(I) "Augmentation of infrastructure facilities of DEMU maintenance shed, Sahibganj." (II) Electrical work in c/w "Improvement of Bridge acting as subway beside LC no 19/spl at Km 176/13-14 in BHW stn limit for closure of this LC."
EL-MLDT-E-TENDER-441
EL-MLDT-E-TENDER-441
Open
6 Months
Sahebganj, Jharkhand
₹0
₹65,800
24 Jun 2026
24 Jun 2026
2 Jul 2026
Km 176/13-14 in BHW stn limit for closure of this LC."
Item- 1 Please see in item break up
S No. Item Description of Item Unit Qty Rate Amount
1 1 Supply, fixing and commissioning of 3 inch UPVC Metre 200.00 43.55 8710.00
pipe with T-joint, Elbow joints, Ball valve, etc.
other necessary accessories for Water suction
2 2 Supply and commissioning of 3 inch PVC foot Numbers 2.00 143.07 286.14
3 3 Supply of Premium Quality 3 Inch (75 mm) PVC Metre 10.00 310.00 3100.00
4 4 Supply of LDPE 3 inch (7.62 cm) Lapeta Pipe for Foot 30.00 6.42 192.60
delivery pupose
5 5 Supply of Hose Clamp 3 inch Stainless Steel Set 6.00 95.00 570.00
6 6 Supply, fixing and connection of 3 HP single Set 2.00 30423.00 60846.00
phase Sewage submersible pump.
7 7 Supply, fixing , connection and testing of 3 HP Set 2.00 4153.99 8307.98
8 8 Supply and fixing of WIRELESS PUMP Numbers 2.00 31860.00 63720.00
CONTROLLER 1000GSM 1) Supply of controller for
operation status with Installation & Testing for
pump control motor set. 2) The available voltage
at the site | Pump Load(current) 3) Motor ON/OFF
Status with real-time 4) Power ON/OFF status as
feedback to customers through app. 5) The pump
can be operated from anywhere through mobile.
6) In-built Delay on Timer, Cyclic Timer, RTC
Timer, Maximum Run Timer, water level sensor 7)
Adjustable Voltage & Current Settings. User
Programmable Timer Settings. 8) LCD Display
Indication. 9) Interface Unit 10) 2year of GSM SIM
maintenance charge
9 9 Supply, fixing and connection of 60W highbay Set 40.00 5888.61 235544.40
light (40V-70V AC)
10 10 Wiring of light/lamp/Fan/Exhaust points through Numbers 12.00 313.11 3757.32
PVC casing & capping.
11 11 Extra cost for concealed wiring for light Numbers 12.00 77.09 925.08
/fan/exhaust/wall fan point
12 12 Supply, fixing & connection of ceiling rose (6A) for Numbers 40.00 29.71 1188.40
light/fan/exhaust/wall fan point
13 13 Wiring of sub-main line 4 sq mm Phase & neutral Metre 400.00 152.21 60884.00
(2 Nos copper wire) with ECC of 1no. 2.5 sq mm,
PVC insulated single core, M/Strand copper wire
as per General specification of IE rule.
neutral (2 Nos copper wire) with ECC of 1no. 1.5
sq.mm, PVC insulated single core, M/Strand
copper wire as per General specification of IE rule
15 15 Wiring of main line 6 sq mm Phase & neutral (2 Metre 50.00 160.11 8005.50
Nos copper wire) with ECC of 1no. 4 sq mm
(minimum), PVC insulated single core, M/Strand
copper wire as per General specification of IE
16 16 Extra cost for concealed of Main/sub main Metre 850.00 43.97 37374.50
line1.5/4/6 sq mm.
MALDA DIVISION-ELECTRICAL/EASTERN RLY
17 17 Supply, fixing and connection of LED 16W fittings Numbers 30.00 3376.27 101288.10
suitable for Pit/under Cat walk light operating
voltage (40- 72V) AC as per specification.
18 18 Supply and fixing of SS cage of size min (15.5" x Set 30.00 273.13 8193.90
6" x 4") or as per site made with SS angle frame
and SS wire mesh for covering the pit light
19 19 Supply of power supply unit 3KVA for pit light as Set 2.00 17850.73 35701.46
per specification
20 20 Fixing and connection of power supply unit Set 2.00 191.78 383.56
(Louvolite transformer) at site location.
21 21 Supply and fixing of enclosure of size min (L X W Set 2.00 6110.53 12221.06
X D/2 ' x 3' X 2.5') MS original sheet encloser of
14 SWG with inside & outside anticorrosive ISI
brand paint and hinged door to be kept on min 3
feet height tool made with MS angle (76x6) mm
placing of power supply unit (Louvolite
22 22 Supply & fixing of LED tube light fitting complete Set 4.00 352.02 1408.08
set 20W (Aluminium housing) System efficacy
23 23 Supply, fixing & connection of LED 9W lamp with Set 4.00 147.32 589.28
suitable angular batten holder with metal ring.
24 24 Supply, replacement/new provision and fixing of Set 2.00 3248.84 6497.68
BLDC energy efficient (5 star rated) ceiling fan
1200 mm sweep wattage-max 35W with air
delivery: min 230 cu/meter/minute (with remote)
25 25 Supply, fixing & commissioning of 5 Meters length Set 12.00 11456.51 137478.12
GI octagonal pole with all accessories and
necessary RCC foundation.
26 26 Supply, fixing and connection of LED street light Numbers 18.00 4105.61 73900.98
45W (48V-70V AC)
27 27 Supply and fixing of G.I. Pipe heavy gauge size Set 4.00 165.63 662.52
1/1.25 inch dia 2.5 ft. long bended as per site
requirement including 2 sets of M.S clamps, nuts
& bolts, wiring with flexible PVC Cu. cable through
28 28 Wiring of 5 pin 5A, plug point (as per IS 694:1990) Numbers 4.00 193.53 774.12
& ECC of size 18 SWG copper wire including
supply of 5 pin plug.
29 29 Surface wiring of 5/15A combined plug points Numbers 4.00 226.30 905.20
through PVC casing & capping PVC insulated,
single core, multi stranded, unsheathed, copper
conductor of size 4 mm sq (as per IS 694:1990)
&ECC of size 16 SWG copper wire including
supply of all materials with plug socket, switch,
30 30 Extra cost for concealed of 5 pin 5A/5-15A plug Numbers 8.00 41.86 334.88
31 31 Supply, fixing & connection of SPN, 2 way MCB Numbers 4.00 361.44 1445.76
sheet steel 18 SWG original enclosure, (18-20
micron) powder painted.
32 32 Supply, fixing & connection of SP MCB of 16 A on Numbers 4.00 157.92 631.68
MCB Distribution Board.
33 33 Supply, fixing & connection of SPN 6 way (No of Numbers 2.00 4813.59 9627.18
module 6+2) MCB sheet steel Distribution Board
with metal door including i) Supply of 4 nos SP
MCB (6-32A) ii) 01 no RCCB 32/40A (100mA)
including all wiring.
35 35 Supply, fixing, and connection of Bus-bar Set 1.00 4546.40 4546.40
Chamber 4 way of Cap-63A wall mounted
including connection of LT cable with proper lugs
and cable gland etc.
36 36 Supply, installation, commissioning & testing of Set 2.00 2655.37 5310.74
earthing as per IS:3043 or latest amendment.
MALDA DIVISION-ELECTRICAL/EASTERN RLY
latest. (Cable will be supplied by Railway)
38 38 Cable laying through pole/wall/floor as per site Metre 200.00 39.11 7822.00
requirement as per IS-1255, 1983 or latest.
(Cable will be supplied by Railway)
39 39 Supply and laying of 3" dia medium gauge ISI Metre 100.00 684.32 68432.00
brand heavy duty G.I pipe for LT cable Track
crossing and road crossing and for rising of cable.
(Cable will be supplied by Railway)
40 40 Dismantling of wiring including fittings and street Man- 2.00 1403.00 2806.00
41 41 Dismantling of Rail/Tubular pole/Octagonal pole Numbers 4.00 627.98 2511.92
complete with foundation, MS bracket, nut bolts,
ACSR etc. and all released materials shall be
carried out and handed over to Sr. S.E.E(G) MLDT
store with proper acknowledgement.
42 42 Supply, fixing and connection of Timer consisting Set 1.00 7938.41 7938.41
of below materials with complete wiring- 1) MCB
32A 4P -01 set 2) Contactor 32A 3P -01 set 3)
Digital Time Switch-01 set 4) 2 way centre off
change over switch 25A- 01 set with all wiring
connection of suitable size and 14 SWG MS
original sheet enclosure of suitable size with
hinged door opening.
Item Breakup - A-"Augmentation of infrastructure facilities of DEMU maintenance shed, Sahibganj."
Wiring of (modular).
Extra cost for concealed /fan/exhaust/wall fan point. MALDA DIVISION-ELECTRICAL/EASTERN RLY
Wiring of sub-main line 2.5 sq mm Phase & Metre neutral (2 Nos copper wire) with ECC of 1no. 1.5 sq.mm, PVC insulated single core, M/Strand copper wire as per General specification of IE rule
Wiring of sub-main line 4 sq mm Phase & neutral Metre (2 Nos copper wire) with ECC of 1no. 2.5 sq mm, PVC insulated single core, M/Strand copper wire as per General specification of IE rule.
Wiring of sub-main line 6 sq mm Phase & neutral Metre (2 Nos copper wire) with ECC of 1no. 4 sq mm (minimum), PVC insulated single core, M/Strand copper wire as per General specification of IE rule.
Wiring of Main line 3 Phase & neutral (4 wire) Metre copper conductor of size 10 mm sq with ECC as per General specification of IE rule
Extra cost for concealed of Main/sub main Metre line1.5/4/6 sq mm
Supply, replacement/new provision and fixing of Numbers 10.00 BLDC energy efficient (5 star rated) ceiling fan 1200 mm sweep wattage-max 35W with air delivery: min 230 cu/meter/minute (with remote)
Supply, fixing and connection of 6A plug socket- Numbers 01 nos. Switch -6A -01 nos. with board with wire connection. (Modular)
Supply, fixing and connection of 6/16A or 10/20A Numbers plug socket-01 nos. Switch 20A-01 nos. with board with wire connection. (modular)
Extra cost for concealed of 6A/6-16A plug point.
Supply, fixing & connection of SPN 6 way (No of Set module 6+2) MCB sheet steel Distribution Board with metal door including i) Supply of 4 nos SP MCB (6-32A) ii) 01 no RCCB 32/40A (100mA) including all wiring.
Supply & fixing of LED tube light fitting complete Set set 20W (Aluminium housing) System efficacy min120Lm/w.
Supply, fixing and connection of 120W LED Set HIGHBAY light for shed.
Supply, fixing & connection of ceiling rose (6A) for Set light/fan/exhaust/wall fan point
Supply, fixing and connection of LED 16W fittings Numbers 158.00 suitable for Pit/under Cat walk light operating voltage (40- 72V) AC as per specification.
Supply and fixing of SS cage of size min (15.5" x Set 6" x 4") or as per site made with SS angle frame and SS wire mesh for covering the pit light
Supply of power supply unit 3KVA for pit light as Set per specification
Fixing and connection of power supply unit Set (Louvolite transformer) at site location.
Supply and fixing of enclosure of size min (L X W Set X D/2 ' x 3' X 2.5') MS original sheet encloser of 14 SWG with inside & outside anticorrosive ISI brand paint and hinged door to be kept on min 3 feet height tool made with MS angle (76x6) mm placing of power supply unit (Louvolite transformer)
Supply & fixing of perforated cable tray box type Miligram 320.00 with cover size 300 mm x 75 mm - Hot dip galvanized.
Laying of cable through cable tray MALDA DIVISION-ELECTRICAL/EASTERN RLY
Laying of LT cable through the HDPE pipe 50 mm Metre Diameter PE-100 as per IS-4984 or latest for underground cable laying of min 0.75 meter depth including supply of HDPE pipe (Cable will be supplied by Railway) for 25 sq mm cable.
Laying of LT cable through the HDPE pipe 90 mm Metre Diameter (PE-100, PN-6) as per IS 4984 or Latest for underground cable laying of min 0.75 meter depth including supply of HDPE (Cable will be supplied by Railway) for cable 70-120 sq mm cable
Cable trenching, laying as per IS-1255, 1983 or Metre latest. (Cable will be supplied by Railway)
Cable laying through pole/wall/floor as per site Metre requirement as per IS-1255, 1983 or latest. (Cable will be supplied by Railway)
Supply and laying of 3" dia medium gauge ISI Metre brand heavy duty G.I pipe for LT cable Track crossing and road crossing and for rising of cable. (Cable will be supplied by Railway)
Supply, fixing & connection of LED street light Numbers 10.00 70W. System efficacy min-140Lm/W.
Supply, fixing & commissioning of 5 Meters length Set GI octagonal pole with all accessories and necessary RCC foundation.
Supply and fixing of G.I. Pipe heavy gauge size Set 1/1.25 inch dia 2.5 ft. long bended as per site requirement including 2 sets of M.S clamps, nuts & bolts, wiring with flexible PVC Cu. cable through G.I. Pipe.
Supply, fixing, and connection of Bus-bar Set Chamber 4 way of Cap-63A wall mounted including connection of LT cable with proper lugs and cable gland etc.
Supply, fixing & commissioning of MCCB of Cap- Set 100A, 4pole, 415V, 50Hz complete with enclosure.
Supply fixing & connection of Industrial Wall Set Socket Outlet Water tight with Plug of Cap-63A (3P+E+N) for welding point with GI sheet cover.
Supply fixing & connection of Empty box made Set with thermoplastic PC (L X B X H) (mm) (300 x 300 x 170) IP- 66 consist with 4 nos. Al busbar of suitable size of Cap--63A for busbar chamber.
Supply, installation, testing and commissioning of Set LT cubical Panel (with Red, Yellow, Blue indication lamp) made by MS original sheet enclosure of 14 SWG with inside & outside anticorrosive ISI brand paint with cubical Cable Alley box consisting following components: i) 3 phase with neutral copper bus bar of min 300 amps- 01 set ii) Thermal magnetic MCCB 250A 4 pole (36kA, Ics=100%Icu)- including spreader terminal- 02 set (incoming with spare) iii) Thermal magnetic MCCB 63A 4 pole (36kA, Ics=100%Icu) including spreader terminal 04 set (with spare outgoing) iv) Thermal magnetic MCCB 125A 4Pole (36kA, Ics=100%Icu) including spreader terminal 02 set (Outgoing) v) MCB 4P 32A -04 set, (outgoing) vi) MCB 2P 16A -04 set, (outgoing) vii) LT 3 Lines LCD Display, emfis Panel mounted, Multi-Function Energy Meter (For voltage, current & Frequency, Power Factor, Power & Energy) - 01 Set. viii) Earthing terminal- 02 set (Terminal of suitable capacity should be provided within the panel for connection of copper wire and aluminum cable for each small capacity MCCB/MCB outgoing feeder) MALDA DIVISION-ELECTRICAL/EASTERN RLY
Supply, installation, commissioning & testing of Set earthing as per IS:3043 or latest amendment.
Supply and laying of GI strip 12 mm x 6 mm or 25 Kg mm x 6 mm or 50 mm x 6 mm for laying from earth pipe to transformer/body /panel board/ switch board earth neutral connection with LT & HT body etc. Total 2069706.73 Schedule B-Electrical work in c/w "Improvement of Bridge acting as subway beside LC no 19/spl at
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
NewDocumentverificationcertificate.pdf
ATTACHMENT
Deployment of Qualified Engineer
ATTACHMENT
GCC-2022uptoACS11.pdf
ATTACHMENT
TenderDocuments-2022MLDT1.pdf
ATTACHMENT
Checklist.pdf
ATTACHMENT
Technicalcompliances.pdf
ATTACHMENT
CommercialCompliances.pdf
ATTACHMENT
Othercompliances.pdf
ATTACHMENT
Mandatorydocumentslist.pdf
ATTACHMENT
LetterofcreditformatAnnexure-B.pdf
ATTACHMENT
MandatoryupdationLabourdataAnnexC.pdf Labour Data Annexure C
ATTACHMENT
441SpecificationofWorksAnnexureA.pdf
ATTACHMENT
441OtherTenderConditionsAnnexure-F.pdf Other conditions Annexure F
ATTACHMENT
MandatoryupdationLabourdataAnnexC.pdf
ATTACHMENT
DeploymentofqualifiedengineerAnnexure-E.pdf
ATTACHMENT
441OtherTenderConditionsAnnexure-F.pdf
ATTACHMENT
Download all tender documents and submit your bid