Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹13.0 L+₹16,133 (1.26%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹13.2 L+₹38,412.50 (3.00%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹13.3 L+₹55,420 (4.33%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹15.0 L+₹2.2 L (17.2%)Rejected-Finance 1 16 70 SAI NAGAR COLONY ALWAL SECUNDERABAD 500 015 | SECUNDERABAD | HYDERABAD | TELANGANA | 500015 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
2 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MCEME SECUNDERABAD
GARRISON ENGINEER MCEME, MCEME CAMPUS, TRIMULGHERRY (POST) SECUNDERABAD - 500015
REPAIR TO PLINTH PROTECTION SUNKEN PORTIONS AND NAHANI TRAPS HARD STANDING AND PATH IN MD ACCN AND OTM IN ZONE II AREA UNDER GE MCEME SECUNDERABAD
2025_MES_706832_1
8682/E8
Open Tender
Civil Works
Item Rate
180 days
SECUNDERABAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MCEME SECUNDERABAD
₹40,000
Yes
22 Jul 2025
6 May 2025
4 Jun 2025
6 May 2025
2 Jun 2025
20 May 2025
Amount
Demoltion of cement Concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed by Engr-in-Charge.
M & L Rendering 15mm thick in CM (1:3) on concrete floor surfaces mixed with integral water proofing compound finished even & smooth without using extra cement. Note : WPC shall be measured & paid separately
M & L for PCC 1:4:8 type D2 using 40mm using graded stone aggregate as in foundations, filling in sunken portions and mass concrete complete all as directed by Engr-in-charge.
M&L for 25mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate complete all as directed by Engr-n-Charge.
M&L APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surfaced by forced applicaion complete all as specified including removal of existing treatment complete all as specified and as directed by Engr-in-Charge.
Supply only Integral water proofing compound
Taking down chowkhats or frames not exc 1.5 sqm each(without taking off shutters from the frames), etc complete all as specificed and as per directed by Engineer-in-Charge.
M&L for Solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube suppling and fixing in opening as per specification and drawing, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing in SSR complete all as specified and directed by Engineer-in-Charge.
S&F for Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, size of hinges in 100mm, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F 150mm long aluminium anodised, barrel tower bolts of extruded section, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F aluminium handles 150mm long fabricated type anodised, etc complete all as specificed and as per directed by Engineer-in-Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to tore (measured overall as fixed along the centre line over fittings and accessories) and as directed
S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors 110 mm dia complete all as specified and directed.
S&F PVC (SWR) 100/110 mm bore single socketed pipes in any length with rubber ring joints fixed to wall height upto 12 mtr with clamps complete all as specified and directed
S&F in repairs PVC(SWR) bend/shoe for 100/110 mm dia complete.
S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors 75 mm dia complete all as specified and directed.
S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls 75 mm dia complete all as specified and as directed.
S & F PVC (SWR) bends 75 mm dia complete all as specified and directed.
S & F PVC (SWR) junction single, 75 mm dia (Single T) equal or unequal complete all as specified and directed.
Excavation in trenches n.exc 1.5 m deep and getting out in hard/dense soil complete all as directed
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm and as directed.
Removing of excavated materials exc 1.5 km but n.exc 5 km and deposited and where directed.
S&F in repairs PVC (SWR) 75 mm dia floor trap, plain with grating including jointing with solvent cement and connecting to existing lines complete all as specified and as directed
S&F in repairs PVC (SWR) gully grap 125/110 mm setting and jointing with solvent cement and preparation of trap hole complete and connecting necessary connections all as directed by Engr-in-Charge
Dismantling of floor hearth or wall tiling including cement mortar bedding complete all as directed
M&L for PCC 25 mm thick type B1 1:2:4 (20 mm graded agg ) as in sub base and as directed.
M&L for 15mm thick screed bed or bedding layer of mortar CM 1:6 for laying of floor finished all as directed
M&L for non skid ceramic coloured dark shade tiles 7 to 8 mm thick area of each tile exc 0.060 sqm but not exc .11sqm in floors etc and jointed in neat cement slurry and pointed in white or coloured cement to match all as directed
M&L for rendering 10 mm thick on fair faces of concrete surfaces in cement mortar 1:4 all as directed
M&L for Glazed ceramic tiles in vertical surface 450X300X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match and as directed.
S & F in repairs, vitreous china squatting pan, 'orissa' pattern of size 580x440mm white, with integral foot rests including concrete bedding & inc. CI 'P' trap, 100mm, complete all as apecified and as directed.
S&F in repair PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe in repairs and as directed.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above GL) and as directed.
M&L for 75 mm thick Cement concrete type B-2, 1:2:4 (40mm graded aggregate) as in sub base and plinth protection and as directed.
M&L for 50 mm sand filling under floors or in foundations including watering and consolidation spread, rolled and consolidated to gradient and camber required and as directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment and as directed.
M&L for 20 mm thick screed bed or bedding layer of mortar in cement mortar 1:6 for lying floor finishes and as directed.
M & L chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick, set jointed and pointed in neat cement slurry with grey cement and pigments and as directed.
M&L for Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) for coping or chamfered on edges and as directed.
Demolition of brick work of any description and in any position not otherwise specifically provided for and as directed.
M&L for old size brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in 1:6 complete all as directed.
M& L for rendering 15 mm thick cement plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces finsished even and smooth without using extra cement and as directed.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint on surfaces of walls and as directed.
S&F in repair PVC connection 15mm size with PTMT nuts of length 600mm and as directed.
S&F in repair 15mm dia brass Stop valves screwed down, high pressure, screwed both ends for iron pipe or for unions etc complete all as specified and directed.
S&F in repair 15mm dia Pillar taps fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed .
S&F in repair 15mm bore Bib taps fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed .
S&F in repair Vitreous China Urinal, Half stall type, white with push type tap all as specified excluding flushing pipe and waste pipe and as directed.
S&F in repair vitreous china EWC white including flush pipe, seat cover etc, including connection to drain (or out going pipe) and to flushing pipe anti syphonage pipes etc complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified, complete all as specified and as directed by Engineer-in-Charge. (Make : Jaguar)
S&F in repair PVC waste pipe, 40mm dia for sink, complete all as specified and as directed by Engr-in-Charge.
S & F in rep Grating doom 100mm dia of PTMT (Minimum weight 25gms), etc complete all as specified and as per directed by Engineer-in-Charge.
Taking up or down, 15mm dia bore, GI tubing, medium grade, including removal from site, complete all as specified and as directed by Engineer-in-Charge.
Taking up or down, 20mm dia bore, GI tubing, medium grade, including removal from site, complete all as specified and as directed by Engineer-in-Charge.
S&F 15mm dia for high density polythelyne pipes (CPVC) of pressure rating 06 kgf/cm2 fixed complete to wall or in floors etc .
S&F in 20mm dia for high density polythelyne pipes (CPVC) of pressure rating 06 kgf/cm2 fixed complete to wall or in floors etc.
harshraj and co (BID ID -3303758)
NEWS CONSTRUCTIONS (BID ID -3305625)
VACON INFRASTRUCTURES (BID ID -3311253)
ATUL ENTERPRISES (BID ID -3303195)
Squad 7 Projects and Services Pvt Ltd (BID ID -3303684)
PARDEEP AND CO (BID ID -3305510)
J.V.V.K.PRABHAKARARAO (BID ID -3310925)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .