Augmentation of receiving substation
2021_PDD_138844_1
e-NIT No. STD-I / 14 of 2021-22 dated 10/09/2021
Open Tender
Electrical Works
Item Rate
20 days
Bemina
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Executive Engineer STD-1st
₹44,000
Yes
22 Nov 2021
11 Sept 2021
18 Oct 2021
11 Sept 2021
16 Oct 2021
11 Sept 2021
Amount
Supply Installation testing and Commissioning of Indoor type 11 kV Main VCB Panel Board (12 kV, 1250A, 25 kA, with two ratio three core CT 900-450/5, with O/C, E/F relays (IEC61850),.Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (SCADA Compatible)
Supply Installation testing and Commissioning of11 kV ,630 mm² Single Core ,XLPE armoured Cable FRLS. (with one spare length) for 10 MVA Power Transformer
Earthing of Power Transformer (Improvement/strengthening works only)(set of 3 rods) (with telescopic rod of 5 Mtr detachable)
Laying of foundation for 33kV Isolator as per relevant REC Design/standards with providing and ercetion of Lattice structure for the the 33 KV Isolator as per relevant REC Construction standards/design
Providing and Laying of 12 Core 2.5 mm² Control( Cu conductor), 1.1 kV Grade PVC Insulated, steel armoured , stranded conductor FRLS type of reputed make
Providing and Laying of 6 Core 2.5 mm² Control( Cu conductor), 1.1 kV Grade PVCInsulated, steel armoured , stranded conductor FRLS type of reputed make
Providing and Laying of 4 Core 2.5 mm² Control( Cu conductor), 1.1 kV Grade PVCInsulated, steel armoured , stranded conductor FRLS type of reputed make
Providing and Laying of 2 Core 2.5 mm² Control( Cu conductor), 1.1 kV Grade PVCInsulated, steel armoured , stranded conductor FRLS type of reputed make
Supply Installation testing and Commissioning of 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core,Outdoor) 2 ratio three Core 400/200 (1 No. per Φ)
Laying of foundation for 33kV CT set as per relevant REC Design/standards with providing and ercetion of Lattice structure for the 33 KV CT set as per relevant REC Construction standards/design
Supply Installation testing and Commissioning of11 kV outdoor Heat Shrinkable Cable Termination Kits of reputed make
Supply Installation testing and Commissioning of11 kV indoor Heat Shrinkable Cable Termination KitsKits of reputed make
Handling and carriage of 10 MVA. 33/11 KV Power transformer ( ONAN, Copper wound, Out‐door Type, Oil Filled with OLTC and all accessories including HT and LT Terminal connections.) from ECSD Pampora / Divisional Store to site with its subsequent Installation Testing and Commissioning at site (Ahmadnagar Ganderbal) (POWER TRANSFORMERS TO BE PROVIDED BY THE CORPORATION)
Carriage of old 6.3 MVA Power transformer from Site (Ahmad Nagar Ganderbal) to Divisional Store Store Bemina Srinagar. ( Job. Includes Dismantling ,loading carriage unloading at divisional store with transit insurance)
Supply Installation testing and Commissioning of T clamps of sorts
Supply Installation testing and Commissioning of 0.2 ACSR Conductor
KAPH TECH CONSULTANCY (P) Ltd.
Saad Constructions
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .