Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC | ₹7.1 L | L1 | Accepted-AOC BEING LOWEST BIDDER |
| 2 | L2₹8.1 L+₹1.0 L (14.6%)Rejected-Finance BASGO LEH 194 101 U T LADAKH INDIA | LEH LADAKH | LADAKH | 194101 | ₹8.1 L+₹1.0 L (14.6%) | L2 | Rejected-Finance BEING NOT LOWEST BIDDER |
| 3 | L3₹9.0 L+₹1.9 L (26.6%)Rejected-Finance | ₹9.0 L+₹1.9 L (26.6%) | L3 | Rejected-Finance BEING NOT LOWEST BIDDER |
| 4 | L4₹9.1 L+₹2.0 L (28.2%)Rejected-Finance AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | ₹9.1 L+₹2.0 L (28.2%) | L4 | Rejected-Finance BEING NOT LOWEST BIDDER |
| 5 | L5₹9.1 L+₹2.0 L (28.9%)Rejected-Finance VILL NIMOO LEH LADAKH 194101 | NIMOO | LEH | LADAKH | 194101 | ₹9.1 L+₹2.0 L (28.9%) | L5 | Rejected-Finance BEING NOT LOWEST BIDDER |
Tender Value
₹7.9 L
EMD Value
₹16,000
Closing Date
5 Nov 2024, 6:00 pmClosed
AGE (I) NIMU
AGE (I) NIMU PIN-901312 C/o 56 APO
SPL REPAIR TO TOILET BLOCK NP36 AT BDE HQ AT NIMU MIL STN AND PROVN OF 02XURINAL AND ATT BATHROOM AT REAR OF BLDG NO T136 OF 118 BDE GP SIG COY AT NIMU MIL STN UNDER AGE (I) NIMU
2024_MES_679612_1
AGE (I)/NIT-21/2024-25
Open Tender
Civil Works
Item Rate
180 days
NIMU
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
AGE (I) NIMU
₹16,000
27 May 2025
15 Oct 2024
6 Nov 2024
15 Oct 2024
5 Nov 2024
22 Oct 2024
Amount
Spl repair to toilet Block NP-36 at Bde HQ at Nimu Mil Stn
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing), removing and rubbish off the premises deposited in low laying area all as specified and directed by Engr-in-charge.
M&L joint free non skid ceramic tiles " coloured" 7 to 8mm thick ( Square/rectangular ) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm in floors etc.set and jointed in neat cement slurry and pointed in white cement incl 15mm thick screed bed in CM 1:4 complete all as specified.
M&LGlazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick over 15mm thick plastering in cement mortor 1 : 4, set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed by Engr-in-charge
Demolition in precast cement concrete walling built in cement mortor including all quoins, arches, pillars, etc all as specified.
Taking down plastering on lathing (other than wire-netting), without removing lathing, incement lime or cement mortar (one side only measured in cases where both sides are plastered) cement all as specified and directed by Engr-in-charge.
M&L for PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate ) block masonry with solid block exc 10cm in width and set as in wall etc in CM 1:4 complete all as specified and directed by EIC
M&L for Rendering 10mm thick on fair faces of brickwork or concrete surfaces in cement mortar (1:6) and finished even and smooth without using extra cement all as specified and directed by Engr-in-charge.
M&L preparing new plastered surfaces of walls and applying two coat white wash on walls all as specified and directed by Engr-in-charge.
M&L preparing new plastered surfaces of walls and applying two coat cement paint on walls all as specified and directed by Engr-in-charge.
S & F in repair for 15mm PVC connection of 600mm long complete all as specified and directed by Engr-in charge.
S&F in repair 15mm Angle cock/Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in charge.
S & F in repair 15mm dia Pillar taps cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed fancy type complete all as specified and directed by Engr-in charge.
S&F in repair vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed by Engr-in charge.
S&F in repair vitreous china wash basin white flat back size 550x400mm ovel type/round /any shape (including tap, waste chain and plug and porcelain stopper and brackets all complete complete all as specified and directed by Engr-in charge.
S&F in repair Waste fittings 32 mm, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed by Engr-in charge.
Disconnecting existing tanks exc 250 & n. exc 500 litre capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and directed by Engr-in charge.
S&F in repair Rotational moulded polyethylene water storage tanks 500 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engr-in charge.
S&F in repair Nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) 25 mm complete all as specified and directed by Engr-in charge.
S&F in repair PP-R Ball valves 25mm (brass insert) as per requirement of the site complete all as specified and directed by Engr-in charge.
S&F in repair PP-R Gate valves 25mm (brass insert) high pressure, with polythene float and flynut complete, as per requirement of the site complete all as specified and directed by Engr-in charge.
Taking up or down steel water tubing and connections 20mm dia, including cleaning for refixing or removal to store complete all as specified and directed by Engr-in charge.
S&F 3-layer PP-R Polypropylene random copolymer) concealed pipes 25 mm Outer dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed by Engr-in charge.
Taking down Chowkhats or frames not exc. 1.5 sq. m with shutters (without taking off shutters from the frames) each complete all as specified and directed by Engr-in charge.
Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m with shutters (without taking off shutters from the frames) each complete all as specified and directed by Engr-in charge.
S&F 2nd class soft wood in plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed by Engr-in charge.
S&F 2nd class soft wood in plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed by Engr-in charge.
S&F Sheet glass 4mm th, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed by Engr-in charge.
M&L for Preparation of new or previously untreated wood Surfaces of any description over 10cm girth or width, not otherwise described and applied two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in charge.
Demolition cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in charge.
M&L for cement concrete 75mm thick in plinth protection or similar work type C-2, 1:3:6 (40mm graded aggregate) complete all as specified and directed by Engr-in charge.
Excavation in trenches, not exceeding 1.5 m wide and not exc 1.5 m in depth for foundation, laying of pipes etc and not exceeding 10 sqm on plan for manholes etc and getting out in hard/ dense soil, complete all as specified. and directed by Engr-in-Charge.
Excavation over area n exc not exc 1.5 m in depth and getting out in hard/ dense soil, complete all as specified and directed by Engr-in-Charge.
Extra over item here in before for Each addittional 1.5 m depth or part thereof in depth beyound the first 1.5 m depth, complete all as specified and directed by Engr-in-Charge.
Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25 Cm thick, complete all as specified and directed by Engr-in-Charge.
Removing surplus excavated soil to a distance exceeding 50 m & n exc 250 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by Engr-in-Charge.
Cement concrete 1:4:8 type D2 (40 mm graded crushed stone aggregate ) in foundations, filling and mass concrete, complete all as specified and directed by Engr-in-Charge.
Cement concrete 1:2:4 type B2 (40 mm graded crushed stone aggregate ) in foundations, filling and mass concrete, complete all as specified and directed by Engr-in-Charge.
PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor of 110mm bore pipe, complete all as specified and directed by Engr-in-Charge.
PVC (SWR) vent cowl 110mm in bore, complete all as specified and directed by Engr-in-Charge.
PVC (SWR) bends any radius of 110mm bore, complete all as specified and directed by Engr-in-Charge.
PVC (SWR) junction single,(single T), equal or unequal of 110mm bore, complete all as specified and directed by Engr-in-Charge.
PVC (SWR) 'P' trap 110/110 mm bore, complete all as specified and directed by Engr-in-Charge.
Stone masonry walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, bulit in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge.
Stone masonry walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, laid dry as directed , complete all as specified and directed by Engr-in-Charge.
TMT bars 10 mm dia and over, cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia , complete all as specified and directed by Engr-in-Charge.
Use & waste form work to soffits of suspended slabs, such as roof slabs, landings and similar work not exceeding 200 mm thick with rough finished flat surfaces of concrete, complete all as specified and directed by Engr-in-Charge.
Demolition of RCC of any description and in any position including disposal of old materials to a distance exceeding 500 M but not exceeding 1.0 KM, complete all as specified and directed by Engr-in-Charge.
RCC 1:2:4 type B-1 ( using 20 mm graded crushed stone aggregate ) as in slabs supported on walls, beams and columns in floors, roofs, complete all as specified and directed by Engr-in-Charge.
Precast reinforced cement concrete, type B-1,1:2:4 (using 20mm graded crushed stone aggreagate)as in manhole cover set in cement mortor 1:4 , complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete 75mm thick in plinth protection or similar work type C-2, 1:3:6 (40mm graded aggregate) complete all as specified and directed by Engr-in charge.
Taking down carefully aluminium point wiring light, fan socket or power complete fitting such as switches, ceiling rose, fan regulator, socket including light fitting etc complete with MS conduit and T/W battern and depositing to MES store yard all as specified and as directed by Engineer-in-Charge.
M&L for point wiring with PVC insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed for following :-
(a) One light point/one fan point controlled by one switch
(b) One 3 pin 5 amps socket outlet same board with cables 1.5 sqmm size
(c) One 3 pin 5 amps socket outlet independent with cables 1.5 sqmm size
All same as per item No 2 above but with conductor of size 4 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 4 sqmm PVC insulated stranded copper conductor Cable.
S&F switch Socket Combination 2 in 1, 3 pin, 5 and 15 amp flush type Universal
S&F Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal
S&F socket outlet 2 in 1, 3 pin, 6 Amp flush type complete all as specified and directed.
S & F Switch piano, flush type 6 Amp, single pole, one way complete all as specified and directed.
M&L for ceiling rose surface Bakelite 65x50mm two to three terminal complete all as specified and as directed by Engr-in-Charge.
S&F in repair basic all purpose surface and wall mounted LED batten with polycarbonate housing and integreted electronic driver of cap 20 watt, 4 feet long, with all accessories complete all as per specified and as directed by Engr-in-Charge.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete.
S&F sheet metal powder coated versatile Double door SPN distribution board, 8 way suitable for MCB's fitted with copper bus bar rated 200amps, neutral link , earth bar and din rail suitable for use on 240 Volt, 50Hz .
Supply and fixing SPN 63 Amp rating 240V, 10KA 'C' curve (MCB) of poles and current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed.
S&F in repairs to MCB SP 6-32 Amp with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
S & F in repair LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to galvanized earh lead wire of size 4.0 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified.
Supply and fixing in 1100 Volts grade heavy duty cable PVC insulated aluminimum conductor of size 16 Sq mm twin core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, flat or circular all as specified and directed.
Provn of 02xUrinal & att Bathroom at rear of Bldg No T-136 of 118 Bde Gp Sig Coy at Nimu Mil Stn
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil
M & L Cement concrete 1:4:8 type D2 (40 mm graded crushed stone aggregate ) in foundations, filling and mass concrete complete all as specified. and directed by Engr-in-Charge.
M&L for Pre-cast cement concrete 1:3:6 type C1 (using 20mm graded agg) block masonry with solid blocks, exc. 10 cm in width and setting in mortar (1:4), complete
M&L for rendering 15mm thick in CM(1:4) on fair faces of brick work or concrete surfaces finished even and smooth (without using extra lime or cement)
M&L for rendering 10mm thick in CM(1:6) on fair faces of brick work or concrete surfaces finished even and smooth (without using extra lime or cement)
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil.
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
M&L preparing new plastered surfaces of walls and applying two coat of cement base paint over a coat of primer all as specified and directed by Engr-in-charge.
Use and waste of Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete ilings,openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontalor sloping and similar work exc 10cm but n exc 20cm wide
M&L for TMT bars 10 mm dia and above, cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia , complete all as specified and directed by Engr-in-Charge.
M&Lfor RCC 1:2:4 Type B-1 (using 20mm graded aggregate) (Nominalmix) as in Slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like as in water tank slab
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base
Rolled mils steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 410 -W (Gde- E- 250) quality-A
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified
M&L applying two coat of synthetic enamel painting to new surface steel based over a coat of red oxide primer exc. 10 cm width/grith including preparation of surfaces, including filling with filler where reqd all as specified and directed.
M&L joint free non skid ceramic tiles " coloured" 7 to 8mm thick ( Square/rectangular ) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm in floors etc.set and jointed in neat cement slurry and pointed in white cement incl 15mm thick screed bed in CM 1:4 complete all as specified.
M&LGlazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick over 15mm thick plastering in cement mortor 1 : 4, set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed by Engr-in-charge
M&L 2nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed by Engr-in-charge.
M&L 2nd class hardwood 35mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats for doors complete all as specified and directed by Engr-in-charge.
M&L 2nd class hardwood 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed by Engr-in-charge.
S & F 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed by Engr-in-charge.
M&L for preparation of new wood surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coats of Synthetic enamel (ordinary tint) over a coat of pink primer complete all as specified and directed by Engr-in-charge.
S&F Mild steel 100mm long Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed by Engr-in-charge.
S&F Mild steel 75mm long Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed by Engr-in-charge.
S&F extruded aluminium alloy handles, fabricated type, anodised 150mm long complete all as specified and directed by Engr-in-charge.
S&F extruded aluminium alloy handles, fabricated type, anodised 100mm long complete all as specified and directed by Engr-in-charge.
S&F Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed 250mm long complete all as specified and directed by Engr-in-charge.
S&F Aluminium anodised, barrel tower bolt of extruded section and fixed, 150mm long (ISI marked), complete all as specified complete all as specified and directed by Engr-in-charge.
S&F Aluminium anodised, barrel tower bolt of extruded section and fixed, 75mm long (ISI marked), complete all as specified complete all as specified and directed by Engr-in-charge.
S&F Rotational moulded polyethylene water storage tanks 500 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engr-in charge.
S&F 3-layer PP-R Polypropylene random copolymer) concealed pipes 25 mm Outer dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed by Engr-in charge.
S&F Nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) 25 mm complete all as specified and directed by Engr-in charge.
S&F PP-R Ball valves 25mm (brass insert) as per requirement of the site complete all as specified and directed by Engr-in charge.
S & F for 15mm PVC connection of 600mm long complete all as specified and directed by Engr-in charge.
S&F 15mm Angle cock/Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in charge.
S & F 15mm dia Pillar taps cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed fancy type complete all as specified and directed by Engr-in charge.
S&F vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed by Engr-in charge.
S&F vitreous china wash basin white flat back size 550x400mm ovel type/round /any shape (including tap, waste chain and plug and porcelain stopper and brackets all complete complete all as specified and directed by Engr-in charge.
S&F Vitreous china wash down water closed pan " Pedestal Pattern" white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flush pipe and joint arrangements with fixing bolts etc including making good the distrubed portion of floor in cement concrete 1:2:4 type B-0, asin repairs complete all as specified & directed by Engr-in-charge.
S&F PVC valveless 10 ltr cap, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets
M&L for 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete as in partition wall between urinal.
M&L for cement concrete 75mm thick in plinth protection or similar work type C-2, 1:3:6 (40mm graded aggregate) complete all as specified and directed by Engr-in charge.
M&L for cement concrete 1:3:6 Type C2 (40mm graded aggregate) 100mm thick in sub base of flooring complete all as specified and directed by Engr-in charge.
PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor of 110mm bore pipe, complete all as specified and directed by Engr-in-Charge.
PVC (SWR) vent cowl 110mm in bore, complete all as specified and directed by Engr-in-Charge.
PVC (SWR) bends any radius of 110mm bore, complete all as specified and directed by Engr-in-Charge.
PVC (SWR) junction single,(single T), equal or unequal of 110mm bore, complete all as specified and directed by Engr-in-Charge.
PVC (SWR) 'P' trap 110/110 mm bore, complete all as specified and directed by Engr-in-Charge.
Stone masonry walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, bulit in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge.
Stone masonry walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, laid dry as directed , complete all as specified and directed by Engr-in-Charge.
Use & waste form work to soffits of suspended slabs, such as roof slabs, landings and similar work not exceeding 200 mm thick with rough finished flat surfaces of concrete, complete all as specified and directed by Engr-in-Charge.
M&L for Precast reinforced cement concrete, type B-1, 1:2:4 (Using 20mm graded crushed stone aggregate) as in manhole cover set in cement mortar 1:4, compete all as specified and directed.
Excavation over area n exc not exc 1.5 m in depth and getting out in hard/ dense soil, complete all as specified and directed by Engr-in-Charge.
Extra over item here in before for Each addittional 1.5 m depth or part thereof in depth beyound the first 1.5 m depth, complete all as specified and directed by Engr-in-Charge.
M&L for point wiring with PVC insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed for following :-
(a) One light point/one fan point controlled by one switch
(b) One 3 pin 5 amps socket outlet same board with cables 1.5 sqmm size
(c) One 3 pin 5 amps socket outlet independent with cables 1.5 sqmm size
S&F switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed.
S & F in repair socket 2 in 1 , 5Amp flush type complete all as specified and directed.
S & F Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
M&L in repair ceiling rose surface Bakelite 65x50mm two to three terminal complete all as specified and as directed by Engr-in-Charge.
S&F in repair basic all purpose surface and wall mounted LED batten with polycarbonate housing and integreted electronic driver of cap 20 watt, 4 feet long, with all accessories complete all as per specified and as directed by Engr-in-Charge.
S & F in repair LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
Supply and fix in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete.
S&F sheet metal powder coated versatile Double door SPN distribution board, 4 way suitable for MCB's fitted with copper bus bar rated 200amps, neutral link , earth bar and din rail suitable for use on 240 Volt, 50Hz .
M&L in repair for MCB SPN 63 Amp,240V with 10KA breaking capacity of 'C' series in distribution board all as specified and directed.
S&F in repairs to MCB SP 6-32 Amp with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
Supply and fixing in 1100 Volts grade heavy duty cable PVC insulated aluminimum conductor of size 16 Sq mm twin core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, flat or circular all as specified and directed.
Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to galvanized earh lead wire of size 4.0 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified.
M/S SONAM NAMGIAL (BID ID -3157298)
M/S GHULAM HAIDER (BID ID -3158205)
M/S NANCY ENTERPRISES (BID ID -3158264)
M/S SONAM angchok (BID ID -3158210)
M/S TSERING ANGCHOK (BID ID -3157341)
M/S LOBZANG NORBOO (BID ID -3157369)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .