| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC | L1 | Accepted-AOC BEING L1. | |
| 2 | L2₹46.4 L+₹6.5 L (16.4%)Rejected-Finance HOUSE NO 87 SHAH FAISAL ABAD DHOBI MOHALLA BATAMALOO SRINAGAR 190009 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190009 | L2 | Rejected-Finance OTHER THAN L1. | |
| 3 | L3₹49.4 L+₹9.5 L (23.9%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Due to not enlisted with category b(ii) | |
| 5 | Rejected-Technical BANPURA BATWARA SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | - | Rejected-Technical Due to not enlisted with category b(ii) |
Tender Value
₹42.5 L
EMD Value
₹85,100
Closing Date
28 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 864 EWS
GE 864 EWS
PROVN OF HARD STANDING WITH ALLIED INFRA AND ADDITION AND ALTERNATION OF BLDG NO P-234 UNDER AOR OF AGE BR-I AND AGE EM OF GE 864 EWS AT BB CANTT SRINAGAR
2022_MES_527580_1
864/WS-20/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
GE 864 EWS, BB CANTT SRINAGAR
As per tender documents
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹85,100
Yes
14 Sept 2022
31 May 2022
30 Jun 2022
31 May 2022
28 Jun 2022
14 Jun 2022
60 days
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out hard/dense soil complete all as specified and as directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
M&L for hardcore of broken stones or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 75 mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in sub base of floors complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for factory made coloured glossy finished machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment (colour and shape of block shall be approved by GE) complete all as specified and directed. Make - SWASTIK / NITCO / RUCHI Note:- Colour and shape of paver block shall be as approved by GE.
M&L for PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in bed plates, coping and like plastering on all exposed surface of concerete, incl necessary use and waste of form work complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM (1:6) complete all as specified and directed.
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4), finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for preparation of new plastered or unplastered surface and applaying three coat of white wash complete all as specified and directed.
Excavation in trenches, n exc 1.5m wide & n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, laying of pipe line, laying cables, poles stays etc. n exc 10sqm on plan & getting out in any type of soil complete all as specified and directed.
M&L for Cement concrete (1:4:8) type D2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM (1:4) complete all as specified and directed.
Dismantling timber scantlings 40 sqcm and over in section, in any position as in unframed/ framed work complete, all as specified and as directed.
M&L for 2nd class soft wood (kail) as in scantling clean sawn, complete, all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete, all as specified and as directed.
M&L for 6mm thick plywood, grade BWR, type BB, fixed with nails to timber frame work, as in ceiling complete, all as specified and as directed.
S&F wooden fillets of 2nd class softwood, wrought rectangular in section of sectional area exc 13 Sqcm and n.exc 25 sqcm fixed with nails etc complete, all as specified and as directed.
M&L for preparation of new wood and wood based surfaces of any description exc 10cm with or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for complete removal of existing treatment by scraping etc and applying a layer of 1 mm thick of birla wall putty on wall/ceiling and applying two coat of OBD complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces and applying two coat of distemper oil emulsion, white or tinted over a coat of primer complete all as specified and directed.
M&L for preparation of new plastered or unplastered surface and applying two coat of cement base paint of approved tint/ colour on wall including cornices, pilasters over a coat of primer complete all as specified and directed.
M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description not other wise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide Zinc chrome primer complete all as specified and directed.
S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joning cleat for fixing etc, complete all as specified and as directed.
S&F Anodised aluminum door powder coated (minimum thickness of powder coating 50 micron) shutters, aluminium section weighting 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 02 Nos each door, hinges, anodised aluminum snap beading screws, incl locking arrangements etc complete all as specified and as directed.
S&F 6.3mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane complete all as specidied and as directed.
S&F Door closer hydraulically regulated, Aluminium (extruded section) body designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specidied and as directed.
S&F Aluminium anodised, barrel tower bolts of extruded section 200mm size complete all as specified and directed.
S&F tubes, 'medium grade' galvanised, 15mm bore dia with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks of capacity 1000 litres, (cylindrical vertical tanks with closed top) triple layer hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including 20 mm bore dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixedcomplete all as specified and as directed. Notes : (i) The water storage tanks shall be 3 layers, HDPE tanks moulded to seem-less perfection of rotational moulding process. The tanks shall be manufactured only from FDA approved special grade of polyethylene and shall be certified fit for potable water. (ii) The tanks shall be white coloured with three layered wall and shall be ISI marked. Also refer paras 18.60 and 18.60 A of MES Schedule Part-I. (iii) Payment for inlet, outlet and over flow pipes and ball valve shall be made separately. However cost of providing necessary GI fittings such as nipples with check nuts for inlet and outlet pipes, GI plug with check nut for over flow pipe and 30 cm long wash out pipe, GI 20mm nominal bore, medium grade and check nut for wash out pipes of size as per actual requirements and as directed shall be deemed to be included in the unit rate of this item. (iv) HDPE storage tanks shall be procured from the manufacturers as per Appendix “D”.
Ditto all as per serial item No. 32.00 described here-in-before but 500 ltrs capacity
S&F 3-layer PP-R Polypropylene random copolymer concealed pipes 50mm dia (outer diameter of pipes) in mm SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
Taking down carefully existing aluminium/copper point wiring on batten or in PVC conduit or in MS conduit with GI earth wire etc (for light, fan, socket or power) complete and making good the disturbed surfaces of walls, floors, ceilings etc to match with existing complete all as specified and directed.
M&L for point wiring complete with PVC insulated and unsheathed, Flame retardant low smoke (FRLS) 1100 volt grade electric cable of 1.5 sqmm (nominal area) with multistranded copper conductor single core in and including rigid PVC surface/concealed conduit not less than 20 mm dia, clip, with suitable MS terminal boxes (not less than 1.0 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint including earth dolly with 3 mm thick plastic laminated sheet top cover of approved colours including 1.50 sqmm green solid copper conductor as continuous earth wire with all accessories including lugs required, complete all as specified and directed for the following :-
One light / fan point controlled by one, one way switch
One 3/5 pin 5 Amp socket outlet point controlled by one, one way switch on independent board.
One 3/5 pin 5 Amp socket outlet point controlled by one, one way switch on same board.
Ditto all as per item No 36.00 described here in before but using 2.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed, flame retardant Low Smoke (FRLS) cable for security light/ 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 2.5 sqmm green solid copper conductor as continuous earth wire with lugs complete all as specified and directed.
S&F switch piano flush button type 6 Amp AC 230 Volts single pole one way ISI marked complete all as specified and directed.
S&F switch socket combination 3 pin 6 Amp AC 230 Volts flush type universal, ISI marked complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal (multipurpose) ISI marked complete all as specified and directed
S&F Ceiling rose, PVC/ polycarbonate, isolated body ISI marked complete all as specified and directed.
S&F LED light fitting 1x20 W, 230 V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED light fitting 10 Watt 3000K LED Bulk head luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete with accessories complete all as specified and directed.
S&F ventilating/ exhaust fan, Heavy PVC body AC single Phase 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed.
S&F in replacement of distribution board iron clad, double door with IP-43 IK-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 Pole 415 Volts 100 Amp rating with rupturing cap 16 kA and 06 Nos of MCB SP 63 Amp 'C' series 10 kA, 06 Nos of MCB SP 32 Amp 'C' series, 10 kA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface walls reqd at site complete all as specified and directed.
S&F wall mounting fan AC single phase 230/240 V of size 300mm sweep including connect with PVC insulated and overall sheathed flexible copper conductor cable of size 0.5 sqmm and incl hanging arrangements made out of MS clamps with nuts, bolts and washers complete all as specified and directed.
M&L for submain wiring of Two single core 6 sqmm size stranded copper conductor PVC insulated unsheathed cable (FRLS) in and including PVC rigid non metalic conduit and one PVC cable 6 sqmm size multistranded copper conductor PVC insulated and unsheathed for continuous earth wire with junction boxes covered with laminated sheet 3 mm thick and other accessories complete all as specified and directed.
Returning filling in, including spreading & leveling, watering and well ramming in layers each not exceeding 25cm thickness complete all as specified & directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 15 to 25 mm bore complete all as specified & directed.
S&F 25mm bore dia tubes, 'medium grade', galvanised, with all fitting, laid in trenches complete all as specified and directed.
M&L for cutting of road/hard standing to a size not exceeding 70 cm in width and not exceeding 90 cm in depth for laying/ removal of GI pipe including making good so as to match with existing finishing with PCC (1:4:8) type D2 (using 40mm grade crushed stone aggregate) 100 mm thick on top including fair finishing with black paint complete all as specified and directed.
S&F in repair CI impellar stainless steel monoblock pump set 1 HP dia screwed both ends and fixed incl all fittings complete all as specified and directed. Note:- Old unserviceable pumpset shall be deposited in MES E/M store.
S&F Gun-metal, globe or gate valve 25 mm bore dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Ditto all as per serial item No. 11.00 described here-in-before but depth exc. 1.5m but n.exc 3.0m
M&L for Cement concrete (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for Cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in benching, coping around poles etc including necessary use and waste of form work complete all as specified and directed.
Supply and lay burnt sub class B bricks for protection for laying under ground cables complete all as specified and directed.
M&L for Sand cushioning to under ground cable, provided with 8 cms thick layer before laying the cable and 15 cm thick after laying and streching the cable complete well ramming/ compressed the sand upto 18 cm complete all as specified and directed. Note:- Punned down thickness upto 18cm shall only be measured and paid.
Supplying, transporting, erecting and fixing steel tubular swaged poles type 410 SP-55, 11.00 meter long, complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified including painting with two coats of aluminium paint heat resistant type over one coat of red oxide primer and making 06 Nos bands/ straps with white and black colour (30 cm wide each) synthetic enamel paint at a distance 30 cm from plinth block and numbering of poles with black bitumenous synthetic enamel paint in 2.5 cm height including tarring one coat on steel surface embedded in concerete foundation complete all as specified and directed. Note :- Excavation and PCC work shall be measured and paid seperately.
Supplying, installation, commissioning and testing of transformer step down 11/0.433KV capacity 100 KVA, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping + 2.5%, 5%, 7.5%, 10% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and terminal plate, plain breather device with silica gel to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug, dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/ dust and vermin proof. Note :- Transformer oil shall be conforming to requirements of IS-335-1993 rev -2005 specification for new insulating oil for transformers. The transformer shall be IS-1180 (Part-I) 2014 with maximum total losses as per energy efficiency level-2 of IS:1180 (Part-I 2014)
M&L for construction of shed and platform for single transformer of size 2.50m X 2.50m X 1.20 m high from natural ground level with brick walling including steps, XPM fencing fixed on angle iron posts upto 1.20m height with gate and locking arrangement, painting etc, complete including lifting / shifting & connection of existing / new transformer complete all as specified and as shown in Drawing No CESZ/TD-287. Note:- Drawing No CESZ/TD-287 is available in the AGE E/M office.
Supply and fix Switch air break gang opertated tripple pole mechanically operated from ground level mounted on 09 insulators outdoor type suitable for vertical instatllation single break provided with locking arrangement for operating handle including seven levers "Navtal" lock consisting of mild steel channel HT post top insulator copper alloy high pressure assembly with drop out expulsion fuses for phases, operating rod of 25 mm dia medium grade GI pipe complete conforming to IS-1018 of 1972 with continuous current rating 200 Amps 11KV grade complete all as specified and directed.
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
S&F cable jointing kit for LT 1.1 KV cable for outdoor/indoor termination heat shinkable type joint complete with jointing meterial and accessories suitable for XLPE armoured aluminium conductor cable 95 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of High Tension (HT) XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty, earthed electric power cable, cross sectional area 95 Sqmm 3.0 core aluminum conductor 11000 volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note:- Gloster/ KEI/ Finolex/ Havells/ RPG
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, screened, stranded aluminum conductor, cross sectional area 95 sqmm 3.5 core, 1100 Volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through roads etc, complete all as specified and as directed. Note:- Gloster/ KEI/ Finolex/ Havells/ RPG
S&F lightning arrestor, linear type complete with all fittings, transmission class, discharge capacity 11 KV 65 kA complete all as specified and directed
Supply and laying/ fixing galvanised tubing light grade 80 mm bore laid in trenches or fix to wall/hole with fitting as required for cable protection complete with necessary fittings/fixtures complete all as specified and directed.
S&F danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letter, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT 20 x 20 cm size complete all as specified and directed.
M&L for Road cutting in trenches, n exc 1 m wide and n. exc 1.5m in depth upto 6 Mtr long; for laying of cables pipes, etc.and getting out.in hard/dense soil and repair the same after laying the pipes/cables of any size and specification by means of suitbale quality Cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in benching, coping etc for repair of existing structure of raods complete including necessary form work complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 600mm X 600 mm X 6 mm thick burried directly in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to and including GI strip 32 x 6 mm thick as earthing lead by means of steel bolts, nuts, check nuts and washers test points made of GI strip 32 x 6 mm, 10 cm long , PCC (1:2:4) type B1 in pits, angle iron 25X25X3mm frame work with precast RCC (1:2:4) type B1 cover reinforced with 8mm dia TMT bars @ 150mm c/c both ways and 12mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 40mm bore upto 5m length for drawing in earth lead, salt, charcol etc. including excavation and earth work in any type of soil, removal of surplus soil to a distance not exceeding 50m complete all as shown in electrical plate No. 3 of MES schedule 2009 part-I and connected complete all as specified including testing on completion.
Supply, installation, testing and commissioning of LT Panel board suitable for 415 Volts, 3 Phase 4 wire, 50 Hz AC supply system confirming to IS:8623/93, outdoor type floor mounted alongwith factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick with ingress protection of IP-54 grade having heat shrinkable sleeves, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof. The panel shall be front/rear openable and having inner & outer shells. The inner shell dully compartmented for each control gear, including powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements. The size of the outer shell should not be less than 1200 mm x 1200 mm x 550 mm, mounted on angle iron stand made out of angle size 50x 50 x 6mm grouted in PCC foundation in cement concrete (1:2:4) type B1 platform 70 cm above the ground level and 45 cm below the ground level (using 20mm graded crushed stone aggregate), including accomodating the following gears and accessories :- NOTES:- 1.Excavation and PCC work for foundation of panels shall be included in quoted rates. 2. Before procurement of LT Panels the drawing for the same shall got be approved from GE. Cost for the same shall deemed to be included in the quoted rates.
M/s Lal Enterprises
M/S Noor Mohammad Shalla
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .