Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.4 LAccepted-AOC SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹44.6 L+₹37,245.86 (0.84%)Rejected-Finance | L2 | Rejected-Finance Being Not lowest | |
| 3 | L3₹45.5 L+₹1.3 L (2.94%)Rejected-Finance | L3 | Rejected-Finance Being Not lowest | |
| 4 | L4₹47.7 L+₹3.5 L (7.99%)Rejected-Finance | L4 | Rejected-Finance Being Not lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Below eligible class Documents for having present work load not uploaded and also not submitted. |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
29 Jun 2021, 6:00 pmClosed
GE MCEME SECUNDERABAD
GE MCEME Secunderabad MCEME Campus, Trimulgherry (Post) Secunderabad - 500 015
SPECIAL REPAIRS TO BLDG NO E2 TES BLOCK OF FDE UNDER GE MCEME SECUNDERABAD
2021_MES_447665_1
GE/MCEME/TOK-14 OF 21-22
Open Tender
Civil Works
Item Rate
180 days
Secunderabad
Class D Category a(I)
7 documents required · 7 mandatory
₹500
GE MCEME SECUNDERABAD
₹98,000
Yes
5 Aug 2021
2 Jun 2021
1 Jul 2021
2 Jun 2021
29 Jun 2021
16 Jun 2021
Amount
Dismantling Asbestos cement (corrugated semicorrugated) sheet in roof coverings complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
Ditto as per Item No. 2 above but in fillets rails posts , purlines etc under 40 sq. cm in section complete all as specified and directed.
Dismantling Wall & ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
M & L pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of approved colour having tensile strength of 550 Mpa as in roof covering / cladding to wall ,fixed with self tapping screw complete all as specified and directed.
M & L pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutters, fixed with self tapping screw complete all as specified and directed.
S&F Anodised aluminium snap grid frame work for false ceiling all as specified 605 x 605mm and Hangers 6 mm dia. G.I. wire (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
S&F in repairs PVC laminated designed (one side pvc lamination and other side aluminium paper) gypsum board 600 X 600 X 8mm thick decorative type fixed in aluminium frame work with screws or nails etc complete all as specified and as directed by Engineer-in-Charge.
S&F Mild Steel Rolled sections as in main and cross beams, hip and jack rafters; purlins here connected to common rafters and running rails and guides for sliding doors;fixed with angle cleats or other connecting plates quality conforming to Fe 410W(Gde-250) complete all as specified and directed by Engineer in harge.
S&F for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; complete all as specified and directed.
S&F 180 mm dia of PVC(SWR) pipes of 6 kg/ sqcm pressure rating , half round ready made eave gutter of approved make including necessary fitting like bend WC/ MS clips ETC complete all as specified and directed.
S&F 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls incl taking down old pipes complete all as specified and directed.
S&F 110mm PVC (SWR) bend any radius and all as specified and directed by Engineer in Charge
Demolition of brick work of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in 1:4 complete all as specified and directed.
Taking down plastering in cement mortar on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc. complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work in CM 1:4 finished even and smooth with using water proofing compound @3% without using extra cement. (Note : WPC will be measured separately) complete all as specified and directed.
Supplying only Integral waterproofing compound complete all as specified and directed.
M&L for applying two coats of Oil Bound Distemper over a coat of primer over 3mm wall care putty finished including preparing the new plastered wall surfaces complete all as directed by Engr-in-charge
M&L for complete removal of existing surfaces and applying two coats of oil bound distemper over a coat of alkali resisitant primer and one coat ( 2mm thick) wall care putty complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic mulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces and one coat 3mm external wall care putty finish including preparing the new plastered wall surfaces complete all as specified and directed.
Material & Labour for complete removal of existing surfaces and for applying Two or more coats of 100% Premium acrylic mulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces and one coat 3mm external wall care putty finish complete all as specified and directed.
M&L for two coats of synthetic enamel paint over a coat of red oxed primer including preparation of new steel surface of any description over 10 cm width and girth complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from the frames ) not exceeding 1.5 Sqm each complete all as apecified
Taking down chowkats or frames with shutters (without taking off shutter from the frames ) exceeding 1.5 Sqm each but n.exc. 4 sqm each complete all as apecified
S&F Windows/ ventilators (NCL ECO – 4000 Series Windows (Double Rebate Windows) or equivalent) fabricated from roll framed sections made of galvanized steel colour coated/ powder coated (Base steel as per IS 513 “D” quality galvanized as per IS 277 with zinc of 120 gms/Sqr. Mtr.) with total coated thickness of 0.58mm.Sections for Frame should be of 72mm x 55mm, Section for Mullion should be of 72mm x 50mm, Section for Shutter Frame should be of 47mm x 20mm, Section for Fixed Glass Bead should be of 12mm x 12mm, and Section for Fly Mesh should be of 40mm x 20mm Section for Frame Glazed Shutters and Mesh Shutters should be cut to length and miter joined with Polypropylene Corner Brackets, Mullion Section should be joined with Frame/Mullion using Mullion Cap Ethyl Propylene Damien Monomer (EPDM) Gasket should be used all around glass in shutter and Fixed Glass. Spoon Section should be used around Fly mesh to fix Mesh in Mesh Shutter including SS Pivot Hinges – 1 set, Seccolor Handle & Seccolor Stay and 4MM Plain Float Glass and Stainless Steel 32 gauge Fly mesh of 25 holes per SqCM and powder coated Grill made of 10mm sq. MS Bars welded at 150mm c/c, 6mm x 12mm MS flat and fixed to window frame with screws complete all as specified and directed.
M&L Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M S Square tube, supplying and fixing in opening as per manufacturers instructions complete all as specified and directed.
Material and Labour Factory made solid panel laminated PVC door shutter 30mm thick (style) consisting of frame made out M.S tube for top & bottom rails. M.S Frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/scaled the stiles & rails with suitalble PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specifications & drawing complete all as specified and directed.
S&F pressed steel frames for doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc of size 105 x 60 mm complete all as specified and directed.
M&L for 30mm thick flush shutter,(single panel or double panel)solid core construction with block board core and plywood face panels,commercials type on both sides face covered with decorative face veneer complete all as specified and directeb by Engineer in Charge
S&F MS flat iron as in hold fasts and similar articles confirming to grade Fe- 310-0 complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20mm graded aggregate) as in hold fast block including necessary form work etc complete all as specified and as directed
S&F 100 mm long Stainless Steel butt hinges medium weight cold rolled and mild steel hinge pin complete all as specified and directed.
S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F extruded aluminium anodised handle 125 mm fabricated type polished and fixed complete all as specified and directed.
M&L for 200 mm Aluminium anodised barrel tower bolts of extruded section rolled all complete all as specified and directed.
S&F Aluminium ( Die cast ) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg fixed complete all as specified and directed by Engineer in charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing srviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for 40mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as a levelling course complete all as specified and directed.
M&L for coloured Joint free Anti-skid Rectified Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for 15 mm thick screed bed or bedding layer of mortar in cement mortar 1:6 for lying floor finishes complete all as specified and directed.
M&L for coloured Joint free Anti-skid rectified Ceramic tiles 7 to 8 mm thick in skirting/ dado laid . set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for coloured non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile n.exc 0.18 sqm, in floors etc set and jointed in neat cement slurry in floors and pointed with coloured cement to match the colour of tiles complete all as specified and as directed by Engineer -in-Charge.
M&L for rendering 10mm thick in cement mortar 1:3 finished rough to receive wall tiles etc complete all as specified and directed.
M&L for Glazed ceramic tiles 450mmx300mx7mm thick on vertical surfaces such as dados, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat in CM 1:3 complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed by Engineer in Charge
M & L 100 mm thick PCC type C-2, 1:3:6 (40mm graded aggregate) as in hard standing, finished even and smooth with out using extra cement complete all as specified and directed.
M&L for Machine pressed precast conctete interlocking paver block fixed with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in copings around the paver block for setting etc including weathering, slightly rounded or chamfered angles and throating and including necessary form work complete all as specified and as directed.
S&F Vitreous china Squatting pan Orissa pattern of size 580mx440mm wite with integral foot rests (excluding flushing cistern and flush pipe) complete including concrete bedding & 'P' traps as required in repairs complete all as specified and directed.
S&F in repair viterous china wash down closet pan (pedestal pattern) including connection to drain and flushing pipe etc and plastic seat cover complete all as specified and directed.
S&F PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe in repairs complete all as specified and directed.
S&F Tubes, ‘Medium grade’ galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors of 15mm bore complete all as specified and directed.
S&F wash hand basin in repair Vitreous china white flat back size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets in repairs complete all as specified and directed.
S&F Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc., Bore of pipes in 32mm, etc completed all as spd and directed.
S&F 15mm dia Pillar taps fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F 15mm bore Bib tap fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
S&F 15mm dia brass Stop valves screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed 15mm bore complete all as specified and directed.
S&F in repair Vitreous China Urinal, Half stall type, white all as specified including flushing pipe and waste pipe in repairs complete all as specified and directed.
S&F in Chromium Plated 15mm, stop valves/ angle cock (Push type), cast copper alloy with crutch or butterfly handle, screwed down, high pressure, screwed both ends for iron pipe for urinals complete all as specified and directed.
S&F hand shower (Health faucet) (ABS Body) with 15mm dia, 1.2m long flexible tube & wall hook complete all as specified and directed.
M&L PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repairs, PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part-I 1000 Ltrs capacity including all fittings complete all as specified and directed.
S&F Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
Grubbing up tree trunk of girth exc 30 cm n exc 100 cm including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site complete all as specified and directed.
Excavation in trenches not exc. 1.5 mtr wide and n.exc. 1.5 mtr in depth for foundations, manholes, laying of sewage lines etc., n.exc. 10Sqm on plan and getting out in hard/dense soil complete all as specified and as directed by Engineer-in-Charge.
Demolition and breaking up of drain pipes (Salt glazed ware, AC or Reinforced concrete) of 200mm internal dia set in cement mortar complete all as specified and as directed.
M & L RCC drain pipes of 150 mm bore, class NP2, with collars laid and jointed, laid in tenches and jointed in CM 1:1 complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in copings, benching for manholes, haunching around manhole frame for setting etc including weathering, slightly rounded or chamfered angles and throating and including necessary form work complete all as specified and as directed.
M&L for precast cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate), as in man holes cover slabs etc including necessary form work and set in CM 1:6, complete all as specified and as directed. Note:- Reinforcement will be measured and paid seperately
M&L for Mild steel TMT bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Removal of excavated surplus soil to a distance not exc 50m away and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed.
Cutting into existing manholes for connecting new 150mm drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 200/225mm dia pipe complete all as specified and as directed.
Pumping out sewage water / sludges from Septic Tanks / Soak Wells / Sumps etc., of any size / dia by means of mechanical operated equipment / trolley mounted Browsers duly taking all precautionary measures and removing sludge / water out side and away from the MD land (working on foul condition) complete all as specified and directed.
S&F Ball brass valves 25mm bore, high pressure, with polythene float & flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / Hylam sheet/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified.
Material and labour for concealed point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked of suitable dia conduit wiring in walls/PVC conduit on wall including Tee, Junction boxes and provision of 2.0mm thick MS terminal boxes duly painted with red oxide metal primer and covered with 3 mm thick sheet cover of suitable size including suitable screws with washer for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to common earth dolly complete all as specified & as directed for One light point controlled by one, one way switch 5 amps, SP Note:- Cutting and chasing will be measured and paid seperately.
All as per item No. 82 above but for One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator
All as per item No. 82 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per item No. 82 above but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No. 82 above but using 2.5 Sqmm single core copper conductor cable multistranded PVC insulated unsheathed 1100 volts grade for 3 pin 15 Amps switch socket combination point including running 2.50 Sqmm copper conductor PVC wire as earth continuity conductor on independant board.
Supply and fixing of Switch piano , single pole one way, flush type 5 Amps capacity 230 volts complete all as specified.
Supply and fixing of switch socket combination 2 in 1 multipurpose 2/3 pin 5 amps flush type complete all as specified.
Supply and fixing switch socket combination 2 in 1 multipurpose 3pin 5/15 amps flush type complete all as specified.
Supply and fixing of electronic ceiling fan regulator stepped 2M type heavy duty suitable to work on 230 volts complete all as specified.
Supply and fixing of ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified.
Material and labour for Concealed Submain wiring with 2 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including one run of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length. Note:- Cutting and chasing will be measured and paid seperately.
Material and labour for Submain wiring with 4 runs of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 32 mm dia including two run of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Four runs of cable, two run of earth contuinity conductor and one run of conduit shall be measured as one unit length. Note:- Cutting and chasing will be measured and paid seperately.
S & in replace of Vertical type MCCB TPN DB 4 way double door made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/ Schneider/C&S
Supply and replace MCCB 415V,16KA, 125 amps 4 pole suitable for TPN V type DB .MAKE: HAVELLS/ Schneider/C&S
Supply and replace MCB DB double door TPN 4 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface. MAKE: HAVELLS/ Schneider/C&S
Supply and replace MCB double door DB SPN 8 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface. MAKE: HAVELLS/ Schneider/C&S.
Supply and fix in repair MCB TPN C series, 63 Amps, 415 volts suitable for fixing on MCB DB complete all as specified and directed. MAKE: HAVELLS/ Schneider/C&S
Supply and fix in repair MCB TP C series, 63 Amps, 415 volts suitable for fixing on MCB DB complete all as specified and directed. MAKE: HAVELLS/ Schneider/C&S
Supply and fix in repair MCB SPN C seies, 32 Amps 240 volts for fixing on MCB DB. MAKE: HAVELLS/ Schneider/C&S
Supply and fix in repair MCB SP C series 6 to 32 Amps 240 volts for fixing on MCB DB. MAKE: HAVELLS/ Schneider/C&S
Material and labour for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of andings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., and making good all as specified and as directed
M&L Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth wire 4 mm dia drawn through and including GI protection pipe of light grade 15 mm bore by means of bolts, nuts, checknuts and washers all as shown in Electrical Plate No.3 of SSR Part-I and connected to main switch board including excavation and earth work, PCC chamber in 1:3:6, RCC Cover in 1:2:4 type B-1 reinforced with 8 mm dia MS bars at 10 cm c/c, 20 mm dia medium grade GI pipe with funnel and wire mesh complete and watering arrangement all as specified. (Note: GI pipe 15mm dia, GI wire 4mm dia upto 7.5m deemed to be included in quoted rate.)
Supply and replace old unserviceable false ceiling fitting with ultra modern recess mounted 42W LED luminaire suitable for armstrong grid /POP ceiling of 2'x2' and complete with suitable aluminium frame for POP/Gypsum board 2x2 panel light,including electronic driver. Make: WIPRO/Philips/ C&S /Havells cat No. PLUTONEO2X2PLR42WLED840S
S & Fix LED batten with polycarbonate housing and integrated electronic drive of 20 Watt of power factor >.95, 6500 K colour temp. working at single phase all as specified and directed . Make :WIPRO/Philips/ C&S /Havells cat No. LUMILINEBS20WLED865SPCWH
Supply and fix LED energy efficient security light fitting of capacity of 35 W including suitable dia GI pipe bracket for fixing the light on wall all as directed. Make : WIPRO/Philips/ C&S /Havells cat No. ENDURACITYLITEPLAT PLUSSL35WLED757SASYBOPC. NOTE : quoted rate included the suitble GI pipe bracket,nuts and bolts etc.
Supply and fix sheet metal enclosure with double pole and Earth Metal Plug & Socket including 20A SP MCB complete including taking down unserviceable enclosure all as directed by Engr in Charge. MAKE: HAVELLS/ Schneider/C&S .
Taking out defective winding and rewinding of the ceiling/ exhaust fan of any size complete with equivalent new super enamelled copper wire as per existing gauge and weight as per manufacturer's design complete all as specified and directed NOTE: Cost of rewinding/capacitor/clamps/rotar/shaft or any connected items is deemed to be included in quoted rate.
Supply and lay on wall/in ground/on pole ISI marked XLPE insulated armoured, heavy duty, electric cable with aluminium conductors 1100 volts laid in trenches, floors, ducts, pipes drawn across the road/paths/drain/along poles/walls/floor/equivalent etc including jointing & testing complete all as specified of size 50 Sqmm , 4 core
Excavation in trenches not exceeding 1.5 mtr width and not exc 1.5 mtr in depth and getting out in hard /dense soil for laying / repairing of LT cable / GI pipe complete all as specified and as directed.
Supply, spread river sand of approval in cable trenches providing for cable cushioning as directed. NOTE :- Punned thickness of sand only will be measured and paid complete all as specified and as directed .
Removal of surplus soil to a distance not exc 50 mtrs away and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed .
Returning , filling incl spreading levelling watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed .
Supply and lay PCC cable covers for LT cable protection, Class LV, Type 1 of size 250x150x40mm complete all as specified and as directed
Supply and fixing from LT pole to MCCB DBs, the medium grade GI tubing of 50 mm dia for XLPE cable protection complete all as specified and as directed
K LAKSHMAN SINGH AND CO
G.CHANDRIAH AND SONS
VENKATA PRABHAVATHI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .