Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹25.1 L+₹91,458.95 (3.78%)Rejected-AOC OPP CCS GARACHARMA PORT BLAIR 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L2 | Rejected-AOC Not L1 | |
| 3 | L3₹25.6 L+₹1.4 L (5.75%)Rejected-AOC ATR MAIN ROAD GARACHARMA II OPP MAHINDRA JADWET SHOWROOM SRI VIJAYA PURAM 744105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L3 | Rejected-AOC Not L1 | |
| 4 | L4₹25.9 L+₹1.7 L (7.07%)Rejected-AOC | L4 | Rejected-AOC Not L1 | |
| 5 | L5₹26.0 L+₹1.8 L (7.44%)Rejected-AOC | L5 | Rejected-AOC Not L1 |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
20 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Brichgunj
GE Brichgunj, Port Blair
SPECIAL REPAIRS TO BLDG NO P- 405 AT PORTHARAPUR UNDER GE BRICHGUNJ PORT BLAIR.
2021_MES_485255_1
GE8170A
Open Tender
Civil Works
Item Rate
180 days
GE Brichgunj
As per tender documents
8 documents required · 8 mandatory
₹500
GE Brichgunj
₹46,000
Yes
26 Nov 2021
30 Oct 2021
22 Nov 2021
30 Oct 2021
20 Nov 2021
13 Nov 2021
30 Oct 2021 - 12 Nov 2021
60 days
Amount
Demolition of brick work built in cement mortar or lime mortar complete of any description all as specified and directed.
M&L precast cement concrete block masonry with PCC solid blocks in 1:3:6 type C1 using 20mm graded stone aggregates, exc. 10cm in width and set in CM 1:4 complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specified complete all as directed.(plinth protection)
M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection, surface finished even and smooth without using extra cement, laid in panels
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing the rubbish off the premises.
M/L 25mm thk PCC 1:2:4 type B-0 using 12.5 mm graded aggregate as in flooring finished fair and even without using extra cement.
M & L for Dark coloured vitrified tiles 8 to 10 mm thick (square/rectangular) polished, area of each tiles n exc. 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed with coloured or white cement to match including screed bed 15mm thick 1:4, complete all as specified and as directed by Engineer-in-Charge.
All as per item no 07 here in before but on vertical surfaces including 10mm thick CM 1:3 as backing coat of dado/Skirting complete all as specified and as directed by Engineer-in-Charge.
M&L non skid ceramic tiles 7 to 10mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm and not exceeding 0.38 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles over 15mm thick screed bed in CM 1:4
All as per item No 09 here in before but on vertical surfaces including 10mm thick CM 1:3 as baking coat of dado/skirting complete all as specified and as directed by Engineer-in-Charge.
M&L for coloured glazed ceramic tiles, (300 x 200mm) x 7mm thick on vertical surfaces set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tile over and including rendering 10mm thick in CM 1:3 complete all as specified and as directed by Engineer-in-Charge.
M & L Chequered cement concrete tiles, with grey cement and pigment 30cm x30cm x20mm thick set, jointed and pointed in neat cement slurrry in floors including 15mm thick screed bed in Cm 1:4 all as specified and directed.
Taking down cement plaster on Brick / Concrete surfaces incl raking out joints, hacking for key scrubbing down with water and Removing Rubbish out side of the MD Land all as directed by Engineer-in-Charge.
M&L Rendering 10mm thick on internal sides wall of Brick / Concrete Surfaces in CM (1:6) finished even & smooth without using extra cement.
M&L Rendering 15mm thick in two coat i.e. 10mm thick under coat in CM 1:6 and 5mm thick finishing coat in CM 1:4 finished even & smooth without using extra cement using 3% of WPC complete as specified and directed by Engineer-in-Charge. Note: supply only WPC shall be measured and paid seperately.
M & L for rendering 5 mm thick in CM 1:3 on for ceiling surfaces, finished even and smooth without using extra cement etc complete as specified and directed by Engineer-in-Charge.
M&L for oil bound distempering two coats over a coat of alkali resistant priming paint including one coat of wall care putty and preparation of new plastered or unplastered surfaces of wall complete all as specified and directed by Engineer - in -Charge.
M & L for Complete removal of existing treatment including preparing old surfaces of walls and applying two coats of oil bound distemper over one coat of primer including a coat of putty all as specified and directed by Engineer - in -Charge.
All as per item no 17 here in before but on ceiling surfaces.
All as per Item No 18 here in before but on ceiling surfaces.
M& L for two coat of weather proof exterior acrylic emulsion paint with anti fungal property over a coat of primer and a coat of external wall putty on newly plastered wall surfaces including preperation of surfaces etc complete all as specified and as directed by Engineer-in-Charge.
Preparation of old external surfaces of walls, Facias, cornices etc and applying two coat of weather proof anti fungal paint one coat of external wall putty on walls all as per manufacturer instruction and as directed by Engineer-in-Charge.
M&L for applying one coat epoxy bonding agent @ 2.6 sqm/lit or as per manufactures instruction to old concrete surfaces of columns, beams and similar structural members complete all as specified and as per directed by Engineer-in-Charge. Make Nitobond EP of Fosroc or equivalent as approved by GE
M&L for spraying curing compound as per manufactures instruction on freshly cast concrete surfaces all as specified. Make : Concure WB white of Fosroc or equivalent as approved by GE
M&L in repairs water proofing treatment to RCC roof by priming the plastered surfaces with a coat of cold applied bituminous primer conforming to IS 2488 @ 0.30 kg/sqm and laying APP modified five layer polymeric membrane of minimum wt. 3.50 kg/sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) laid by torch application as per the manufacturers instructions with side overlap of 100mm & end overlap of 100mm & tucked into the chases on vertical surfaces to a height of 300mm & finally finished with bituminous aluminium paint @ 0.10 kg/sqm complete including taking down existing roof treatment all as specified and as directed.
M&L for 25 mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in padding to roof slab and rendering 15 mm thick in one layers on concrete surface with CM 1:3 using water proofing compound @ 3% by weight of cement finished even fair and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. Note:WPC will be measured and paid separately.
Supply only integral water proofing compound complete all as specified and directed by Engineer-in-Charge.
M&L for providing 100mm thick cement concrete 1:4:8 type D2 using 40mm graded stonne aggregate as in sub base of flooring complete all as specified and directed.
Taking down chowkats or frames exceeding exc 1.5 sq. m but n exc 4 sq. m each (Without taking off shutters & Grill from the frame).
S & F Aluminium anodised (minimum anodisation is 15 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangements etc., complete with standard aluminium sections, complete all as specified and as directed by Engineer-in-charge.(Aluminium section shall be of make Jindal/Hindalco/ Indalco). (Note:- Weight of various Aluminium sections handles and locking arrangements shall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted. Glass panels, prelaminated particle boards, aluminium wire cloth as applicable will be measured and paid separately as supplied only).
Supply only 4 mm thick sheet figured glass and glazing with rubber packing around the glass, in squares exceeding 0.50 sqm in each pane complete all as specified and as directed.
Supply only Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed by Engineer-in-Charge.
Taking down PVC waste ,vent,rain water pipes incl fittings in any position
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,fixed to walls.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,fixed to walls.
S&F 75mm dia PVC (SWR) bend with oval access door.
S&F 110mm dia PVC (SWR) bend with oval access door.
M & L for PCC 1:2:4 type B1 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges
M&L for Bands, straps, supports or stays for rainwater, ventilating pipes,including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles securing of Screwed of ends conforming to Fe-290 Gde-E-165
M & L for removing loose and broken concrete by chiseling / picking etc upto a depth of 80 to 100mm from columns, beams and similar structural members, cutting edges, clearing the dismantled portion with wire brushes etc., to remove dust, dirt and other foreign particles etc., and washing with clean water with pressure including necessary scaffolding and removal of debris to a distance n.exc 50m, complete all as specified and as directed by Engineer-in-Charge.
M&L for non shrink, cementitous micro concrete mixed with 12.5mm graded stone aggregate using Renderoc RG or equivalent by weight (18 Kg Aggregate :25 Kg Renderoc RG) respectively (as per manufatures instruction) laid in average thickness 80 to 100 mm in surface of columns, beams, parapets and similar structural members including use and waste of water tight form work, complete all as specificed and as per directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light ,fan,socket or power) complete (fittings such as switches, ceiling roses, pendants regulators sockets etc to be measured separately) removing materials from site taken as credit and making good the disturbed surfaces all as specified and as directed by Engineer - in -Charge.
M & L for point wiring in and including rigid non metallic PVC conduit medium grade, ISI marked of suitable dia, with 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes & 1.6mm thick duly painted inner & outside for mounting switches, sockets, fan regulator etc with 3mm thick plastic laminated sheet cover with brass screw, cup washer & including PVC insulated & unsheathed stranded copper condutor of 1.5 Sqmm as continuous earth wire complete for One light/fan point point controlled by one switch.
All as per item no 43.00 here in before but for One 5 Amps socket outlet point on independent board controlled by one switch.
All as per Item No. 43 here-in- before but with two single core 4 Sqmm size cables and one 4 Sqmm green colour cable as earth continuity conductor for one switch socket as earth continuity conductor for one switch socket outlet 3 pin 15 Amps on independent board complete all as specified and as directed by Engineer - in -Charge.
M & L Switch flush type single pole, one way, 5 Amps 240 Volts all as specified and directed.
M & L socket outlet, 3 pin, 5 Amps flush type all as specified and directed by Engineer - in -Charge.
M & L Switch socket combination 3 pin 15 Amps and 3 pin 5 Amps flush type, all as specified and directed by Engineer - in -Charge.
M & L ceiling rose 65 X 50 mm , three terminals PVC/Polycarbonate complete all as specified and directed by Engineer - in -Charge.
S&F LED light fitting 20 W compact appearance , simple and versatile in nature makes it as long lasting including taking down of existing fitting all as specified and as directed by Engineer - in -Charge.
M&L Sub main wiring with 2 runs of 4 sq mm size and ONE run of single core 4 Sqmm (green clour as earth coontinuity conductor ) multistranded FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn in and including rigid steel conduit medium grade of suitable dia, conduit fittings and accessories concealed in wall/roof/floor all conforming to IS Specifications (Two single cable run, earth wire and conduit measured as one unit length) including taking down existing wire all as specified and as directed.
S&F SPN distribution board factory made double door flush type all as per IS 8623 made from sheet metal duly powder coated 8 way to be fixed flush with wall complete with all accessories including taking down of existing DB all as specified and directed by Engineer-in-Charge.
S&F MCB SPN 5 to 40 Amp, 240 volts of 10 KA rupturing capacity, C-curve type including taking down of existing DB all as specified and directed by Engineer-in-Charge.
S&F MCB SP 5 to 40 Amp, 240 volts of 10 KA rupturing capacity, B-curve type including taking down of existing DB all as specified and directed by Engineer-in-Charge.
S&F building security light luminaries 25W LED IP 66 made up of pressure die cast aluminium housing with polycarbonate cover and high power LEDs and secondary lenses including GI brackets GI tube of 40mm dia of 2 m length and mounting accessories including taking down of existing light fittings all as specified and directed by Engineer-in-Charge.
S&F landscaping light 7 W pressure die cast powder coated housing with PC diffuser efficient high ouput LED with IP 66 protection including taking down of existing DB all as specified and directed by Engineer-in-Charge.
Supply and lay cable XLPE Insulated screened ,PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductors all as per IS -7098(Part-1 1977) and Part 2- 1985 of following sizes in trench / wall / floor of size 2 core 6 Sqmm through suitable dia PVC pipe all as specified and as directed by Engineer-In-Charge.
Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below normal ground level, connected to galvanized earth lead strip 32x6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel, earth strip protected by means of 40mm bore light grade GI pipe up to LT panel board/DBs all as shown in electrical plate No. 3 of SSR-1991 (Part I) including excavation and earth work in any type of soil, PCC (1:2:4) pit with precast RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 6mm dia MS bars @ 100 mm both ways with lifting hooks made out of 6mm dia MS bars, provision of common salt and charcoal dust in alternate layers around the earth plate, wire mesh funnel with watering pipe 20mm dia light grade complete all as specified and as directed by Engineer - in -Charge.
DEEPAK AGENCIES
RPG AND COMPANY
Govinda Swamy Construction
M/s S U Enterprises
SKV Engineering
USR Transport
CHANDER SEKER ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .