Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC PULGAON | L1 | Accepted-AOC Being a lowest bidder and reasonable rate quoted | |
| 2 | L2₹13.9 L+₹45,598 (3.40%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tender | |
| 3 | L3₹14.0 L+₹56,882 (4.24%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tender | |
| 4 | L4₹14.2 L+₹75,646 (5.64%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tender | |
| 5 | L5₹14.3 L+₹93,990 (7.01%)Rejected-Finance BHAWANI KRUPA GANDHI CHOWK PULGAON | PULGAON | WARDHA | MAHARASHTRA | L5 | Rejected-Finance Other than lowest tender |
Tender Value
Refer Docs
EMD Value
₹27,800
Closing Date
12 May 2021, 6:00 pmClosed
GE PULGAON
Garrison Engineer, Pulgaon CAD Pulgaon
PROVISION OF SINGLE PHASE THREE PHASE INTEGRAL UNIT FOR AUTOMATIC SWICHING OF STREET LIGHTS SPECIAL REPAIR TO WIRING OF OFFRS MESS BLDG NO T10 IN RA AT CAD PULGAON
2021_MES_438157_1
8875/PUL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE PULGAON
Asper tender documents
7 documents required · 7 mandatory
₹500
GE PULGAON
₹27,800
Yes
1 Jun 2021
23 Apr 2021
18 May 2021
23 Apr 2021
12 May 2021
7 May 2021
23 Apr 2021 - 3 May 2021
Amount
Supply & fixing of Automatic Street light Control Switch using Infrared Sensor based Nature Switch for automatic switching of street lights. Nature Switch operation should be based on Natural light Lux level.Required illumunance Level for Switching ON is<30 Lux and for Switching OFF >10 lUX.The sensor should also have part night operation facility of min .4 hrs to max.12 hrs .The sensor along with suitable power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Rust proof,Electric shock proof,Termite proof and FR grade thermoplastic polycarbonate Enclosure with hinged Enclosure conforming to IP-66 protection class 2. The Circuit should also have provision for Manual Operation(i.e sensor By -pass option).Two-phase load of 2x8 kw (Swadeep-66-16 kw 3P) with Contactor,Incoming MCB & Outgoing MCB rating of 40-63 Amps & Main load Circuit Wiring(Copper) of min.16 sq .mm with two nos Contactors,two nos.Incoming MCBs & 2 nos.Outgoing MCBs of 40-63 Amps each & Circuit wiring (Copper) of min.10 sq.mm. Make: Nature Switch(swadeep-66-16kw 3P)/ Legrand
Supply & fixing of Automatic Street light Control Switch using Infrared Sensor based Nature Switch for automatic switching of street lights. Nature Switch operation should be based on Natural light Lux level.Required illumunance Level for Switching ON is<30 Lux and for Switching OFF >10 lUX.The sensor should also have part night operation facility of min .4 hrs to max.12 hrs .The sensor along with suitable power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Rust proof,Electric shock proof,Termite proof and FR grade thermoplastic polycarbonate Enclosure conforming to IP66 protection class 2. The Circuit should also have provision for Manual Operation(i.e sensor By -pass option) Single-phase load of 8 kw(Swadeep-66-8kw 1P) with Contactor,Incoming MCB & Outgoing MCB rating of 40-63 Amps & Main load Circuit Wiring(Copper) of min.16 sq .mm Make: Nature Switch(swadeep-66-8kw 1P)/ Legrand
Supply & fixing of angle iron frame of 40x40x6 mm size fixed in PCC floor including drilling and welding, nut bolts, washer, lugs suitable for cables, or fixed with pole including necessary clamps for fixing with angle all as complete directed by Engr-in -Charge. Note:- Anything left for installation/fixing the same may please be added in quoted rate nothing extra will be paid.
Taking down carefully conceled/ casing caping point wiring copper / aluminium (light / fan / scoket) complete (with fittings such as switches ceiling rose, pendents, regulators sockets etc) and making good disturbed surface with exisitng specification all as specified and directed by Engr-in-Charge.
M&L for point wiring complete with 1.5sqmm single core sheathed PVC insulated FRLS cable 1100 V grade multistranded copper conductor of code red, blue and yellow for phase, black for neutral and green for earth of ISI marked drawn through and incl PVC casing caping of suitable size with accessories ISI marked incl PVC insulated copper cable for earth of same type and sized connected to earth dolly including provision of PVC box of suitable size for mounting switches / sockets and fan regulators etc complete all as specified and directed for the following:-
One light point controlled by one switch one way
One ceiling fan / exhaust fan / wall mounting fan point controlled by one switch one way
One socket outlet three pin 5/6 Amps controlled by one switch on the same board.
One switch socket outlet three pin 5 /6 Amps controlled by one switch on independent board.
Material and labour for point wiring complete with 1.5 sqmm single core sheathed PVC insulated FRLS cable 1100 V grade multistranded copper conductor of code red, blue and yellow for phase, black for neutral and green for earth of ISI marked drawn through and including non metallic rigid PVC Conduit of 20mm dia with accessories ISI marked concealed in wall/ceiling including PVC insulated copper cable for earth continuity conductor of same type and size and connected to earth dolly including provision of sunken cast iron/pressed steel terminal boxes of suitable size with 3mm thick plastic laminated sheet cover for mounting switches/sockets and regulators or in modular boxes complete all as specified and as directed. One light point controlled by one switch one way. Note:- Cutting chases for laying conduit and sunken boxes and making good to walls, floor will be included in the above quoted rates.
One light point controlled by one switch one way
One socket outlet three pin 5/6 Amps controlled by one switch on the same board.
M&L for point wiring with stranded copper conductor 2.5 Sqmm (nominal area), single core, multistranded, FRLS , PVC insulated and sheathed cabel 1100 volts grade, ISI marked drawn in and incl PVC casing caping of suitable size with accessories ISI marked incl PVC insulated copper cable for earth of same type and sized connected to earth dolly including provision of PVC box of suitable size for mounting complete all as specified and directed.
M&L for switch piano flush type single pole,one way, 5 Amps, 240 V complete all as specified and directed. Make : Anchor/Havells/Cona
S&F socket outlet 5/6 pin type,5 Amps, 240 V complete all as specified and directed. Make : Anchor/Havells/cona
S&F switch socket combination 2 in 1 pin flush type (multipurpose type) 5 Amps, 240V complete all as specified and directed. Make : Anchor/Havells/cona
S&F switch socket combination flush type (multipurpose type) but 5A/16A, 5 in 1 15 Amps, 240V complete all as specified and directed. Make : Anchor/Havells/cona
S&F ceiling rose surface backelite type with 3 terminals complete including .Make : Havells/Anchor/Cona
S&F fan regulator electronic step type AC 240 Volts,50 Hz complete . Make : Anchor/Cona/Havells
S&F lamp holder,PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. Make: PLAZA/SSK/Cona
S&F in replacement LED tube light lamp 1 x 18/20 watt retrofit including suitable size of batten complete (01 set) (single / double side connection) incluing taking down existing fitting complete all as specified and directed. Make:- Crompton/Havells /Philips.
Taking down carefully sub main wiring including batten/ conduit by unscrewing from wall, ceiling and making good surfaces to match with original status as specified and directed.
M&L for sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated multistranded copper conductor, single core cable in PVC conduit of suitable size with accessories ISI marked concealed in wall/ceiling complete all as sfecified and directed.
2 run of 4sqmm PVC FR copper cable and 1run of 4 sqmm PVC FRLS copper cable for earth wire Note :- 1. 2 runs of wire and 1 run of earth wire will be measured as one unit i.e RM 2. Groove Cutting ,pinning and plastering of disturbed surface etc shall deemed to be included in the quoted unit rate
4 run of 6sqmm PVC FR copper cable and 2run of 6 sqmmPVC FRLS copper cable for earth wire Note :- 1. 4 runs of wire and 2 run of earth wire will be measured as one unit i.e RM 2. Groove Cutting ,pinning and plastering of disturbed surface etc shall deemed to be included in the quoted unit rate.
M&L sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated multi stranded copper conductor, single core cable in PVC casing caping of suitable size with accessories ISI marked on wall/ceiling complete all as sfecified and directed
2 run of 4sqmm PVC FR copper cable and 1run of 4 sqmm PVC FRLS copper cable for earth wire Note :- 1. 2 runs of wire and 1 run of earth wire will be measured as one unit i.e RM 2. Any Cutting ,pinning and plastering of disturbed surface etc shall deemed to be included in the quoted unit rate.
2 run of 6sqmm PVC FR copper cable and 1run of 6 sqmm PVC FRLS copper cable for earth wire Note :- 1. 2 runs of wire and 2 run of earth wire will be measured as one unit i.e RM 2. Any Cutting ,pinning and plastering of disturbed surface etc shall deemed to be included in the quoted unit rate.
S&F in replacement of sheet steel enclosure with Double door TPN 12 ways 440 volt factory fitted rated bus bars,earth bar,neutral links complete incl. blanking plates as required & making good the disturbed surfaces complete including taking down old one all as specified and directed. Make : Havells/legrand/Schneider
S&F in replacement of sheet steel enclosure with Double door TPN 6 ways 440 volt factory fitted rated bus bars,earth bar,neutral links complete incl. blanking plates as required & making good the disturbed surfaces complete including taking down old one all as specified and directed. Make : Havells/legrand/Schneider
S&F in replacement of sheet steel enclosure with double door flush mounting ,MCB, DB, SPN, 8 ways,240 volt factory fitted rated bus bars,earth bar,neutral links complete incl. blanking plates as required & making good the disturbed surfaces complete including taking down old one all as specified and directed. Make : Havells/legrand/Schneider
S&F in replacement sheet metal enclosure Single pole and neutral 240 V with a two pin and earth plug and socket complete with one single pole MCB of 20 / 32Amp complete including taking down old one all as specified and directed all as specified and directed Make : Havells/legrand/Schneider
S&F in replacement of MCB TPN 63 Amps 240V ,50 Hz ,breaking capacity 10 KA," C " series complete including taking down old one all as specified and directed. Make:Havells/Legrand/Schneider
S&F in replacement of MCB SPN 32 Amps 240V ,50 Hz ,breaking capacity 10 KA," C " series complete including taking down old one all as specified and directed. Make:Havells/Legrand/Schneider
S&F in replacement of MCB SP 06-32 Amps 240V ,50 Hz, breaking capacity 10 KA," C " series complete including taking down old one all as specified and directed. Make:Havells/Legrand/Schneider
Supply and Fix in replacement to wall / pole of any height LED bldg security light 25 watt including GI pipe sutaible dia bracket not less than 1 mtr bend to shape with 2 clamps, nuts, bolts, washers and PVC 3 core ISI mark flexible wire from ceiling rose to fitting complete including takingdown old one all as specified and directed.
S&F in replacement Energy efficient LED bulb,B22 10 Watt complete all as specified and directed (for holder) Make-Havells /Jaquar/Philips / Bajaj
Supply, laying and testing in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70.0 sq mm 3.5 core including taking down old one.
Supply, laying and testing in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core including taking down old one.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50 metre depth for foundation, laying of cables/pipes/poles etc., and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soils complete all as specified and directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed.
Supply and lay, dry river sand filling in trenches to required width at bottom and top of cable as cable cushioning including spreading, leveling, watering and consolidation complete all as specified and directed.
Supply and lay un-reinforcement precast concrete cable cover, class LV, type 1, flat of size 250 X 150 X 40mm for LT cable and laid dry in trenches over underground cables complete all as specified and directed
Supply and lay pipe galvanized, “light grade” 40 mm dia (Cable Protection Pipe) complete all as specified and directed
Supply and fix in replacement of indoor LED down lighter square aesthetically designed, recess mounted, decorative recess mounted 8 W LED (square) 6500K spot light for ceiling cut out 110mm complete all as specified and as directed. Make: Havells as per Cat No: LHEEBQP7IL1W008 or equivalent make as CG/Bajaj.
Supply and fix in replacement of indoor LED down lighter round aesthetically designed, recess mounted, decorative recess mounted 8 W LED (Round) 6500K spot light for ceiling cut out 110mm ncluding taking down old unserviceable complete all as specified and as directed. Make: Havells as per Cat No: LHEEBQP7IL1W008 or equivalent make as CG/Bajaj.
Supply and fix in replacement of LED recessed mounted 2' X 2' 36 Watt light along with fixture including taking down old unserviceable complete all as specified and as directed. Make: Cat No LCTLRN-36-CDL of Crompton or equivalent to Bajaj/Havells
Supply and fix in replacement LED recessed mounted 1' X 1' 18 Watt light along with fixture including taking down old unserviceable complete all as specified and as direceted. Make: Cat No LCTLRN-18-CDL of Crompton/Bajaj/Havells
Supply and fix in replacement LED garden Light 10 watt IP 66 made out of pressure die cast powder coated housing with PC diffuser including suitable dia base pipe not less than 1 feet inserted into ground / wall / gate piller for extra protection, 12mm dia steel bar caging for protection of light opening on top fixed on ground with suitable size of nuts, bolts, washers, PCC etc, electric supply connection and testing ncluding taking down old unserviceable light complete all as specified and directed. Make:- Cat No LBLA1-10-CDL of Crompton and eqvt in Philips or Havells.
Material and Labour for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below ground level connected to galvanized iron earth lead wire 4.00mm dia by means of bolts, nuts, check nuts, washers of galvanized iron and connected to main switch/control board upto 7.5m away from the earth electrode including excavation earth work, PCC chamber, RCC cover slab char coal, watering pipe, wire mesh lugs, earth lead protection pipe 15mm bore, medium grade 7.5m long as applicable and as per plate No. 3 of SSR Part-I 2009 and all as specified. (a) Excavation and earth work in any type of soil. (b) Drilling of holes in electrode (c) PCC pit in cement concrete (1:2:4) type B-1 (d) 40 mm thick Pre-cast RCC cover or reinforcement with 8mm TMT bars at 100mm c/c bothways with suitable handle. (e) Funnel with watering pipe of GI 20 mm nominal bore ,medium grade & copper lug etc. (f) 15mm nominal bore medium grade GI protection pipe upto 7.50 m long for protection of earthing lead. (g) Requisite quantity of charcoal and common salt. (h) Connection to earthing test point and testing on completion.
Supply & fix in replacement exhaust fans AC single phase, heavy duty, 1400 RPM, 230/ 240 V of size 380 mm sweep complete all specified and as directed. Make:Model No EXHD380-4-1 of Crompton and eqvt in Philips or Havells.
SHRI RANI SATI TRADERS
SHUBHAM SALES AND ENGG WORKS
M/s MM TRADERS
M/S JAI BHAWANI CONSTRUCTIONS
SHREE SIDDHIVINAYAK TRADERS
Bidder Name
SHRI RANI SATI TRADERS
SHREE SIDDHIVINAYAK TRADERS
SHUBHAM SALES AND ENGG WORKS
M/S Maa Durga Constructions,Pulgaon
M/s MM TRADERS
M/S JAI BHAWANI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .