Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC NO 229 ANGAPPAN STREET MITTANAMALAI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L1 | Accepted-AOC Being L1 and Reasonable | |
| 2 | L2₹34.0 L+₹2.0 L (6.29%)Rejected-Finance NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹38.8 L+₹6.9 L (21.6%)Rejected-Finance | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹39.0 L+₹7.1 L (22.2%)Rejected-Finance | L4 | Rejected-Finance Not L1 | |
| 5 | L5₹41.5 L+₹9.6 L (30.0%)Rejected-Finance OLD NO 2C NEW NO 7 1 THANGAVELU VAITHIYAR STREET CORPORATION MIDDLE SCHOOL TRIPLICANE CHENNAI 600005 | CHENNAI | TAMIL NADU | 600005 | L5 | Rejected-Finance Not L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
24 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Avadi
Garrison Engineer Office, Muthapudupet,Air Force Area, Avadi Chennai-55
PROVN OF DEFICIENT LIGHT FITTINGS AND FIXTURES IN CERTAIN MD ACCN AND PROVN OF CERTAIN EM WORKS AT VARIOUS LOCATIONS AT AF STN AVADI
2024_MES_686020_1
8254/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Garrison Engineer Avadi
As per Tender Document
8 documents required · 8 mandatory
₹500
GE Avadi
₹90,000
Yes
11 Jan 2025
28 Nov 2024
26 Dec 2024
28 Nov 2024
24 Dec 2024
12 Dec 2024
28 Nov 2024 - 9 Dec 2024
Amount
SCHEDULE A PART I- PROVN OF DEFICIENT LIGHT FITTINGS AND FIXTURES IN CERTAIN MD ACCN
Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated FRLSH ,1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia surface type fixed with suitable clamps on ceiling / roof trusses etc., and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly, including pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet, 60mm deep, concealed in walls, duly painted with two coats of anti-corrosive over a coat of red oxide zinc chrome primer and covered with bakelite hylam sheet cover 3mm thick fixed with cadmium plated screws for housing the switches, socket outlets, fan regulators etc., complete all as specified and as directed for (a) one light point controlled by one switch. Note : Cost of terminal box and cutting chases for concealing box is deemed to be included in the item rates quoted for point wiring.
S&F Switch piano flush type, single pole,5 Amps, 240 volts complete all specified.
S&F for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F ceiling rose 65 X 50 mm , three terminals ,bakelite , surface complete all specified.
S&F LED bulb 9W inverter type upto 4 hrs back up, 6500K complete all as specified and directed.
S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified.
S&F LED building security light fitting 30 W made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07, complete pre-wired and connecting up with suitable twin core flexble copper wire including provision of necessary GI tubing medium grade 25mm bore of pipe 1.5 bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to Bldg etc complete all as specified and as directed.
Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed.
Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 10 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed.
Supply and Fixing of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
S&F MCB DB SPN 12 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB measured separately relevant items.
S&F Load line MCB DB TP&N 4 way, vertical, double door, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for FP MCCB 100 Amps as incomer and SP MCBs 40/63 amps as outgoing with tinned copper bus bar, neutral link, earth link and connecting up and making good the disturbed wall suface complete all as specified and as directed. Note : Incoming MCCB and Outgoing MCB measured separately relevent items.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 40-63 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.
S&F MCCB 100 Amps 415V,16KA, 4 Pole complete all as specified .
Material and labour for earth continuity conductor or main earthing lead fixed to valve on batten or recess or chases or burried in ground or drawing in conduit or any other situation for loop earthing etc as reqd 4 mm dia galvanized steel wire all as specified and directed by Engr-in-Charge
Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core allas specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out any type of soil for laying cables / pipes / erection of poles etc all as specified and as directed.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed.
Returning filling in soil including spreading leveling watering well ramming in layers not exceeding 25 cm each all as specified and as directed.
Laying in trenches fine sieved excavated dry soil including spreading/ leveling, cushioning for underground cables all as specified and as directed.
Supply and laying of common burnt clay building bricks, sub class B size for cable protection all as specified and as directed.
Material and labour for GI tubing light grade 40mm for cable protection laid in trenches in road crossing or fixed to wall/Pole complete all as specified and as directed.
M & L for Cutting of road/path for laying of GI tubing and making the good to disturbed road/ path including provision of PCC 1:2:4 type B-1 using 20mm graded stone aggregate all as specified and directed.
SCHEDULE A PART II -PROVN OF CERTAIN E/M WORKS AT VARIOUS LOCATIONS
Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed.
Supply and Fixing of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified.
Supply, installation, testing, and commissioning of a Dynamic Digital Two AC Timer unit designed for cyclic operation of two air conditioners to ensure balanced load sharing and energy efficiency, with adjustable time intervals (1 minute to 24 hours), a digital LED/LCD display for monitoring and programming, built-in overload, short-circuit, and surge protection, manual override for emergency operation, restart delay for compressor protection, and compatibility with split/window ACs up to 2 Tons capacity each. The unit shall be wall-mountable, fire-resistant, and powered by 230V AC, 50 Hz, with a minimum 1-year warranty from the date of installation, including supply, installation, testing, commissioning, and providing operational manuals and training to personnel all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core allas specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core allas specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out any type of soil for laying cables / pipes / erection of poles etc all as specified and as directed.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed.
Returning filling in soil including spreading leveling watering well ramming in layers not exceeding 25 cm each all as specified and as directed.
Laying in trenches fine sieved excavated dry soil including spreading/ leveling, cushioning for underground cables all as specified and as directed.
Supply and laying of common burnt clay building bricks, sub class B size for cable protection all as specified and as directed.
Material and labour for GI tubing light grade 40mm for cable protection laid in trenches in road crossing or fixed to wall/Pole complete all as specified and as directed.
M & L for Cutting of road/path for laying of GI tubing and making the good to disturbed road/ path including provision of PCC 1:2:4 type B-1 using 20mm graded stone aggregate all as specified and directed.
S&F LED building Street light fitting 45 W made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07, complete pre-wired and connecting up with suitable twin core flexble copper wire including provision of necessary GI tubing medium grade 25mm bore of pipe 1.5 bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to Bldg etc complete all as specified and as directed.
S&F pole mounted Sheet Moulded compound (SMC) Box weather proof with hinged type door off white in colour of size 250 x 250 x 160mm comprising of 1 No.MCB 6 A and 4 rows with terminals , nuts and bolts and connecting up cables with Aluminium terminal lugs complete fixed on poles with suitable clamps including taking down the old unserviceable one complete all as specified and directed.
PSK Enterprises (BID ID -3191484)
Gee Kay Projects (BID ID -3197362)
M/s Omm Muruga Enterprises (BID ID -3196827)
NAVEEN ENTERPRIESES (BID ID -3197103)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .