Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-Finance | L1 | Accepted-Finance 1st lowest | |
| 2 | L2₹16.8 L+₹2,913.34 (0.17%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹16.9 L+₹6,045.29 (0.36%)Rejected-Finance BANSHBARI MALDA | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹29,615
Closing Date
12 Jul 2024, 10:55 amClosed
Executive Engineer, PWDte
Bankura
Repair and Renovation of Primary Health Centre at Pakhanna PHC in Bankura ----- EI Work.
2024_WBPWD_702028_1
WBPWDTE/EE/BED/NIQ_74/Q of 2023-24-2nd Call Tender
Open Tender
EPABX M/R
Item Wise
45 days
Pakhanna PHC
Please refer Tender documents.
3 documents required · 3 mandatory
₹29,615
22 Jul 2024
28 Jun 2024
15 Jul 2024
28 Jun 2024
12 Jul 2024
28 Jun 2024
Amount
Part A: Electrical Installation Works Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- RR Kabel/ Havells/ Polycab/KEI/ as per direction of EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand/ Schneider/ Crabtree/ Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish as per GS. 8 Mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- RR Kabel/ Havells/ Polycab/ Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Legrand/ Havells/ L&T/ Goldmedal/ as per direction of EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works as per GS. On Board
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works 20 mm size
25 mm size
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make- RR Kabel/ Havells/ Gloster/ as per direction of EIC) of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS. 3 x (1.5 sqmm)
2x(2.5 sqmm)+1x(1.5 sqmm)
2x(4 sqmm)+1x (2.5 sqmm)
2x(6 sqmm)+1 x (4 sqmm)
S & F solderless Copper socket by crimping of Copper wires. a)2.5 sq mm
b)4 sq mm
c) 6 sq mm
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works incl. supply & fixing bakelite/perspex top cover by Brass screws as per GS. 175 x 100 x 65
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as per direction of EIC. 4 Way ( Up to 160 A ) (Make-Legrand/L&T/ABB/Havells/as per direction of EIC)
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS (Make-Legrand/L&T/ABB/Havells/as per direction of EIC) 160A
Supplying and fixing double door Horizonal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS. 6 Way (Make-Legrand/L&T/ABB/Havells/as per direction of EIC)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+12 Way (Make-Legrand/L&T/ABB/Havells/as per direction of EIC)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS (Make-Legrand/L&T/ABB/Havells/as per direction of EIC) 63 A FP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS (Make-Legrand/L&T/ABB/Havells/as per direction of EIC) 6-32 SP
Supplying and fixing 240/415 V change over (MCB module) of on din rail of existing DBs/ enclosure and necessary connection. [Make-L&T/ABB/Havells/Siemens/as per direction of EIC] 40A DP
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical / SPNDB enclosure with IP-42/43 as per GS 4/6/8 Way (Vertical) (Brand approved by EIC)
Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure suitable for following capacity with nuts bolts etc incl. powder coated painting. a)63/125/160A (Brand approved by EIC)
Supplying and fixing 415V, 160A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating as per GS. [Make- L& T/ABB/Havells/Siemens/as per direction of EIC]
Supplying and fixing 415V, 160A TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc as per GS. [Make- L& T/ABB/Havells/Siemens/as per direction of EIC]
Supplying and fixing of 415V 3 nos 200 A (Porcelain Fuse carrier & Base-Specification: IS: 2086) Kit-Kat Fuse unit with 1 no. Brass Neutral connector on suitable size of Hylam sheet of minimum 12mm thick incl S&F of angle Iron frame per direction of E.I.C. [Make- L& T/ABB/Havells/Siemens/as per direction of EIC]
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make- RR Kabel/ Havells/Gloster/ as per direction of E.I.C]. 2 Core 10 Sq. mm
4 Core 35 Sq. mm
4 Core 70 Sq. mm
Laying of cable of 2 core 10 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Laying of cable upto 3/4 core 35 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 X10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting as per GS.
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed as per GS.
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes. From 2.5 sqmm to 35 sqmm at an average depth of 75mm
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. (Brand approved by EIC) 2 Core 10 Sq. mm
4 Core 35 Sq. mm
4 Core 70 Sq. mm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required as following size as per GS. (Brand approved by EIC) 50 mm dia
Supplying and fixing MCCB SS enclosure with IP?20/30 protection, powder coated provision for housing Four pole (4P) MCCB, concealed in wall after cutting the wall & mending good the damages to original finish / on flat iron frame incl. painting, connection & provision for earthing attachment(Make-Legrand/L&T/ABB/Havells/as per direction of EIC) 2 Way
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 6 Module (Legrand/ Havells/ L&T/ Goldmedal/ as per direction of EIC)
Supplying & Fixing modular type socket /socket (Legrand/ Havells/ L&T/ Goldmedal/ as per direction of EIC), in exsisting Modular board incl. connections. 6 A 5-pin modular type 5 pin socket
6 A modular type switch
Supply & Fixing 240 V, 1 nos. 16A & 3 nos. 6 A, 3 pin Modular type plug socket with 1 nos. 16A & 3 nos. 6 A Modular type switch (Make- Legrand/ Havells/ L&T/ Goldmedal/ as per direction of EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket, without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make- Legrand/ Havells/ L&T/ Goldmedal/ as per direction of EIC)
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Make- Legrand/ Havells/ L&T/ Goldmedal/ as per direction of EIC) & necy. Connections.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc (Make- Legrand/ Havells/ L&T/ Goldmedal/ as per direction of EIC)
Supply and delivery of single/twin Industrial LED Batten luminaries incl. Supply of 1 no./2nos. 18W LED Tube Twin Fittings (Make- Philips, Cat No. TMC-502 P2xT-LED 22W or equivalent model of CG / Wipro/Jaquar/ as per direction of EIC) incl. 2 no. 22W Master LED Tube
Single Fittings (Make- Philips, Cat No. TMC-502 P1xT-LED 22W or equivalent model of CG / Wipro/Jaquar/ as per direction of EIC) incl. 1 no. 22W Master LED Tube
Supply & Fixing of 240V, 70 W LED Street light luminare (Make:- Phillips, Cat no. BRPO62 LED 82 CW SLC S1 PSU or equivalent make of CG/wipro/ Jaquar/as per direction of E.I.C.) on Mini Pole as per direction of E.I.C
S & F 28W 120-270V, 50Hz Post top LED light Fitting to be fixed by S & F of 50 mm dia GI pipe (2ft long) on top of the gate pillar & making connection. (Make- Philips, BGP300 LED28 757 PSU PC IN S1 or equivalent make of CG/wipro/ Jaquar/as per direction of E.I.C.) for Main Gates. The scope of work also includes the SW & F of 600 mm long 50mm dia GI pipe on top of the gate pillar after making hole & mending good the damages with cement morter mixture as per direction of EIC.
Fixing only single/twin LED batten light fitting suspended from the ceiling fixed with “L” type MS clamp for RC ceiling / MS pipe as per GS direction of EIC
Fixing only single/twin LED Batten light fitting complete with all accessories Directly on wall/ceiling as per GS.
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply & Fixing angular batten holder (Brand approved by EIC) on 75mm dia PVCround block / round bakelite on wall/ceiling as per GS.
Supply and fixing 14W LED bulb (Make- Philips/CG/Wipro/Jaquar/as per direction of EIC) on existing batten holder
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor/as per direction of EIC) on HW board incl. S&F HW board as per GS.
Supply of ceiling fans with burst-proof P2/S3 Capacitor complete with all accessories without regulator. ( Make -Usha striker/equivalent model of Orient /CG/ as per direction of E.I.C.) as per direction of E.I.C 1200 mm Sweep
1400 mm Sweep
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supply & fixing 300 mm Heavy Duty Exh. (920 RPM) Exhaust fan (Make- EPC/ CG/Usha/Orient/Havells/ as per direction of EIC) of followinng sizes after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust as per direction of E.I.C. 12"( 300mm ) Speed 920 RPM
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall as per GS (12")
Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide – (As per Drawing no. 476 of PWD Specification Book – May 1991)
Supply & Fixing Socket type fan regulator (Step type) (Make- Legrand/ Havells/ L&T/ Goldmedal/ as per direction of EIC) on existing sheet metal switchboard with bakelite/perspex top cover by screw aftermaking housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc as per GS.
Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire as per GS.
S & F mini pole on roof top by 80 mm dia., 2 Mtr. Long GI(M) pipe medium quality (Make- Bansal/Jindal/ as per direction of EIC) incl. making cc (6:3:1) muffing 600x600x750 mm in size with 3 mm thick neatly finished cement plaster incl. S & F 10”x10”x4” C.I. looping cable box incl. S & F 40 mm. dia. G.I.(M) 1.5 Mtr. Long arm bracket for fixing flood light & neccy connection by 2x 1.5 sq mm Cu wire. This is incl. painting as per GS.
Supply & Delivery of 9 Mtr Steel Tubular Pole (Steel Make- Zindal/Bansal/ as per direction of EIC) GI pole manufacturer(Make- Subham Pole/Bajaj/Transrail/Calcutta poles) as per Pole specification type-410-SP-26 as overall length:- 9 mtr, base plate (220x220x12mm) welded at bottom, pole cap, & having diamention are : Out side dia & thickness of the Bottom section ( 114.3 x 3.65) mm,length- 5000mm , Mid Section (88.9 x 3.25 ) mm , length - 2000 mm, Top Section (76.1 x 3.25) mm, length - 2000 mm, the pole to have a hinged(2 hinges) door with alankey type mechanical lock at a height of 2.45m from bottom of it incl S&F of a 240V,C curve, 6A SPMCB (MK- Legrand) on din rail, 16A rating 2 pole stud fixed on bakellite board within the pole and GI earth bolt after making drilled holes etc. on pole as per direction of EIC.
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts.above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly (2 nos. are considered for poles and 4 nos. are considered for mounting the structure of Glowsign board). Upto 9.0 mtr. Size 0.6x0.6x1.70 mtr.
Extra on items 1& 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.45x0.45x0.60 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 20cmx15cmx10cm GI Loop box, 16SWG & incl. drilled hole in pole as per GS.
Extra on items 1& 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.45x0.45x0.60 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/polythene pipe entry, for street light wiring, without Loop Box
S&F 40 mm. dia 1 mtr. long detachable type G.I. Single arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC. (Make- Subham /Transrail/Calcutta poles/ as per direction of EIC)
S/F Stainless Steel water proof looping cable box (Brand approved by EIC) of size 200x150x100mm having hinged top Cover with rubber gasket lining, railway type mechanical locking anangement, earthing terminal with lug etc.
SITC of 6 kVA Double conversion IGBT based true on line UPS, 1 Phase input and 1phase output with built-in Isolation Transformer on the Inverter output along with suitable Battery Rack and interlinks(Make-Power One/Neumeric/APC/Microteck) In-built isolation transformer , Open battery rack & Battery interconnecting cables. Systems D.C.Bus : 72 V Battery Make : Exide / Amara Raja Battery Details : 12v, 42Ah x 16 Nos SMF battery bank to provide 60mins backup (VAH-8064)(Make-Exide/Amararaja) Terms & Condition : Warranty : 24 months from the date of installation for both UPS & Batteries .
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) as per GS
Extra for treatment of soil by using salt & charcoal or coke for plate electrode as per GS.
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS. No.-4 SWG
No.-10 SWG
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS
Supply and Fixing of LED Tube illuminated sign board fabricated by 20'(L)x4'(H)x10"(W) ACP box supported with 50 x 50 x 6 mm M.S. Angle structure all around with 40mm x40mmx 1.62 mm Al. edge angle for front portion only.The back side of the cover will be fabricated with hinges and arrangement in such a way so that it can be opened for maintenance purpose, including mechanical locking arrangement .The 3 mm ACP facial (Blue colour) should be provided with laser cutting of 6 mm laser cut Acrylic letters out of which 5 mm rising and back portion of the ACP board should be pasted with 2mm thick Clear Acrylic Sheet of same size as ACP facial as per the direction of EIC.The sign board should be illuminated by 18W LED Tube lamps (25 nos.) (Type- MAS LED Tube lamp 22 W 2100 lm) with Tube fittings (Phillips make) to be fixed by hooking arrangement with iron stucture fabricated for fixing purpose. Distribution wiring for power supply to LED fittings to be done by PVC rigid conduit, necessary clamps, cable tie etc. Back side of the of the board should be covered with 20 SWG G.I. sheet to protect rain water. The matter to be displayed will be finalised by authority and to be given later.This fabricated display structure is to be fixed on the top of prefabricated iron structure as per direction of EIC.
M.S. structural work in column beam etc. with simple rolled structural members(e.g. joist, angle chanel,section) i) For stuctural members of specified sections weighing not less than 22.5 kg per meter.( Page 99, item 1( I ) of PWD schedule) Supplying M.S. angle (50 x 50 x 5 mm) 4.5 kg/mtr.(19.1 mtr)
Supply of MS base plate (8mmx305mmx508mm) 9.8 kg per plate (4nos)
Supply of MS Channel (150x75x6mm) (13.6 mtr.)16.79 kg/ mtr.
Supplying M.S. flat (50 x 6 mm) (11.1 mtr.) 1.2 kg/mtr.
Fabrication charge of the iron structure incl. hiring of welding machine incl. making connection as required.
GENUINE ENGINEERING WORKS
M/S KUNDU CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .