Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC BATHAIPAR RAWATPAR DEORIA DEORIA UTTAR PRADESH 274001 UDYAM UP 21 0039531 | DEORIA | UTTAR PRADESH | 274001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.5 L+₹41,800 (1.30%)Rejected-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹32.7 L+₹70,235 (2.19%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹34.0 L+₹2.0 L (6.11%)Rejected-Finance JAJJAR KOTLI JAMMU J K 151222 | JAMMU | JAMMU | J K | 151222 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹34.7 L+₹2.7 L (8.30%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹80,120
Closing Date
19 Mar 2021, 6:00 pmClosed
GE UTILITIES
GE UTILITIES UDHAMPUR PO GARHI PIN 182121
Outsourcing of services for operation and maintenance of Water supply installation of Nuddle Khud, Duddar Nallah, AEE, FAD PH and Depta and complaint cell in Booster area and associated maintenance works in distribution area under GE U Udhampur
2021_MES_425902_1
GE/U-83/2020-21
Open Tender
Miscellaneous Works
Item Rate
330 days
GE Utilities Udhampur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹80,120
Yes
23 Apr 2021
26 Feb 2021
22 Mar 2021
26 Feb 2021
19 Mar 2021
12 Mar 2021
Amount
Outsourcing of services for operation and maintenance of pumps, motors, DG sets and water supply distribution network, under AOR of 15FAD PH, in two shifts in a day (each shift of eight hours) by deploying 01 (One) FGM (Skilled) and 01 (One) Mate (Un-Skilled) each shift of 8 hours, total 02 FGM and 02 Mate in two shifts in a day. Note: total 02 (two) FGM & 02 (two) Mate for a day in two shifts to be deployed.
Outsourcing of services for operation and maintenance of water supply distribution system and maint of pipelines at FOD complex, FOD Depot, Kalimata Enclave and Chibber Enclave by deployed one valve man in each shift of 8 hours. total two valveman (Un-Skilled) in two shifts per day. Note: total 02(two) valve man per day for carrying out their duties.
Outsourcing of services for operation and maintenance of water supply distribution pipelines scattered at AEE, Para Regt, Arty Regt, Golf view complex and key person qtr by deployed one valve man (Un-Skilled) in each shift of 8 hours. total two valveman (Un-skilled) in two shifts per day. Note: Total 02(two) valve man per day for carrying out their duties.
Outsourcing of services for operation and maintenance of Raw water supply installation at Nuddle Khud pump house, in one shift per day ( shift of 8 hrs) by deploying 01 (One) Mate (Un-Skilled). Note: The contractor has to employ 01 (One) Mate per shift of 08 hours for carrying out their duties.
Outsourcing of services for operation and maintenance of water pipelines distribtion network at Depta PH, Sansar Chand Vihar , by deploying 01(one) FGM (Skilled) in each shift of 8 hours, total 02 FGM in two shifts in a day. Note: Total 02(two) FGM per day to be employed.
Outsourcing of services for operation and maintenance of raw water supply installation at Dudhar Nalah PH, in one shift per day ( shift of 8 hrs) by deploying 01 (One) FGM (Skilled) in each shift. Note: The contractor has to employ 01 (One) FGM per shift of 08 (eight) hours.
Outsourcing of services for operation and maintenance of water supply distribution line supplying water to OTM Accn, Md Accn & unit area located under AOR of Jib area by deploying 02 (two) Pipe fitters (Skilled) in one shift. Note: Contractor shall deployed 02 (two) Pipe fitters in one shift of 08 hours.
Note for item 1 to 7: (i) The contractor will ensure suitable repalcement of Electrician/FGM/Pipe fitter /Mate on rest days and Wages for the same deemed to be included in the unit rates quoted against items of M&O. (ii) The contractor shall produce details of the persons deplyed by him his skilled/unskilled persons like Name, Aadhar No, Aadhar linked Bank A/c No, Experience certificate EPF No and ESIC No within a week of Acceptance of tender. The work will be commenced only after submission of requisite documents . (iii) The contractor shall ensure that his persons always be present in their shift. (vi) The contractor shall be responsible for maintaining the complete area (i.e. inside boundary wall ) such as building, hard standing, foothpath etc in neat and clean position . All necessary T&P for cutting /cleaning of grass and vegitation will be arranged by contractor without any extra cost. (iv) The contractor shall provide uniform, raincoat, protective clothing such as hand gloves, helmet, safety belt, first aid box and shoes etc to all persons on duty and the cost of the same is deemed to be included in quoted rate of items of M&O here in before. The uniform shall have the name of the contractor and MES written on the shirt Pocket (Left and right side).
Note for item 1 to 7: (v) The persons deployed by the contractor should have experience of nature of work under this CA. (vi) The contractor shall provide log sheet and maintain the the same on daily basis and the cost of the same is deemed to be included in quoted rate of BOQ here in before. (vii) THE CONTRACTOR SHALL MAKE PAYMENT TO HIS STAFF EMPLOYED FOR THIS WORK EVERY MONTH, ACCOUNTED FOR, FROM THE DATE OF COMMENCEMENT OF THE WORK AND SUBMIT TO THE ENGINEER-IN-CHARGE BANK STATEMENT/INDIVIDUAL’S PASS BOOK, EPF AND ESIC DETAILS AS A PROOF OF PAYMENT.
Taking down old unserviciable panel / soft starter panel of any size, any capacity and any make including all its components, and removing electrical connections to motors installed at water supply installations. Complete all as specified and by Engr-in-Charge.
Supply, Installation , testing and commissioning of indoor type, weather proof, LT Panel of 2.10 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 50x50x6 mm equal angle, embedded in PCC 1:2:4 type B-1 blocks of size 15 x15x15 cm front and back openable, double door openable up to minimum 150 degree & removable type having magnetic catche system, lockable/openable by keys from both sides having chromium plated locks, levers and air vent gaskets for natural air flow suitable foamed in PU gasket to make it dust/vermin proof, IP 54 protection, powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI for short circuit current of 35/36 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produced to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete suitable cable glands for cable entry.The panel shall accommodate the following equipments:-
Supply, Installation , testing and commissioning of indoor type, weather proof, LT Panel of 2.10 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 50x50x6 mm equal angle, embedded in PCC 1:2:4 type B-1 blocks of size 15 x15x15 cm front and back openable, double door openable up to minimum 150 degree & removable type having magnetic catche system, lockable/openable by keys from both sides having chromium plated locks, levers and air vent gaskets for natural air flow suitable foamed in PU gasket to make it dust/vermin proof, IP 54 protection, powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI for short circuit current of 35/36 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produced to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete suitable cable glands for cable entry.The panel shall accommodate the following equipments:-
Supply, Installation , testing and commissioning indoor type, weather proof, LT Panel of 2.10 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 50x50x6 mm equal angle, embedded in PCC 1:2:4 type B-1 blocks of size 15 x15x15 cm front and back openable, double door openable up to minimum 150 degree & removable type having magnetic catche system, lockable/openable by keys from both sides having chromium plated locks, levers and air vent gaskets for natural air flow suitable foamed in PU gasket to make it dust/vermin proof, IP 54 protection, powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI for short circuit current of 35/36 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produced to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete suitable cable glands for cable entry. The panel shall accommodate the following equipments: -
(a) Soft starter Altistart 22 soft start/soft stop units support the controlled starting and stopping, via voltage and torque, designed to meet the performance requirements of applications where ruggedness, security of personnel and equipments and ease of setup are a priority. The bypass function (based on a bypass contactor) should be integrated into the starter. This approach should suit applications where it may be necessary to bypass the starter at the end of starting to limit the starters heat dissipation, and integrated display terminal that allows the user to change both the programming and the adjustment or monitoring parameters in order to adapt and customize the application in line with site requirement needs. And they also feature and integrated thermal motor protection function as well as machine monitoring functionally, offer immediate installation setup capability. Fixing the same in soft starter panel of three phase squirrel case induction motors for rating 75 to 100 HP. Make- Schneider Cat Part No- ATS22D88Q - 01 No or equivalent of L& T and ABB.
(f) Panel indicating lamp neon/LED type (Red, Yellow & Blue) with lamp holders - 03 Nos (g) Panel instrumental wiring with FRLS suitable size but not less than 2.5 Sqmm copper wire single core - 01 Job (h) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 600 Amps for phases and neutral - 01 set
Supply and fixing of fully automatic star delta motor starter in sheet steel enclosure type MN 65 with single phase protection feature motor rating AC 3 phase 415 volts, 50 Hz for motor of capacity 50 HP as per Havells cat part No IHHASDYC* or equivalent of L&T and Indo Asian including taking down the old existing starter, complete all as directed by Engr-in-Charge.
Material and labour of earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of the plate not less 1.5 mtr below normal ground level connected to galvanized earth plate with 32 X 6 mm thick GI strip by means of suitable size of nuts, bolts, check nuts and washers all as specified in electrical plate SSR Part I including necessary .Exc & earth work, providing charcoal and salt dust layers and construction of PCC pit in 1:3:6 using 20 mm size graded stone aggregate, precast RCC 40 mm thick cover in 1:2:4 type B 1 with 12 mm dia steel MS plain bar, lifting handle 2 Nos GI pipe of550 x 550 x 50 mm bore for earth lead protection and GI pipe 15 mm dia for watering, with funnel and wire mesh including testing on completion. Note: No payment shall be made if earth resistance test value not found satisfactory and contractor has to make alternate earthing till the result not found satisfactory without any extra cost. Rate shall be deemed to include this provision. The testing equipments to measure the earth resistance will be the arrangement of contractor.
slathia construction works
PREM NATH KHAJURIA AND SONS
BARU ENTERPRISES
MOHAN LAL AND SONS
M/S H.R CONSTRUCTION CO
S S BUILDERS
proach associates
M/S VEDHANT ASSOCIATES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .