Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.0 L+₹25,232.50 (0.85%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹30.1 L+₹30,911.70 (1.04%)Rejected-Finance NA | L3 | Rejected-Finance L3 | |
| 4 | L4₹34.5 L+₹4.8 L (16.0%)Rejected-Finance H NO 17036 9 STREET NO 5 A AGGARWAL COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance L4 | |
| 5 | L5₹35.9 L+₹6.1 L (20.4%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹37.4 L
EMD Value
₹74,800
Closing Date
21 Aug 2021, 6:00 pmClosed
Shri Niranjan Lal GE(S) BTD
GE(S) Bathinda Bathinda Mil Stn
SPECIAL REPAIR TO OTM ACCN BLDG NO P-08 AND SINGLE JCOS ACCN BLDG NO P-61 UNDER GE(S) AT MIL STN BATHINDA
2021_MES_452969_2
GE(S)BTD-24/2021-22
Open Tender
Civil Works
Item Rate
180 days
Bathinda Mil Stn
AS PER NIT
10 documents required · 10 mandatory
₹500
GE(S) Bathinda
₹74,800
Yes
30 Sept 2021
29 Jul 2021
24 Aug 2021
29 Jul 2021
21 Aug 2021
7 Aug 2021
Amount
Taking down chowkhats or frame n exc 1.50 Sqm each with shutters (W/out taking off shutters from the frames) complete all as specified and directed..
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4 Sqm each complete all as specified and directed..
Taking down shutters of any description exceeding 1.0 Sqm but not exceeding 2.0 Sqm each and removal from site complete all as specified and directed.
S & F in repair pressed steel shutter for cup board with sheet thickness not less than 1.6mm thick made to shape as per std drawing of CE BTZ-059 1(R)1 with and including locking arrangement, handle and one shop coat painting ete complete all as specified and directed..
S & F for pressed steel frames for doors with one or more rebates including hinges, lock strike plate, fixing lugs, etc., size of frame 125 x 60mm, complete all as specified and directed. (thickness of steel sheet shall be 1.25mm) Note:- The quoted rate deemed to include the cost of making good the disturbed surface with cement plaster 1:6. Nothing extra shall be paid on this account complete all as specified and directed.
S & F for pressed steel frames for doors with one or more rebates including hinges, lock strike plate, fixing lugs, etc., size of frame 75 x 60mm, complete all as specified and directed. (thickness of steel sheet shall be 1.25mm) Note:- The quoted rate deemed to include the cost of making good the disturbed surface with cement plaster 1:6. Nothing extra shall be paid on this account complete all as specified and directed..
S & F solid FRP door frame of size 100X60 mm with single rebate of 32mm x 15mm to receive shutter moulded with fire retardant grade and saturated polyster resin and choped mat door framed shall be 2mm thick and fill with suitable block in all the three legs the frame shall be covered wit hfiber glass rom all side MS stay shall be provided at the bottom to steady the frame as per specification shown on drawings complete all as specified and directed..
S & F in repair 18/19mm thick Particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work partical board, medium density, flat pressed, single layer type or three type with BWR type adhesive, fixed with screws to timber frame work complete all as specified and directed..
S & F for 2nd class hardwood, factory made shutters, 35 mm thick plain framed panelled shutters (any number of panels) with with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both side. The size of rail & stiles as per IS :1003 (Part I), kiln seasoned and chemically preassure treated, complete all as specified and directed..
S&F for 2nd class HW 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauge, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass, gauze, etc.; sizes of members of shutters as specified in SSR Part I Section 8, Clause 8.24 (a) complete all as specified and directed..
S & F for factory made solid panel shutter (PVC) 30mm thick (Style consisting of frame made out of MS tube for top and bottom rails MS frame shall be covered with heat molded plain colour PVC 'C' channal having a PVC sheet strip of 20mm width struk inside with solvent cement for styles and plain colour PVC sheet for top rail, lock rail and bottom rail on ei8ther side and as gap insert for top rail & bottom rail. panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and raols with suitable PVC sheet beading and jointed together with solvent cement as per specifications complete all as specified and directed..
S & F for factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with MS square tube fixed in opening complete as per specifications and making good the plaster of wall in CM 1:6 complete all as specified and directed..
S&F for factory made solid panel FRP door shutter shall be 30mm thick (style) glass fibre reinforced plastic panel door shutter of required colour with fire retardant grade and saturated polyster resin moulded to 3mm thick FRP lamimated for forming hollow rails and stupe with wodden frame and suitable block of seasoned wood inside at reqd place for fixing of fittings cast monolithically with 5mm thick FRP panel and confirming to IS-14856:2000 supplying and fixing in the frame at site as per drawings complete all as specified and directed..
S&F 100mm butt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type B-21 complete all as specified and directed
M & L for PCC 1:3:6 type C1 (20mm graded stone aggregates) as in filling back of chowkats complete all as specified and directed
M & L for 50mm thick PCC (1:3:6) type C-2, using 40 mm graded stone aggregates as in sub base under floors complete all as specified and directed.
M & L for sand filling under interlocking tiles and under cables including watering and consolidating complete all as specified and directed.
Material and Labour of 60 mm thickness machine pressed precast concrete interlocking tiles any shape, size and colour/ pattern(as approved) confirming to IS - 15658-2006 (Marked) of M-35 grade complete all as specified and directed .
S & F 'in repair' Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bars, dovetailed or welded, complete all as specified and directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete without glazing bars, dovetailed or welded, complete all as specified and directed.
S&F steel windows or ventilators fixed type with glazing bars complete all as specified and directed.
S&F 'in repair' steel windows or ventilators fixed type with glazing bars complete all as specified and directed.
S & F MS such as grills, guard bars including welding reveting etc complete all as specified and directed.
Hacking out old broken glass from metal frame of any thickness incl punching or drilling out old glazing pins/springs clips and providing and fixing for 4mm thick ordinary sheet glass and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and directed.
Hacking out old broken glass from metal frame of any thickness incl punching or drilling out old glazing pins/springs clips and providing and fixing for 4mm thick pin head glass and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and directed.
S & F (fixing with screws or welding as per site requirement) 300mm mild steel ordinary rat tail rod pattern springs (Helical Springs), including roller & roller plate complete all as specified and directed.
Supply and fixing mild steel barrel tower bolts, 200 mm long, stove enamelled black with bright bolts and fixed complete all as specified and directed.
Supply and fixing mild steel sliding door bolts with hasp and staple, length of bolt 250mm, plate type, stove enameled black, with bright bolts not less than 12 mm dia with and including a minimum of 6 bolts and nuts, 4 on bolt plate and 2 on staple plate and fixed, complete all as specified and directed.
Supply and fixing mild steel pressed handles, 125 mm long, oval type, stove enamelled black complete all as specified and directed.
S&F for aluminum anodised barrel tower bolt 150mm long of extruded section complete all as specified and directed.
S&F for aluminium handles cast type anodised 125mm long for cupboard and doors complete all as specified and directed.
S&F for aluminium hasp and staple 100mm size complete all as specified and directed.
Taking down cement plaster incl terrazo finishe etc. including raking out joints, hacking for key and scrubbing down with water complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or conc surfaces in CM (1:6) finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or conc surfaces in CM (1:4) finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick on ceiling surfaces in CM (1:3) finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparing surfaces steel and iron work, new or old of any descriptions and girth not otherwise described and treated with tar or coaltar for black paint complete all as specified and directed.
M&L for prepration of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified.
M&L for prepration of old steel surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint on existing steel surface complete all as specified and directed.
M & L for applying one coats of synthetic enamel paint on wood and wood based surfaces of any description, over 10cm width or girth, not other wise described including preparation of old painted surfaces complete all as specified and directed.
M&L one coat of white wash on plastered/ unplastered surfaces of existing ceiling incl preparation of surfaces complete all as specified and directed.
M&L three coats of white wash on newly plastered surfaces of ceiling incl preparation of surfaces complete all as specified and directed.
M&L applying three coat of white wash on prepared surfaces of new plastered surfaces of wall including preparation etc complete all as specified and directed.
M&L for applying two coat of white wash on old plastered surfaces of wall including preparation complete all as specified and directed.
Complete removal of existing treatment on Old internal wall surfacees of any desciption, preperation of surface by Mechanised sander having suction vaccum Bag using smart periodical methodology, complete all as specified and directed. and applying the following:- (a) Applying wall care putty in two coats on wall surface and smoothing the surface with sand papers/ Mechanised sanding etc prepatory to paint complete all as specified and directed. (b) Two coat of Oil Bound distamper of approved tint over a coat of primer on old prepared surface by using Airless spray/ roller over complete all as specified and directed.. Note:- Contractor may use manual scraping tools for complete removal and surface prepration with prior approval of Engr-in-chrge in case of using Mechanical equiment are not posible.
Preparation of new plastered internal wall surface complete all as specified and directed. applying the following :- (a) Applying wall care putty in two coats on wall surface and smoothening the surface with sand paper/ mechanised sander etc prepatory to paint complete all as specified and directed. (b) Two coat of oil Bound distemper over a coat of chalk whiting priming by using Airless spray/ roller over complete all as specified and directed. Note:- Contractor may use manual scraping tools for complele removal and surface prepration with prior approval of Engr-in-Charge in case of using of Mechanical equipment are not possible.
Preparation of new external plastered wall surface complete all as specified and directed. applying the following :- (a) Applying wall care putty in two coats on wall surface and smoothening the surface with sand paper/ mechanised sander etc prepatory to paint complete all as specified and directed. (b) Two coat of exterior acylic emulsion by using Airless spray/ roller over complete all as specified and directed. Note:- Contractor may use manual scraping tools for complele removal and surface prepration with prior approval of Engr-in-Charge in case of using of Mechanical equipment are not possible.
Complete removal of existing treatment including filling depression of scraped surface with wall putty two coats 1.5 mm thick each on old external wall surfaces of any desciption, prepration of surface by Mechanised sander having suction vaccum Bag using Smart periodical methodlogy, complete all as specified and directed. and applying the following:- (a) Two coat of exterior acylic emulsion by using Airless spray/ roller over complete all as specified and directed.. Note:- Contractor may use manual scraping tools for complete removal and surface prepration with prior approval of Engr-in-chrge in case of using Mechanical equiment are not posible.
M&L for preparing newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for two coats of cement based paint over a coat of alkali resistant primer on old plastered surface of wall including complete removal of existing treatment of old surface of wall complete all as specified and directed.
M&L applying 3mm thick wall care putty in two layers on wall complete all as specified and directed.
M&L for two coats of oil bound distemper over a coat of suitable primer on walls incl complete removal of existing treatment of old surfaces of wall complete all as specified and directed.
M&L for two coats of oil bound distemper over a coat of suitable primer on walls incl preparation new plastered surface of walls complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection surface fnished even & smooth without using extra cement complete all as specified and directed.
Demolition in concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
Water proofing treatment to sunken slab and adjoining vertical surfaces as specified under:- (a) M&L rendering 10mm thick in cement plaster(1:3) using coarse sand mixed with integral water proofing compound trowel even and smooth with steel trowel on sunken surfaces. (Note : WPC shall be measured and paid separately). (b) Applying first coat of chemical pidifin 2K(Dr Fixit) o cleared RCC surfaces @ 0.86 Kg/sqm (minimum) as recommed by manufacturers. (c) Provide a layer of glass fiber mesh sixe 2.25mm x 2.25mm (45 GSM) over first coat of chemical pidifin 2K as per manufacturer recommendation. (d) Applying second coat of chemical pidifin 2K (dr Fixit) @ 0.86 Kg/Sqm (minimum) over layer of glass fibre mesh of size 2.25mm x 2.25mm (45 GSM) as recommended by manufacturer's.
M&L PCC 1:5:10, type E-2 as in filling of sunken floors complete all as specified and directed.
S&F in repairs vitreous china squatting pan "ORISSA" pattern size 580 x 440mm white with integral foot rests complete all as specified and directed.
S&F in repairs vitreous china wash down water closet pam (pedestal pattern) white, including connection to drain (or outgoing pipe) and to flushing pipe, anti syphonage pipe etc. complete all as specified and directed.
S&F in repairs PVC low level cistern 10 Ltr cap with inlet ball valve float and handle incl bracket and PVC flushing pipe 32mm dia 90 cm long (colour white) complete all as specified and directed.
S&F in repairs PVC connections 450mm long incl brass nut and washers on both ends complete all as specified and directed.
S & F in repairs 15 mm bore chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S & F 15mm dia basin mixture cast copper alloy chormium plated single lever without pop-up waste, 450mm braided houses with capstain head hoigh pressure with long excrude nshanks and flynuts extrude for iron pipes etc complete all as specified and directed. Make:- Jaquar Model No- ARI39001B or any equivalent make from the list of makes attached in tender documents as approved by GE
S & F in repairs 15mm bore chromium plated fancy type stop valves cast copper allay, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipes complete all as specified and directed.
S & F in repairs 15mm bore chromium plated concealed type stop valves cast copper allay, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipes complete all as specified and directed.
Taking down or up GI tubing 15mm bore etc complete all as specified and directed.
Taking down or up GI tubing 20mm bore etc complete all as specified and directed.
Refixing 15mm bore old steel tubing and connections in new or old positing including cleaning (wall, celling, floor etc) complete all as specified and directed. .
Refixing 20mm bore old steel tubing and connections in new or old positing including cleaning (wall, celling, floor etc) complete all as specified and directed. .
S&F GI tubing 15mm bore medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
S&F GI tubing 20mm bore medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
Taking down rain water pipe any size incl all fittings complete all as specified and directed.
S&F PVC 110 mm bore pipes 4.0 Kg/Sqcm single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC bends 110 mm bore any radius complete all as specified and directed.
S & F in repair Chromium plated 125 mm long shower rose with or without swivel joints, any size, incl fixing to steel pipe or union as complete all as specified and directed.
Dismantling water tanks of capacity 500 ltr and n. exc 1000 ltr and removing complete all as specified and directed.
S&F PVC water tank 500 Ltrs including 20mm bore PTMT float valve rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
S&F PVC water tank 1000 Ltrs including 20mm bore PTMT float valve rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for PCC (1:2:4) type B-1, 25mm thick as in floors finished even and fair complete all as specified and directed.
M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), terrazo dado/wall tiling and skirting. etc on brick or stone walls etc including racking out joints hacking for key and scrubbing removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed. .
S&F glazed ceramic coloured tiles in vetical surfaces size 300x450x7mm thick, over & including 10mm thick screed in CM 1:4 set and jointed in neat cement slurry and pointed in white/coloured cement to match complete all as specified and directed.
S&F non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm in floors, over and including 15mm thick screed in CM (1:4) set and jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed. .
M & L for non-skid coloured ceramic tiles 7 to 8mm thick (square / rectangular), area of each tiles exc 0.18 Sqm but not exc 0.38 Sqm in skirtings set and jointed in neat cement slurry and pointed in white cement with pigment or coloured cement to match the shade of tiles over and including 10 mm thick rendring plaster in CM (1:4) complete all as specified and directed. .
M & L for non-skid coloured ceramic tiles 7 to 8mm thick (square / rectangular), area of each tiles exc 0.18 Sqm but not exc 0.38 Sqm in floors etc set and jointed in neat cement slurry and pointed in white cement with pigment or coloured cement to match the shade of tiles over and including 15 mm thick rendring plaster in CM (1:4) complete all as specified and directed. .
S&F in repair drapery rod of dia not less than 25mm duly powder coated of shade as decided by Engr-in-Charge including ABS plastic finials of approved shade and including standard MS poder coated brackets fixed to walls with rawl plugs and steel screws complete all as specified and directed. .
S&F in repair brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and directed.
S&F in repair chromium plated towel ring complete all as specified and directed.
S & F in repair fancy type corner glass shelf 30cm with ABS/CP brass bracket and SS/CP brass railing etc complete all as specified and directed.
Dismantling and disconnecting of existing CI soil vent pipe 100 mm bore fixed to wall,laid in trenches incl all fittings & accessories complete all as specified and directed.
Dismantling and disconnecting of existing CI soil vent pipe 75 mm bore fixed to wall,laid in trenches incl all fittings & accessories complete all as specified and directed.
S&F 100mm dia Cast Iron soil waste & vent pipes in any length with or without ears, with cement joints laid in trenches or in floors complete all as specified and directed.
S&F 100mm dia Cast Iron soil waste & vent pipes in any length with or without ears, with cement joints but fixed to walls with & including fixing clamps complete all as specified and directed.
S&F 75mm dia Cast Iron soil waste & vent pipes in any length with or without ears, with cement joints laid in trenches or in floors complete all as specified and directed.
S&F 75mm dia Cast Iron soil waste & vent pipes in any length with or without ears, with cement joints but fixed to walls with & including fixing clamps complete all as specified and directed.
S&F in repairs 75mm dia branch piece single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified and directed. .
S&F in repair 100 mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified and directed.
S&F in repairs 100mm CI connection socket to fit out let of WC complete all as specified and directed.
S&F in repair CI Cowls 100 mm complete all as specified and directed.
M&L in repairs CI floor trap 75mm with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
Dismantling boarding any description fixed in any posistion with rails including fillets complete all as specified and directed.
S & F fillets, second class hardwood square, rectangular in section, clean sawn, secured with nails or brads and area exc 3 sq cm but not exc 6 sq cm, complete all as specified and directed. .
Cutting holes in brick walls built in cement mortar including making good dismantled portion in CM (1:3) or cement concrete (1:2:4) type B-1 exc half brick but n.exc one brick complete all as specified and directed. .
M & L MS work as in framed brackets of angles as sink brackets and cooler stand complete all as specified and directed. .
Dismantling of brick tiles or terracing tiles single layer on roof and disposal off retrieved material upto a distance of 100m where complete all as specified and directed. .
Demolition of mud in roof any thickness including plastering and leeping and disposal of rubbish upto a distance n.exc 100m where complete all as specified and directed.
M&L for wire brushing and cleaning top sufaces roof slabs etc including washing the roof surface with water and making the surfaces free from mud etc complete all as specified and directed.
M&L rendering 15mm thick (avg thickenss) on roof surface including flashing and junctions of parapets etc finished even and fair in CM 1:3 mixing with WPC as per recommended ratio after brushing cement slurry @ 1.2 Kg/Sqm all as specified (WPC to be measured and paid separately) complete all as specified and directed.
M & L for APP based polymeric membrane mimimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid on primed surface by forced application as treatment(for moderate conditions) including after applying bituminous primer @ 0.5 Lt/Sqm over RCC/plastered roof surface and flashing etc complete all as specified and directed.
M & L cutting groves in brick wall 75mm wide and 65mm deep and shaping horixontal face of groove with cement motor 1:3 etc complete all as specified and directed.
M&L for lime concrete using 40mm thick brick aggregate laid to slope as directed by Engineer-in-Charge over RCC roof as padding complete all as specified and directed. .
M&L 40mm thick brick tiles bedded in cement mortar (1:6) 15mm thick and joints grouted and flush pointed in CM 1:3 mixed with water proofing compoung by weight of cement complete all as specified and directed. .
M&L 40mm thick brick tiles bedded in cement mortar (1:6) 15mm thick and joints grouted and flush pointed in CM 1:3 mixed with water proofing compound by weight of cement but except brick tiles complete all as specified and directed.
M & L for benching with PCC (1:2:4) type B0 using WPC along side wall adjoining to roof in concave shape complete all as specified and directed. .
Demolition of RCC of any descrition such as Kitchen chimniy, chajja, shelves, OHT Tanks. etc and in any position not other wise specially provided for complete all as specified and directed (reinforcement cut as required to facilitate demolition)
M&L for RCC type B-1, 1:2:4 (20 mm graded aggregate ) as in slab supported on walls, beams and column in floors, roofs, landing, balconies, deck slabs and in shelves and etc and setting in mortar complete with joints to match complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Use and waste of form work to rough finished surfaces of soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick complete all as specified and directed.
Demolition of brick work of any type built in cement mortor in foul condition etc complete all as specified and directed.
M&L for brick work built in cement and sand mortar 1:6 with sub class 'B' old size bricks straight or curved on plan exceeding 6m means radius complete all as specified and directed.
S&F in repair PTMT mirror cabinet of size 380 x 450mm best quality conforming to sample kept in GE office etc complete all as specified and directed.
S&F in repairs oval shaped wash hand basin of size 450 x 300 mm vitreous China white flat back/corner type including brackets, waste coupling & PVC waste pipe of 32 mm dia complete all as specified and directed.
S&F in repairs chromium plated pillar tap fancy type cast copper alloy of 15 mm bore, screwed down high pressure for iron pipe complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in floors,apron etc laid bedded and pointed in any mortar complete all as specified and directed.
Material and labour for machine cut kota stone slab flooring 20-25mm thick over 20mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completecomplete all as specified and directed .
Material and labour for kota stone slab 20 to 25 mm thick in riser of steps, skirting, dado rendering 20 mm thick screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M & L for 18 to 20mm thick morble work of any shade (table rubbed and polished) of approved colour and shade in steps, jambs, pillars, window cills, cooking platforms, counter for wash basins and the like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to with shade of slab, laid over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed.
S&F in repair Stainless steel fancy type peg set of four and fixed in position with steel screws complete all as specified and directed.
S&F in repair chromium plated soap tray of size 160 x 160 mm x 1mm thick and fixed to plugs on wall with chromium plated brass screws complete all as specified and directed.
S&F in repair Vitreous China urinals bowl urinal flat back size of 465 x 355 x 255 mm white(minium),complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement : fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe excluding flushing cistern, flush pipe and waste pipe, complete all as specified and directed. .
M & L or antitermite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 liters per liner meter including drilling and plugging holes etc in apron/plinth etc complete all as specified and directed. .
M & L for chemical emulsion for of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilles holes at 45 degree and replugging them with cement motor 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
m & L for treatment of soil under existing floors using emulsion @ one liter hole, 300mm apart including drilling and plugging 12mm dia holes with cement motar 1:2(1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
M & L for applying two coats of synthetic enamel paint over a coat of primer on wood and wood based surfaces of any description, over 10cm witdh or girth, not otherwise described including preparation of new surfaces complete all as specified and directed.
Supply only integral water proofing material, ISI marked complete all as specified and directed.
S & F in repair toilet paper holder recessed type stainless steel complete all as specified and directed.
S & F in Repair health faucet brass body with wall hook and 1 mtr SS pipe complete all as specified and directed.
Taking down carefully to existing copper point wiring (light,fan, socket or power) complete including fittings such as switches, ceiling roses, pendents, regulators sockets, light fitting etc removiing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
M&L for point wiring for one light/ceiling fan controlled by one switch with 1.5 sqmm (nominal area) PVC insulated and PVC unsheathed multi stranded copper conductor cable FRLSH in and including concealed PVC conduit 20 mm dia medium duty ISI marked, steel sunken boxes, 3mm thick laminated sheet cover, flush to surface for one light point , fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 sqmm copper conductor cable FRLSH connected to common earth dolly complete including cutting, chasing the surface and then making good the same in CM 1:3 complete all as specified and directed .
All as per item No 143 above but socket 3 pin 5 Amp 230 volt flush type on same board complete all as specified and directed.
All as per item No 143 here in before but for one socket point out let 3 pin 5 Amp in independent board.
All as per item No 143 here in before but for one socket out let 3 pin 15 Amp with 2.5 sqmm PVC copper conductor and 2.5 sq mm PVC insulated copper conductor as earth contiuity conductor.
All as per item No 143 , here in before but for one light point controlled by two 2-way
Supplying & fixing for switch paino flush type, 5 Amps, single pole, two way , 230 volts AC circuit complete all as specified & directed
Supplying & fixing switch piano flush type 5 Amp 230V AC complete one way complete all as specified and directed.
Supplying & fixing socket 5 PIN 5 Amp flush type 230volts AC complete all as specified and directed. (Switch and socket shall be the same make)
Supplying & fixing one switch and one socket 5 PIN 15 Amp 230volts AC complete all as specified and directed. (Switch and socket shall be the same make).
Supplying & fixing regulator for ceiling fan electronic step type suitable for 1200/1400mm ceiling fan complete all as specified and directed.
Supplying & fixing ceiling rose surface type bakelite 65x50mm two to three terminal 230V complete all as specified and directed.
Supplying & fixing wall mounted LED batten fitting 1X10 watt, 6500K, 2 ft complete with decorative ultra slim square profile LED lighting fixture with extruded polycarbonate enviroment friendly, energy efficient complete with all light fittings connection complete all as specified and directed.
S&F Lamp holder PVC/Polycarbonate type with back plate complete all as specified and directed.
S&F 9w LED Bulb complete all as specified and directed.
Supply and fixing double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting SPN, 8 way, 230 Volt, with 200 Amp rated bus bar suitable for fixing MCBs, isolators etc including taking down old complete all as specified and directed.
All as per Srl item No. 157 but,TPN 4 way, complete all as specified and directed.
S&F MCB 230V 40-63 Amp DP complete all as specified and directed.
S&F MCB 230V 32-40 Amp DP complete all as specified and directed.
S & F MCB 6 Amp to 32 Amp SP 10 KA ‘C’ series complete all as specified and directed.
S&F blanking plate etc complete all as specified and directed
S&F sub main two single core PVC copper conductor unsheathed wire multi stranded 6 sqmm including cutting chasing and grouting PVC pipe including Tee, Elbow, Bend etc and including 6.0 sqmm copper conductor single core wire connected by common earth all as specified. Including 20 mm dia PVC conduit, medium grade, ISI marked. complete all as specified and directed. (Note :- two lengths of 6 sqmm cable and one length of 4 sqmm cable will be measured as one length) .
M&L for earthing with galvanized steel earth plate electrode 600x600x6mm size burried directly in ground to depth not less than 2.25m below ground level with top edge of the plate not less than 1.5 mtr below normal ground level surrounded with char coal and common salt filling in alternative layers of 15cm thick and connected to GI earth wire 4mm dia by means of nuts/bolts and washers etc made out of galvanized iron including 15mm dia GI pipe light grade for protection of earth wire from earth to distribution board 20mm dia GI pipe medium grade connected to funnel heavy wire mesh for watering purpose including necessary excavation and earth work PCC (1:2:4) type B1 for contrite pit 10mm thick PCC slab cover frame all as specified and shown in electric plate Nos 3/ SSR Pt-I and testing on completion including old replacement of old testing complete all as specified and directed.
Taking down existing unserviceable exhaust fan and supply and fixing heavy duty exhaust fan 300mm sweep single phase 230 Volts, 50 Hz, 1400 RPM with louvers complete all as specified and directed
S&F wall mounted extruded Aluminum/polycarbonate LED batten fixture T8 (G13 holder) 1.2m, including one LED retrofit tube 20 watt, 1.2m T8 6500K, extruded Aluminium/polycarbonate, PC diffusor and inbuilt driver complete including making connection. The system wattage of fitting should not be more than 20 watt + 10%, surge protection of minium 3.5KV, power factor should be not less than 0.95 cool white colour, lumen output should not be less than 2000 lumens, input voltage range 140-280V AC, 6000 K complete all as specified and directed
S&F LED Bulk head fitting energy saving new generation 10 W LED IP65 with opal diffuser including lamp 10 W LED 6000K providing all electrical connection complete all as specified and directed
Supply and fix MCB tripole pole & neutral (TPN),63-100 Amps, 240 volts, 10KA, ‘C’ series, with all incoming/outgoing connections with proper size lugs including taking down old unserviceable one complete all as specified & as directed
Taking down serviceable/unserviceable ceiling fans 1200mm/1400 mm sweep 230 V, AC, single phase from qtrs, dismantling the ceiling fan and taking out complete rewinding (if unserviceable) the same with super enameled copper winding wire of existing gauge & size including throughly cleaning all the components of fan, oiling varnishing the fan with and including replacement of rusted/unserviceable nuts, bolts, split pin, rubber reel, flexible twin core copper cable of size 23/.00076 approximate one metre long for each fan, machine screws and painting the fans etc, and refixing the repaired fan to respective qtrs complete all as specified and directed. .
S&F LED light fitting, 1X45 watts complete with toughened glass IP66 with provn of suitable size GI bracket (01 No) and MS clamps (02 Nos) fixed to wall/ column including electrical connection providing 1.5 mtr long twin core round copper conductor cable of suitable size incl taking out old unsv complete all as specified and directed.
S&F LED light fitting, 1X25 watts complete with toughened glass IP66 with provn of suitable size GI bracket (01 No) and MS clamps (02 Nos) fixed to wall/ column including electrical connection providing 1.5 mtr long twin core round copper conductor cable of suitable size incl taking out old unsv complete all as specified and directed.
Taking down serviceable/unserviceable Exhaust fans 300/350/400 mm Sweep single phase 230 V 50 Hz ,1400 RPM complete with loures , AC, single phase from otm, dismantling the exhaust fan and taking out complete rewinding (if unserviceable) the same with super enameled copper winding wire of existing gauge & size including throughly cleaning all the components of fan, oiling varnishing the fan with and including replacement of rusted/unserviceable nuts, bolts, split pin, rubber reel, flexible twin core copper cable of size 23/.00076 approximate one metre long for each fan, machine screws and painting the fans etc, and refixing the repaired fan to respective otm complete all as specified and directed.
NOTE: If at site any nos of geyser , ceiling fan , exhaust fan, electric meter is found before starting the work , The contractor should hand over these items to Unit Rep in writing to avoid the last minute complicacies and refixing of electric meter is the sole responsibility of the contractor before handing over the site to user.
Note:- Net contract sum shall be calculated after deduction of Sch of credit on Srl Page No. 40(R) & 41(R) for amounting to Rs. 85873.00.
M/S VIAJY BUILDERS & DEVELOPERS
M/s Vandana Builders
M/s MITTAL CONSTRUCTIONS
M/s Nuway Constructors India Pvt. Ltd.
M/s Balvinder Singh Engineer and Contractors
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .