Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC 49 1 ISWAR GUPTA ROAD KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹25.0 L+₹32 (<0.01%)Rejected-Finance 677A DIAMOND HARBAR ROAD HINDUSTAN PARK BEHALA KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L2 | Rejected-Finance Due to Highest Bid quoted | |
| 3 | L3₹25.7 L+₹70,519 (2.82%)Rejected-Finance 39 MAHESHMATI BANK COLONI MALDA WEST BENGAL | MALDA | MALDA | WEST BENGAL | 732101 | L3 | Rejected-Finance Due to Highest Bid quoted | |
| 4 | L4₹26.2 L+₹1.2 L (4.69%)Rejected-Finance GROUND FLOOR 109 186 114 LAHIRI VILLA NEW BANSBARI MALDA WEST BENGAL 732102 | MALDA | MALDA | WEST BENGAL | 732102 | L4 | Rejected-Finance Due to Highest Bid quoted |
Tender Value
Refer Docs
EMD Value
₹51,347
Closing Date
30 Nov 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE II CKHED
P12 CIT Road 1st floor Kol 14
Construction of New Pediatric HDU over the building designated ESWL UDS Room at First Floor of Baker Building under the NRSMC and H Kolkata
2024_WBPWD_765544_1
WBPWD/EE-II/CKHED/ eNIT-68/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
NRS MCH
As per nit
4 documents required · 4 mandatory
₹51,347
central kolkata health electrical division
8 Oct 2025
28 Oct 2024
3 Dec 2024
28 Oct 2024
30 Nov 2024
6 Nov 2024
5 Nov 2024
Amount
Distn. Wiring in 22/0.3 (1.5 sqmm) single core standard 'FR' PVC insulated & unsheathed single core standard copper wire (Finolex/Havells/RR/Kable Unilay) in 19 mm core, 3 mm thick polythyn pipe complete with all accesorries embedded in wall to light/fan/call bell points with modular type switch (Brand approved by EIC) fixed on modular GI switch board with top cover place flushed in wall incl. mending good damages to original finish. (Average run 8 mtrs.)
a) On board [Vide page no-E-24,item no-3(a)]
b) Average run 10 mtr [Vide page no-E-25,item no-5(e)]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Gloster/RR Kable/Finolex) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire incl. cutting channel and making necy. connection as required. [E-9,1]
a) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [Vide page no-E-9,item no-1(s)]
b) 2x6 sqmm+1x 4 sqmm ECC) [Vide page no-E-9,item no-1(y)]
c) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [Vide page no-E-9,item no-1(a1)]
d)3x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC[Vide page no-E-9)
e) 4 x 10 sqmm+2x 6 sqmm ECC) [Vide page no-E-9,item no-1(d1)]
f) 4 x 16 sqmm + 2 x 10 sqmm ECC) [Vide page no-E-9,item no-1(g1)]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.[Vide page No F-5, Item No-9 (i)& (ii)]
a) 2x2.5 sqmm+1x 1.5 sqmm ECC [F-5,9(i)]
b) 2x4 sqmm+1x 2.5 sqmm ECC [ F-5,9(ii&i)]
c) 2x6 sqmm+1x 4 sqmm ECC) [ F-5,9(iii&ii)]
d) 4 x 10 sqmm + 2 x 6 sqmm ECC [ F-5,9(iv&iii)]
e) 4 x 16 sqmm + 2 x 10 sqmm ECC) [ F-5,9(v&iv)]
Cutting channel of 31 mm x 31 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire fish wire incl. mending good damages to building works
a)13 mm dia 3 mm thick polythene pipe without earth continuity wire.
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
a)19 mm dia 3 mm thick polythene pipe without earth continuity wire.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [ D-9,13 ] Incoming - 230V,40A, DPMCB Isolator [Legrand] (1-nos) [D-5,6] Outgoing - 10KA, (C-characteristics) 6-32A, SPMCB [Legrand] - (12-nos) [D-6,7]
2+12 way [Legrand/ L&T]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [D-10, 14] Incoming - 415V,63A, FPMCB Isolator [ Legrand ] (1-nos) [ D-5,6 ] (1-nos) Outgoing - 10KA, (C-characteristics) 6-32A, SPMCB [ Legrand ]- (18-nos) [ D-6,7 ]
6 way [Legrand/ L&T]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Vide page No D-11, Item No-15] Incoming - 415V, 25/35KA, 160A, FPMCCB (1 -nos)[Vide page No D-8, Item No-10] Outgoing - 10KA, (C-characteristics) 63A, TPMCB - (6 -nos)[Vide page No D-6, Item No-7
6 way [Legrand/ L&T]
Supply & Fixing 240 V, 4 nos. 6/16 A, 5 pin Modular type plug socket with 4 nos. 16A Modular type switch, 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-19,15 ] (Make:- Legrand/Cabtree)
Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-18,13]
Supplying & Fixing Industrial Plug & Socket board with 415 V, 30A, TPN & Earth Metal Industrial Plug socket & 30A Industrial top incl. S&F 32 A TPN/FP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. [D-12,18]
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket without plug top on 2 Module GI Modular type switch board with 2 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:- Legrand/Cabtree) [E-17,2(a)&4(c)]
Supply & Fixing 240 V, 25 A, Modular type starter and 2 Module GI Modular type switch board with 2 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:- Legrand/Cabtree) [E-19,20(a)&2(a)]
Supplying & Fixing of PVC water proof type Loop box(Make-Sintex) of size 8"X10" comprising of 4 way 100 Amp. Capacity brass Stud/ terminal make- AC /DC. & 63A FP MCB (L&T) having hinged PVC top cover & 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement,one NL on porcelain insulator etc. on wall as per direction of EIC
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision with 415V,63A four pole MCB,concealed in wall after cutting the wall & mending good the damages to original finish incl. painting,connection & provision for earthing. attachment(D6/7+D9/11)
S & D 48″ sweep, 230V 1-Ph. AC ceiling fans incl. all accss. The capacitor of fan must be P-2 type brust proof & must have safety wire directly linked from fan hook to stator of fan. 1200 mm Sweep [Make:Crompton-Aura Metallic/Orient-Quassar) --- Color-Brown], as directed by EIC.[N.S.]
Supply Single LED T/L fittings( Philips TMC 501 P 1xT-LED 22W P3241) incl. 1x MAS LED tube (PC body) 1200mm 18W865 T8 I --2100 lm.)/Crompton/Bajaj)
Supply Twin LED T/L fittings( Philips TMC 501 P 2xT-LED 22W P3242) incl. 2x MAS LED tube (PC body) 1200mm 18W865 T8 I --2100 lm.)/Crompton/Bajaj)
S & F of recessed mounted 2x2 LED luminaries down light LED fittings [make- Crompton Cat no LCTLRNE-36-FO-CDL or equivalent cat of Bajaj/Phillips] directly suspended from the ceiling with S & F of 2x2 LED luminearies frame incl. connecting the length of PVC insulated wire and mending good damages to original finish and painting as directed by EIC.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [ C-3,21a ]
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “U” type MS clamp whose both side fixed on ceiling with suitable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 3x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. ][Vide page No C-2, Item No-17]
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 3x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [Vide page No C-2, Item No-16]
Supply and Delivery of 1.1 KV grade following sizes Al. armoured PVC/XLPE cable (Gloster/Havells/polycab/KEI/Currency) as mentioned below as per choise of EIC.
a) 4 Core 70 sqmm(panel to VTPN)
b) 4 Core 185 sqmm(Out side Fedder panel to building floor panel)
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. [[Vide page No F-1, Item No-2(d)]
Laying of one cable above 150 sqmm and upto 300 sqmm through existing covered masonry trench incl. taking out RC covers,setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below. [[Vide page No F-4, Item No-7]
a) 4 Core 70 sqmm
b) 4 Core 185 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. [Vide page No F-5, Item No-8(b)]
a) 4 Core 70 sqmm
b) 4 Core 185 sqmm
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board. [Vide page No D-13, Item No-20a ]
Supplying & Fixing of 250 volts, 50Hz, sweep 1420 R.P.M. heavy duty exhaust fan complete with all accessories after making hole on wall and mending good damages as per practicable incl.(Make-EPC) as to GS.
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) [D-14,32 ]
300 MM (12”) for Al [D-14,32(a)]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below theground level as below:
By TATA-Medium GI pipe
LT panel with IP66 Enclosure Box:-
Supply,Installation,Testing of Cubical type floor mounted LT panel Board of suitable dimension comprising of the following electrical accessories fabricated from 40X40X5 mm MS angle and 14 SWG CRC Sheet with necy. Welding incl painting with 2coats of Synthetic Enamel paint over 1 coat of RO primer as per GS.Whole arrangement must covered with suitable enclosure like Feeder pillar Box, should have IP-66 Protection class (As the panel may install at outside the generating station, i.e in open space),Should have Body earthing terminal etc and with proper door lock arrangement. A. INCOMING:-- 1)Supplying and fixing 415V, 415 A TPN on load front operated Changeover switch open execution type in SS enclosure/Cubical with nuts bolts etc. B.Bus Bar:- 4 nos tinned Copper bus bar of size (80X5) mm, length as per requirement each having for Phase and N in Sheet metal box (14 SWG) with hinge type door with locking arrangement with telescopic screw -1 no.Panel should have continious earth busbar for Body earthing. C.OUTGOING:--(all are SS enclosure type) 1) S & F 415V, 200A, 36kA, 4 Pole MCCB (make -- Legrand, Equivalent L&T, Schneider) ---1 nos With Thermal magnetic release; Type DPX3 160 Cat no 4200 95, with spreader terminal,MIL base plate etc as required. 2) S & F 415V, 160A, 36kA, 4 Pole MCCB (make -- Legrand,Equivalent L&T,Schneider) ---3 nos With Thermal magnetic release; Type DPX3 160 Cat no 4200 93, with spreader terminal,MIL base plate etc as required. 3) S & F 415V, 100A, 36kA, 4 Pole MCCB (make -- Legrand, Equivalent L&T, Schneider) ---3 nos With Thermal magnetic release; Type DPX3 160 Cat no 4200 95, with spreader terminal,MIL base plate etc as required. CABLE ALLEY cable alleys on both sides for out going connection are to be made incl. S & F suitable nos of Brass Studs type connector on insulated chair having current carrying capacities as per the out going switches rating. Inter connection with the M S & Stud connectors is to be made with suitable size stranded copper wire as per the switch rating as specified in Interconnection
INTERCONNECTION Inter connection to be made same with 20X5 mm (For 125A and 160A MCCB) and 15x3 mm (for 63 A MCCB) copper bar/ 35sqmm (For 125A and 160A MCCB) &16sqmm(for 63 A MCCB) stranded flex copper cable (Finolex/Havells/Polycab/RR kabel) & metering circuit with 1.5 sq mm single core stranded FRLS PVC copper wire with proper copper socketing & taping ( R Y B & N). All nut bolts are of Stainless steel type.
READING ARRANGEMENT a) S & F digital multifunction meter (L&T, MFM5010 LED meter CI 1.0 with RS485, cat no-- WL501011OOOO/Schneider Conzerv-EM6400NG)---1nos (for incoming ) c) 250A/5A CT Coil ( Kappa Make) - 3 nos (for incoming) e) LED type indicating lamp ( R Y B ) - 3nos (incoming) f) 2 A MCB ("C" curve, Legrand) --- 3 nos g) Danger board -- 02 no
Drawing and Make,cat no of all items and Cubical Panel must be approved prior any execution/manufacturing work.Test reports of each MCCBs and others should be submitted along with the drawing for necy. approval from EIC.
Supply & Delivary 5TR capacity concealed type Split Air Conditioner of rated cooling capacity of 60000 BTU/hr. with 3Nos. rotary compressor, 3nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-400V-3ph-50Hz. Air-flow/per IDU:- 2000CFM. ( Make: Hitachi/Mitsubishi-Electric)
Supply 2 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 36000 BTU/hr. with 2Nos. rotary compressor, 2nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU. Air-flow/per IDU:- 800CFM. ( Make: O-general/Mitsubishi-Electric)
Erection & Commissioning Charges incl. refrigerant R-410A for 5 TR concealed type Split Air Conditioner
Erection & Commissioning Charges incl. refrigerant R-410A 3TR TR concealed type Split Air Conditioner
Copper Refrigeration pipe line for liquid and suction line with fittings, elbows, bends, supports & brackets (Make-Ryoku)
a) Liquid Line (3/8" OD with 0.6 mm thick)
b) Suction Line (5/8" OD with 0.7mm thick)
Supply & Fixing Pipe Insulation in liquid & suction line with 9mm nitrile rubber tube (Accoflex)
a) Liquid Line (3/8" OD with 0.6 mm thick)
b) Suction Line (5/8" OD with 0.7mm thick)
Control copper Cabling from Condensing Unit to control panel (Make: KEI/polycab/ finolex)
a) 4 core 2.5 sq.mm communication cable
S & L of Drain Water piping work out of PVC / HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors.
a) 25 mm dia
Charges for scaffolding arrangement incl. lifting for outdoor & indoor units
Supply and fixing flexible canvass connection for concealed split air-conditioners.
charges for trap door of 1600 mm x 600 mm and 9 mm thickness made of aluminium channel & ply wood for IDU maintenance.
Supply and Fixing AL power Coated countintuous girll (Make-Premier)
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (50 mm x 50 mm x 6 mm) for making platform for installation of outdoor unit of Concealed split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be barricaded & safe for ODU maintenance. Area of the platform is 3Mtr. x 1.2Mtr. Structural design should be approved by E.I.C.
Supplying, fitting & fixing in position suspended boxing for return air arrangement & indoor units of concealed split airconditioner with frame work of aluminium hollow section of size 50mm x25mm (2.0mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm x 25mm ,25mm x 25mm powder coated wall angle with aluminium composit panel of thickness 3.0mm comprising of protective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent including suitable arrangement for grill fixing complete in all respect as per direction of EIC.
Cutting iron windows and macking door there for passage for outdoor installation, fixing and provision for future maintenance purpose. Including charges of welding , masonary charges, labour charges and materials charges for sand ,cement , chipes etc.
Supply & Fiixing of indoor type LED SIGN Board i) 8'(L)x4'(B)x.5''(W) ii) 6(L)x4'(B)x.5''(W) fabricated from 3 mm thick ACP sheet on all five sides finished with approved metallic colour & suitable size hollow Al rectangular bar as frame inside the box. All LED Module, wiring to be fixed inside the ACP box. Silicon adhesives, SS screws to be used in such a way so that ingress of water can be restricted inside the box and maintenence / replacement of the LED modules can be done easily. All screws/nuts & bolts/clamps etc metals used inside the box should be of non-ferrous metal/Stainless steel.
SIZE-i)8'X4'=32 sqft.x2 (Front/back)=64.00 sqft ii)4'X0.5'=2.0 sqft x2(Top/bottom) =4.00 sqft iii)8'X0.5'=4.00 sqft X2 (Top/bottom) =8.00 sqft Total=76.00 sqft PEDIATRIC HDU DEPARTMENT OF UROLOGY NRS MC&H,KOLKATA-14
Supply & Fixing of Special type of 3D Boxing type letter(6" x 3.5") with top cover openable made from imported 3mm thick Acrylic sheet to accomodate LED module. Only front side of the letter should emit light. side to be made from opaque acrylic sheet. Letter height, width & depth of the letter will be proportionate & as per direction of E.I.C.. Suitable Ratio should be maintained between the letter size, spacing between each letters & spacing between each words as per the direction of the E.I.C. (Calculation of area (square inch) of a letter will be HeightXBreadth of the letter inclusive all wastage. ( letter 33 nos) i)8”x4”=32”Per letter x5 nos. letter=160 sq.inch*80%=128sq.inch II)8”x0.5”=4.00”Per letter x27 nos. letter=108.00 sq.inch*80%=87.00sq.inch Total-215.00 sq inch
Supply & Fixing of LED within the acrylic letter from backside (Make: SAMSUNG-Korea/ROHS) having the following specifications: COLOUR:WHITE or as per the choice of EIC. LIFE:70,000 burning hours. INTENSITY: Uniform without any bright/dark patches. VISIBILITY: 100Mtrs at least for normal eye vision. AMBIENT AIR: 0-50°C; 100% Relative Humidity. POWER CONSUMPTION: 1.5 Watt per module.
SITC of water proof 400 watt Power Supply unit to be fitted inside the Sign board box. inclusive of water tight gaskette fitted stainless steel hinged door box. Input: 100V-240V AC; 4A; 50Hz. Output: 12V DC; 17-20A constant power supply. Make: Meanwell/Ven/Resang or equivalent.
Supply & Fixing of structural type frame suitable for ACP fascia fixing of size (6" x4"x 2" ) to be made by 3mm thick 2" dia square pipe including necessary machining , welding and jointing materials.
Supply & Fixing extra supporting of structure by 3mm thick 1"x 1" square pipe of 6" & 4" length 4 nos each .
S & F of 26 SWG G.I. sheet for covering of back side of iron frame incl. fabrication charge.
Painting the MS structure with 2 coats of RO primer and one coat of synthetic enamel paint after scrapping the structure emery paper properly.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of through 20mm dia PVC rigid conduit pipe and by the prelaid GI fish wire and making necy. connection as required
3 x 22/0.3 (1.5 sqmm)
Transpotatation charges of the above mentioned board from Co's workshop to work site.
SITC UPS Topology:- IGBT BASED DSP CONTROLED (Make: Vertive/Power One)
Rating of UPS(KVA/KW): 10 KVA/8 KW
Input Frequency: 40 to 72 Hz
Input PF: .99 with IGBT Rectifier
Galvanic Isolation: UPS should have Isolation Transformer inbuilt(with 1:1 winding ratio) at the output
Back feed Protection: UPS should have back feed protection facilities
DC Ripple: Residual ripple Voltage should be <1%
Charging: Automatic float cum Boots Charging Capability with settable float & boots charging voltages and current levels and boots charger timer
Input current Distortion: Thai<=3%
Output Voltage Regulation: Static Variation +/_ 1% and Dynamic variation +/-3%
Output Frequency: 50 Hz +/- 0.1% in Free running & +/- 4% in Sync
Isolation Transformer: Inbuilt Isolation Transformer with 1:1 ratio at UPS output to be provided . No external/Step up Transformer will be accepted
Output Power Factor: 0.8(min.) to 0.9
Crest Factor: 3:1
Waveform: Pure Sine Wave
Bridge: Microprocessor based and IGBT Technology
Battery Cabinet: With power coated Battery cabinet with well air ventilation to ensure battery health using MS angle & MS sheet with battery interlink cables and necessary accessories.
Battery Voltage & VAH rating: 12 V, Mono Block batteries
DC Bus : Minimum 384V or above, 60 mim back up required VAH 16128 Battery.Paralling of batteries not allowed Battery Make: Exide/Amar Raja(Quanta)
Protections: Input & Output Over / Under Voltage, Single Phasing DC - High / Under Voltage, Battery Charging Over Current, Output Overload / Short Circuit / Over Temp., UPS auto ON on Mains recovery
Audio Alarm, Mains Fail, Battery Low Pre-alarm, Inverter Trip
Metering: Graphical LCD display for Input & Output - Voltage, Current & Frequency, Battery - Voltage & Current
Indications: Mains - On / Fail / High / Low / Single Phasing DC - On / High, Battery - Low Pre-alarm / Low Trip Inverter - On / Trip / High / Low / Over Current
Switchgear: MCB / MCCB for Input, Battery, Output & Manual Bypass Switch
Enclosure: IP 20
Operating Temp: 0 to 40 Deg C
Humidity: Up to 95% Rh (non-condensing)
Cooling: Forced Air
Noise: < 75 Db
Cold Start : Provided
Communication: RS 232
Monitoring Software: UPS Monitoring Software on Windows XP Platform
Configuration:UPS should be Parallel up to 6 units
Certification : ISO 9001: 2008, ISO 14001: 2004, ISO 18001, RoHS and OHSAS 18001 Certified.
IEC/EN 62040-1-1,IEC/EN50091-1,IEC/EN 60950 (Safety) IEC/EN 50091-2, IEC/EN 62040-2(EMC Emission),IEC/EN 62040-3(performance & Design)IEC/EN 61000-4(EMC Immunity) & IEC/EN 60146 (Design & Manufacture)
Standard Warranty: 2 years repair or replacement, Start-Up Service.
Certification : ISO 9001: 2008, ISO 14001: 2004, ISO 18001, RoHS and OHSAS 18001 Certified
IEC/EN 62040-1-1,IEC/EN50091-1,IEC/EN 60950 (Safety) IEC/EN 50091-2, IEC/EN 62040-2(EMC Emission),IEC/EN 62040-3(performance & Design)IEC/EN 61000-4(EMC Immunity) & IEC/EN 60146 (Design & Manufacture)
Standard Warranty: 2 years repair or replacement, Start-Up Service
SITC of wall mounted compartmenatalised L. T. Cubicle panel board made out of 16 SWG CRCA sheet with dust & vermin proof gasketted front open door with mechanical locking arrangement and to be fixed on wall b y means of 4nos. heavy duty M.S. bullet fastner. The board to be painted by powser coated paint includ-ing incorporating the following electrical accessories and making all necy. connections as per direction of E.I.C. (Approx. siz :900mm. X400mm. X 250mm) : - (a) 415V. 63A. 4-pole on load change over switch of open execu tion type [Make: L & T or similar specification of Legrand / Schneider]. ........................01 No. (b) Supplying and fixing 415 V 32A Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs and necessary connection [Make:L & T or similar specification of Legrand/ Schneider]..................01 No. (c) 100A. 4-pole M.S.stud connector..................................01 No.
Supplying and Drawing 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire (RR Kable/Finolex) of the following sizes in the PVC (40/50mm size) conduit pipe and by the prelaid GI fish wire and making necy. connection as required, as directed by EIC.
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
Finising the end of above PVC insulated & unsheathed copper wire.
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
Rate is inclusive all taxes and cess
Defect Libility Period 1 year
NAYEE DISHA PROJECTS (BID ID -5763107)
GITANJALI ELECTRONICS AND ELECTRICALS (BID ID -5796069)
M/S EASTERN ENGINEERING (BID ID -5795678)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .