Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L1 | Accepted-AOC BEING L1 BID
AND EAS
ACCEPTED BY
TC | |
| 2 | L2₹50.0 L+₹10.4 L (26.2%)Rejected-Finance | L2 | Rejected-Finance Being other
than L1 | |
| 3 | L3₹57.1 L+₹17.5 L (44.1%)Rejected-Finance MD 1 236 SECTOR D1 LDA COLONY KANPUR ROAD LUCKNOW U P PIN 226012 | LUCKNOW | UTTAR PRADESH | 226012 | L3 | Rejected-Finance Being other
than L1 | |
| 4 | L4₹57.3 L+₹17.7 L (44.6%)Rejected-Finance | L4 | Rejected-Finance Being other
than L1 | |
| 5 | Rejected-Technical 10TH FLOOR TOWER A3 FLAT NO 1001 MI RUSTLE COURT GOMTI NAGAR EXTENSION GOMTI NAGAR LUCKNOW UP 226010 | LUCKNOW | LUCKNOW | UP | 226010 | - | Rejected-Technical DOCUMENTS NOT UPLODED AS PER NIT CRITERIA |
| Sl No | Description | Qty | Unit | Joy Dey Enterprises L4 | R K CONTRACTOR AND SUPPLIERS L3 | OMVIN ENTERPRISES LLP L1 | VIDYA TRADERS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for cable laying and including taking out of old unserviceable under ground cable complete all as specified and directed. | 648 | Cum | 100 ₹64,800 | 55 ₹35,640 | 120 ₹77,760 | 50 ₹32,400 Lowest |
| 2.00 | Returning, filling in, any type of soil and spreading, in layers not exceeding 25 cm thick complete all as specified and directed | 414.4 | Cum | 80 ₹33,152 | 55 ₹22,792 | 20 ₹8,288 Lowest | 50 ₹20,720 |
| 3.00 | Removal of surplus soil (any type of soil obtained from excavation) to a distance not exceeding 50 metre and depositing where directed & complete all as specified and directed | 233.6 | Cum | 75 ₹17,520 | 55 ₹12,848 | 20 ₹4,672 Lowest | 50 ₹11,680 |
| 4.00 | Supplying and laying bricks common brunt clay building bricks sub class B incl removing of old bricks for cable protection complete all as specified and directed | 19.2 | Per 1000 Nos | 6,000 ₹1,15,200 | 4,100 ₹78,720 | 4,000 ₹76,800 Lowest | 4,000 ₹76,800 Lowest |
| 5.00 | Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable for under ground cable complete all as specified & directed. i.e 18 cm punned down thick shall be considerd for mesurement) | 194.8 | Cum | 90 ₹17,532 Lowest | 500 ₹97,400 | 300 ₹58,440 | 400 ₹77,920 |
| 6.00 | Supply, laying, jointing, testing and commissioning in replacement of 50 Sqmm 3.5 Core cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches,on pole complete all as specified and directed | 1,450 | RM | 250 ₹3,62,500 | 260 ₹3,77,000 | 260 ₹3,77,000 | 170 ₹2,46,500 Lowest |
| 7.00 | Supply, laying, jointing, testing and commissioning in replacement of 70 Sqmm 3.5 Core cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches,on pole complete all as specified and directed | 300 | RM | 350 ₹1,05,000 | 410 ₹1,23,000 | 320 ₹96,000 | 300 ₹90,000 Lowest |
| 8.00 | Supply & fix in replacement sheet metal enclosure indoor type of size 1.2 x 0.9 x 0.3 mtr suitable to fix on wall/floor made out of 2mm thick CRCA sheet having independent compartments suitable for single phase energy meters and MCB provided with front hinged shutters with lockable arrangements and clear glass to visualize the meter reading without opening the compartment with sufficient working space in compartment prewired with single core PVC insulated and sheathed FRLS stranded copper conductor wire of suitable size from bus bar to meter compartment 06 Nos duly crimped with copper thimbles, duly powder coated complete incl taking down old meter panel all as specified and directed by Engr-in-charge and consisting with the following :-
(a) Copper Bus bar for 3 phase 4 wire system of 4 x 360 Amps rated insulated copper strip mounted on resin cast insulators in independent compartment having front openable shutter - One set.
(b) Incoming MCCB, four pole, 415 volts, 250 Amps, 25 KA with adjustable Overload setting Ir = (0.8 to 1.0)xIn - One No.
(c) Out going MCCB, four pole, 415 volts, 100 Amps, 16 KA with adjustable Overload setting Ir = (0.8 to 1.0)xIn - 2 No.
(d) Out going MCCB, four pole, 415 volts, 63 Amps, 16 KA with adjustable Overload setting Ir = (0.8 to 1.0)xIn - 2 No.
(e) outgoing MCB SPN, 63 Amp,10 KA C-Curve - 06 Nos.
(f) Multifuction meter(0-500) Volts with inbuilt selector - One set.
(g) Indicator Lamps LED in Red in Red/ Yellow/ Blue colour - One Set of Three.(h) 3 Phase electonic energy meter with LCD display with optical comm. Port , accuracy Class-01, Rating 10-60 Amp, all std anti tamper features provided., display TOD, Load servey, ttemper information downloading to CMRIthrough optical port. Display in absence of power supply, suitable for AMR -01 No | 2 | Each | 75,000 ₹1,50,000 Lowest | 1,40,000 ₹2,80,000 | 80,000 ₹1,60,000 | 1,00,000 ₹2,00,000 |
| 9.00 | Supply installng, testing and commissioning floor mounted LT panel out door type of suitable size cubical type factory made, weather and vermin proof made out of CRCA sheet 3.15 mm thick appropriate size of panel 1.2 x 1.2 x 0.45 M and 04 Nos legs on angle iron 50x50x6mm each 45 cm long panel duly powder coacted in side and out side with 7 tank process heaving insulated bus bar TPN with openable shutter on both side (Front and rear side) with locking arrangement duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles and connecting to MCCBs with suitable size aluminium strip duly bended and fixed with nut & bolts and washers from bus bar to MCCBs and legs grouted in PCC 1:2:4 type B:1 (20 mm graded stone aggregate) with gland packing to provided for cable approved complete as under.
(i) Aluminium bus bar strip of capacity 320 amps fixed on epoxy insulator - 04 Nos
(ii) Incomming MCCB of current rating 250 Amps with adjustable thermal release 4 pole 415 volts 25 KA repturing capacity - 01 Nos.
(iii) Out going MCCB 4 pole of current rating 160 Amps 415 volts 16 kA repturing capacity - 3 Nos.
(iv) Out going MCCB 4 pole of current rating 63 Amps 415 volts 16 kA repturing capacity - 01 Nos.
(v) Onload change over 200 Amp, 415 volt - 01 Nos.
(vi) Digital voltmeter (0-500 volt) 96x96mm
(vii) Digital ampmeter (0-600 amps) 96x96mm incl with CT,s
(viii) Set of phase indicator lamp R,Y,B with control MCB - 01 Set
(viii) 3 Phase electonic energy meter with LCD display with optical comm. Port , accuracy Class-01, Rating 10-60 Amp, all std anti tamper features provided., display TOD, Load servey, ttemper information downloading to CMRIthrough optical port. Display in absence of power supply, suitable for AMR -01 No | 1 | Each Job | 1,25,000 ₹1,25,000 Lowest | 2,00,000 ₹2,00,000 | 1,40,000 ₹1,40,000 | 1,25,000 ₹1,25,000 Lowest |
| 10.00 | Material and labour for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed. | 2,480 | RM | 200 ₹4,96,000 | 62 ₹1,53,760 | 130 ₹3,22,400 | 60 ₹1,48,800 Lowest |
Tender Value
₹48.5 L
EMD Value
₹97,040
Closing Date
12 Jul 2025, 6:00 pmClosed
GE (EAST) LUCKNOW
GE EAST LUCKNOW PIN 226002
SPL REPAIR REPLACEMENT OF VINTAGE LT PANELS XLPE CABLE METER BOARD AND DBS METER PANEL BOARD AND ALLIED WKS AT BLDG NO P 8 OF AMC C AND C UNDER GE EAST LUCKNOW
2025_MES_699268_2
GE/E/LKO/T-67 OF 2024-25
Open Tender
Civil Works
Item Rate
270 days
GE (EAST) LUCKNOW
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE (EAST) LUCKNOW
₹97,040
Yes
30 Sept 2025
21 Jun 2025
19 Jul 2025
21 Jun 2025
12 Jul 2025
28 Jun 2025
Amount
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for cable laying and including taking out of old unserviceable under ground cable complete all as specified and directed.
Returning, filling in, any type of soil and spreading, in layers not exceeding 25 cm thick complete all as specified and directed
Removal of surplus soil (any type of soil obtained from excavation) to a distance not exceeding 50 metre and depositing where directed & complete all as specified and directed
Supplying and laying bricks common brunt clay building bricks sub class B incl removing of old bricks for cable protection complete all as specified and directed
Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable for under ground cable complete all as specified & directed. i.e 18 cm punned down thick shall be considerd for mesurement)
Supply, laying, jointing, testing and commissioning in replacement of 50 Sqmm 3.5 Core cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches,on pole complete all as specified and directed
Supply, laying, jointing, testing and commissioning in replacement of 70 Sqmm 3.5 Core cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches,on pole complete all as specified and directed
Supply installng, testing and commissioning floor mounted LT panel out door type of suitable size cubical type factory made, weather and vermin proof made out of CRCA sheet 3.15 mm thick appropriate size of panel 1.2 x 1.2 x 0.45 M and 04 Nos legs on angle iron 50x50x6mm each 45 cm long panel duly powder coacted in side and out side with 7 tank process heaving insulated bus bar TPN with openable shutter on both side (Front and rear side) with locking arrangement duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles and connecting to MCCBs with suitable size aluminium strip duly bended and fixed with nut & bolts and washers from bus bar to MCCBs and legs grouted in PCC 1:2:4 type B:1 (20 mm graded stone aggregate) with gland packing to provided for cable approved complete as under. (i) Aluminium bus bar strip of capacity 320 amps fixed on epoxy insulator - 04 Nos (ii) Incomming MCCB of current rating 250 Amps with adjustable thermal release 4 pole 415 volts 25 KA repturing capacity - 01 Nos. (iii) Out going MCCB 4 pole of current rating 160 Amps 415 volts 16 kA repturing capacity - 3 Nos. (iv) Out going MCCB 4 pole of current rating 63 Amps 415 volts 16 kA repturing capacity - 01 Nos. (v) Onload change over 200 Amp, 415 volt - 01 Nos. (vi) Digital voltmeter (0-500 volt) 96x96mm (vii) Digital ampmeter (0-600 amps) 96x96mm incl with CT,s (viii) Set of phase indicator lamp R,Y,B with control MCB - 01 Set (viii) 3 Phase electonic energy meter with LCD display with optical comm. Port , accuracy Class-01, Rating 10-60 Amp, all std anti tamper features provided., display TOD, Load servey, ttemper information downloading to CMRIthrough optical port. Display in absence of power supply, suitable for AMR -01 No
Material and labour for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete all as specified and directed.
Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall etc and making good to the disturbed surfaces to match the existing complete all as specified and directed. Note :- Sunken box/cover plate for modular switches, sockets etc will be measured and paid seperately under relevant items and blank plate required if any will be deemed included in the item rate.and making good disturbed surfaces of wall , floor etc complete all as specified and directed.
All as per serial item No 13 here-in-before but one, two way light point controlled by two, two way switches, 06 Amp.complete all as specified and directed.
All as per serial item No 13 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.complete all as specified and directed.
All as per serial item No 13 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp.complete all as specified and directed.
All as per Serial Item No 13 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F in replacement Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed
S&F in replacement Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed
S&F in replacement Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed
S&F in replacement Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed
S&F in replacement Modular White cover plate with frame,8 module complete all as specified and as directed
S&F in replacement Modular White cover plate with frame,4 module complete all as specified and as directed
S&F in replacement Modular White cover plate with frame,3 module complete all as specified and as directed
S&F in replacement Modular White cover plate with frame,2 module complete all as specified and as directed
S&F in replacement Modular Metal flush box 8 module complete all as specified and as directed
S&F in replacement Modular Metal flush box 4 module complete all as specified and as directed
S&F in replacement Modular Metal flush box 3 module complete all as specified and as directed
S&F in replacement Modular Metal flush box 2 module complete all as specified and as directed
Supply and fix fan step regulator, 120W 2 module complete all as specified and as directed
Supply and fix in replacement of decorative wall mounting type LED light fitting, 1 x 15 Watt, 230 Volt made up of Polycarbonate including shade, lamp holder, 9/10 Watts LED lamp B22 CDL etc and all accessories pre-wired including connecting up complete all as specified and directed.
Supply and fix in replacement of integrated LED bulk head fitting 10 Watt, 6500K with IP 65 protection comprises of high pressure die cast aluminium housing, polycarbonate cover, etc complete all as specified and directed.
Supply and fix LED tube light fittings 1200 mm,20 W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded aluminum housing enviromental friendly, energy efficient complete all as specified and directed.
Supply and fix LED tube light fittings 600 mm, 10 W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded aluminum housing enviromental friendly, energy efficient complete all as specified and directed.
Supply and fix ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed.
Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) MCB, SP, AC, 240 volt of 06 to 32 Amp, "C" curve, 10 KA breaking capacity - 12 Nos.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
Supply and fix 45W Pressure die cast aluminium housing street light with system lumen of 6300 lm and system efficacy of 140 lm/w, IP-66,IK-10 single piece die cast incl spigot, dia 48-76mm,LED lifetime (L70B50) 75000 buring Hrs with integrated optical cover. Street light should have standalone lighting control system with AUTO ON/OFF based on DUSK/DAWN timings,preset time settings with monthly variations (Jan to Dec), inbuilt real time clock for switching, incleds dimming profile for energy savings,drift not exceedind max 2mins/year, clock retention upto five yeras, auto switching off secondary power for module,dimmable driver based on PWM control, dim to off with high/low voltage cut off with 440V protection for 8 hrs for complete luminiarie incl driver and astro module,surge protection as per IEC 61000-4-5 complete all as specified and directed. by engineer in charge.
Supply and fix in replacement of AC modular box with modular 20 Amp MCB SPN suitable for Geyser and AC complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fix in replacement of sheet metal enclosure distribution board, double door, single pole and neutral, AC, 240 volt, 08 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fix in replacement of MCB, SP, AC, 240 volt of 06 to 32 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fix in replacement of ,SPN , AC, 240 volt of 63 Amp 30 mA capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply installng, testing and commissioning floor mounted LT panel out door type of suitable size cubical type factory made, weather and vermin proof made out of CRCA sheet 3.00 mm thick appropriate size of panel 0.9 x 0.9 x 0.45 M and 04 Nos legs on angle iron 50x50x6mm each 45 cm long panel duly powder coacted in side and out side with 7 tank process heaving insulated bus bar TPN with openable shutter on both side (Front and rear side) with locking arrangement duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles and connecting to MCCBs with suitable size aluminium strip duly bended and fixed with nut & bolts and washers from bus bar to MCCBs and legs grouted in PCC 1:2:4 type B:1 (20 mm graded stone aggregate) with gland packing to provided for cable approved complete as under. (i) Aluminium bus bar strip of capacity 200 amps fixed on epoxy insulator - 04 Nos (ii) Incomming MCCB of current rating 160 Amps with adjustable thermal release 4 pole 415 volts 25 KA repturing capacity - 01 Nos. (iii) Out going MCCB 4 pole of current rating 415 Amps 230 volts 16 kA repturing capacity - 2 Nos. (iv) Out going MCB TPN 4 pole of current rating 100 Amps 230 volts 16 kA repturing capacity - 4 Nos. (v) Digital voltmeter (0-500 volt) 96x96mm (vi) Digital ampmeter (0-600 amps) 96x96mm incl with CT,s (vii) Set of phase indicator lamp R,Y,B with control MCB - 01 Set
Supply and fix LED city cube bollard light fittings 12 Watt, robusty designed IP 65/IK 10 bollard and and is easy to install with base plate incl PCC 1:2:3 (size 60 x 60 x 60 mm )incl connector block , nut bolts, connecting up complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 6 sqmm 2.0 core complete all as specified and directed.
M & L for earthing incl eath work complete with galvanised steel earth plate electrode 60x60x6.0mm thick burried directly in ground ( earth pit not less than 2.25 meters deep below ground level) with to edge of the plate not less than 1.5 Mtrs below normal ground level connected to galvanised earth lead 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by GI pipe all as shown in electrical pate No 5 of SSR Part I - 2009 connected to earthing test point all as specified and indicated including excavation earth work PCC chamber RCC chamber cover protection pipe watering pipe funnel and testing on completion all as specified and directed. (Note: Earth strip and protection pipe upto 7.50 m length is included in the unit rate)
Supply, laying, jointing, testing and commissioning in replacement of 35 Sqmm 3.5 Core cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches,on pole complete all as specified and directed
Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 43 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) MCB, SPN, AC, 240 volt of 40 Amp, "C" curve, 10 KA breaking capacity - 08 Nos.
M&L in factory made Pantone 7541C shade powder coated distribution board SP & N 12 way fabricated of CRCA sheet with metal door (IP-43 protection) bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as a incomer and 10 SP MCBs as outgoing complete all as specified and directed
Supply installng, testing and commissioning floor mounted LT panel out door type of suitable size cubical type factory made, weather and vermin proof made out of CRCA sheet 3.15 mm thick appropriate size of panel 1.2 x 1.2 x 0.45 M and 04 Nos legs on angle iron 50x50x6mm each 45 cm long panel duly powder coacted in side and out side with 7 tank process heaving insulated bus bar TPN with openable shutter on both side (Front and rear side) with locking arrangement duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles and connecting to MCCBs with suitable size aluminium strip duly bended and fixed with nut & bolts and washers from bus bar to MCCBs and legs grouted in PCC 1:2:4 type B:1 (20 mm graded stone aggregate) with gland packing to provided for cable approved complete as under. (i) Aluminium bus bar strip of capacity 200 amps fixed on epoxy insulator - 04 Nos (ii) Incomming MCCB of current rating 250 Amps with adjustable thermal release 4 pole 415 volts 25 KA repturing capacity - 01 Nos. (iii) Out going MCB MCCB 4 pole of current rating 100 Amps 230 volts 16 kA repturing capacity - 4 Nos. (iv) Digital voltmeter (0-500 volt) 96x96mm (v) Digital ampmeter (0-600 amps) 96x96mm incl with CT,s (vi) Set of phase indicator lamp R,Y,B with control MCB - 01 Set
Supply and fix cast aluminium heavy pole designer leg and border designer base finished with polyurethane paint (with prior treatments) diamtr of one leg is approx 76mm outer dia for spiogot entry 60mm 03 Nos "T" shaped bolts with nuts and washers provided for concrete foundation , total length of the pole incl base and legs (base x 03 Nos legs) is 2463 MM (Appx 8 fit 1 inch ) with fully cast aluminium finish polurethane paint( with prior tretments) suare junction with max projection breadth of 625 mm suitable for two number post top lantren with polyurethane ( with prior treatments ) Paint with arylic window cover total length 533 mm and breadth 228 mm.B-22 brass provided with qaluminium cover incl PCC 1:2:3 (size 600 x 600 x 600 mm ) foundation, , nut bolts, connecting up complete all as specified and directed.
VIDYA TRADERS (BID ID -3356002)
R K CONTRACTOR AND SUPPLIERS (BID ID -3356874)
Joy Dey Enterprises (BID ID -3348529)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .