| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.7 LAccepted-AOC 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L1 | Accepted-AOC Being lowes | |
| 2 | L2₹50.0 L+₹9.1 L (22.3%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹50.5 L+₹9.6 L (23.5%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance Other than being lowest | |
| 4 | l4₹63.6 L+₹22.7 L (55.6%)Rejected-Finance 16 18 2ND SURTI CHEMBER DHOBI TALAO LANE MUMBAI MUMBAI MAHARASHTRA 400002 | MUMBAI | MAHARASHTRA | 400002 | l4 | Rejected-Finance Other than being lowest |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
18 Sept 2024, 6:50 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR /MAINT OF LT/HT CAPACITORS BANKS ETC AT NAVAL DOCKYARD UNDER GE (NW) MUMBAI, COLABA, MUMBAI
2024_MES_667381_1
8363/CWE (NW) Mumbai/E8
Open Tender
Civil Works
Item Rate
365 days
GE (NW) Kunjali
Class C
Category B (i)
7 documents required · 7 mandatory
₹1,000
GE (NW) Kunjali
₹1.4 L
16 Nov 2024
22 Jul 2024
21 Sept 2024
22 Jul 2024
18 Sept 2024
12 Aug 2024
22 Jul 2024 - 10 Aug 2024
Amount
Comprehensive maintenance of LT Automatic Power Factor Correction (APFC) panel, monthly basis of of capacity 150 KVAR- 06 Nos complete comprising capacitor having low watt loss, thyristor/contactor, APFC relay, MCCB, Cooling fan, Voltmeter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning all contact points, tightening of all connections, busbar including replacement of minor components like thimbles, nuts, bolts and washers, busbar sleeves, etc if necessary, cleaning the entire panel by using hot blower complete all as specified and directed by Engineer-in-Charge
All as per item No 1.00 but of capacity 200 KVAR- 02 Nos complete all as specified and directed by Engineer-in-Charge
All as per item No 1.00 but of capacity 210 KVAR- 02 Nos complete all as specified and directed by Engineer-in-Charge
All as per item No 1.00 but of capacity 300 KVAR- 04 Nos complete all as specified and directed by Engineer-in-Charge
All as per item No 1.00 but of capacity 600 KVAR- 04 Nos complete all as specified and directed by Engineer-in-Charge
All as per item No 1.00 but of capacity 650 KVAR- 01 No complete all as specified and directed by Engineer-in-Charge
All as per item No 1.00 but of capacity 800 KVAR- 02 Nos complete all as specified and directed by Engineer-in-Charge
All as per item No 1.00 but of capacity 950 KVAR- 02 Nos complete all as specified and directed by Engineer-in-Charge
Comprehensive maintenance of LT Fixed type Capacitor Banks, monthly basis of capacity 25 KVAR - 04 Nos complete comprising capacitor having low watt loss, SFU, Fuses with all other connected accessories, checking of serviceability of Each component, cleaning all contact points, tightening of all connections, busbar including replacement of minor components like thimbles, nuts, bolts and washers, busbar sleeves, etc if necessary, cleaning the entire panel by using hot blower complete all as specified and directed by Engineer-in-Charge
All as per item No 9.00 but of capacity 50 KVAR- 04 Nos complete all as specified and directed by Engineer-in-Charge
All as per item No 9.00 but of capacity 75 KVAR - 01 No complete all as specified and directed by Engineer-in-Charge
Notes for item No 1.00 to 11.00: (i)The quoted rates are inclusive of the cost of replacement of all spare parts and accessories inclusive of nuts, bolts & washers, thimbles used while servicing the APFC panels as directed by the Engr-in-charge. (ii) The tools required shall deemed to be included in the above quoted rate. (iii) Spares for unserviceable components to be replaced shall be measured and paid separetely. (iv) If the contractor has failed to carry out the monthly servicing of the panel, a penalty of double the quoted rate will be recovered. (v) Contractor must ensure that the APFC panel shall be functional through out the contract period and power factor reading shall not fall under 0.95 PF (vi) Contractor shall submit a monthly maintenance programme with location to the Engr-in-charge and the maintenance shall be carried out in the presence of JE/Engr-in-Charge with out fail.
Supply only APFC relay, 8 Stage, auto set function, having digital display, existing make etaSMART of L&T Cat Part No CS90902OOOO or equivalent in complete all as specified and directed by Engineer-in-Charge
Supply only APFC relay, 12 Stage, auto set function, having digital display, existing make etaSMART of L&T Cat Part No CS90903OOOO or equivalent in complete all as specified and directed by Engineer-in-Charge
Supply only APFC relay, 16 Stage, auto set function, having digital display, existing make etaSMART of L&T Cat Part No CS90905OOOO or equivalent in complete all as specified and directed by Engineer-in-Charge
Supply only capacitor duty contactor of existing make L&T Cat Part No CS96156 or equivalent suitable for upto 10 kVAR rating with 2 NO 2 NC add on block, complete all as specified and directed by Engineer-in-Charge
Supply only capacitor duty contactor of existing make L&T Cat Part No CS90019 or equivalent suitable for upto 15 kVAR rating with 2 NO 2 NC add on block, complete all as specified and directed by Engineer-in-Charge
Supply only capacitor duty contactor of existing make L&T Cat Part No CS96322 or equivalent suitable for upto 25 kVAR rating with 2 NO 2 NC add on block, complete all as specified and directed by Engineer-in-Charge
Supply only capacitor duty contactor of existing make L&T Cat Part No CS96324 or equivalent suitable for upto 50 kVAR rating with 2 NO 2 NC add on block, complete all as specified and directed by Engineer-in-Charge
Supply only Power contactor MNX70 type of existing make L&T Cat Part No CS97076 or equivalent suitable for upto 25 kVAR rating with 2 NO 2 NC add on block complete all as specified and directed by Engineer-in-Charge
Supply only Power contactor MNX110 type of existing make L&T Cat Part No CS94137 or equivalent suitable for upto 50 kVAR rating complete all as specified and directed by Engineer-in-Charge
Supply only Power contactor MNX185 type of existing make L&T Cat Part No CS94139 or equivalent suitable for upto 75 kVAR rating complete all as specified and directed by Engineer-in-Charge
Supply only HRC fuse 6-32 Amps, with Fuse holders & Fuse bases complete all as specified and directed by Engineer-in-Charge
Supply only HRC fuse 63 Amps, existing make L&T Cat Part No SF94027 or equivalent complete all as specified and directed by Engineer-in-Charge
Supply only HRC fuse 80 Amps, existing make L&T Cat Part No SF94028 or equivalent complete all as specified and directed by Engineer-in-Charge
Supply only HRC fuse 100 Amps, existing make L&T Cat Part No SF94029 or equivalent complete all as specified and directed by Engineer-in-Charge
Supply only LED indicator lamp (RED, YELLOW, GREEN), complete all as specified and directed by Engineer-in-Charge
Supply only LED indicator lamp (BLUE) complete all as specified and directed by Engineer-in-Charge
Supply only push button of any colour with NO / NC Element complete all as specified and directed by Engineer-in-Charge
Supply only PVC Cooling fan for APFC panel as per sample , complete all as specified and directed by Engineer-in-Charge
Supply only MCCB, Three pole, 125 Amps with thermal magnetic release with range 100-125 Amp, having breaking capacity 36 KA ,existing make L&T Cat part No CM92008OOL1OG or equivalent complete all as specified and directed by Engineer-in-Charge
Supply only MCB, DP 0.5 to 4 Amp, 10 kA "C" curve, 230 volt AC ,complete all as specified and directed by Engineer-in-Charge
Supply only MCB TP 6-32 Amps,10KA complete all as specified and directed by Engineer-in-Charge
Supply only MCB TP 40-63 Amps,10KA complete all as specified and directed by Engineer-in-Charge
Supply & fixing of Auto/ Manual Switch complete all as specified and directed by Engineer-in-Charge
Supply only copper wound detuned reactors 7%, 3 phase, 440 Volts, 10 kVAR rating, suitable for fixing with the existing capacitor bank panel complete all as specified and directed by Engineer-in-Charge
Supply only detuned reactors 7%, 3 phase, 440 Volts, 15 kVAR rating, suitable for fixing with the existing capacitor bank panel complete all as specified and directed by Engineer-in-Charge
Supply only detuned reactors 7%, 3 phase, 440 Volts, 25 kVAR rating, suitable for fixing with the existing capacitor bank panel complete all as specified and directed by Engineer-in-Charge
Supply only detuned reactors 7%, 3 phase, 440 Volts, 50 kVAR rating, suitable for fixing with the existing capacitor bank panel complete all as specified and directed by Engineer-in-Charge
Supply only detuned reactors 7%, 3 phase, 440 Volts, 100 kVAR rating, suitable for fixing with the existing capacitor bank panel complete all as specified and directed by Engineer-in-Charge
Supply only detuned reactors 7%, 3 phase, 440 Volts, 150 kVAR rating, suitable for fixing with the existing capacitor bank panel complete all as specified and directed by Engineer-in-Charge
Supply only in replacement capacitor 10 kVAR Cylindrical Type Capacitor existing Make L&T make (LTCCU) 440 volts 3 phase or equivalent complete all as specified and directed by Engineer-in-Charge
Supply only capacitor 15 kVAR Cylindrical Type Capacitor existing Make L&T make (LTCCU) 440 volts 3 phase or equivalent complete all as specified and directed by Engineer-in-Charge
Supply only capacitor 25 kVAR Cylindrical Type Capacitor existing Make L&T make (LTCCU) 440 volts 3 phase or equivalent complete all as specified and directed by Engineer-in-Charge
Supply only capacitor 10 kVAR APP Box Type Capacitor existing Make L&T make (LTBCP) 440 volts 3 phase or equivalent complete all as specified and directed by Engineer-in-Charge
Supply only capacitor 20 kVAR APP Box Type Capacitor existing Make L&T make (LTBCP) 440 volts 3 phase or equivalent complete all as specified and directed by Engineer-in-Charge
Supply only capacitor 25 kVAR APP Box Type Capacitor existing Make L&T make (LTBCP) 440 volts 3 phase or equivalent complete all as specified and directed by Engineer-in-Charge
Supply & fixing control wiring of the panel (including wire) complete all as specified and directed by Engineer-in-Charge
Supply & fixing Power wiring of the panel (including wire) complete all as specified and directed by Engineer-in-Charge
Supply & fixing NDR Relay complete all as specified and directed by Engineer-in-Charge
Supply & fixing MNX12A Power Contactor with 1 NC 230 V AC Coil complete all as specified and directed by Engineer-in-Charge
Supply & fixing Add on Block 2 NO 2 NC complete all as specified and directed by Engineer-in-Charge
Supply & fixing MNX12A Power Contactor with 1 NO 230 V AC Coil complete all as specified and directed by Engineer-in-Charge
Supply & fixing Add on Block 4 NC complete all as specified and directed by Engineer-in-Charge
Supply & fixing On delay Timer 3 Sec. to 30 Hr. complete all as specified and directed by Engineer-in-Charge
Supply & fixing VC Card complete all as specified and directed by Engineer-in-Charge
Supply & fixing 6A SP MCB complete all as specified and directed by Engineer-in-Charge
Supply & fixing Red Illuminited Push Button complete all as specified and directed by Engineer-in-Charge
Supply & fixing Green Illuminited Push Button complete all as specified and directed by Engineer-in-Charge
Supply & fixing NO Element complete all as specified and directed by Engineer-in-Charge
Supply & fixing NC Element complete all as specified and directed by Engineer-in-Charge
Supply & fixing Red Indicating Lamps 230 V AC complete all as specified and directed by Engineer-in-Charge
Supply & fixing Yellow Indicating Lamps 230 V AC complete all as specified and directed by Engineer-in-Charge
Supply & fixing Blue Indicating Lamps 230 V AC complete all as specified and directed by Engineer-in-Charge
Supply & fixing 25 A, 7.2 KV HT HRC Fuse Links - BDGHC7.2KV (L-420 mm) complete all as specified and directed by Engineer-in-Charge
Supply & fixing 71 A, 7.2 KV HT HRC Fuse Links - BDGHC7.2KV (L-420 mm) complete all as specified and directed by Engineer-in-Charge
Supply & fixing 50 A, 7.2 KV HT HRC Fuse Links - BDGHC7.2KV (L-420 mm) complete all as specified and directed by Engineer-in-Charge
Supply & fixing 20 A FUSE BASE WITH 4 A FUSE LINK complete all as specified and directed by Engineer-in-Charge
Supply & fixing 8 Pin Relay 12A, 250 V Ac complete all as specified and directed by Engineer-in-Charge
Supply & fixing HT 1Ph., 0 to 400 A Analog Ammeter (200/ 5 A) complete all as specified and directed by Engineer-in-Charge
Supply & fixing Aux. Relay complete all as specified and directed by Engineer-in-Charge
Supply & fixing HOOTER 230 V AC complete all as specified and directed by Engineer-in-Charge
Supply & fixing HT Cap. 129 KVAR, 1Ph., 4.457 KV, 50 Hz (L350,W130,H330) complete all as specified and directed by Engineer-in-Charge
M/s S.D Construction Co (BID ID -3092505)
Shree Ayyappa Engineering (BID ID -3093020)
Nayana Electric Corporation (BID ID -3085610)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .