Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance UDHAMPUR | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹52,300
Closing Date
18 Jul 2025, 3:00 pmClosed
Executive engineer
Executive Engineer Electric Division Udhampur
creation OF Substation ,LT Line HT line
2025_PDD_279887_1
ED/UDH/08 OF 2025-26 Dated 24-6-2025
Open Tender
Electrical Works
Turn-key
90 days
in district Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer,ED Udhampur JPDCL
₹52,300
31 Jul 2025
26 Jun 2025
19 Jul 2025
26 Jun 2025
18 Jul 2025
26 Jun 2025
26 Jun 2025 - 14 Jul 2025
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of 11KV line on 9 mtr Long ST with 30mmsq ACSR Weasel Conductor for Creation of 25 KVA Sub station atW.No. 04 Mohalla Pallian Pyt. Kanah Tehsil Ramnagar
9 mtr. Long ST Poles(ST-410 SP33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
30mm² ACSR Weasel Conductor
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Painting of 9 mtr ST poles with two coats of Aluminium paint.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Creation of 25 KVA Sub station atW.No. 04 Mohalla Pallian Pyt. Kanah Tehsil Ramnagar
11/0.433kV, 3-phase Distribution Transformers 25 KVA Aluminium wound distribution transformer of latest energy efficiency level 2 newISI 1180 PART I 2014 as per latest upto date amendment
Gapless surge Arestor, 9 kv, 10 KA , LA with polymer housing stn. Type
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
11 KV Horn gap fuse set 3 phase 200 A
70mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
9 mtr. Long ST pole (ST-410 SP33)
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm
GI Channel /Angle/flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
LT Fuse Switch made of angle iron 50x50x6 with Aluminium bus bar strip 50x6 mm fixed on busbar insulator including clamps for fixing of switch
Painting of 9 mtr ST poles with two coats of Aluminium paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of LT line on 8 mtr Long ST with 30mmsq ACSR Weasel Conductor for Creation of 25 KVA Sub station atW.No. 04 Mohalla Pallian Pyt. Kanah Tehsil Ramnagar
8 mtr. Long ST poles (ST 410 SP 15)
GI M Clamps for shackle insulator
30mm² ACSR weasel Conductor
Galvanized Nuts and Bolts.
Shackle insulator
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of 11KV line on 9 mtr Long ST with 30mmsq ACSR Weasel Conductor for Creation of 25 KVA Sub station atW.No. 01 Mohalla patiode Pyt.Pinger pingal Mandir
9 mtr. Long ST Poles(ST 410 SP33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
30mm² ACSR Weasel Conductor
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Painting of 9 mtr ST poles with two coats of Aluminium paint.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Creation of 25 KVA Sub station at W.No. 01 Mohalla patiode Pyt.Pinger pingal Mandir
11/0.433kV, 3-phase Distribution Transformers 25 KVA Aluminium wound distribution transformer of latest energy efficiency level 2 newISI 1180 PART I as per latest upto date amendment
Gapless surge Arestor, 9 kv, 10 KA , LA with polymer housing stn. Type
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
11 KV Horn gap fuse set 3 phase 200 A
70mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
9 mtr. Long ST pole (ST-410 SP33)
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm
GI Channel /Angle/flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
LT Fuse Switch made of angle iron 50x50x6 with Aluminium bus bar strip 50x6 mm fixed on busbar insulator including clamps for fixing of switch
Painting of 9 mtr ST poles with two coats of Aluminium paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection/ insertion of poles in longer Spans at atW.No. 01 Mohalla patiode Pyt.Pinger pingal Mandir
8 mtr. Long ST poles (ST 410 SP 15)
GI M Clamps for shackle insulator
30mm² ACSR weasel Conductor
Galvanized Nuts and Bolts.
Shackle insualtor
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection/ insertion of poles in longer Spans at at Dhalper Villagew.no 1 Mohalla Baluni
8 mtr. Long ST poles (ST 410 SP 15)
GI M Clamps for shackle insulator
30mm² ACSR weasel Conductor
Galvanized Nuts and Bolts.
Shackle insualtor
M/S JAI DURGA ELECTRICAL CONTRACTORS (BID ID -2411441)
MAHAKALESHWER DEVIKA ELECTRICAL (BID ID -2403849)
VEENA CONSTRUCTION CO. (BID ID -2402434)
M/S S S CONSTRUCTIONS (BID ID -2411501)
Amour engineering group (BID ID -2398400)
M/S SINGH ELECTRICALS (BID ID -2410932)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .