH GEAR, PANELS, OH LINES/UG CABLES, TRANSFORMERS AND OTHER CONNECTED WORKS AT AGE B/R-II SECUNDERABAD
2022_MES_562554_1
GE I KBAGH TOKEN 47 OF 2022 2023
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹88,000
Yes
21 Dec 2022
11 Nov 2022
9 Dec 2022
11 Nov 2022
7 Dec 2022
24 Nov 2022
11 Nov 2022 - 17 Nov 2022
Amount
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick using soil complete all as directed.
Removing excavated material to a distance exc 250m but n exc. 500m and depositing where directed at a level n exc. 1.5m above the starting point (Soils) complete all as directed.
Supply and spreading natural dry, clean river sand in trenches for cushioning of cable complete all as directed.
M&L for brick protection with common burnt bricks sub class ‘B’ of size 230x115x75mm for cable protection complete all as directed.
S&F reinforced precast concrete cable cover class HV type 1 flat of size 300mmx 180mm x 40mm complete all as directed.
Supply, laying, testing and commissioning of Cable with Stranded Compacted Circular Aluminium Conductor, 11000Volts, UE, Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated, Insulation Screened with extruded semi-conducting compound in combination with copper tape cores laid up, inner sheath of Thermoplastic tape, galvanised flat steel strip armoured and overall Extruded PVC Type ST-2 Outer Sheathed cable conforming to IS:7098/II/85 of size 120 sqmm, 3 core with appropriate lugs including taking down unserviceable cable complete all as directed.
All as per item No 7.00 here-in-before but 95 sqmm 3 core complete all as directed.
M&L in repairs for cable jointing kit for 11000Volts (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as directed.
All as per srl item No 9 here-in-before but 50 sqmm to 95 sqmm all as directed.
M&L in repairs for cable jointing kit for 11000Volts (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as directed.
All as per item No 11 here-in-before but 50 sqmm to 95 sqmm all as directed. Make for item srl No 09 to 12 : Raychem/M-Seal/3M
M&L for GI tubing of 100 mm bore 'Light Grade' for protection of HT cable with all fixing accessories laid in trenches/walls including taking down unserviceable GI tube complete all as directed. Make:Jindal/Tata/Zenith
M&L for cleaning 2/3 Pole structure of any height including Cross arm and Angles of any description cleaning thoroughly with cleaning agent including scrapping the old corroded paint / rust carefully and applying two coats of aluminium paint (From coping to GOD) and two coats of Red postal colour Paint from GOD to above of pole and sturcture, over one coat of red oxide metal primer paint and marking of Strip (01 to 03) by Fluroscent Paint as per KV Grading up to a height of 1.5m above, the PCC coping shall painted with 02 coats of black synthetic enamel paint including writing of pole numbers complete all as directed. (CE (R&D) office complex, CE (R&D) Residential area, Pratap Colony, DMDE, SERA, VVRA, Diber) Note :- Zebra Strip size & Colour of painting shall as required at site and as directed at the time of execution. Make:- ASIAN/SHALIMAR/BERGER
M&L for cutting and removing grass, plants, bushes etc., and the cut grass, plants, bushes to be taken out or destroyed by the contractor to a distance exceeding 2 KM from the site of work complete all as directed .
M&L for spreading and leveling of 40mm graded stone aggregate over stone dust (0-3mm) in transformer yard complete all as directed by Engr-in-charge. Note : After ramming stone dust layer will be of minimum 25mm thickness
M&L for Cutting and removing tree branches of any height and of any size, hanging on HT/LT lines, street lights, and the cut tree branches / trimming and shall be removed to a distance exceeding 2 km and not exceeding4 Km from the site of work complete all as directed
Material and Labour for cutting existing BT road/PCC of size 45cm x 60cm for taking out/laying of underground cable/pipe and including necessary earth work and refilling the same in layers well ramming including watering as required and matching with the existing surface with 200mm thick PCC 1:2:4 type B1 and curing the same with wet gunny bags and removing debris to a distance not less than 50m complete all as specified and as directed .
S&F Laying LT UG cable heavy duty armoured with aluminum conductor multistranded PVC insulated and sheathed with suitable lugs including taking out old unserviceable cable complete all as directed for following sizes: -
2 core 10 Sqmm
4core 16 Sqmm
3.5 core 25 Sqmm.
3.5 core 50 Sqmm.
3.5 core 95 Sqmm.
3.5 core 185 Sqmm.
3.5 core 240Sqmm. Note: - .Excavation & earthwork, sand cushioning and brick protection shall be measured and paid seperately under relevant items.
S&F in replacement Alluminium lugs of following sizes:- Make : Dowell/Jainson
16 to 35 Sqmm
S&F MCCB four pole 250 Amps, 415 volts 36 KA, including taking out old unserviceable MCCB complete all as directed.
S&F MCCB four pole 160 Amps, 415 volts 36 KA, including taking out old unserviceable MCCB complete all as directed.
S&F MCCB four pole 100 Amps, 415 volts 16 KA, including taking out old unserviceable MCCB complete all as directed.
S&F MCCB four pole 63 Amps, 415 volts 16 KA, including taking out old unserviceable one complete all as direced.
S&F Change over switch 200 amps, four pole,415 amps with all accessories & suitable lugs including taking out old unserviceable change over switch complete all as directed.
S&F Change over switch 320 amps, four pole,415 amps with all accessories & suitable lugs including taking out old unserviceable change over switch complete all as directed. Make for Item srl No : 21 to 26 - Havells/Standard/L&T/CG
Supply and fixing switch Air break Gang operated triple pole mechanically operated with GI operated rod, insulator (wire isulator type) and steel frame with operating mechanisim worked from ground level verticle/Horizontal type, for current rating upto 200 Amps, HT 11000 volts including locking arrangement with six lever lock and painting the steel surfaces with two coats of aluminimum paint over a coat of red oxide primer including taking down unserviceable switch air break complete all as directed.
Supply and install Horn gap fuse assembly (solid core insulator type) and steel frame etc suitable for HT 11000 Volts with HT fuse element upto 50 amps including taking down unserviceable fuse assembly complete all as directed.
Supply and fixing drop out expulsion fuse assembly single pole mounted on insulator (two isulator type) and steel frame etc suitable for HT 11000Volts grade with burried fuses & HT fuse element up to 50 Amps including taking down unserviceable drop out expulsion fuse assembly complete all as directed.
M&L for lightining arrestor for outdoor fuse expulsion type complete with all fittings, transmission class earthed system discharge capacity 65 KA suitable for 11000 volts grade including taking down unserviceable lightining arrestor complete all as directed. Make for item srl No 27 to 30 : OBLUM/British Electric/ LET/Lanco
M&L for Aluminum conductor, steel reinforced (ACSR) of size 6/2.11 mm (rapid) not exceeding 2 mtr long for jumper connection between lightning arrester and pin insulator, pin insulator and AB switch, AB switch and HG fuse, drop out expulsion to transformer, including necessary lugs, binding wire, heavy duty PG clamps, PVC sleeves with R, Y, B colour code inlcuding taking down unserviceable aluminium conductor complete all as directed. Make: - Raychem/Transpower/Denson
M & L danger notice plate of 1.6mm thick Mild steel sheet vitreous enameled white, with letters, figures and conventional skull and bones in signal red color and fixed with MS clamps, bolts and nuts of approved size for HT 25 x 20cm size including taking down unserviceable danger notice plate complete all as directed.
Servicing of 11000 Volts, 3 phase 50 HZ indoor type totally enclosed metal clad switchgear complete with Vacuum circuit breaker of rating upto 800 amps, any make by switch off the charging motor and discharge the spring energy storage mechanism by closing and opening the break once, cleaning of more strongly adhering contamination with slightly alkaline or rivolta BWR 210, wipe down after cleaning, using clean water and dry properly, relubricate(using Isoflex topas NB 52) of pawls, support shafts, sliding and rotate bearings surfaces, check the tightness of fastening bolts, replace spring lock washers, split pins and carbon brushes including testing complete all as directed. Note: The quoted rates shall be deemed to include the following: (i) Servicing of VCB shall be done by the technician from VCBs make. (ii) If any damage occured during servicing of VCB then the responsibility lies with the contractor for rectification without any extra cost. (iii) The required transportation, repairing tools shall be arranged by the contractor and the cost shall be included in the quoted rate.
Overhauling of transformer by disconnecting the HT and LT side supply, dismantling the clamps, bolts, nuts & washers, lifting the transformer from structure by using crane and transport to the workshop to carry out the repair by draining out the transformer oil through the drain plug, removing the top portion, lifting the primary and secondary winding without disturbing or damaging the core and the coil, clean the bottom portion of the transformer tank by removing the deposited material, clean and keep the primary and secondary winding with core in electric oven minimum for 48 hours to enhance the insulation valve of the windings, supply and fixing breather pipe and packing, silica jel, oil level indicating transperent glass with marking minimum and maximum oil level indication, HT and LT side bushes assembly, gaskets and oil seals set including taking down u/s items and reassembling the transformer, refilling the transformer oil, reinstallation, testing and commissioning of the transformer should be carried out at required locations as directed for the following capacities:
100 KVA to 160 KVA capacity transformer Make - Kirloskar/HIT
210 KVA to 315 KVA capacity transformer Transformer Make - Essenar/HIT Note: The rate quoted shall be deemed to include the following: (i) Overhauling of Transformer shall be done by the technician from transformers OEM. (ii) The required transportation, Crane, repairing tools shall be arranged by the contractor. (iii) De-hydration of the transformer oil should be carried out to improve BDV to withstand operational voltage before refilling (iv) Leak test to be carried out and rectified by brazing, welding etc before re-filling of the dehydrated transformer oil. (v) If any damage occured during repair/testing of transformer then the responsibility lies with the contractor for rectification without any extra cost. (vi) Standby distribution transformer shall be arranged by the contractor till the existing transformer is serviced/repaired.
Supply and filling of Transformer oil suitable for distribution of transformer with di-electric strength of BDV 60 KV complete including removal of unserviceable oil complete. Make - Poweroil/Castrol/Servo
Taking out the air compressor 2 HP capacity, 3 Phase, from site to workshop & back and taking out burnt copper winding from the motor and rewinding the motor with insulated copper wire as per existing gauge, varinishing, heating complete and replacement of the following spares in motor/compressor and re-assembling the motor/compressor after repair including scrubbing old paint and painting with two coats of machine paint over a coat of red oxide primer & filling of compressor oil upto its required level all as directed. (a) Air filter and line filter (b) Bearing for motor (c) Belt (d) Pressure gauge (e) Hose reel (f) Transfer tube and nylon tube (g) Safety relief valve & check valve
M&L for Plain Cement concrete 1:2:4 type B-2, (using 40mm graded aggregate) 100mm thick as in path/floor including demolition of old concrete and removal of debris outside MOD land complete all as directed.
Filtration of cooling/insulation oil of HT/LT transformer and carbon deposit from the oil through straight line oil filtration plant, extracting the moisture contents and shall withstand 40 KV for one minute dielectric strength, testing the oil for dielectric strength and acidity before and after filtration and submitting the test result all as directed including topping up of the oil in the transformer of Capacity 100 KVA (Pratap Colony) Note: - For topping up of the transformer oil will be measured and paid separately.
All as per srl item no. 38 here in before but for Transformer of capacity 160 KVA (SERA)
All as per srl item no. 38 here in before but for Transformer of capacity 210 KVA ( CE (R&D) Office Complex & VVRA).
All as per srl item no. 38 here in before but for Transformer of capacity 250 KVA ( Diber & CE (R&D) Residential Area)
All as per srl item no. 38 here in before but for Transformer of capacity 315 KVA (DMDE)
Cleaning thoroughly the steel street light poles of any height and any description (Maximum 9 Mtr long) scrapping on old paint, dirt/rust carefully and applying one coat of aluminium paint marking of zebra crossings up to a height of 1.0 meter above the coping with black and yellow strips of synthetic enamel paint including writing pole numbers and colour washing to pole coping complete all as directed. Make : Asian/Shalimar
S&F following items suitable for existing full height single lane turnstile of size 1500x1500x2000mm & tripod turnstile of 500mm walkway including fixing accessories and taking down unserviceable items complete all as directed.
Adaptor 24V DC input
IC (Integrated Ciruit)
Push button element with enclosure
Control Panel
Sensor
S&F security light fitting bracket made out of GI tubing 40mm dia light grade of size 1.5m long, bent to shape including clamp for bracket made out of 50x6mm MS flat iron with necessary nut & bolts, washers complete and taking down unserviceable bracket complete all as directed. Make : Tata/Jindal/Oswal
S&F Pole junction box, made up of sheet moulding compound (SMC) type with hinged type door and locking arrangement, white colour of size 280x170x130mm outside and 240x130x110mm internal dimensions comprising 01 No-16 Amps capacity kitkat fuse, aluminium busbar-04 Nos, earthing terminals, bolts & nuts and connecting up cables with aluminium terminal lugs including suitable size clamps,bolts, nuts and washers fixed on pole complete and taking down unserviceable junction box complete all as directed Make - Sintex or equivalent ISI marked
M&L for GI water tubing of 80mm bore 'Medium Grade' with all fittings such as elbow, socket, tee, union and nipples etc, including cutting, threading etc, laid in trenches or fixed to walls complete including taking down unserviceable water tubing complete all as directed.
All as per srl item No.47 here-in-before but of 65 mm bore complete.
All as per srl item No.47 here-in-before but of 50 mm bore complete.
All as per srl item No.47 here-in-before but of 40 mm bore complete.
All as per srl item No.47 here-in-before but of 32 mm bore complete.
All as per srl item No.47 here-in-before but of 25 mm bore complete.
All as per srl item No.47 here-in-before but of 20 mm bore complete.
All as per srl item No.47 here-in-before but of 15 mm bore complete. Make for srl item No 47 to 54 : Jindal/Tata/Zenith
Supply and fixing in repairs GI small fittiings such as socket, elbow, nipple of any length, tee, reducer, dummy plug etc for galvanised iron 15mm bore pipe complete all as specified as directed. Note : Taking down and refixxing of old GI tubing upto 1.5m included in rates.
All as per srl item No.55 here-in-before but of 20 mm bore complete.
All as per srl item No. 55 here-in-before but of 25 mm bore complete.
All as per srl item No. 55 here-in-before but of 32 mm bore complete.
All as per srl item No. 55 here-in-before but of 40 mm bore complete.
All as per srl item No. 55 here-in-before but of 50 mm bore complete.
Supply and fixing in repairs GI small fittiings such as union iron 15mm bore pipe complete all as specified as directed.
Supply and fixing in repairs GI small fittiings such as union iron 20mm bore pipe complete all as specified as directed.
Supply and fixing in repairs GI small fittiings such as union iron 25mm bore pipe complete all as specified as directed.
Supply and fixing in repairs GI small fittiings such as union iron 40mm bore pipe complete all as specified as directed.
Supply and fixing in repairs GI small fittiings such as union iron 50mm bore pipe complete all as specified as directed.
Cutting of GI pipe of any size from site to work shop and making threads of GI pipe and reassemble of same location after threading complete all as specified as directed.
S&F for Brass, globe or gate valves of size 65 mm bore with all fittings, iron wheel head,screwed both ends for iron pipe and fixed including taking down unserviceable gate valve complete all as directed.
All as per srl item No.67 here-in-before but of 50 mm bore complete.
All as per srl item No.67 here-in-before but of 40 mm bore complete.
All as per srl item No.67 here-in-before but of 32 mm bore complete.
All as per srl item No.67 here-in-before but of 25 mm bore complete.
All as per srl item No.67 here-in-before but of 20 mm bore complete.
All as per srl item No.67 here-in-before but of 15 mm bore complete.
S&F Brass foot valve of 65mm dia with all fittings, screwed both ends for iron pipe and fixed including taking down unserviceable Foot valve complete all as directed.
All as per srl item No.74 here-in-before but of 50 mm dia complete.
S&F Brass Non return valve of 50mm dia with all fittings screwed both ends for iron pipe and fixed complete including taking down unserviceable Non return valve complete. Make for srl item No. 67 to 76: ZOLOTO/ LEADER/PRAYAG
M and L for dismantling old valve chamber and material and labour for construction of brick masonry new valve pit chamber of size 900mmx900mmx900mm (internal), 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate, providing with old size fly ash bricks masonry wall of 230mm thick built in CM 1:6, rendering 15mm thick in CM 1:6 finished even and smooth using extra cement internally and 20mm thick in CM 1:4 and finished fair and even externally and plaster shall be done 150 mm below ground level, supply and fix 2.00 mm thick MS sheet steel cover fixed on 45x45x5 mm angle iron frame embedded in PCC 1:2:4 coping with locking arrangement and MS hold fast and handle made out of 25x6mm flat iron, applying two coats of synthetic enamel paint of approved shade over a coat of primer (red oxide) to all exposed steel surfaces and applying three coats of white wash to exposed plastered surfaces (internal and external) and making good all disturbed suface to match surrounding complete all as specified and as directed .
S&F following items suitable for existing solar power light system including fixing accessories and taking down unserviceable items complete all as directed.
CFL 11 Watt, 4 Pin with holder Make : Philips/Bajaj/Wipro
Sealed maintenance free battery 12V,65AH Make : Exide/Amaron
Servicing of photo voltic cell (panel)
Dismantling of old unserviceable Panel and Supply & fabrication of LT Panel Board EACH CPRI approved cubical type made of 2 mm thick sheet steel indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Aluminium bus bar of 500 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No. CTs of suitable ratio, and Indicating LED type lamp for Red,Yellow and Blue in comer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations of suitable size,testing and commissioning complete and consisting following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work. (a) MCCB 4 Pole 250 Amps 25KA -01 No. (as Incoming) (b) MCCB 4 Pole 100 Amps 16KA -06 No. (as Outgoing) Make-Standard/C&S/Havel
Servicing and load testing of 1 ton single girder EOT Crane including scrubbing old paint and painting with two coats of spray paint over a coat of red oxide primer complete all as directed. Note: The following items for crane testing shall be arranged by the contractor and the cost shall be deemed to be included in the quoted rate. (i)Test Loads (ii) Deflection gauge (iii) Wire rope slings (iv) Tools & tackles (v) Transportation
S&F LED street light luninaires 60 Watt with pressure die cast aluminium housing , Heat resistant toughened glass with frame and IP 66 protection including taking down old unserviceble fitting of any type complete all as directed. Make: Crompton Cat part No. LSTP - 60 -CDL /Equivalent in Philips/Havells
S&F LED street light luninaires 120 Watt with pressure die cast aluminium housing , Heat resistant toughened glass with frame and IP 66 protection including taking down old unserviceble fitting of any type complete all as directed. Make: Crompton Cat part No. LSTP - 60 -CDL /Equivalent in Philips/Havells
S&F LED flood light 120 Watts IP-65 complete all as speciifed and directed. WIPRO cat Part No : LF20-342-060-57-G2 or Equivalent including taking down old unserviceble fitting of any type complete in Philips/Bajaj/CG
S&F LED flood light 250 Watts IP-65 complete all as speciifed and directed. WIPRO cat Part No : LF20-342-060-57-G2 or Equivalent including taking down old unserviceble fitting of any type complete in Philips/Bajaj/CG
S&F LED 40W suitable for pole dia upto 65mm post top made in case aluminium spigot housing with decorative clear opal acrylic diffuser and IP65 protection including all fixing accessories like flexible cable 3 x 2.5 sqmm with connector etc and taking down unserviceable light fitting complete all as directed. Make:- Model No.CELESTA CAT Part No.BGCL 40 W LED of Bajaj or equivalent in Havells/Philips/Wipro
S&F LED spot light 6 x LED over PCC base with easy to install and high ingress protection including equipped with suitable mounting options including taking down old unserviceable fitting complete all as specified and directed. Make : Model No. BGP 310 6xLED-HP / WW 220-240 V 12 IN of Philips or techno-commercially equivalent model in Wipro / Havells.
Material and labour for Cleaning of RCC Over Head Reservoirs 50000 Ltrs capacity as described below a) Before starting the cleaning of Over Head Reservoir, distribution line from OH tank is be disconnected and plugged with suitable fitting. After cleaning, plugged line should be washed and connected to the distribution pipe line as per existing position. Cost of earthwork and excavation work required if any shall be included in the quoted rate. b) The inner surface of the walls and ceiling of the tank shall be cleaned with high pressure jet pump after emptying the water in the tank c) After thorough cleaning of the tank, the cleaning water and sludge is to be removed by using pump and the sludge has to be disposed off at place as directed. d) After removing the sludge from tank the tank shall be cleaned thoroughly by using high pressure water pump first and again the floor and inner surfaces of the tank shall be cleaned by using a industrial vaccum cleaner and the tank shall be made fully dirt free. e) After the tank is made dirt free, the inner surfaces of walls and ceiling of the tank shall be treated with anti bacterial agents. f) After the treatment as mentioned at (e) above, the inner surfaces of walls and ceiling shall be treated with UV Radiator.
g) After complete treatment, all pipes such as inlet, over flow, delivery and wash out, shall be painted with two coats of synthetic enamel paint after thoroughly cleaning the surfaces and writing 'Date of cleaning and due date of cleaning on wall complete all as directed.
All as per srl item No.87 here-in-before but cleaning of RCC under ground sump complete of the following capacities :-
Under ground sump of capacity 45000 Ltrs
Under ground sump of capacity 25000 Ltrs Note for srl item No 87 & 88 : The unit rate quoted deemed to include the draining of water with mechanical equipment and working condition in water and mud etc. (ii) The rate quoted by contractor is deemed to include all for safety precautions which shall be taken while working on RCC over head tank / underground sump and contractor or his Engineer shall be available during execution of the said job. (iii) Lighting arrangements if required to be provided by the contractor temporarily at his own arrangements and the amount quoted is deemed to be inclusive of above provision. Electricity / diesel shall not be provided by the Department. (iv) Contractor shall complete work in one day to do the work inside each OH Tank / UG sump so as to have an un interrupted water supply to the users.
Taking out submersible pump set of 5HP capacity with 50mm dia GI column pipes from the bore well of depth upto 230 metres for carrying out repairs and lowering the same in position and commissioning after carrying out the repairs as required including testing complete all as directed.
M&L for Development of tube well by compressed air 21 - 25 PSI up to 230 mtr deep and afterwards with 25% extra capacity pump by pumping muddy water till clear water is received complete all as specified and as directed. NOTE: The rate quoted shall be deemed to include :- (i) levelling of ground for vehicle movement and site clearance after tubewell development. (ii) Any damage that caused during development of tubewell shall be made good by contractor without extra cost to department.
Removing old unserviceable column pipe as obtained from taking down of submersible pump set and S&F new GI column pipe 50mm dia heavy duty with GI socket, 3 metre length each including both ends machine threaded with long threaded socket complete all as directed. Make : Zenith/Tata/Jindal Note: 3 Mtrs pipe, both side threaded socket shall be measured as one unit
Supply and laying PVC insulated, water proof cable PVC sheathed, Multistranded copper conductor 1100V, 3 core, 6 sqmm flat cable suitable for submersible pump and connecting with necessary ferrules/water proof joints complete including taking down unserviceable cable all as directed Make : Finolex/Universal/Havells/Polycab
Taking the submersible pump set of 5 HP capacity from site to workshop and back and dismantling of pump set at workshop overhauling including replacement of worn out spares and re-assembling the pump set after repair including scrubbing old paint and applying two coats of machine paint over a coat of red oxide primer and testing complete all as directed. Note: Supply only spares shall be measured and paid for separately.
Supply only following spares suitable for submersible pump sets 7.5 HP to 12.5 HP capacity complete all as directed.
Stainless steel pump shaft
Gun metal pump driven end bush
Gun metal impeller
Thermoplastic impeller
Gun metal seal ring
Cast iron bowl assembly
Stainless steel pump shaft key
Stainless steel bush for coupling of motor and pump
Taking the submersible motor of submersible pump set of 5 HP capacity from site to workshop and back and taking out burnt copper winding from the motor at workshop and rewinding the motor with insulated copper wire as per exisitng gauge & turns, varnishing, heating complete including repalcement of the following spares and reassembling the motor after repair including testing complete all as directed. (a) Bushing of motor both side-2Nos (b) Motor shaft stainless steel-1No (c) Sand Guard for motor.-1No (d) Thrust bearing for motor.-2Nos (e) Thrust plate for motor.-2Nos
Taking the Open well submersible motor of submersible pump of 5 HP capacity from site to workshop and back and taking out burnt copper winding from the motor at workshop and rewinding the motor with insulated copper wire as per exisitng gauge & turns, varnishing, heating complete including repalcement of the following spares and re-assembling the motor after repair including testing complete all as directed by the Engr in Charge. (a) Bushing of motor both side-2Nos (b) Motor shaft stainless steel-1No (c) Sand Guard for motor.-1No (d) Thrust bearing for motor.-2Nos (e) Thrust plate for motor.-2Nos
Taking the Centrifugal pump set of 5 HP capacity from site to workshop & back and taking out burnt copper winding from the motor and rewinding the motor with insulated copper wire as per existing gauge, varinishing, heating complete, including replacement of the following spares and re-assembling the motor after repair including scrubbing old paint and applying two coats of machine paint over a coat of red oxide primer all as directed. (a) Gun Metal Bush- 2 Nos (b) Bearing for motor - 2 Nos (c) Gland packing - Set
Supply and fixing DOL starter suitable for 7.5 HP capacity motor rating AC-3 duty, 415V, 50HZ, 3Ph with sheet steel enclosure including fixing accessories complete and taking down unserviceable starter complete all as directed by Engr in Charge. Make - L&T/SIEMENS/C&S/GE/CG
Supply and fixing Fully automatic star delta starter suitable for 5 HP capacity motor rating AC-3 duty, 415V, 50HZ, 3Ph with sheet steel enclosure including fixing accessories complete and taking down unserviceable starter all as directed. Model - MK 1F of L&T or equivalent in SIEMENS/C&S/GE/CG
S&F Plain, black mild steel sheet of thickness 1.25mm in stepped flashings (measured as the minimum rectangle from which the pieces can be cut) including applying of 2 coats of synthetic enamel paint over a coat of primer and taking down of existing MS sheet complete all as directed.
Taking out water sample in clean container from borewell and Manjeera in different loaction under AGE B/R secunderabad and getting the same tested from the Govt approved laboratory for bacteriological and chemical test complete all as directed.
Re-conditioning of batteries including replacement of terminal post, burnt out lead cells and electrolyte acid for the capacity of battery 180 AH, 12V complete all as directed. Make : Exide/Amaron
Supply only Altoch GP (Calcium based granular disinfectant for water treatment) complete all as directed Make :Potter & Watt corporation or Equivalent
S&F rigid non-metallic PVC conduit of 40 mm dia inclusive of all bend, tees, elbows, reducers, bell mouth tube ends and fixing accessories such as coupllers, lock nuts, saddles, pipe hooks etc including taking down old unserviceable pipe complete all as specified and directed. Make: Prince/Kissan/Sudhakar/Finolex
S&F rigid non-metallic PVC conduit of 50 mm dia inclusive of all bend, tees, elbows, reducers, bell mouth tube ends and fixing accessories such as coupllers, lock nuts, saddles, pipe hooks etc including taking down old unserviceable pipe complete all as specified and directed. Make: Prince/Kissan/Sudhakar/Finolex
S&F in repairs bus bar chambers wall/pole/angle iron based mounted of capacity 100 Amps 8 way with necessary connecting arrangement like clamp, angle iron , nuts & bolts etc complete all as directed.
S&F in repairs bus bar chambers wall/pole/angle iron based mounted of capacity 200 Amps 6 way with necessary connecting arrangement like clamp, angle iron , nuts & bolts etc complete all as directed.
S&F Air termination point vertical type single pointed made with 12mm dia 300mm long aluminium rod including necessary fixing arrangement with aluminium boits, nuts,lead wasters etc. complete and incl provisin of GI tubing grade 40mmdia,300mm long embedded in PCC block (size 30cm X30cm X 30cm) one end and other end fitted with air termination rod incl taking down old termination rod complete all as specified and directed.
S&F aluminium strip of size 25 x 3.15 mm horizontal/ Vertical down conductors and incl epoxy insulator bus bar type 40mm thick at an interwal of 60 cm apart for lightening protection on roof and for down conductors including all fixing arrangments with aluminium nuts, bolts & washers complete all as per IS-2309-1989 and testing incl taking down old aluminium strip all as specified.
S&F in repairs test point terminal block made out of gun metal or phosphorus bronze of size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25mm long hex head screw for fixing the same on wall as directed at site.
S&F Galvanised from strip of size 32 x 6 mm from earth pit to test point provided all around the bldg for lightening protection laid in trenches /fixed to walls on eposy insulators with screws etc and connecting up incl taking down old galvanised strip complete all as directed.
S&F Change over switch 630 amps, four pole, 415 Amps with all accessories, enclouser & suitable lugs including taking down old unserviceable complete all as specified.
M&L for earthing complete with GI earth plate electrode 600x600x6mm buried directly in ground vertically to a depth of not less than 2.25mtr below ground level connected to GI wire 4 mm by means of bolts washers etc made out of GI earth wire will be protected by galvanized iron pipe medium grade 15mm bore up to main distribution board/main switch including necessary excavation and earth work PCC 1:3:6 type CI (using 20mm graded stone aggregate) RCC cover 1:2:4 type B1 including necessary reinforcement etc complete all as shown on electric plate No.3 of MES Such Part-I., including removal of old earthing and as directed by Engineer-in-Charge.
M.R.ENTERPRISES
M/s. A&T Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .