Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 9B DR MARTIN LUTHER KING SARANI WOOD STREET NEAR CAMAC STREET KOLKATA WEST BENGAL 700016 | KOLKATA | WEST BENGAL | 700016 | Admitted-Finance |
| 2 | Admitted-Finance 104 GAYATRI BEHIND MITTAL INDUSTRIAL ESTATE ANDHERI KURLA ROAD ANDHERI E MUMBAI 400059 | MUMBAI | MUMBAI | MAHARASHTRA | 400059 | Admitted-Finance |
| 3 | Rejected-Technical 65 VITHAL CHAMBERS KAZI SYED STREET MASJID BUNDER WEST MUMBAI 400003 MUMBAI CITY MAHARASHTRA 400003 | MUMBAI | MAHARASHTRA | 400003 | Rejected-Technical TECHNICALLY NOT SUITABLE. |
Tender Value
Refer Docs
Closing Date
9 Oct 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HEMANT MUNDE
RCF LTD MUMBAI
ARC FOR SUPPLY OF GLAND PACKING (CRITICAL)
2024_RCFL_826656_1
EARC GLAND PACKING (CRITICAL) 2024
Open Tender
Miscellaneous Goods
Supply
365 days
RCF LTD MUMBAI
AS PER TENDER DOCUMENTS
11 documents required · 11 mandatory
₹0
Exempted
27 May 2025
18 Sept 2024
9 Oct 2024
18 Sept 2024
9 Oct 2024
18 Sept 2024
GLAND PACKING A) TYPE: HIGH GRADE GRAPHITE FIBRE YARN PACKING IMPREGNATED WITH A SPECIAL GRAPHITE MIX, IN INTERLOCK BRAID AND FURTHER REINFORCED WITH INCONEL WIRE. B) SIZE: 9 MM SQ. CROSS-SECTION C) OPERATING CONDITIONS: 1) TEMPERATURE: UPTO 800°C 2) PRESSURE: UPTO 8 BAR 3) pH RANGE: 0-14 D) APPLICATIONS: VALVES HANDLING SUPERHEATED & SATURATED STEAM, HYDROCARBON, SO2/SO3/NOX GASES, AMMONIA, ACID, ALKALIES, STRONG CHEMICALS, OILS & SOLVENTS, BOILER FEED WATER & CONDENSATE , ETC. E) COMPLIANCE STANDARDS (MANDATORY): 1) FIRE TEST STANDARD: API 589 & API 607. 2) FUGITIVE EMMISION TEST: API 622 2ND EDITION / ISO 15848- PART 1/MESC 77/312 / EQUIVALENT F) MAKE & STYLE OF GLAND PACKING: JD JONES (PACMAAN) STYLE ‘NA715’ / JAMES WALKER INMARCO STYLE "100FXI SPECIAL" / JOHN CRANE STYLE G85 IEP / SLADE STYLE "3300W" / TEADIT STYLE "2236" / PILOT GASKET STYLE "7310" / EAGLEBURGMANN STYLE " BuraTAL-FLEX 6070" / GARLOCK STYLE "1303-FEP" ONLY. NOTES: 1) VENDOR SHALL SUBMIT COPY OF FIRE TEST REPORT & FUGITIVE EMISSION TEST REPORT OF THE GLAND PACKINGS ALONG WITH THE SUPPLY. 2) GLAND PACKING SHALL BE PROPERLY PACKED & DELVERED TO RCF. 3) PACKING IS TO BE SUPPLIED IN A CONTINUOUS ROLL OF 3 KGS EACH.
READY CUT GLAND PACKING A) TYPE: EXPANDED PURE GRAPHITE BRAIDED PACKING REINFORCED WITH MULTIPLE INCONNEL / SS WIRE INSIDE EACH YARN AND FURTHER JACKETED WITH HIGH GRADE INCONEL / SS WIRE MESH. B) SIZE (READYCUT): 30 MM OD X 20 MM ID X 5 MM C/S C) OPERATING CONDITIONS: 1) TEMPERATURE: -240 °C TO 650°C 2) PRESSURE: 600 BAR 3) pH RANGE: 0-14 D) APPLICATIONS: VALVE HANDLING SUPERHEATED & SATURATED STEAM, HYDROCARBONS, HYDROGEN, HOT ASH, SOLID CATALYST, DYES & CHEMICALS, FUEL & LUBE OIL, NON OXIDIZING LIQUID & GASES, ETC. E) COMPLIANCE STANDARDS (MANDATORY): 1) FIRE TEST STANDARD: API 589 / API 607. 2) FUGITIVE EMMISION TEST: API 622 2ND EDITION / ISO 15848- PART 1/ MESC 77/312 / EQUIVALENT F) MAKE & STYLE OF GLAND PACKING: JD JONES (PACMAAN) STYLE ‘NA715’ / JAMES WALKER INMARCO STYLE "100FXI SPECIAL" / JOHN CRANE STYLE G85 IEP / SLADE STYLE "3300i" / TEADIT STYLE "2236" / PILOT GASKET STYLE "7310" / EAGLEBURGMANN STYLE " BuraTAL-FLEX 6070" / GARLOCK STYLE "1303-FEP" ONLY. NOTES: 1) VENDOR SHALL SUBMIT COPY OF FIRE TEST REPORT & FUGITIVE EMISSION TEST REPORT OF THE GLAND PACKINGS ALONG WITH THE SUPPLY. 2) GLAND PACKING SHALL BE PROPERLY PACKED & DELIVERED TO RCF. 3) THE PACKING SHALL BE SUPPLIED IN TANGENTIALLY MACHINE CUT AT 45*
READY CUT GLAND PACKING A) TYPE: EXPANDED PURE GRAPHITE BRAIDED PACKING REINFORCED WITH MULTIPLE INCONNEL / SS WIRE INSIDE EACH YARN AND FURTHER JACKETED WITH HIGH GRADE INCONEL / SS WIRE MESH. B) SIZE (READYCUT): 48 MM OD X 32 MM ID X 8 MM C/S C) OPERATING CONDITIONS: 1) TEMPERATURE: -240 °C TO 650°C 2) PRESSURE: 600 BAR 3) pH RANGE: 0-14 D) APPLICATIONS: VALVE HANDLING SUPERHEATED & SATURATED STEAM, HYDROCARBONS, HYDROGEN, HOT ASH, SOLID CATALYST, DYES & CHEMICALS, FUEL & LUBE OIL, NON OXIDIZING LIQUID & GASES, ETC. E) COMPLIANCE STANDARDS (MANDATORY): 1) FIRE TEST STANDARD: API 589 / API 607. 2) FUGITIVE EMMISION TEST: API 622 2ND EDITION / ISO 15848- PART 1/ MESC 77/312 / EQUIVALENT F) MAKE & STYLE OF GLAND PACKING: JD JONES (PACMAAN) STYLE ‘NA715’ / JAMES WALKER INMARCO STYLE "100FXI SPECIAL" / JOHN CRANE STYLE G85 IEP / SLADE STYLE "3300i" / TEADIT STYLE "2236" / PILOT GASKET STYLE "7310" / EAGLEBURGMANN STYLE " BuraTAL-FLEX 6070" / GARLOCK STYLE "1303-FEP" ONLY. NOTES: 1) VENDOR SHALL SUBMIT COPY OF FIRE TEST REPORT & FUGITIVE EMISSION TEST REPORT OF THE GLAND PACKINGS ALONG WITH THE SUPPLY. 2) GLAND PACKING SHALL BE PROPERLY PACKED & DELIVERED TO RCF. 3) THE PACKING SHALL BE SUPPLIED IN TANGENTIALLY MACHINE CUT AT 45*
READY CUT GLAND PACKING A) TYPE: EXPANDED PURE GRAPHITE BRAIDED PACKING REINFORCED WITH MULTIPLE INCONNEL / SS WIRE INSIDE EACH YARN AND FURTHER JACKETED WITH HIGH GRADE INCONEL / SS WIRE MESH. B) SIZE (READYCUT): 60MM OD X 40 MM ID X 10 MM C/S C) OPERATING CONDITIONS: 1) TEMPERATURE: -240 °C TO 650°C 2) PRESSURE: 600 BAR 3) pH RANGE: 0-14 D) APPLICATIONS: VALVE HANDLING SUPERHEATED & SATURATED STEAM, HYDROCARBONS, HYDROGEN, HOT ASH, SOLID CATALYST, DYES & CHEMICALS, FUEL & LUBE OIL, NON OXIDIZING LIQUID & GASES, ETC. E) COMPLIANCE STANDARDS (MANDATORY): 1) FIRE TEST STANDARD: API 589 / API 607. 2) FUGITIVE EMMISION TEST: API 622 2ND EDITION / ISO 15848- PART 1/ MESC 77/312 / EQUIVALENT F) MAKE & STYLE OF GLAND PACKING: JD JONES (PACMAAN) STYLE ‘NA715’ / JAMES WALKER INMARCO STYLE "100FXI SPECIAL" / JOHN CRANE STYLE G85 IEP / SLADE STYLE "3300i" / TEADIT STYLE "2236" / PILOT GASKET STYLE "7310" / EAGLEBURGMANN STYLE " BuraTAL-FLEX 6070" / GARLOCK STYLE "1303-FEP" ONLY. NOTES: 1) VENDOR SHALL SUBMIT COPY OF FIRE TEST REPORT & FUGITIVE EMISSION TEST REPORT OF THE GLAND PACKINGS ALONG WITH THE SUPPLY. 2) GLAND PACKING SHALL BE PROPERLY PACKED & DELIVERED TO RCF. 3) THE PACKING SHALL BE SUPPLIED IN TANGENTIALLY MACHINE CUT AT 45*
READY CUT GLAND PACKING A) TYPE: EXPANDED PURE GRAPHITE BRAIDED PACKING REINFORCED WITH MULTIPLE INCONNEL / SS WIRE INSIDE EACH YARN AND FURTHER JACKETED WITH HIGH GRADE INCONEL / SS WIRE MESH. B) SIZE (READYCUT): 64 MM OD X 44 MM ID X 10 MM C/S C) OPERATING CONDITIONS: 1) TEMPERATURE: -240 °C TO 650°C 2) PRESSURE: 600 BAR 3) pH RANGE: 0-14 D) APPLICATIONS: VALVE HANDLING SUPERHEATED & SATURATED STEAM, HYDROCARBONS, HYDROGEN, HOT ASH, SOLID CATALYST, DYES & CHEMICALS, FUEL & LUBE OIL, NON OXIDIZING LIQUID & GASES, ETC. E) COMPLIANCE STANDARDS (MANDATORY): 1) FIRE TEST STANDARD: API 589 / API 607. 2) FUGITIVE EMMISION TEST: API 622 2ND EDITION / ISO 15848- PART 1/ MESC 77/312 / EQUIVALENT F) MAKE & STYLE OF GLAND PACKING: JD JONES (PACMAAN) STYLE ‘NA715’ / JAMES WALKER INMARCO STYLE "100FXI SPECIAL" / JOHN CRANE STYLE G85 IEP / SLADE STYLE "3300i" / TEADIT STYLE "2236" / PILOT GASKET STYLE "7310" / EAGLEBURGMANN STYLE " BuraTAL-FLEX 6070" / GARLOCK STYLE "1303-FEP" ONLY. NOTES: 1) VENDOR SHALL SUBMIT COPY OF FIRE TEST REPORT & FUGITIVE EMISSION TEST REPORT OF THE GLAND PACKINGS ALONG WITH THE SUPPLY. 2) GLAND PACKING SHALL BE PROPERLY PACKED & DELIVERED TO RCF. 3) THE PACKING SHALL BE SUPPLIED IN TANGENTIALLY MACHINE CUT AT 45*
READY CUT GLAND PACKING A) TYPE: EXPANDED PURE GRAPHITE BRAIDED PACKING REINFORCED WITH MULTIPLE INCONNEL / SS WIRE INSIDE EACH YARN AND FURTHER JACKETED WITH HIGH GRADE INCONEL / SS WIRE MESH. B) SIZE (READYCUT): 68 MM OD X 48 MM ID X 10 MM C/S C) OPERATING CONDITIONS: 1) TEMPERATURE: -240 °C TO 650°C 2) PRESSURE: 600 BAR 3) pH RANGE: 0-14 D) APPLICATIONS: VALVE HANDLING SUPERHEATED & SATURATED STEAM, HYDROCARBONS, HYDROGEN, HOT ASH, SOLID CATALYST, DYES & CHEMICALS, FUEL & LUBE OIL, NON OXIDIZING LIQUID & GASES, ETC. E) COMPLIANCE STANDARDS (MANDATORY): 1) FIRE TEST STANDARD: API 589 / API 607. 2) FUGITIVE EMMISION TEST: API 622 2ND EDITION / ISO 15848- PART 1/ MESC 77/312 / EQUIVALENT F) MAKE & STYLE OF GLAND PACKING: JD JONES (PACMAAN) STYLE ‘NA715’ / JAMES WALKER INMARCO STYLE "100FXI SPECIAL" / JOHN CRANE STYLE G85 IEP / SLADE STYLE "3300i" / TEADIT STYLE "2236" / PILOT GASKET STYLE "7310" / EAGLEBURGMANN STYLE " BuraTAL-FLEX 6070" / GARLOCK STYLE "1303-FEP" ONLY. NOTES: 1) VENDOR SHALL SUBMIT COPY OF FIRE TEST REPORT & FUGITIVE EMISSION TEST REPORT OF THE GLAND PACKINGS ALONG WITH THE SUPPLY. 2) GLAND PACKING SHALL BE PROPERLY PACKED & DELIVERED TO RCF. 3) THE PACKING SHALL BE SUPPLIED IN TANGENTIALLY MACHINE CUT AT 45*
READY CUT GLAND PACKING A) TYPE: EXPANDED PURE GRAPHITE BRAIDED PACKING REINFORCED WITH MULTIPLE INCONNEL / SS WIRE INSIDE EACH YARN AND FURTHER JACKETED WITH HIGH GRADE INCONEL / SS WIRE MESH. B) SIZE (READYCUT): 28 MM OD X 16 MM ID X 6 MM C/S C) OPERATING CONDITIONS: 1) TEMPERATURE: -240 °C TO 650°C 2) PRESSURE: 600 BAR 3) pH RANGE: 0-14 D) APPLICATIONS: VALVE HANDLING SUPERHEATED & SATURATED STEAM, HYDROCARBONS, HYDROGEN, HOT ASH, SOLID CATALYST, DYES & CHEMICALS, FUEL & LUBE OIL, NON OXIDIZING LIQUID & GASES, ETC. E) COMPLIANCE STANDARDS (MANDATORY): 1) FIRE TEST STANDARD: API 589 / API 607. 2) FUGITIVE EMMISION TEST: API 622 2ND EDITION / ISO 15848- PART 1/ MESC 77/312 / EQUIVALENT F) MAKE & STYLE OF GLAND PACKING: JD JONES (PACMAAN) STYLE ‘NA715’ / JAMES WALKER INMARCO STYLE "100FXI SPECIAL" / JOHN CRANE STYLE G85 IEP / SLADE STYLE "3300i" / TEADIT STYLE "2236" / PILOT GASKET STYLE "7310" / EAGLEBURGMANN STYLE " BuraTAL-FLEX 6070" / GARLOCK STYLE "1303-FEP" ONLY. NOTES: 1) VENDOR SHALL SUBMIT COPY OF FIRE TEST REPORT & FUGITIVE EMISSION TEST REPORT OF THE GLAND PACKINGS ALONG WITH THE SUPPLY. 2) GLAND PACKING SHALL BE PROPERLY PACKED & DELIVERED TO RCF. 3) THE PACKING SHALL BE SUPPLIED IN TANGENTIALLY MACHINE CUT AT 45*
GLAND PACKING A) TYPE: EXPANDED PURE GRAPHITE BRAIDED PACKING REINFORCED WITH MULTIPLE INCONNEL / SS WIRE INSIDE EACH YARN AND FURTHER JACKETED WITH HIGH GRADE INCONEL / SS WIRE MESH. B) SIZE: 4 MM SQ. CROSS-SECTION C) OPERATING CONDITIONS: 1) TEMPERATURE: -240 °C TO 650°C 2) PRESSURE: 600 BAR 3) pH RANGE: 0-14 D) APPLICATIONS: VALVE HANDLING SUPERHEATED & SATURATED STEAM, HYDROCARBONS, HYDROGEN, HOT ASH, SOLID CATALYST, DYES & CHEMICALS, FUEL & LUBE OIL, NON OXIDIZING LIQUID & GASES, ETC. E) COMPLIANCE STANDARDS (MANDATORY): 1) FIRE TEST STANDARD: API 589 / API 607. 2) FUGITIVE EMMISION TEST: API 622 2ND EDITION / ISO 15848- PART 1/ MESC 77/312 / EQUIVALENT F) MAKE & STYLE OF GLAND PACKING: JD JONES (PACMAAN) STYLE ‘NA715’ / JAMES WALKER INMARCO STYLE "100FXI SPECIAL" / JOHN CRANE STYLE G85 IEP / SLADE STYLE "3300i" / TEADIT STYLE "2236" / PILOT GASKET STYLE "7310" / EAGLEBURGMANN STYLE " BuraTAL-FLEX 6070" / GARLOCK STYLE "1303-FEP" ONLY. NOTES: 1) VENDOR SHALL SUBMIT COPY OF FIRE TEST REPORT & FUGITIVE EMISSION TEST REPORT OF THE GLAND PACKINGS ALONG WITH THE SUPPLY. 2) GLAND PACKING SHALL BE PROPERLY PACKED & DELIVERED TO RCF. 3) THE PACKINGS SHALL BE SUPPLIED IN 1 KG PACK.
GLAND PACKING A) TYPE: EXPANDED PURE GRAPHITE BRAIDED PACKING REINFORCED WITH MULTIPLE INCONNEL / SS WIRE INSIDE EACH YARN AND FURTHER JACKETED WITH HIGH GRADE INCONEL / SS WIRE MESH. B) SIZE: 6 MM SQ. CROSS-SECTION C) OPERATING CONDITIONS: 1) TEMPERATURE: -240 °C TO 650°C 2) PRESSURE: 600 BAR 3) pH RANGE: 0-14 D) APPLICATIONS: VALVE HANDLING SUPERHEATED & SATURATED STEAM, HYDROCARBONS, HYDROGEN,HOT ASH, SOLID CATALYST, DYES & CHEMICALS, FUEL & LUBE OIL, NONOXIDIZING LIQUID & GASES, ETC. E) COMPLIANCE STANDARDS (MANDATORY): 1) FIRE TEST STANDARD: API 589 / API 607. 2) FUGITIVE EMMISION TEST: API 622 2ND EDITION / ISO 15848- PART 1/MESC 77/312 / EQUIVALENT F) MAKE & STYLE OF GLAND PACKING: JD JONES (PACMAAN) STYLE ‘NA715’ / JAMES WALKER INMARCO STYLE "100FXISPECIAL" / JOHN CRANE STYLE G85 IEP / SLADE STYLE "3300i" / TEADIT STYLE"2236" / PILOT GASKET STYLE "7310" / EAGLEBURGMANN STYLE " BuraTAL-FLEX6070" / GARLOCK STYLE "1303-FEP" ONLY. NOTES: 1) VENDOR SHALL SUBMIT COPY OF FIRE TEST REPORT & FUGITIVE EMISSION TEST REPORT OF THE GLAND PACKINGS ALONG WITH THE SUPPLY. 2) GLAND PACKING SHALL BE PROPERLY PACKED & DELIVERED TO RCF. 3) THE PACKINGS SHALL BE SUPPLIED IN 1 KG PACK.
GLAND PACKING A) TYPE: EXPANDED PURE GRAPHITE BRAIDED PACKING REINFORCED WITH MULTIPLE INCONNEL / SS WIRE INSIDE EACH YARN AND FURTHER JACKETED WITH HIGH GRADE INCONEL / SS WIRE MESH. B) SIZE: 8 MM SQ. CROSS-SECTION C) OPERATING CONDITIONS: 1) TEMPERATURE: -240 °C TO 650°C 2) PRESSURE: 600 BAR 3) pH RANGE: 0-14 D) APPLICATIONS: VALVE HANDLING SUPERHEATED & SATURATED STEAM, HYDROCARBONS, HYDROGEN,HOT ASH, SOLID CATALYST, DYES & CHEMICALS, FUEL & LUBE OIL, NONOXIDIZING LIQUID & GASES, ETC. E) COMPLIANCE STANDARDS (MANDATORY): 1) FIRE TEST STANDARD: API 589 / API 607. 2) FUGITIVE EMMISION TEST: API 622 2ND EDITION / ISO 15848- PART 1/MESC 77/312 / EQUIVALENT F) MAKE & STYLE OF GLAND PACKING: JD JONES (PACMAAN) STYLE ‘NA715’ / JAMES WALKER INMARCO STYLE "100FXISPECIAL" / JOHN CRANE STYLE G85 IEP / SLADE STYLE "3300i" / TEADIT STYLE"2236" / PILOT GASKET STYLE "7310" / EAGLEBURGMANN STYLE " BuraTAL-FLEX6070" / GARLOCK STYLE "1303-FEP" ONLY. NOTES: 1) VENDOR SHALL SUBMIT COPY OF FIRE TEST REPORT & FUGITIVE EMISSION TEST REPORT OF THE GLAND PACKINGS ALONG WITH THE SUPPLY. 2) GLAND PACKING SHALL BE PROPERLY PACKED & DELIVERED TO RCF. 3) THE PACKINGS SHALL BE SUPPLIED IN 1 KG PACK.
GLAND PACKING A) TYPE: EXPANDED PURE GRAPHITE BRAIDED PACKING REINFORCED WITH MULTIPLE INCONNEL / SS WIRE INSIDE EACH YARN AND FURTHER JACKETED WITH HIGH GRADE INCONEL / SS WIRE MESH. B) SIZE: 10 MM SQ. CROSS-SECTION C) OPERATING CONDITIONS: 1) TEMPERATURE: -240 °C TO 650°C 2) PRESSURE: 600 BAR 3) pH RANGE: 0-14 D) APPLICATIONS: VALVE HANDLING SUPERHEATED & SATURATED STEAM, HYDROCARBONS, HYDROGEN,HOT ASH, SOLID CATALYST, DYES & CHEMICALS, FUEL & LUBE OIL, NONOXIDIZING LIQUID & GASES, ETC. E) COMPLIANCE STANDARDS (MANDATORY): 1) FIRE TEST STANDARD: API 589 / API 607. 2) FUGITIVE EMMISION TEST: API 622 2ND EDITION / ISO 15848- PART 1/ MESC 77/312 / EQUIVALENT F) MAKE & STYLE OF GLAND PACKING: JD JONES (PACMAAN) STYLE ‘NA715’ / JAMES WALKER INMARCO STYLE "100FXI SPECIAL" / JOHN CRANE STYLE G85 IEP / SLADE STYLE "3300i" / TEADIT STYLE"2236" / PILOT GASKET STYLE "7310" / EAGLEBURGMANN STYLE " BuraTAL-FLEX6070" / GARLOCK STYLE "1303-FEP" ONLY. NOTES: 1) VENDOR SHALL SUBMIT COPY OF FIRE TEST REPORT & FUGITIVE EMISSION TEST REPORT OF THE GLAND PACKINGS ALONG WITH THE SUPPLY. 2) GLAND PACKING SHALL BE PROPERLY PACKED & DELIVERED TO RCF. 3) THE PACKINGS SHALL BE SUPPLIED IN 1 KG PACK
GLAND PACKING A) TYPE: EXPANDED PURE GRAPHITE BRAIDED PACKING REINFORCED WITH MULTIPLE INCONNEL / SS WIRE INSIDE EACH YARN AND FURTHER JACKETED WITH HIGH GRADE INCONEL / SS WIRE MESH. B) SIZE: 12 MM SQ. CROSS-SECTION C) OPERATING CONDITIONS: 1) TEMPERATURE: -240 °C TO 650°C 2) PRESSURE: 600 BAR 3) pH RANGE: 0-14 D) APPLICATIONS: VALVE HANDLING SUPERHEATED & SATURATED STEAM, HYDROCARBONS, HYDROGEN, HOT ASH, SOLID CATALYST, DYES & CHEMICALS, FUEL & LUBE OIL, NON OXIDIZING LIQUID & GASES, ETC. E) COMPLIANCE STANDARDS (MANDATORY): 1) FIRE TEST STANDARD: API 589 / API 607. 2) FUGITIVE EMMISION TEST: API 622 2ND EDITION / ISO 15848- PART 1/ MESC 77/312 / EQUIVALENT F) MAKE & STYLE OF GLAND PACKING: JD JONES (PACMAAN) STYLE ‘NA715’ / JAMES WALKER INMARCO STYLE "100FXI SPECIAL" / JOHN CRANE STYLE G85 IEP / SLADE STYLE "3300i" / TEADIT STYLE "2236" / PILOT GASKET STYLE "7310" / EAGLEBURGMANN STYLE " BuraTAL-FLEX 6070" / GARLOCK STYLE "1303-FEP" ONLY. NOTES: 1) VENDOR SHALL SUBMIT COPY OF FIRE TEST REPORT & FUGITIVE EMISSION TEST REPORT OF THE GLAND PACKINGS ALONG WITH THE SUPPLY. 2) GLAND PACKING SHALL BE PROPERLY PACKED & DELIVERED TO RCF. 3) THE PACKINGS SHALL BE SUPPLIED IN 1 KG PACK.
GLAND PACKING A) TYPE: EXPANDED PURE GRAPHITE BRAIDED PACKING REINFORCED WITH MULTIPLE INCONNEL / SS WIRE INSIDE EACH YARN AND FURTHER JACKETED WITH HIGH GRADE INCONEL / SS WIRE MESH. B) SIZE: 16 MM SQ. CROSS-SECTION C) OPERATING CONDITIONS: 1) TEMPERATURE: -240 °C TO 650°C 2) PRESSURE: 600 BAR 3) pH RANGE: 0-14 D) APPLICATIONS: VALVE HANDLING SUPERHEATED & SATURATED STEAM, HYDROCARBONS, HYDROGEN, HOT ASH, SOLID CATALYST, DYES & CHEMICALS, FUEL & LUBE OIL, NON OXIDIZING LIQUID & GASES, ETC. E) COMPLIANCE STANDARDS (MANDATORY): 1) FIRE TEST STANDARD: API 589 / API 607. 2) FUGITIVE EMMISION TEST: API 622 2ND EDITION / ISO 15848- PART 1/ MESC 77/312 / EQUIVALENT F) MAKE & STYLE OF GLAND PACKING: JD JONES (PACMAAN) STYLE ‘NA715’ / JAMES WALKER INMARCO STYLE "100FXI SPECIAL" / JOHN CRANE STYLE G85 IEP / SLADE STYLE "3300i" / TEADIT STYLE "2236" / PILOT GASKET STYLE "7310" / EAGLEBURGMANN STYLE " BuraTAL-FLEX 6070" / GARLOCK STYLE "1303-FEP" ONLY. NOTES: 1) VENDOR SHALL SUBMIT COPY OF FIRE TEST REPORT & FUGITIVE EMISSION TEST REPORT OF THE GLAND PACKINGS ALONG WITH THE SUPPLY. 2) GLAND PACKING SHALL BE PROPERLY PACKED & DELIVERED TO RCF. 3) THE PACKINGS SHALL BE SUPPLIED IN 1 KG PACK.
GLAND PACKING A) TYPE: EXPANDED PURE GRAPHITE BRAIDED PACKING REINFORCED WITH MULTIPLE INCONNEL / SS WIRE INSIDE EACH YARN AND FURTHER JACKETED WITH HIGH GRADE INCONEL / SS WIRE MESH. B) SIZE: 3 MM SQ. CROSS-SECTION C) OPERATING CONDITIONS: 1) TEMPERATURE: -240 °C TO 650°C 2) PRESSURE: 600 BAR 3) pH RANGE: 0-14 D) APPLICATIONS: VALVE HANDLING SUPERHEATED & SATURATED STEAM, HYDROCARBONS, HYDROGEN, HOT ASH, SOLID CATALYST, DYES & CHEMICALS, FUEL & LUBE OIL, NON OXIDIZING LIQUID & GASES, ETC. E) COMPLIANCE STANDARDS (MANDATORY): 1) FIRE TEST STANDARD: API 589 / API 607. 2) FUGITIVE EMMISION TEST: API 622 2ND EDITION / ISO 15848- PART 1/ MESC 77/312 / EQUIVALENT F) MAKE & STYLE OF GLAND PACKING: JD JONES (PACMAAN) STYLE ‘NA715’ / JAMES WALKER INMARCO STYLE "100FXI SPECIAL" / JOHN CRANE STYLE G85 IEP / SLADE STYLE "3300i" / TEADIT STYLE "2236" / PILOT GASKET STYLE "7310" / EAGLEBURGMANN STYLE " BuraTAL-FLEX 6070" / GARLOCK STYLE "1303-FEP" ONLY. NOTES: 1) VENDOR SHALL SUBMIT COPY OF FIRE TEST REPORT & FUGITIVE EMISSION TEST REPORT OF THE GLAND PACKINGS ALONG WITH THE SUPPLY. 2) GLAND PACKING SHALL BE PROPERLY PACKED & DELIVERED TO RCF. 3) THE PACKINGS SHALL BE SUPPLIED IN 1 KG PACK.
GLAND PACKING A) TYPE: EXPANDED PURE GRAPHITE BRAIDED PACKING REINFORCED WITH MULTIPLE INCONNEL / SS WIRE INSIDE EACH YARN AND FURTHER JACKETED WITH HIGH GRADE INCONEL / SS WIRE MESH. B) SIZE: 5 MM SQ. CROSS-SECTION C) OPERATING CONDITIONS: 1) TEMPERATURE: -240 °C TO 650°C 2) PRESSURE: 600 BAR 3) pH RANGE: 0-14 D) APPLICATIONS: VALVE HANDLING SUPERHEATED & SATURATED STEAM, HYDROCARBONS, HYDROGEN, HOT ASH, SOLID CATALYST, DYES & CHEMICALS, FUEL & LUBE OIL, NON OXIDIZING LIQUID & GASES, ETC. E) COMPLIANCE STANDARDS (MANDATORY): 1) FIRE TEST STANDARD: API 589 / API 607. 2) FUGITIVE EMMISION TEST: API 622 2ND EDITION / ISO 15848- PART 1/ MESC 77/312 / EQUIVALENT F) MAKE & STYLE OF GLAND PACKING: JD JONES (PACMAAN) STYLE ‘NA715’ / JAMES WALKER INMARCO STYLE "100FXI SPECIAL" / JOHN CRANE STYLE G85 IEP / SLADE STYLE "3300i" / TEADIT STYLE "2236" / PILOT GASKET STYLE "7310" / EAGLEBURGMANN STYLE " BuraTAL-FLEX 6070" / GARLOCK STYLE "1303-FEP" ONLY. NOTES: 1) VENDOR SHALL SUBMIT COPY OF FIRE TEST REPORT & FUGITIVE EMISSION TEST REPORT OF THE GLAND PACKINGS ALONG WITH THE SUPPLY. 2) GLAND PACKING SHALL BE PROPERLY PACKED & DELIVERED TO RCF. 3) THE PACKINGS SHALL BE SUPPLIED IN 1 KG PACK.
GLAND PACKING A) TYPE: HIGH GRADE GRAPHITE FIBRE YARN PACKING IMPREGNATED WITH A SPECIAL GRAPHITE MIX, IN INTERLOCK BRAID AND FURTHER REINFORCED WITH INCONEL WIRE. B) SIZE: 6 MM SQ. CROSS-SECTION C) OPERATING CONDITIONS: 1) TEMPERATURE: UPTO 800°C 2) PRESSURE: UPTO 8 BAR 3) pH RANGE: 0-14 D) APPLICATIONS: VALVES HANDLING SUPERHEATED & SATURATED STEAM, HYDROCARBON, SO2/SO3/NOX GASES, AMMONIA, ACID, ALKALIES, STRONG CHEMICALS, OILS & SOLVENTS, BOILER FEED WATER & CONDENSATE , ETC. E) COMPLIANCE STANDARDS (MANDATORY): 1) FIRE TEST STANDARD: API 589 & API 607. 2) FUGITIVE EMMISION TEST: API 622 2ND EDITION / ISO 15848- PART 1/ MESC 77/312 / EQUIVALENT F) MAKE & STYLE OF GLAND PACKING: JD JONES (PACMAAN) STYLE ‘NA715’ / JAMES WALKER INMARCO STYLE "100FXI SPECIAL" / JOHN CRANE STYLE G85 IEP / SLADE STYLE "3300W" / TEADIT STYLE "2236" / PILOT GASKET STYLE "7310" / EAGLEBURGMANN STYLE " BuraTAL-FLEX 6070" / GARLOCK STYLE "1303-FEP" ONLY. NOTES: 1) VENDOR SHALL SUBMIT COPY OF FIRE TEST REPORT & FUGITIVE EMISSION TEST REPORT OF THE GLAND PACKINGS ALONG WITH THE SUPPLY. 2) GLAND PACKING SHALL BE PROPERLY PACKED & DELVERED TO RCF. 3) PACKING IS TO BE SUPPLIED IN A CONTINUOUS ROLL OF 3 KGS EACH.
GLAND PACKING A) TYPE: HIGH GRADE GRAPHITE FIBRE YARN PACKING IMPREGNATED WITH A SPECIAL GRAPHITE MIX, IN INTERLOCK BRAID AND FURTHER REINFORCED WITH INCONEL WIRE. B) SIZE: 12 MM SQ. CROSS-SECTION C) OPERATING CONDITIONS: 1) TEMPERATURE: UPTO 800°C 2) PRESSURE: UPTO 8 BAR 3) pH RANGE: 0-14 D) APPLICATIONS: VALVES HANDLING SUPERHEATED & SATURATED STEAM, HYDROCARBON, SO2/SO3/NOX GASES, AMMONIA, ACID, ALKALIES, STRONG CHEMICALS, OILS & SOLVENTS, BOILER FEED WATER & CONDENSATE , ETC. E) COMPLIANCE STANDARDS (MANDATORY): 1) FIRE TEST STANDARD: API 589 & API 607. 2) FUGITIVE EMMISION TEST: API 622 2ND EDITION / ISO 15848- PART 1/MESC 77/312 / EQUIVALENT F) MAKE & STYLE OF GLAND PACKING: JD JONES (PACMAAN) STYLE ‘NA715’ / JAMES WALKER INMARCO STYLE "100FXI SPECIAL" / JOHN CRANE STYLE G85 IEP / SLADE STYLE "3300W" / TEADIT STYLE "2236" / PILOT GASKET STYLE "7310" / EAGLEBURGMANN STYLE " BuraTAL-FLEX 6070" / GARLOCK STYLE "1303-FEP" ONLY. NOTES: 1) VENDOR SHALL SUBMIT COPY OF FIRE TEST REPORT & FUGITIVE EMISSION TEST REPORT OF THE GLAND PACKINGS ALONG WITH THE SUPPLY. 2) GLAND PACKING SHALL BE PROPERLY PACKED & DELVERED TO RCF.
JAMES WALKER INMARCO INDUSTRIES PRIVATE LIMITED (BID ID -3101182)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .