Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Not Admitted-Fee/PreQual/Technical 0 MAIN ROAD MAIN ROAD MILAK RAMPUR UTTAR PRADESH 244901 | RAMPUR | UTTAR PRADESH | 244901 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹13.3 L
EMD Value
₹1.3 L
Closing Date
11 Dec 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DDEM MANDI PARISHAD BAREILLY
OFFICE OF DDEM MANDI PARISHAD BAREILLY
Internal Electrification work in B type shops 38 No, APF 01 No and lighting Arrangement at NMY Moradabad
2025_RKUMP_1092593_1
1155
Open Tender
Electrical Works
Percentage
MORADABAD
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,400
DDEM MANDI PARISHAD BAREILLY
₹1.3 L
Yes
12 Dec 2025
24 Nov 2025
12 Dec 2025
24 Nov 2025
11 Dec 2025
24 Nov 2025
Wiring point for light with 1.5 sqmm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sqmm FRLSH PVC insulated multistrand single core copper earthwire drawn inside, G.P. Box modular switch and ceiling rose/angle holder/batten holder complete in all respect, as directed, including color wash.
Wiring point for fan and light duty exhaust fan with 1.5 sqmm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sqmm FRLSH PVC insulated multistrand single core copper earthwire drawn inside, G.P. Box modular switch and ceiling rose/angle holder/batten holder complete in all respect, as directed, including color wash.
Wiring point for Plug with 1.5 sqmm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sqmm FRLSH PVC insulated multistrand single core copper earthwire drawn inside, G.P. Box modular switch and ceiling rose/angle holder/batten holder complete in all respect, as directed, including color wash.
S/B of safe earthing electrode T-19 (hot dip galvanized), length up to 2000mm, outer pipe 50mm, inner pipe 25mm, terminal dia 12mm, outer GI pipe of 16swg and inner pipe of 12swg with hot dip galvanization up to 100micron filled with crytalline conductive mixture (CCM) having anti corrosive & conductive property with 50kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square CI frame with hinged cover & masonry housing (from electrode terminal to switch board, cost of earth lead will be extra)
S/L of aluminim conductor PVC insulated armored, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by Engineer-In-Charge, complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc. 10sqmm 2core
S/F of one number 8 to 6 SWG G.I. Wire in 15mm dia. G.I. Pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand labour. T and P other material required for proper completion of the work as directed at site.
S/F surface/flush mounting 4 way SPN distribution board with additional metal door without MCB complete in all respect and as directed at site. Cat B
Supply and Fixing of surface/flush mounting 8 ways SPN distribution board with additional metal door without MCB complete in all respect, as directed by engineer-in-charge. CAT-A
S&F of 6 Amp to 32 Amp. MCB (10 KA) C Curve. CAT-A
S&F of 6 Amp. to 32 Amp. DP MCB (10 KA) C Curve. CAT-A
Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. required for proper completion of work.
Supply and fixing hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16 SWG MS sheet incorporating 10mm dia. M.S. round bar duly bent for supporting fan hanger duly painted with red oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work.
Supply and fixing of electronic fan regulator( Modular) 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work.
Supply and wiring of submain with two number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit with 1 number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor as earth continuity wire complete in all respects including matching colour wash complete in all respect.
Supply and fixing of water tight oblong 10 watt LED bulkhead luminaire having pressure die cast housing with driver set confirming to IP65 and above protection, complete in all respect, with 3 years warranty.
S/F of recess/surface mounting round 24 to 32 watt LED down lighter having powder coated die cast aluminium housing with extended heat sink, diffuser/reflector and driver set complete in all respects. CAT AA with 3 year warranty
Supply and wiring of submain with two number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) Steel conduit on surface with one number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor as earth continuity wire drawn inside the conduit
S/L of B class heavy 100mm dia GI Pipe on pole or road crossing complete in all respects
S/E of stay set at least 3.5 Meters away from the pole complete with galvanized 19 mm dia x 1.80 Meter long stay rod, 30cm x 30 cm x 6.3mm anchor plate, thimble stay clamps, stay insulator 19mmx600mm double screw tightener 7/3.15mm G.I. stay wire etc. in 1:3:6: cement concrete complete in all respects.
S/F of steel tubular pole 9.50 Meter long designated 410 SP-36 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respects.
S/F of 230mmx32mmx1.5mm galvanized steel strips including holes for shackle insulators pins and bolts etc. complete in all respects.
Supply and erection of ‘D’ clamps of 50mmx6mm flat iron on steel tubular poles/steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminum paint.
Painting of the electric pole with 2 coats of aluminum paint over red oxide primer complete in all respects.
S/F of LED Street Light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 110 to 130 watt confirming to IP 66 Protection having company logo engraved complete in all respects including labour Cat AAA, with 5 year warranty.
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
TENDERNOTICE.pdf
Tender Documents • 0.45 MB
BOQ_2009093.xls
BOQ • 0.27 MB
MORADABADT1.pdf
Additional Documents • 0.92 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .