Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹30.0 L+₹44,996 (1.52%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹34.7 L+₹5.1 L (17.1%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹36.0 L+₹6.4 L (21.7%)Rejected-Finance R O 218 05 OPP J D A COMPLEX TRIKUTA NAGAR JAMMU J K PIN 180020 | JAMMU | JAMMU AND KASHMIR | 180020 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹39.9 L+₹10.3 L (35.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹43.6 L
EMD Value
₹87,160
Closing Date
22 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE (AF) Leh
HQ CWE (AF) Leh
AUGMENTATION OF ELECTRIC SUPPLY AT SNCOs AND MRS AT AIR FORCE STATION LEH
2024_MES_655854_1
81189/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Leh
As per tender documents
7 documents required · 7 mandatory
₹500
GE(AF) Leh
₹87,160
Yes
16 Jul 2024
25 May 2024
24 Jun 2024
25 May 2024
22 Jun 2024
8 Jun 2024
Amount
Excavation in trenches in any type of soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables and foundation of poles etc. and getting out, complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 metre wide and depth exceeding 1.5 metre but not exceeding 3.0 metre deep for laying of cables and foundation of poles etc. and getting out, complete all as specified and directed.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying, factory made unreinforced precast concrete cable cover HV type-1, flat, of size 300x180x40mm, ISI marked for protection of HT cable , complete all as specified and directed.
Supplying and laying, factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, ISI marked for protection of LT cable , complete all as specified and directed.
Supply, installation, commissioning and testing transformer floor mounted capacity 400 KVA step down, outddor type, 50 cycle/sec (50 Hz), oil immersed air naturally cooled (ONAN) with external cooling tubes, raditors, core type having no load ratio 11 KV/433 volt corresponding to principal tapping, copper winding, delta connected to primary side (HV side) and star connected on secondary side (LV side) in accordance with vector Symbol Dy 11 (Vector group 4) with neutral brought out on LV side and having tapping on HV side for constant output so as to alter/vary secondary voltage in step of +/- 2.5% to +/- 7.5% be changed by means of manual off load tap changing arrangement. The voltage regulation shall be as per relevant IS. The limit of temperature rise after continuous full load run as specified in SSR Part I & IS 2026 (Part 1)/Relevant IS Level 3 standard(BIS) shall be suitably adjusted to suit the maximum ambient temperature prevalling at site (Leh/Ladakh) all as specified. The transformer shall be completed with following fittings and accessories:- (a) Oil conservator with filling hole and cap drain valve. (b) Silica gel breather with connecting pipe, first fill of dehydrating agent. (c) Expansion relief mounted on tank with double diaphram and equalizer pipe connected to conservator (Pressure release valve.) (d) Air release plug (e) Oil temperature indicator of approved range, including shut off valve between conservator and main tank. (f) Winding temperature indicator of approved range. (g) Drain valve with threaded adopter. (h) Sample valve.
(j) Inspection cover (k) Jacking pads, handling and lifting lugs. (l) Wheels (m) Rating plate and terminal marking plate. (n) Extra bushing for neutral out side the LV side. (o) First filling of transformer oil. Note : (a) Contractor shall arrange following tests as site: (i) Full load Test with test load and required T&P. (ii) Polarity Test (b) Any item missed out above but is technically required for safe and proper operation of equipment shall be deemed to be included in the quoted rates (c) The material will be purchased from standard manufacturer only.
M&L for transformer platform made out of rubble stone masonry with 75mm thick cement concrete 1:2:4 type B-1 nominal mix using 20mm graded stone aggregate with rendering 15mm thick on stone masonary surfaces in cement mortar 1:4 finished even and smooth without using extra cement including necessary excavation, removal, returning filling and cement concrete 1:4:8 type D-2 nominal mix using 40mm graded stone aggregate in foundation chain link fence with gate complete are included in same quoted rate all as specified and as directed by Engr-in-Charge. Note:- Platform for transformer shall be designed as per manufacturer of transformer requirement. However Minimum Size of platform shall be 2.0mx2.0mx1.0m.
Supply and fixing/erecting in true vertical position, steel tubular pole, swaged, type 410-SP-55 (11.0m long) conforming to relevant IS , HT, complete with cast iron base plate of size 400mm x 400mm and thickness 5mm, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paint and painting upto 1.5 metre above PCC benching of poles in black & white strips 05 Nos each complete all as specified and directed. Note : Earth work and PCC in foundation and coping shall be measured and paid separately.
Supplying and fixing out door, triple pole, gang operated switch single bank, tilting type suitable to vertical/horizontal mounting consisting of hot dipped electro plated galvanised channel iron base with drop out fuse having 15 Nos insulators 11 KV, copper/copper alloy tinned contacts, copper or chromium plated MS arcing chains capable of making and breakign the magnetising current complete with horizonatal bar, GI pipe as down level coupling and operating handle with locking arrangements and drop out fuzes working voltage 11000 volts 400 Amps including testing complete all as specified and directed
Material and labour for pin type, porcelain, vitreous brown insulator including one galvanised mild steel spindle, 02 Nos, GI washer & 01 No GI nut of 150mm height and 150mm dia for 11000 volts grade complete complete all as specified and directed by Engr-in-charge.
Material and labour for Lighting Arrestor expulsion type for out door use complete with all fittings transmission class discharge capacity 65 kilo Amps suitable for 11000 V including bracket, clamps, nuts, bolts and washers and connecting to earth wire complete all as specified and directed by Engr-in-charge.
Material and labour for Cross arms, bracing, supports, clamps and back plates, fabricated from structural steel section Fe-290 grade E-165 quality including nuts, bolts, washers, and welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of alminium paint over a coat of red oxide primer, complete all as specified and directed.
Material and labour for Plain Cement Concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed.
Material and labour, Plain Cement Concrete (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed.
Material and labour, PCC (1:2:4) type B-1, using 20mm graded crushed stone aggregate, as in coping to parapet walls, electric poles etc., weathering slightly, rounded or chamfered including use waste and necessary form work , complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of High Tension (HT) XLPE insulated, galvanised steel strip or wire armoured, heavy duty, electric power cable, cross sectional area 95 Sqmm 3 core aluminum conductor 11000 volts/6.35 Kv (earthed) grade ISI marked under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note(s): (i) Earth work, sand cushioning and PCC cover for protection of cable shall be measured and paid separately.
Supply, jointing, testing and commissioning of out door type cable end termination (cold shrinkabnle) suitable for HT 11 KV earthed grade XLPE cable of size 3 core to 95 sqmm complete all as specified and directed by Engr - in - charge.
Supply, laying, jointing, testing and commissioning of High Tension (HT) XLPE insulated, galvanised steel strip or wire armoured, heavy duty, electric power cable, cross sectional area 120 Sqmm 3 core aluminum conductor 11000 volts/6.35 Kv (earthed) grade ISI marked under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note(s): (i) Eartharth work, sand cushioning and PCC cover for protection of cable shall be measured and paid separately.
Supply, jointing, testing and commissioning of in door type cable end termination (cold shrinkable) suitable for HT 11 KV earthed grade XLPE cable of size 3 core 120 sqmm complete all as specified and directed by Engr - in - charge.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 300 Sqmm 3.5 core aluminum conductor 1100volts grade underground cable ISI marked including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc,complete all as specified and as directed. Note(s): (i) Excavation & earth work, sand cushioning and PCC cover for protection of cable shall be measured and paid separately.
All as per serial Item No. 22.00 here-in-before but cross sectional area 150 Sqmm 3.5 core .
All as per serial Item No. 22.00 here-in-before but cross sectional area 35 Sqmm 3.5 core .
All as per serial Item No. 22.00 here-in-before but cross sectional area 25 Sqmm 4 core .
All as per serial Item No. 22.00 here-in-before but cross sectional area 16 Sqmm 2 core .
Supply and fix, steel water tubing of 80mm dia bore, light grade, galvanised, with all standard fittings ISI marked , laid in trenches/crossing the road/fixed to pole, complete all as specified and directed. Note : Excavation & earth work as required will be measured and paid separately.
Supply and fix, steel water tubing of 50mm dia bore, light grade, galvanised, with all standard fittings ISI marked , laid in trenches/crossing the road/fixed to pole, complete all as specified and directed. Note : Excavation & earth work as required will be measured and paid separately.
Supply installation, testing and commissioning of Outdoor type LT Panel Board cubical type outdoor Confirming to IS 8623/Relevant IS , floor mounted factory fabricated made out of 3.15 mm thick CRCA sheet CPRI approved dust proof/vermin proof & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming and Outgoing MCCB, MCB and TPN copper bus bars of rating not less 1.5 times the rated cap of incomer MCCB . The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing Outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubicle shall have a bottom channel of size as designed by the manufacturer . A detachable predrilled gland plateof thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air.3 mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP65 degree of protection , complete as specified and consisting the following switchgears and accessories:
(i) Bus bar made up of copper with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 800 amps. (ii) Main Incoming MCCB four pole 415 V AC, current rating 500 amps adjustable type with breaking capacity 36 KA at 415V with thermal magnetic release-01 Nos (iii) Outgoing MCCB 415 V AC, current rating 100 amps,breaking cap 16 KA at 415 V AC = 08 Nos (iv) Digital Ammeter 96x96 mm with suitable CT ratio (v) Phase Indiactor lamp -01 Set (vi) Digital Volt meter (vii) PCC 1:3:6 for grounting 04 legs of LT Panel 45 cm deep below GL all as specified and directed by Engineer in charge
Supply installation, testing and commissioning of Outdoor type LT Panel Board cubical type outdoor Confirming to IS 8623/Relevant IS , floor mounted factory fabricated made out of 3.15 mm thick CRCA sheet CPRI approved dust proof/vermin proof & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming and Outgoing MCCB, MCB and TPN copper bus bars of rating not less 1.5 times the rated cap of incomer . The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing Outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubicle shall have a bottom channel of size as designed by the manufacturer . A detachable predrilled gland plateof thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air.3 mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP65 degree of protection , complete as specified and consisting the following switchgears and accessories:
(i) Bus bar made up of copper with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 300 amps. (ii) Main Incoming MCCB four pole 415 V AC, current rating 200 amps adjustable type with breaking capacity 36 KA at 415V with thermal magnetic release-01 Nos (iii) Outgoing MCCB 415 V AC, current rating 63 amps,breaking cap 16 KA at 415 V AC = 05 Nos (iv) Digital Ammeter 96x96 mm with suitable CT ratio (v) Phase Indiactor lamp -01 Set (vi) Digital Volt meter (vii) PCC 1:3:6 for grounting 04 legs of LT Panel 45 cm deep below GL all as specified and directed by Engineer in charge
Supply and fixing/erecting in true vertical position, steel tubular pole, swaged, type 410-SP-31 (9.0m long) conforming to relevant IS , complete with cast iron base plate of thickness 5mm, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paint and painting upto 1.5 metre above PCC benching of poles in black & white strips 05 Nos each complete all as specified and directed. Note : Earth work and PCC in foundation and coping shall be measured and paid separately.
M&L for PVC insulated weather prof flat twin core copper cable of size 2.5 Sqmm including with PVC conduit of all necessary suitable iron clamp(3 nos), nut and bolts of appropriate size from junction box to street light complete all as specified and directed.
Supply, fixing and connecting junction box of size 300mm x 260mm x 165mm minimum 2mm thick MS sheet with hinged door, comprising of TPN aluminium bus bar of capacity 32 Amp 415 Volt fixed on porcelain insulators, making holes on strips for connecting cables and fixed to street light pole with and including 2 nos MS clamp of size 25mmx5mm incl nut ,bolt, washer and including two coat of synthetic enamel paint over a coat of red oxide and including MCB SP 10A, B curve 10kA breaking capacity complete all as specified and as directed.
Supply and fix Integral LED security light luminaire 45 W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 including GI pipe 50mm ,light grade ,1.7mtr long mounting bracket and providing fixing clamps ,bolts,nuts of suitable size complete all as specified and as directed. Make:Crompton Greaves Cat part No LSTP-60-CDL-M or equivalent in C&S/ Philips
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI strip 32 x 6 as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc all as shown in Electrical Plate No. 3 of SSR Part 1, complete all as directed and specified.
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI wire 4 mm dia as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 15 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc all as shown in Electrical Plate No. 3 of SSR Part 1, complete all as directed and specified.
darshan kumar gandhi
M/s B R Constructions
M/S ZTECH
M/S SHEYSHAN ENTERPRISES
Kaul Enterprises
FANGALIA TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .