Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC 0 NERTHUA RAEBARELI UTTAR PRADESH 229103 | RAE BARELI | UTTAR PRADESH | 229103 | ₹1.2 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹1.2 Cr+₹4.5 L (3.80%)Rejected-Finance | ₹1.2 Cr+₹4.5 L (3.80%) | L2 | Rejected-Finance Rate higher than L1 |
| 3 | L3₹1.3 Cr+₹6.5 L (5.46%)Rejected-Finance S NO 41 4K JAIHIND SOCIETY GANESH NAGAR NEAR ANAND PARK VADGAON SHERI PUNE 411 014 | PUNE | PUNE | MAHARASHTRA | 411014 | ₹1.3 Cr+₹6.5 L (5.46%) | L3 | Rejected-Finance Rate higher than L1 |
| 4 | L4₹1.3 Cr+₹6.5 L (5.52%)Rejected-Finance | ₹1.3 Cr+₹6.5 L (5.52%) | L4 | Rejected-Finance Rate higher than L1 |
| 5 | L5₹1.3 Cr+₹10.0 L (8.41%)Rejected-Finance | ₹1.3 Cr+₹10.0 L (8.41%) | L5 | Rejected-Finance Rate higher than L1 |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
21 Aug 2021, 6:00 pmClosed
COL N K SAH
CWE AF LOHEGAON
ADDN ALTN OF BLDG NO P 52 and P 109 AND UPGRADATION OF BLDG NO P 22 AT AF STN PUNE
2021_MES_458497_1
81827/E8
Open Tender
Miscellaneous Works
Works
365 days
GE AF LOHEGAON
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE AF LOHEGAON
₹2.1 L
Yes
27 Sept 2021
9 Jul 2021
23 Aug 2021
9 Jul 2021
21 Aug 2021
9 Aug 2021
Amount
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and as directed by Engr-in- Charge.
M&L for Non - skid Ceramic Coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15 mm screed bed or bedding layer for floor finishes in CM 1:4 complete all as specified and as directed by Engr-in-Charge.
M&L for 20mm thick Granite (of any colour) stone in cooking platforms set and jointed in neat cement slurry including pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite stone including grinding and polishing complete laid over 20 mm thick screed bed or bedding layer in CM 1:4 complete all as specified and directed by Engr-in- Charge.
M&L for Double Chaged Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15 mm screed bed or bedding layer for floor finishes in CM 1:4 complete all as specified and directed by Engr-in- Charge.
M&L for 25 MM thick cement concrete type B-1, 1:2:4 ( 20 mm graded aggregate) as in sub base to flooring/path etc, complete all as specified and as directed by Engr-in- Charge.
Taking down cement or cement lime plaster on brick or stone walls, etc including racking out joints hatching for key, scrubbing down with water etc complete all as specified and as directed by Engr-in- Charge.
M&L for joint free Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match in colour cement to match complete all as specified and as directed by Engr-in- Charge.
M&L for Double Charged Vitrified tiles 10 mm thick (square/ rectangular) polished, area of any size in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in- Charge.
M&L for 20 mm thick Granite (of any colour) stone machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed by Engr-in- Charge.
M&L for 10mm thick rendering in CM 1:6 on fair faces of brick or concrete surface complete all as specified and directed by Engr-in- Charge.
M&L for 10mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces, drain walls & finishing the surface even and smooth without using extra cement complete all as specified and directed by Engr-in- Charge.
M&L for rendering in two layers on external surfaces first layer 10mm thick in CM 1:6 on fair faces of brick/PCC block or concrete surfaces and second layer ( setting coat / finishing) 5mm thick in CM 1:4 with approved water proofing compound finished even and smooth without using extra cement complete all as specified and directed by Engr-in- Charge. (Note:- WPC shall be measured and paid seperately)
Supply only Liquid water proofing compound complete all as specified and as directed by Engr-in- Charge.
M&L for 10 mm thick rendering in CM 1:4 on broken chajjas / facia / walls /ceilings etc, area n. exc 3 sqm each patch (in repairs) , includings finishing to match with existing surfaces without using extra cement complete all as specified and directed by Engr-in- Charge.
M & L for 10mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces and provn of sagol finish complete all as specified and as directed by Engr-in- Charge.
M&L for 15 mm thick rendering in cement morta 1:6 on fair faces of brick or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engr-in- Charge.
M&L for applying two coats of white wash including preparation of newly plastered surfaces of wall/ chajjas /facia/ceilings complete all as specified and directed by Engr-in- Charge. Note :- Application of White wash shall be got done through authorised applicator)
M&L for applying two coats of Cement Base Paint over a coat of chalk whiting on walls including preparation of new or previously untreated surfaces complete all as specified and directed by Engr-in- Charge. Note:- Application of cement base paint shall be got done through authorised applicator)
M&L for applying two coats of oil bound distemper over a coat of primer,over 1mm thick wall care putty on walls including preparation of new or previously untreated surfaces complete all specified and directed by Engr-in- Charge. Note :- Application of oil bound distemper shall be got done through authorised applicator)
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundations, etc, or for shafts, wells, manholes etc and getting out in soft /loose soil complete all as specified and as directed by Engr-in- Charge.
ditto all as per item No. 20 above but hard /dense soil complete all as specified and as directed by Engr-in- Charge.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm with soil obtained from excavation complete all as specified and as directed by Engr-in- Charge.
Removing excavated excavated soil/ material exceeding 50mtr but not.exc 250 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engr-in- Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred / stopped ends etc complete all as specified and directed by Engr-in- Charge.
S&F for Mild steel Plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410W(Gde-E-250) complete all as specified and as directed by Engr-in- Charge.
S&F Mild steel Framed work such as grills, gratings etc with ends of bars shouldered and /or riveted, or forget into spikes framed guard bars barred iron doors ladders framed balusters walk ways railings cable trench cover & water tanks and similar work conforming to Fe 290-Gde-E-165 complete all as specified and as directed by Engr-in- Charge.
Demolition of brick work / stone built in cement mortar complete all as specified and directed by Engr-in- Charge.
M&L for precast cement concrete block masonry with solid blocks, exc. 10cm in width with PCC type C1, 1:3:6 (using 20 mm graded stone aggregate) and set in CM (1:6) complete all as specified and as directed by Engr-in- Charge.
M&L for brick work with sub-class 'B' bricks, straight or curved on plain to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed by Engr-in- Charge.
M&L for applying two coats of white wash including preparation of newly plastered ceiling surfaces complete all as specified and directed by Engr-in- Charge. Note :- Application of white wash shall be got done through authorised applicator)
M&L for applying two coats of weather coat exterior emulsion paint over a coat of alkali resistant primer including preparation of old surface of walls and complete removal of existing treatment complete all as specified and directed by Engr-in-charge. Note :- Application of weather coat exterior emulsion paint shall be got done through authorised applicator)
M&L for applying two coats of plastic emulsion interior paint over a coat of primer over 1mm thick wall care putty on plastered surface of wall including preparation of surfaces complete removal of existing treatment complete all as specified and as directed by engineer in charge complete all as specified and as directed by Engr-in- Charge. Note :- Application of plastic emulsion interior paint shall be got done through authorised applicator)
M&L for applying two coats of plastic emulsion interior paint over a coat of primer over 1mm thick wall care putty including preparation of newly plastered surfaces complete all as specified and as directed by Engr-in- Charge. Note :- Application of plastic emulsion interior paint shall be got done through authorised applicator)
M&L for water proofing treatment with APP based polymeric membrane over 15mm thick plaster on roof with the following courses of treatment :- (a) Complete removal of existing treatment, cleaning & washing the concrete /tiles surface by using wire brush including junction of parapet etc. (b) M&L 15mm thick cement plaster in CM 1:4 using water proofing liquid as per manufacturer instructions over neat cement slurry @ 3kg/Sqm on roof surface. Note: Water proofing liquid /compound will be measured & paid separately. (c) Applying bituminous primer (IS 3384) @ 0.160 Kg per sqm of the surface area including cleaning the surfaces complete all as specified. (d) M&L for APP based polymeric membrane minimum weighing 3 kg/Sqm and minimum 3mm thick reinforcement with polyster non woven fabric (wt reinforcement not less than 150gms/sqm) laid in primed surfaced application including preparation and applying two coats of Heat resisting Aluminium paint over APP membrane complete all as specified and directed.
Taking down Shutters of any description exc 1 sq. m and not exc 2 sq. m each complete all as specified and as directed by Engr-in- Charge.
S & F 30 mm thick flush shutter water proof BWR grade solid core construction with block board core and ply wood face panel commercial type both sides complete all as specified and as directed by Engr -in - Charge.
S&F for 35mm thick IInd class hard wood glazed and skelton shutters divided into squares with plain chamfered or reounded miltred and related sash bars number to received glass gauze etc edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I section 8 clause 8.20(a) supplied and fitted to chowkats complete complete all as specified and as directed by Engr-in-charge.
S&F for 30mm thick IInd class hard wood glazed and skelton shutters divided into squares with plain chamfered or reounded miltred and related sash bars number to received glass gauze etc edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I section 8 clause 8.20(a) supplied and fitted to chowkats complete complete all as specified and directed by Engr-in-charge.
Taking down shutters of size exc 1 sqm and n exc 2 sqm each and refixing in the same opening including necessary adjustment after laying of floor tiles complete all as specified and directed by Engr-in-charge.
Taking down chowkats with shutters of any description not exc 1.50 sqm each and removing to or from store complete all as specified and directed by Engr-in-charge.
S & F in repairs 3mm thick sheet glass glazing with oil putty or wooden beads in squares n. exc 0.5 sqm in each pane complete all as specified and directed by Engineer in charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden /metal frames or stone, concrete glazed with putty or fixed with beads including punching or drilling out old glazing pins/spring clips complete all as specified and directed by Engineer in charge.
S&F in repairs 3mm thick Figured glass, pin head type and glazing with oil putty /or wooden beads in squares n exc 0.50 sq. m in each pane complete all as specified and directed by Engineer in charge.
S&F 5.5mm thick sheet glass glazing with oil putty or wooden/ rubber beads in squares n. exc 0.50 sqm in each pane complete all as specified and directed by Engineer in charge.
Taking down Chowkhats or frames without taking of shutters exc 1.5 sq. m but not exc 4 sq. m each complete all as specified and as directed by Engr-in- Charge.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing complete all as specified and directed by Engr-in- Charge.
S&F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of ms tubes for top &bottem rails, ms frame shall be covered with heat moulded plain colour PVC 'C' channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour pvc sheetfor top rail ,lock rail, &bottem rail, on either side & as gap insert for top rail , panneling of plain colour pvc sheet to be fitted in the ms frame welded /sealed to the stiles & rails with suitable pvc sheet beading, & jointed together with solvent cement suppling & fixing in the frame at site as per spacification &drawing complete all as specified and directed by Engr-in-Charge.
S&F mild steel 100 mm long butt hinges, medium weight cold rolled complete all as specified and directed by Engineer in charge.
S&F 150 mm long aluminum anodised barrel tower bolts of extruded section of size complete all as specified and directed by Engineer in charge.
S&F 200 mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed by Engineer in charge.
S&F 125 mm extruded aluminum alloy handles, cast type, anodized complete all as specified and directed by Engineer in charge.
S&F in repairs 300 mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed by Engineer in charge.
S&F in repairs for Galvanised mild steel wire cloth of 0.56 mm nominal dia of wire & and average width of aperture 1.18 mm fixed with Aluminium beeds for bird proofing of ventillators complete all as specified and directed by Engineer in charge.
M&L MS Framed work of Fe-410- W (GdeE-250) in repairs as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing including 4 lever mild steel safety lock, lockable from inside and outside complete all as specified and directed by Engineer in charge.
Dismantling of wall and ceiling board ( fibre, pulp, insulation etc) as in ceiling and lining of any gauge or any thickness including cover fillets complete all as specified and directed by Engineer in charge.
S&F for aluminium powder coated snap grid frame work for suspended false ceiling size 605 x 605mm with 9mm thick PU coated Gypsum board in ceiling fixed with screws including hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete as per manufacturer instructions complete all as specified and directed by Engineer in charge.
S&F Collapsible steel gates, top hung, consisting for channel pickets, pivoted flat bars, top and bottom runners, handles etc. as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed by Engineer in charge.
Demolition of Stone slabs and tiles laid, bedded, pointed in ay mortar of any description or thickness in floors, aprons etc. complete all as specified and directed by Engineer in charge.
M&L for Machine cut cudappah stone slab 20-25mm thick over 20mm thick cement screed in CM 1:4, base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer in charge.
M&L for providing 75 mm thick PCC (1:3:6) type C2 using 40 mm graded aggregate as Path/Plinth protection finished the surface even & smooth with out using extra cement complete all as specified and directed by Engineer in charge.
Disconnecting existing tank setting aside (or lowering if required) for repairs clening etc. and hoisting if required reconnecting and re-fixing in same position (cleaning repairng etc. mesured seprately) Exc 500 & not exc 1000 ltr water tank complete all as specified and directed by Engineer in charge.
Cleaning and removing all scale and dirt etc from tank and from mouths of circulating pipes etc exc 500 & not exc 1000 ltr water tank complete all as specified and directed by Engineer in charge.
Dismantling water tank and removing Exc 500 & n Exc 1000 ltr water tank complete all as specified and directed by Engineer in charge.
S&F rotational moulded polyethylene water storage tank tripple layer cylindrical vertical with closed top 500 ltrs capacity hoisted and fixed in position connecting to inlet and outlet pipe connections with and including 20mm dia GI wash out with plug fixed in repairs complete all as specified and directed by Engineer in charge.
S&F rotational moulded polyethylene water storage tank tripple layer cylindrical vertical with closed top 1000 ltrs capacity hoisted and fixed in position connecting to inlet and outlet pipe connections with and including 20mm dia GI wash out with plug fixed in repairs complete all as specified and directed by Engineer in charge.
M&L for repair to 15 mm elbows brass both ends screwed and fixed complete all as specified and directed by Engineer in charge.
M&L for repair to 15 mm straight plain brass ferrules (or connecting screws) screwed both ends and fixed complete all as specified and directed by Engineer in charge.
M&L for 15mm PVC perforated caps screwed to ends of puff or vent pipes complete all as specified and directed by Engineer in charge.
S&F in repair 15mm ball brass valves high pressure with polythene flot and flynut completescred for iron pipes or brass ferrule and fix complete all as specified and directed by Engineer in charge.
S&F in repair 20mm ball brass valves high pressure with polythene flot and flynut complete screwd for iron pipes or brass ferrule and fix complete all as specified and directed by Engineer in charge.
S&F 15mm dia GI steel water tubing medium grade ISI marked laid in trenches or fixed to walls and ceilings or laid in floors with and including all fittings such as bends, elbows,tees, short pieces etc complete all as specified and directed by Engr -in- Charge.
-Ditto- all as per item No. 74 above, but fixing only old GI tubing complete all as specified and as directed by Engineer in charge..
S&F 20mm dia GI steel water tubing medium grade ISI marked laid in trenches or fixed to walls and ceilings or laid in floors with and including all fittings such as bends, elbows,tees, short pieces etc complete all as specified and directed by Engr -in- Charge.
-Ditto- all as per item No. above, but fixing only old GI tubing (20 mm bore) complete all as specified and directed by Engineer in charge.
S&F vitreous china squatting pan of (Orrisa pattern) size 580mm x 440 mm white with integral foot rests complete connection to drain ( outgoing pipe) and to flushing pipe of 32 mm dia and syphonage pipe etc and making good the floor with provn of concrete bedding in repair complete all as specified and as directed by Engr-in- Charge..
S&F PVC valve less syphonic action type, flushing cistern 10 ltrs capacity,low level white with inlet, ball valve float and handle including brackets including 32mm dia PVC flush pipe for low level cistern including all joints fixed in repair complete all as specified and directed by Engr-in- Charge..
S&F in repairs Vitreous China urinals, bowl type min size 420 x 395 x 635mm complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement fixing automatic flushing cistern with brackets,flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed by Engr-in- Charge.
S&F, as in repair, vitreous china wash basin, white flat back size 630x 450 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket or erecting stand alongwith 32mm PVC waste pipe and brass chromium plated waste coupling complete all as specified and directed by Engr-in- Charge..
Supply only, 15 mm bore pillar taps fancy type (long neck) cast copper alloy with capstan heads chromium plated screwed down high pressure with or without letter hot or cold with long screwed and shanks and fly nuts screwed for iron pipes complete all as specified and directed by Engineer in charge.
S&F for 15 mm bore stop valves chromium plated fancy type screwed down high pressure with crutch or batterfly handle screwed both ends for iron pipes or for union fixed in repair complete all as specified and as directed by Engr-in- Charge..
S&F in repairs for 15 mm bore CP angle stop valves of high pressure screwed for iron pipe and fixed complete all as specified and directed by Engineer in charge.as specified.
S&F in repairs for 15 mm bore CP push tap any colour high pressure screwed for iron pipe and fixed complete all as specified and directed by Engineer in charge.
S&F for bib tap 15 mm bore of fancy chromioum plated with long shank & cup , screwed down high pressure with crutch or butterfly, screwed both ends for iron pipe or for brass ferrule fixed in repair complete all as specified and as directed by Engr-in- Charge.
S&F 600mm x 450mm bevelled edge mirror with border, 5mm thick glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with cromium plated brass screws and cup washers complete all as specified and as directed by Engr-in- Charge.
M&L for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer in charge.
S&F Chromium plated towel rod 600 mm long fixed with and including chromium plated brass screws complete all as specified and directed by Engineer in charge.
S&F LPDE waste pipes of 32mm bore pressure rating 6 Kgf/Sqcm for wash hand basin, all as specified complete all as specified and directed by Engineer in charge.
S&F PVC connection 15mm dia sizes with PTMT nuts of length 450 mm complete all as specified and directed by Engineer in charge.
S&F Chromium plated Liquid soap container fixed with and including Chromium plated brass screws on walls complete all as specified and directed by Engineer in charge.
S&F in repairs High density polythene pipe(HDPE), 50 mm bore of pipes of pressure rating 6 Kgf /Sq cm fixed complete to wall or laid in tranches or floors etc (50 mm bore) incl all fittings complete all as specified and directed by Engineer in charge.
Demolition or breaking up drain pipe ( salt glazed ware, AC, CI, PVC or reinforcement concrete) of any dia etc complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) pipes 75mm dia in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) pipes 110mm dia in any length with rubber ring joints fixed to walls/trenches/floors etc complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) bend 110mm dia with access door bends complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) bend 75mm dia with access door bends complete all as specified and directed by Engineer in charge.
S&F PVC (SWR) junction double, (Double T) equal or unequal 110mm Dia with access door bends complete all as specified and directed by Engineer in charge.
S&F PVC (SWR) junction double, (Double T) equal or unequal 75mm Dia with access door bends complete all as specified and directed by Engineer in charge.
S&F PVC (SWR) branch piece double, (Double Y) equal or unequal 110mm Dia with access door bends complete all as specified and directed by Engineer in charge.
S&F PVC (SWR) branch piece double, (Double Y) equal or unequal 75mm Dia with access door bends complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) gully trap 110 mm dia setting and jointing with solvent cement concrete and providing connection upto 1st manhole with PVC pipe complete all as specified and directed by Engineer in charge.
S & F PVC (SWR) P traps in bore 110 mm dia complete all as specified and directed by Engineer in charge.as specified.
S&F grating 150mm dia of Chromium plated for wash basin fixed in repairs complete all as specified and directed by Engineer in charge.as specified.
M&L for Preparation of new steel surface of any description over 10 Cm in width or girth, not otherwise described applying two coats of synthetic enamel paints over a coat of red oxide zinc primer complete all as specified and directed by Engineer in charge.
M&L for cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate in foundations and mass concrete complete all as specified and as directed by Engr-in-Charge.
M&L for complete removal of exiting treatment on wooden surfaces of any description and applying two coats of french polishing over a coat of wood filler including cleaning and preparing the surface complete all as specified and as directed by Engr-in-Charge. Note:- Application of french polishing shall be got done through authorised applicator.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,Hard/dense soil. etc complete all as specified and directed by Engineer in charge.
Removing excavated soil not exc.50.0 mtr and depositing soil where directed at level not exceeding 1.5 mtr above the starting point etc complete all as specified and directed by Engineer in charge.
M&L for PCC 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) as mass concrete as in foundation of posts complete all as specified and directed by Engineer in charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting (PPGL) 0.50mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding to wall , fixed with self tapping screws etc complete all as specified and directed by Engineer in charge.
S&F 0.80mm thick plain Galvansied mild steel sheeting with 275 gm/sqm Zinc coating as in ridge, hip, valley gutters, drip and straight flashing fixed with coach screws & washer in roof etc complete all as specified and directed by Engineer in charge.
S&F wind ties for roof including securing bolts and similar articles conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer in charge.
S & F wire netting size of mesh in 25mm of stainless steel wire 1.40 mm dia fixed with tinned tacks of stainless steel wire staples, etc complete all as specified and directed by Engineer in charge.
S&F in repairs 2 mm thick Fibre glass reinforced translucent corrugated sheeting with two orrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed by Engr-in- Charge..
S & F Mild steel rolled sections as in Columns, Vertical posts etc; fixed with angle cleats or other connecting plates Fe-410- W (Gde E-250) qualityB complete all as specified and directed by Engr-in- Charge.
S&F Mild steel roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. Fe-410 W(Gde E-250) complete all as specified and directed by Engr-in- Charge..
Surface excavation not.exc. 30 cm deep and averaging 15cm deep and getting out in soft disintegrated rock complete all as specified and as directed by Engr-in- Charge.
M&L for Cement concrete100 mm thick, type D2 1:4:8 (40 mm graded aggregate)in foundations, filling and mass-concrete complete all as specified and as directed by Engr-in- Charge.
M&L for machine pressed precast ruberised glossy concrete interlocking paver block any shape and size with grey cement and pigment conforming to IS15658-2006 of 60mm thickness , M-35 Grade laid over 50 mm thick sand cushioning to interlocking paver block complete all as specified and directed by Engr-in-Charge.
M& L precast cement concrete 1:3:6 Type C1 (using 20 mm graded aggregate) as in kerb stone etc.(of any section) with plain fair faces, including chamfers weatherings, throating etc. and setting in mortar complete with joints to match set in CM 1:6 complete all specified and as directed by Engr-in-Charge.
M&L for Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engr-in-Charge.
M & L for TMT bars 6 to 8mm dia and over cut to length bent to shape required including cranking bending spirally or hooping as in reinforcement , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90mm dia complete all as specified and directed by Engr-in-Charge.
M&L 150mm bore RCC pipes class NP-2 laid and jointed complete with collars with new PCC bed complete all as specified and as directed by Engr-in-Charge. (Note :- PCC bed shall be measured and paid seperately)
M&L for PCC 1:4:8 type D2 using 40mm graded agg to 150mm bore drain pipes incl packing under and haunching against the sides after they are laid & tested complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for manhole covers, slabs etc complete all as specified and as directed by Engr-in- Charge.
Cutting into existing manholes for connecting nw drains and rendering, cutting out branch channel and making good to pipe and rendering, cutting out existing benching for and forming branch channel in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as 150 mm Bore( Internal diameter ) complete all as specified and as directed by Engr-in- Charge.
M&L precast cement concrete (1:2:4), type B1 using 20 mm graded crushed stone aggregate as in cover slab for Manhole and setting in cement mortar 1:4 including necessary form work complete all as specified and directed by Engineer in charge.
S&F in repairs Powder Coated aluminium frame (any colour) for partitions, doors, windows, ventilators with one or more rebates including joining cleat for fixing etc.(sealing of window/door frames with sillicon gel to avoid rain water entry) complete all as specified and as directed by Engr-in- Charge.
S&F Powder Coated (any colour) aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges, anodised aluminum snap beading screws including floor door closer mechanism etc. complete all as specified and as directed by Engr-in- Charge.
S&F Powder Coated (any colour) aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc.complete all as specified and as directed by Engr-in- Charge.
S&F Powder Coated (any colour) aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed by Engr-in- Charge.
S & F in galvanised mild steel wire cloth 0.45 mm nominal dia of wire and average width or aperture 1.40mm and fixed with tinned tackles or galvanished wire complete all as specified and as directed by Engr-in- Charge.
S&F sheet frosted glass 5.5 mm thick and glazing with rubber beading in Square not exc 0.5 Sq.m in each pane complete all as specified and directed by Engr-in- Charge.
S & F Sheet Glass, Ordinary quality 5.5 mm thick and glazing with rubber beading in Square not exc 0.5 Sq.m in each pane complete all as specified and directed by Engr-in- Charge.
S&F 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work to timber/rubber beading to Aluminium framework in Partition or Wall Panelling complete all as specified and as directed by Engr-in- Charge.
M&L Double action floor spring hyrraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass, other pats made of mild steel heavy duty and fixed complete all as specified and as directed by Engr-in- Charge.
S&F for floor door stopper of brass body and tongue, anodised with hard drawn steel spring, fixed in floor complete all as specified and as directed by Engr-in- Charge.
Supply and installation of sensor operated motorised double leaf sliding door size 2.4m x 2.40 m including all acessories / fittings complete all as specified and directed by Engr-in- Charge and all as per manufacturer instructions & specifications given below:- (i) Door panel shall be of 12 mm toughened glass (frameless) (ii) Sensor / microwave radar both ways ( range 2 mtr radius) (iii) Built in photocells for reversal safety ( 1 pair) (iv) Extruded anodized aluminium profile sliding guide & casing (v) Sliding on reinforced nylon wheels (vi) Gear motor with encoder. Rated power 70W (vii) Power supply 230 V / 50 -60 Hz (viii) Door opening / closing Max spee 1.6 m/S ( 2 leaves) (ix) Accessories power supply 12 VDC ( 1 A max) (x) Encoder ( Built in electronic anticrush device) (xi) Rubber sealing on front edge of doors (xii) Stainless steel sliding fittings Note:- Any other mechanical part/fitting / accessories required to make the door functional is deemed to be included in the quoted rate.
S&F 6mm thick Aluminium Composite Panel System (ACP) sheeting fix to wall and ceiling including Aluminium framing using 50mm x 25mm plane rectangular aluminium tube wall thickness not less than 1mm fixed to wall with metal fastners / bolts and weatherproof 789 silicon filling to joints as per manufacturer instruactions including all necessary scaffolding for erection complete all as specified and directed by Engr-in- Charge.
M&L for 5mm thick Epoxy polyurethane flooring ( ESD flooring) which includes 3mm base coat over one coat of primer, copper strip and corbonated layer and 2mm top coat and also rate includes the roughing and grinding of top surface of existing flooring and cleaning and making good for primer and testing of EPU flooring as per required range of ressistivity complete all as specified and as directed by Engr-in- Charge.
M&L for 50mm thick PCC 1:2:4 type BO using 12.5mm graded crushed stone aggregate as in copings with fair finished surface as directed including necessary form work complete all as specified and directed by Engr-in- Charge.
Taking down the existing surface batten type point wiring of aluminium for Light, fan, Sockets, power sockets, stair case light point complete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc complete all as specified and as directed by Engr-in- Charge.
Taking down the sub main wiring of any dia / sq mm on teak wood batten / PVC conduit GI earth wire complete all as specified and as directed by Engr-in- Charge.
Taking down cearfully by unscrewing the unserviceable DB Boxes, MC distribution boards SP & TPN with porcelain cutouts etc complete all as specified and as directed by Engr-in- Charge.
Taking down existing tube light fittings and disconnecting connection cable ends complete all as specified and as directed by Engr-in- Charge.
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing switches / sockets of the following complete all as specified and as directed by Engr-in- Charge.
One light point controlled by one switch.
One Exhaust/Wall mounted /Ceiling point controlled by one regulator/switch
One 3 pin socket 5 A on independent board.
One 3 pin socket 5 A onsame board.
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded FRLS PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping 25mm size with all fittings/fixture etc fixed wall and open recessed type Plastic switch board) made of robust Synthetic material Fire Proof, Anti corrosive & shock proof ISI Marked complete for housing one 15 A Switch / sockets complete all as specified and as directed by Engr-in- Charge.
S&F Vertical double door Distribution board TPN 4 way 200 A rated busbar consisting of MCCB. 100A 10KA complete all as specified and as directed by Engr-in- Charge.
Supply and fix sheet metal enclosure MCB DB double door SPN 12 way 230 V with neutral link and 200 A bus bar complete all as specified and as directed by Engr-in- Charge.
Supply and fix sheet metal enclosure MCB DB double door SPN 8 way 230 V with neutral link and 200 A bus bar complete all as specified and as directed by Engr-in- Charge.
Supply and fix sheet metal enclosure MCB DB double door SPN 4 way 230 V with neutral link and 200 A bus bar complete all as specified and as directed by Engr-in- Charge.
Supply and fix MCB SPN 40 Amp, 230 volt 'C' series complete all as specified and as directed by Engr-in- Charge.
S&F MCB SP 240 volt 6 to 32 A 'C' series complete all as specified and as directed by Engr-in- Charge.
Supply and fix switch piano flush type 5 A one way complete all as specified and as directed by Engr-in- Charge.
Supply and fix socket 2 in one, 5 Pin 5 Amps complete all as specified and as directed by Engr-in- Charge.
Supply and fix switch socket combination multipurpose 3 pin 6/16 Amps complete all as specified and as directed by Engr-in- Charge.
Supply and fix ceiling rose surface type bakelite/PVC three terminal 65x50mm complete all as specified and as directed by Engr-in- Charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size ccomplete all as specified and as directed by Engr-in- Charge.
Supply and fix high quality indoor Surface and wall mounted LED batten 20 Watt, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10%. complete with all accessories internally pre-wired and including connecting up with three core 0.5 Sqmm flexible copper conductor cable ceiling rose to fitting terminal complete all as specified and as directed by Engr-in- Charge.
Supply and fix indoor LED tube light fitting 36 Watt 4 feet long quality illumination and superior optical control suitable to fix in ceiling or to fix directly in hanging including nacessary arrangement for suspention, jointing kit and making nacessary arrangment for sizeing of existing Ceiling as required on site for presentable look making nacessay electrical connection with 3 core copper wire complete all as specified and directed complete all as specified and as directed by Engr-in- Charge.
Supply and fix Energy efficient recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 5700/6500K colour temperature with current electronic connections as directed complete all as specified and as directed by Engr-in- Charge.
Supply & fix wall mounted fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and as directed by Engr-in- Charge.
Supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed by Engr-in- Charge.
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V , 1400 mm sweep complete all as specified and as directed by Engr-in- Charge.
Supply & fix heavy duty exhaust fan 380mm sweep, 1400 RPM, turbo force SP, 230 volts complete all as specified and as directed by Engr-in- Charge.
S & F MCCB, 4P, 63 Amp, 16 KA with sheet metal enclosures complete all as specified and as directed by Engr-in- Charge.
Supply, laying, jointing, testing and commissioning of LT under ground cable 25 Sq mm 4 core, 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles/and steel structure etc as required on site with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified and as directed by Engr-in- Charge.
M&L for cement concrete (1:4:8) type D2 in foundation filling and mass concrete using 40mm graded stone aggregate for making good the desturbed floor/wall /duct surface or any foundation work as required on site etc complete all as specified and as directed by Engr-in- Charge.
M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40mm graded stone agg for making good the desturbed floor/wall /duct surface or any foundation work as required on site etc complete all as specified and as directed by Engr-in- Charge.
M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles incl necessary form work using 20 mm graded stone aggregate for making good the desturbed floor/wall /duct surface or any foundation work as required on site etc complete all as specified and as directed by Engr-in- Charge.
Supply and fix 40mm bore GI tubing Light grade laid in trenches / floor / fixing on pole wall with all connected accessories complete all as specified and as directed by Engr-in- Charge.
M&L for spray painting of indoor/outdoor panels any size / any type with two coats of synthetic enamel paint after rubbing with emery paper and one coat of metal primer including cleaning of oils, dust and rust partical of the exisiting fitted matels parts complete including minor repair and welding/ brazing of hinges etc complete all as specified and directed by Engineer-in-Charge.
Taking out carefully by disconnecting Electrical / data cables connectionos from existing panels/DBs of old UG cables or wires of any size and capacity with MS/GI pipes /PVC conduit pipes of any size from existing wall after unscrewing screws, removing clamps and refixing the same properly for good layout on wall / floor by using new clamps and screws of suitable size as requred on site or as to fit in cable trays size and re-connecting all connections properly complete all as specified and as directed by Engr-in- Charge.
Taking down ceiling/wall/air circulator /padestal fans any type and size from the site by disconnecting all electrical connection ,and cleaning , rubbing by emery paper , servicing , oiling , greasing incl replacing small parts like bush/bearing etc and applying two coat spray painting complete and refixng on site making all nacessary connecrtion and testing for smooth functioning complete all as specified and as directed by Engr-in- Charge.
Supply and Install hi wall split units indoor/outdoor complete with remote control unit and with in built air ioniser and plasma filter for better indooor air quality of capacity 1.5 Ton inverter based Spilt Air Conditioners having copper tubing outdoor condensing unit incl wall mounting bracket working on 230 volts, 50 Hz, refregerent -R-134A/R-410a, Noise Level –Less than 40 db Mounting/ Fitting indoor & outdoor units at the respective locations as per standard practice including suitable copper tubing connection of reqd length and size including making necessary hole in stone wall for passing copper pipes and drain pipes etc and thermal insulation Leak testing and additional refrigerant charge if required. electric driven single phase BEE 5 star rated complete all as specified and as directed by Engr-in- Charge.
ditto all as per item No. 174 above but minimum 4 star rated of Capacity 2 Ton complete all as specified and as directed by Engr-in- Charge.
Suppy and fix automatic boost buck transformer for low and high Voltage correction equipped with electronic transistorised relay suitable for correction, single phase AC supply complete with volt meter and designed for input voltage 170 Volts to 250 Votls and output voltage stablized between 215 Volts to 240 Volts of capacity 5 KVA complete all as specified and as directed by Engr-in- Charge.
S&F Hot Dip galvanised solid perforated cable tray and cover of width 450 mm, depth 100 mm and thickness (12 SWG) fabricated from GI sheet GI coupler plate and hardware and all nacessary Vertical or horizontal fixing arrangements as required on site complete all as specified and as directed by Engr-in- Charge.
S&F Hot Dip galvanised perforated cable tray and cover of width 100 mm, depth 25 mm and thickness (16 SWG) fabricated from GI sheet GI coupler plate and hardware and all nacessary Vertical or horizontal fixing arrangements as required on site complete all as specified and as directed by Engr-in- Charge.
M&L for sub main wiring with two runs of single core 4.0 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 650 / 1100 V grade with colour code and one run of 2.5 Sq mm ( 22 / 0.3 mm ) single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor including PVC casing & caping all as directed. ( Note :Two runs of 4.0 Sqmm copper cable,one run of earth wire of 2.5 Sqmm copper cable shall be measured & paid as one length.) complete all as specified and as directed by Engr-in- Charge.
Supply & fix aluminium strips 25x3.15 mm on porcelin insulator 15 BMD type 'T' placed not more than 50 cm apart complete all as specified and as directed by Engr-in- Charge. ( Note : Porcelain insulators with nuts bolts and screws will measured and paid separatly under relavent items)
S&F DMC porcelain insulators of size 20x3.15 mm T type with nut bolts / screws for fixing of copper/aluminium/GI strips on walls/Roof etc complete all as specified and as directed by Engr-in- Charge.
S&F test point terminal block made out of gun metal or phosphorous bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, , cutting upper & lower portion for incoming & outgoing including double insulators two coat of synthic enamel paint complete all as specified and as directed by Engr-in- Charge.
Supply and fix air termination rod single pointed aluminium 12 mm dia & 300 mm long complete all as specified and as directed by Engr-in- Charge.
S&F GI earth strips 32 mm x 6 mm fixed on procelane insulator fixed on wall using cadmium plated screw or laid in tranches complete all as specified and as directed by Engr-in- Charge.
Supply and errect vertically GI steel tubing 40 mm bore medium grade complete with fittings for raising height of existing air termination rods to site present requirements complete all as specified and as directed by Engr-in- Charge.
M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32x6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified and as directed by Engr-in- Charge. Note:- (i) Venders are bound to get earthing result upto 5 Ohm for single earthings and 3 Ohm with the grid of two earthing.Any additional work and material required to achive the required result is included in the cost deemed to be quoted rate by Contractor. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with M&L for black cotton soil 1 cum. (iv) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Supply, Installation Testing & Commissioning of microprocessor based 2 Loop Expandable to 8 loop Networkable Analogue Addressable Fire Alarm Control Panel. The Panel shall be compliant with EN54-2, EN54-4 and approved by LPCB. The Panel must have Full colour 800 x 480 LCD with resistive touch screen and automatic backlight dimming. The Panel must also have the capability to take Addressable Intelligent Wired and Wireless Devices on same loop. Each loop shall have a capacity of 127 analogue Addressable devices and 127 Base sounders/Base Sounder Beacons. The panel shall have an event log of minimum 10,000 events @ 1 second resolution, Filterable and Printable. The Panel shall have Three access levels. Panel shall support upto 5000 Cause & Effects entries, with upto 20,000 inputs controlling & 20,000 Controlling outputs across the network. The Panel shall have capability for Peer to Peer networking through RS485 network card. The Panel must have 4 inbuilt programmable sounder circuits, each circuit rated at 2.5A.The Panel must have inbuilt 3 programmable inputs and 5 inbuilt programmable relay outputs. The Panel shall have up to sub- addressable 512 programmable Inputs/Outputs via optional RS485 COMMS serially connected expansion cards. The Panel shall have 240 V AC power supply along with automatic Battery Charger. The Panel shall be fully expandable via common plug in loop driver boards. The user shall have a choice of using the panel with 5.25 Amp or 10.25 Amp power supply unit which is inbuilt in the FACP and should be approved to EN54-4. The Panel shall have configurable via USB port to PC or SD card slot. The Panel shall have dedicated RS232 serial port for optional printer. complete all as specified and directed by engir in charge.
Supply, Installation, Testing and commissioning base Fault Isolator fully monitored for short/Open circuit compatible with Analogue Addressable Protocol,Electronically addressed, approved by LPCB,unit incorparates an amber LED to show when it is islating a section of a Loop complete all as specified and directed by engir in charge.
Supply & laying of ISI marked 2 core x 1.5 sq mm Multistrand. Copper, FRLS PVC insulated Armoured Cable, Red in colour with required end termination using gland, lugs, cable tag & required accessories. Two module metal box. complete all as specified and directed by Engr-in-Charge
Material and labour for 3 Amp 24 Volt Power Supply for fault isolator module as required on site complete all as specified and directed by Engr-in-Charge
Supply and laying High density polyethylene pipes (HDPE) of size 40 mm and pressure rating 6 kgf/cm2 laid in trenches
Supply & fixing recess mounted downlighter 18 with pressure die cast aluminium heat sink PC diffuser in white powder coated finish with integral electronic driver low THd less than 10% LED driver making all necessary arrangement for fixing making electrical connection complete all as specified and as directed by Engr - in - Charge.
M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to including galvanised GI wire 4mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip wire 4mm with GI protection pipe of 20 mm medium grade 7.5 meter long, etc complete all as specified and as directed by Engr-in- Charge. Note:- (i) Vendors are bound to get earthing result upto 5 Ohms for each earthing. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with M&L for black cotton soil 1 cum. (iv) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost
M&L for providing earthing complete with copper earth plate electrode 600mm x 600mm x 6.15mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including copper strip 20 x 3 mm as earthing lead by means of bolts, nuts, check nuts & washers etc connected to earthing test point providing charcoal and common salt all as shown in electrical plate No 3 of SSR Part I of 2009 and as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber precast slab 50mm thick in cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/Sqm funnel with wire mesh, watering pipe of 20mm bore medium grade and lugs including copper strip upto 7.5m long complete all as specified and directed by Engr-in-charge. Note:- (i) Venders are bound to get earthing result upto 5 Ohm for single earthings and 3 Ohm with the grid of two earthing.Any additional work and material required to achive the required result is included in the cost deemed to be quoted rate by Contractor. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with M&L for black cotton soil 1 cum. (iv) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
S&F copper earth continuity conductor or main earthing lead of size 20 x 3mm fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for earthing etc as required complete all as specified and directed by Engr-in-charge.
S&F porcelain insulators with nut bolts/screws for fixing of copper strips on walls etc complete all as specified and directed by Engr-in-charge.
shah construction
OM INFRA
Smruti Construction
M/S V C SHETH
KARNI BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .