GE 864 EWS
GE 864 EWS C/O 56 APO
REPAIR/MAINTENANCE OF LT DISTRIBUTION SYSTEM AND LT VOLTAGE STABILIZER OF DIFFERENT CAPACITY INCLUDING ALLIEDWORK AT BB CANTT, SRINAGAR.
2026_MES_791714_1
864/WS-91(T)/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 864 EWS
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹76,000
Yes
29 Sept 2026
29 Sept 2026
27 Oct 2026
29 Sept 2026
20 Oct 2026
13 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for servicing and prevantive maintenance of solar Power plant of capacity 35 KW including cleaning of Solar PV modules, testing of batteries , inspection and tighening of all electrical connection, checking of DC/AC Cables, connector, junction boxes, earthing system, and protection device , inspection and testing of solar inverter, mounting structure ,generation monitoring system ,any minor defects observed during servicing shall be rectified to ensure safe , efficient and uninterrupted operation of the solar power plant, complete all as specified and directed to entire satifaction of Engineer in charge. Note:1. Servicing , testing and inspection report shall be produce by contractor with specified vendor. 2. If battery found unsericeable condition , it shall be measured and paid separatly. | 1 | EACH JOB | - | - |
| 2 | S& F in replacement of HBL Power system T-Gel (TGEL) series maintenance free batteries 240 V, 200 AH suitable for solar plant, complete all as specified and directed. | 10 | EACH | - | - |
| 3 | Trimming of tree branches touching with LT over head line in the entire cantonment so as to maintaining sufficient clearance and avoid fault on over head lines, complete all as specified and directed. | 100 | EACH SPAN | - | - |
| 4 | M&L for Stretching of Over head line four conductor complete in cantt area including fixing of spacer in between four conductor for maintening clearance and to be avoid fault on over head lines, complete all as specified and directed. | 100 | EACH SPAN | - | - |
| 5 | Repair / overhauling of electrical control panel board including addition alteration in wiring system complete with of defective parts such as volt meter Ammeter, frequency meter indicating lamps with wiring etc., complete all as specified and directed.
Note :- Cost of spares shall be measured and paid separatly. | 5 | EACH JOB | - | - |
| 6 | Taking out the unserviceable volt meter of any type and size and supply and fixing volt meter with selector switch 6 step (0-500 volt) including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified and directed. | 5 | EACH | - | - |
| 7 | S&F in replacement Indicator lamp neon type red, yellow & blue, complete all as specified and directed. | 8 | SET OF THREE | - | - |
| 8 | Repair & maintenance of LT Panel board indoor/ outdoor type comprising of MCCBs as incoming and outgoing with digital mettering and control wiring by disconnecting all incoming and outgoing connection, opening of LT cable incl refixing of cables after proper lugging and glands complete. Cleaning of all compartment from in side and out side including using anti rust spray and checking and repair of all controls, switches, meters. etc (if found diffective) and painting complete panel board with two coat of synthetic enamel paint over a coat of red-oxide paint, after necessary scrapping and denting. Refixing of panel board upon angle iron frame of size 50x50x6mm and embeded in PCC concrete of ratio (1:3:6) type B2 (using 40mm graded crushed stone aggregate) including welding work for front/rear door, complete all as specified and as directed. Note: 1. The MCCBs, MCBs, volt meter, amp meter will be measured and paid saperately .
2. The charges for 50x50x6 mm angle iron frame & PCC work is deemed to be included in above quoted rates. | 4 | EACH JOB | - | - |
| 9 | Supplying, laying ,testing and commisioning of LT Aerial Bunch Cable (abc) of size 50 Sqmm ,suitable for1.1 KV grade ,complete with all accessories , including suspension clamp ,dead end clamp, insulation piercing connector (IPC) anchor clamp,support brackets,lugs,glands and other required hardware, complete all as specified and directed. | 250 | RUNNING METRE | - | - |
| 10 | Description all as per serial item No 9.00 here-in-before, but size 95 Sqmm, complete all as specified and directed. | 150 | RUNNING METRE | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
Tender91_merged.pdf
Tender Documents • 1.13 MB
BOQ_887636.xls
BOQ • 1.74 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .