Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 1ST FLOOR SIDHARTH TOWER BALTI KHARKHANA BYELNE S J ROAD ATHGAON GUWAHATI KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | Admitted-Finance |
| 2 | Admitted-Finance 67D EXECUTIVE PO IZZAT NAGAR SUNCITY VISTAR BAREILLY UTTAR PRADESH 243122 | BAREILLY | UTTAR PRADESH | 243122 | Admitted-Finance |
| 3 | Admitted-Finance 18 19 MUNESWAR PURAM PARA ALAMNAGAR BIHIND ROSE CHILDREN ACADEMIC LUCKNOW UTTAR PRADESH 226017 | LUCKNOW | UTTAR PRADESH | 226017 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
15 Jan 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC Shahjahanpur
Electy. Trans. Circle Shahjahanpur
Work
2024_UPTCL_988317_1
30 ETC(S)/2024-25
Open Tender
Electrical Works
Fixed-rate
60 days
Hardoi
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
A/c No. 0423002100107147 IFSC Code No. PUNB0042300
₹10,000
21 Mar 2025
30 Dec 2024
16 Jan 2025
30 Dec 2024
15 Jan 2025
30 Dec 2024
30 Dec 2024 - 15 Jan 2025
Amount
Supply of Bolted type Single Tension Fitting Assembly with Turn Buckle, suitable for Twin / Bundle ACSR Moose/Zebra Conductors complete with Hardware Fittings, D-Shackle, Socket Eye, Ball Hook, Yoke Plate, D-Clip, Tension Clamp etc., as per Drawing / Sample.
Supply of Bolted type Single Tension Fitting Assembly without Turn Buckle, suitable for Twin/Bundle ACSR Moose/Zebra Conductors complete with Hardware Fittings, D-Shackle, Socket Eye, Ball Hook, Yoke Plate, D-Clip, Tension Clamp etc., as per Drawing / Sample.
Supply of Bolted type Single Suspension Fitting Assembly suitable for Twin / Bundle ACSR Moose/Zebra Conductors complete with Hardware Fittings, Socket Eye, Ball Hook, Yoke Plate, J-Hook etc., as per Drawing / Sample.
Supply of PG Clamp duly made of LM-6 Aluminium Alloy, suitable for ACSR Zebra to ACSR Zebra Conductor complete with 3 No. 16 × 75 mm size G.I. Bolts, Nuts, Spring & Plain Washers, as per Drawing / Sample.
Supply of 33KV Bi-metallic Isolator Clamp Suitable for Twin Moose Conductor
Supply of Spacer suitable for 33KV Bus Bars of Twin / Bundle ACSR Moose Conductors with 250 mm Spacing and duly made of LM-6 Aluminium Alloy complete with 12 mm dia. HDG Bolts, Nuts, Spring & Plain Washers, as per Drawing / Sample.
Supply of Spacer suitable for 33KV Bus Bars of Twin / Bundle ACSR Panther Conductors with 100 mm Spacing and duly made of LM-6 Aluminium Alloy complete with 12 mm dia. HDG Bolts, Nuts, Spring & Plain Washers, as per Drawing / Sample.
Supply of Flexible Copper Bond 20mm dia 500mm lenth including both side copper lug and M12 GI Nut-bolt & washers.
Supply of 40mm MS rod for Main Earthmat
Supply of Sand Bucket Stand suitable for 10 Nos. sand bucket as per technical specification.
Supply of Sand Buckets as per technical specification.
Supply of Electrod, MS, 40 mm 3 Meter long.
Opening of existing Jumpers of ACSR Moose / Panther Conductors between old 33KV Main Bus Bar to Main Bus Isolators; between 33KV Main Bus Isolator to C.B., 33KV C.B. to CTs in 33KV side of Transformers / 33KV Feeders Bays, 33KV Bus Section Isolator to 33KV Main Bus, 33KV Main Bus to 33KV Bus PTs & Bus LAs at 132KV Sub Station, Shahabad alongwith Shifting of the old Conductors, Clamps, Connectors etc. from Switchyard to Stores at the Sub Station.
De-Stringing & Dismantling of existing 33KV Main Bus Bar of Single ACSR Moose Conductors including De-hoisting of Disc Insulator Tension String with associated Tension Fitting and Disc Insulator Suspension String with associated Suspension Fitting from Gantry at 132KV Sub Station, Shahabad alongwith Shifting of the old Conductors, Tension / Suspension Fittings, P.G. Clamps etc. from Switchyard to Stores at the Sub Station. (1 Job for each Phase of each Section of the Main Bus Bar)
Dismantling of ALP/ABL etc Structure /Outdoor ACDB
Dismantling of Rail pole structure
Dismantling of 36KV BI/LI/Fuse set
Laying & Re-Stringing of 33KV Main Bus Bar of Twin / Bundle ACSR Moose/Zebra Conductors including Hoisting of Disc Insulator Tension String with associated Tension Fitting and Disc Insulator Suspension String with associated Suspension Fitting at 132KV Sub Station, Shahabad alongwith Shifting of the Conductors, Tension / Suspension Fittings, Spacers, Clamps etc. from Stores at the Sub Station to Switchyard. (1 Job for each Phase of each Section of the Main Bus Bar)
Jumpering with Twin ACSR Moose / Panther Conductors between newly laid 33KV Twin / Bundle ACSR Moose/Zebra Conductors Main Bus Bar & Transfer Bus Bar to Bus/Transfer Isolators; between 33KV Main Bus Isolator to C.B., 33KV C.B. to CTs in 33KV side of Transformers / 33KV Feeders Bays; 33KV Bus Section Isolator to 33KV Main Bus, 33KV Main Bus to 33KV Bus PTs & Bus LAs at 132KV Sub Station, Shahabad by due Cutting & Bending of Conductors and Tightening of the Conductors, Clamps, Connectors etc. alongwith Shifting of the Conductors, Equipments Connectors, P.G. Clamps etc. from Stores at the Sub Station to Switchyard.
Fixing of 250 mm Spacing Spacers between above Twin / Bundle ACSR Moose Conductors 33KV Main Bus Bar.
Fixing of 100 mm Spacing Spacers between above Twin / Bundle ACSR Panther Conductors 33KV Jumpers.
Safe Loading of 1 No. Drums of ACSR Zebra Conductor on suitable Vehicle after due Shifting from Storage Place to Loading Place at 132KV Sub-station, Shahabad. (1 Job per Drum)
Safe Carriage of above ACSR Zebra Conductor in Drums, Loaded on the Vehicle arranged by the Contractor from various sub-stations within ETC, Shahjahanpur to Safe Unloading Place at Existing 132/33KV Sub Station Shahabad (Approx. Distance 120 Km).
Safe Unloading of above ACSR Moose/Zebra Conductor in Drums from the Vehicle and Shifting of same to Safe Storage Place at 132/33KV Sub Station, Shahabad (1 Job per Drum)
Laying of 3.5x400 sq.mm LT Power Cable, 50cm below the ground level after Excavation of trench, Laying the 1st class brick lining, filling of river sand along & over the cable, then back filling & levelling the trench after Laying of Cable. The work also includes Termination of cable on both sides with Crimping of Lugs.
Providing & Fixing of Cable Marker duly made of Cast Iron.
Fabrication of 3 Meter Long Electrode with 40 mm dia. M.S. Rod having 150 mm Long Conical Shape and then its Piercing Vertically inside the Ground with top 700 mm below Ground Level and its welding with earthmat.
Extension of MS Round Bar Earthmat 40mm by digging of earth cutting, laying, welding and back filling of earth and doing all other associated work to complete the job satisfactorily.
Special earthing by way of boring & lowering of GI Pipe 50 mm dia 60 feet long from ground upto water level and it will be connected to the MS strip 50x6mm including providing, laying of MS strip with cutting welding bending etc. for 36 KV VCB’s & 36 KV CT’s etc. of different bays at 132 KV Sub-station, Shahabad. The earth strip will be welded to the GI Pipe. The work also includes cap & clamps for pouring water. All the materials, labour and T&P shall be supplied by the firm.
Providing & fixing of updated single line diagram in PVC sheet of size 6x6 feet of complete 132/33 KV switchyard of 132 KV S/S, Shahabad as per instruction by concerned JE/SDO.
Bharat Trading Corporation (BID ID -4856489)
EMC Associates (BID ID -4856043)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .