| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.6 LAccepted-AOC | ₹22.6 L Quoted ₹26.5 L | L-1 | Accepted-AOC DUE TO BEING LOWEST AND REASONABLE |
| 2 | L-2₹33.3 LRejected-Finance R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | ₹33.3 L | L-2 | Rejected-Finance FOUND OTHER THAN LOWEST |
| 3 | L-3₹33.3 LRejected-Finance 20 JAIN BAZAR JAMMU 180003 J K | JAMMU | JAMMU | J K | 180003 | ₹33.3 L | L-3 | Rejected-Finance FOUND OTHER THAN LOWEST |
| 4 | L-4₹33.9 LRejected-Finance | ₹33.9 L | L-4 | Rejected-Finance FOUND OTHER THAN LOWEST |
| 5 | L-5₹34.6 LRejected-Finance | ₹34.6 L | L-5 | Rejected-Finance FOUND OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | MAMTA ENTERPRISES L6 | A K JAIN AND SONS L3 | sahni construction co L5 | M/S Chib Engineers L2 | M/s Chopra Constructions L4 | M/S DC CONSTRUCTIONS L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting electrical connections from HT and LT sides of old serviceable/ damaged/ burnt step down transformers of any descriptions, capacity exceeding 63 KVAto 100 KVA, any type and taking down from the platforms or mounted on exisiting position (four poles/ two pole structure) by hydraulic cranes of suitable capacity and transporting by truck/ lorry to the workshop, opening top cover, draining out the transformer oil in clean barrels, cleaning of sludge from oil tank and conservator tank, cleaning and polishing of tapping contact point, opening carefully copper wire/ strip wound LT coils and rewinding the same after providing new necessary insulating packing material by using the same old strip/ wire, refitting top cover with replacement of studs, nuts, bolts, washers and gasket after repairs/ replacement of unserviceable parts and cleaning the transformer and making the transformer absolutely leak proof, pouring in the insulating oil in the transformer, placing in original position on four pole/ two pole structure/ platform at site and making all HT/LT connections including testing the transformer after necessary repairs, complete all as specified and as directed.
Note: Spares required for repair/ replacement of unserviceable parts shall be measured and paid separately under relevant items of BOQ. | 10 | Each Job | 2,000 ₹20,000 | 12,000 ₹1.2 L | 8,000 ₹80,000 | 7,000 ₹70,000 | 2,000 ₹20,000 | 5,000 ₹50,000 |
| 2.00 | Description all as serial item No- 1 here-in-before but for transformer of capacity exceeding 100 KVA to 200 KVA. | 3 | Each Job | 2,500 ₹7,500 | 12,000 ₹36,000 | 8,000 ₹24,000 | 8,000 ₹24,000 | 2,200 ₹6,600 | 5,000 ₹15,000 |
| 3.00 | Description all as serial item No- 1 here-in-before but for transformer of capacity exceeding 250 KVA to 400 KVA. | 3 | Each Job | 3,500 ₹10,500 | 20,000 ₹60,000 | 8,000 ₹24,000 | 20,000 ₹60,000 | 2,500 ₹7,500 | 8,000 ₹24,000 |
| 4.00 | Replacement of old unserviceable/ damaged core with new core, mild steel, of existing specifications, shape and sizes including cuting and fixing, suitable for transformers of any type and capacity, complete all as specified and as directed | 790 | Kg | 1,200 ₹9.5 L | 750 ₹5.9 L | 100 ₹79,000 | 200 ₹1.6 L | 1,200 ₹9.5 L | 500 ₹4.0 L |
| 5.00 | Supply and fixing in replacement of HT coil of transformer capacity 63 KVA to 100 KVA, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications, complete all as specified and as directed.
Note: HT coil shall have same number of turns of winding wire and with matching to manufacturer design. | 300 | Kg | 1,200 ₹3.6 L | 750 ₹2.3 L | 1,800 ₹5.4 L | 750 ₹2.3 L | 1,200 ₹3.6 L | 850 ₹2.5 L |
| 6.00 | Supply and fixing in replacement of HT coil of transformer capacity 100 to 200 KVA, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications, complete all as specified and as directed
Note: HT coil shall have same number of turns of winding wire and with matching to manufacturer design. | 160 | Kg | 1,300 ₹2.1 L | 750 ₹1.2 L | 1,800 ₹2.9 L | 750 ₹1.2 L | 1,200 ₹1.9 L | 850 ₹1.4 L |
| 7.00 | Supply and fixing in replacement of HT coil of transformer capacity 250 KVA to 400KVA, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications, complete all as specified and as directed
Note: HT coil shall have same number of turns of winding wire and with matching to manufacturer design. | 200 | Kg | 1,300 ₹2.6 L | 750 ₹1.5 L | 1,800 ₹3.6 L | 750 ₹1.5 L | 1,200 ₹2.4 L | 850 ₹1.7 L |
| 8.00 | Replacement of old unserviceable/ damaged HT bushing assembly with new HT bushing assembly (Set of three) with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, capacity 63 KVA to 100 KVA, complete all as specified and as directed | 10 | Each Set | 950 ₹9,500 | 1,500 ₹15,000 | 650 ₹6,500 | 500 ₹5,000 | 500 ₹5,000 | 500 ₹5,000 |
| 9.00 | Description all as serial item No- 8 here-in-before but for transformer of capacity 100 KVA to 200 KVA. | 3 | Each Set | 1,250 ₹3,750 | 1,500 ₹4,500 | 850 ₹2,550 | 300 ₹900 | 1,000 ₹3,000 | 1,000 ₹3,000 |
| 10.00 | Description all as serial item No- 8 here-in-before but for transformer of capacity 250 KVA to 400KVA. | 3 | Each Set | 1,500 ₹4,500 | 2,000 ₹6,000 | 1,250 ₹3,750 | 400 ₹1,200 | 1,000 ₹3,000 | 2,000 ₹6,000 |
Updated dates
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
20 Mar 2026, 6:00 pmClosed
GE, GE (SOUTH) AKHNOOR
Military Engineer Services GE (South) Akhnoor PIN- 900234 c/o 56 APO
MAINT OF EXTERNAL LT ES NETWORK IN RAKHMUTHI MIL STN AND ITS OUTSTATIONS UNDER GE SOUTH AKHNOOR
2026_MES_753594_1
GES/AKH-75/2025-26
Open Tender
Civil Works - Others
180 days
RAKHMUTHI
AS PER NIT
9 documents required · 9 mandatory
₹500
GE SOUTH AKHNOOR
₹70,000
4 May 2026
20 Feb 2026
27 Mar 2026
20 Feb 2026
20 Mar 2026
6 Mar 2026
Disconnecting electrical connections from HT and LT sides of old serviceable/ damaged/ burnt step down transformers of any descriptions, capacity exceeding 63 KVAto 100 KVA, any type and taking down from the platforms or mounted on exisiting position (four poles/ two pole structure) by hydraulic cranes of suitable capacity and transporting by truck/ lorry to the workshop, opening top cover, draining out the transformer oil in clean barrels, cleaning of sludge from oil tank and conservator tank, cleaning and polishing of tapping contact point, opening carefully copper wire/ strip wound LT coils and rewinding the same after providing new necessary insulating packing material by using the same old strip/ wire, refitting top cover with replacement of studs, nuts, bolts, washers and gasket after repairs/ replacement of unserviceable parts and cleaning the transformer and making the transformer absolutely leak proof, pouring in the insulating oil in the transformer, placing in original position on four pole/ two pole structure/ platform at site and making all HT/LT connections including testing the transformer after necessary repairs, complete all as specified and as directed. Note: Spares required for repair/ replacement of unserviceable parts shall be measured and paid separately under relevant items of BOQ.
Description all as serial item No- 1 here-in-before but for transformer of capacity exceeding 100 KVA to 200 KVA.
Description all as serial item No- 1 here-in-before but for transformer of capacity exceeding 250 KVA to 400 KVA.
Replacement of old unserviceable/ damaged core with new core, mild steel, of existing specifications, shape and sizes including cuting and fixing, suitable for transformers of any type and capacity, complete all as specified and as directed
Supply and fixing in replacement of HT coil of transformer capacity 63 KVA to 100 KVA, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications, complete all as specified and as directed. Note: HT coil shall have same number of turns of winding wire and with matching to manufacturer design.
Supply and fixing in replacement of HT coil of transformer capacity 100 to 200 KVA, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications, complete all as specified and as directed Note: HT coil shall have same number of turns of winding wire and with matching to manufacturer design.
Supply and fixing in replacement of HT coil of transformer capacity 250 KVA to 400KVA, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications, complete all as specified and as directed Note: HT coil shall have same number of turns of winding wire and with matching to manufacturer design.
Replacement of old unserviceable/ damaged HT bushing assembly with new HT bushing assembly (Set of three) with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, capacity 63 KVA to 100 KVA, complete all as specified and as directed
Description all as serial item No- 8 here-in-before but for transformer of capacity 100 KVA to 200 KVA.
Description all as serial item No- 8 here-in-before but for transformer of capacity 250 KVA to 400KVA.
Replacement of old unserviceable/ damaged LT bushing assembly with new LT bushing assembly (Set of Four) with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, capacity 63 KVA to 100 KVA, complete all as specified and as directed.
Description all as serial item No- 11 here-in-before but for transformer of capacity 100 KVA to 200 KVA.
Description all as serial item No- 11 here-in-before but for transformer of capacity 250 KVA to 400 KVA.
Replacement of old unserviceable/ damaged cork sheet gasket with new cork sheet gasket, suitable for transformer of any type, capacity 63 KVA to 100 KVA, complete all as specified and as directed.
Description all as serial item No- 14 here-in-before but for transformer of capacity 100 KVA to 200 KVA.
Description all as serial item No- 14 here-in-before but for transformer of capacity 250 KVA to 400 KVA.
Replacement of old unserviceable/ damaged tap changing assembly with new tap changing assembly, off load, on HT winding to vary the voltage ±7.5%, in steps of 2.50%, including necessary connection, HT winding, re-insulation for complete functioning of tap changer, transformer capacity 63 KVA to 100 KVA, complete all as specified and as directed.
Description all as serial item No- 17 here-in-before but for transformer of capacity 100 KVA to 200 KVA.
Description all as serial item No- 17 here-in-before but for transformer of capacity 250 KVA to 400 KVA.
Replacement of old unserviceable/ damaged air breather assembly with new air breather assembly with silica gel suitable for 11/0.433 KV transformer including nuts, bolts and washers, suitable for transformer 63 KVAto 100 KVA, complete all as specified and as directed.
Description all as serial item No- 21 here-in-before but for transformer of capacity 100 KVA to 200 KVA.
Description all as serial item No- 21 here-in-before but for transformer of capacity 250 KVA to 400 KVA.
Supply and filling fresh transformer oil to top-up and filling in the existing transformer, di-electric strength not than 45 KV, meeting Bureau of Indian Standards: IS 335-1993 (Reaffirmed-2005) specification, examined in a 100mm thick layer at 270°C, clear, transparent and free from all type of suspended matter or sediment, complete all as specified and as directed. Make: IOCL/ HPCL/ BPCL/ Reliance.
Preparation of old, external surface of transformers capacity 63 KVA to 100 KVA, by removing the scrap, rust, washing including cleaning and spray painting with two coats of synthetic enamel paint including numbering MES No in white colour synthetic enamel paint, at site or at workshop, complete all as specified and as directed
Description all as serial item No- 25 here-in-before but for transformer of capacity exceed 100 KVA to 200 KVA.
Description all as serial item No- 25 here-in-before but for transformer of capacity 250 KVA to 400 KVA.
Disconnecting electric connections of servo voltage stabilizers, capacity 30 KVA to 60 KVA, draining out the servo voltage stabilizers oil in clean barrels for re-use, cleaning of sludge from oil tank and transporting to workshop for repairs and return back to it's original position after repairs including loading and unloading by mechenical means, complete all as specified and as directed Note: Spares required for repair/ replacement of unserviceable parts shall be measured and paid separately under relevant items of BOQ.
Description all as serial item No- 28 here-in-before but for servo voltage stabilizers of capacity exceeding 75 KVA to 100 KVA capacity.
Description all as serial item No- 28 here-in-before but for servo voltage stabilizers of capacity 200 KVA to 350 KVA capacity.
Replacement of old unserviceable Printed Circuit Board (PCB) with new Printed Circuit Board (PCB) of voltage stabilizer as per existing make and type, capacity 30 KVA to 60 KVA, complete all as specified and as directed.
Description all as serial item No- 31 here-in-before but for servo voltage stabilizers of capacity exceeding 75 KVA to 100 KVA capacity.
Description all as serial item No- 31 here-in-before but for servo voltage stabilizers of 200 KVA to 350 KVA capacity.
Replacement of old unserviceable carbon bushes with new carbon bushes of voltage stabilizer as per existing make and type, capacity 30 KVA to 60 KVA, complete all as specified and as directed.
Description all as serial item No- 34 here-in-before but for servo voltage stabilizers of capacity exceeding 75 KVA to 100 KVA capacity.
Description all as serial item No- 34 here-in-before but for servo voltage stabilizers of 200 KVA to 350KVA capacity.
Replacement of old unserviceable servo motor with new servo motor of voltage stabilizer as per existing make and type, capacity 30 KVA to 60 KVA, complete all as specified and as directed.
Description all as serial item No- 37 here-in-before but for servo voltage stabilizers of capacity exceeding 75 KVA to 100 KVA capacity.
Description all as serial item No- 37 here-in-before but for servo voltage stabilizers of 200 KVA to 350 KVA capacity.
S&F in replacement Push button suitable for servo voltage stabilizers of any capacity, as per existing design and range, fixing in repairs, complete all as specified and as directed.
S&F in replacement Digital Voltmeter, range 0-500 Volts, size 96mm x 96mm, flush type, complete all as specified and as directed.
S&F in replacement Digital Ammeter, range 0-250 Amps, size 96mm x 96mm, square shape, complete all as specified and as directed.
Replacement of old unserviceable Servo Dimmer Booster Coil with new Servo Dimmer Booster Coil, for automatic voltage corrections, make, type and design as per site requirement, suitable for voltage stabilizer capacity 30 KVA to 60 KVA, complete all as specified and as directed.
Description all as serial item No- 44 here-in-before but for transformer of capacity exceeding 75 KVA to 100 KVA capacity.
Description all as serial item No- 44 here-in-before but for transformer of capacity 200 KVA to 350 KVA.
Replacement of old unserviceable Dimmer Gear set with new cast iron Dimmer Gear set, for automatic voltage corrections, make, type and design as per site requirement, suitable for voltage stabilizer capacity 30 KVA to 60 KVA, complete all as specified and as directed.
Description all as serial item No- 47 here-in-before but for transformer of capacity exceeding 75 KVA but not exceeding 100 KVA capacity.
Description all as serial item No- 47 here-in-before but for transformer of capacity 200 KVA to 350 KVA.
M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strep 32 x 6 mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel drawn through 40 mm dia light grade GI pipe as shown in electrical plate no 3 of SSR part I of 2009 including necessary excavation and earth work GI pipe 20mm dia light grade for watering PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to panel board as indicated including testing complete, including taking down of existing earthing, complete all as specified and as directed.
S&F in replacement of old unserviceable/ damaged Change over switch with new Change over switch, on load, rating 100 Amps, four poles, 415 Volts, AC, 50 Hz, with center handle, conforms to IS:13947 (Part-3); IEC:60947-2, complete all as specified and as directed.
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and adjustable magnetic setting, 160 Amps with breaking capacity 36 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge.
M&L for carryout Physical check and amd Electrical testing of transformer as per following criteria by approved firm as per following details all as directed. (a) Check Oil level, colour of oil, oil leaking, oil temperature. (b) Check Breather with silica gel, tape position and noise level. (c) Status of HT/LT connection, tightening the connections, check load in each phase and load balancing if required (d) Insulation test of HT/LT to earth, HV resistance and BDV of oil. (e) Tightening of earth connection and refixing loose earth conductor with clamps & clips.
S&F in replacement of old unserviceable/ damaged Change over switch with new Change over switch, on load, rating 200 Amps, four poles, 415 Volts, AC, 50 Hz, with center handle, conforms to IS:13947 (Part-3); IEC:60947-2, complete all as specified and as directed.
Supply, erecting and fixing in replacement of old PCC pole in true vertical position, with steel tubular swagaed pole (410 SP-31), 09 meter long, complete with cast iron base plate, pole cap/ final taper plug, bolts, nuts and washers, welded reduced section and longitutinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint including taking down old damaged poles, complete all as specified and as directed.
Replacement of old unserviceable/ damaged loop type insulator with new loop type insulator, vitreous porcelain, white, brown or green, large size, with overall dimensions 65 x 90mm, clearance of hole 16.0mm, complete all as specified and as directed.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 25.0 Sqmm, 4-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 50.0 Sqmm, 3.5-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 95.0 Sqmm, 3.5-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed.
S&F in Replacement of old unserviceable/ damaged GI pipe with new GI pipes/ Tubes, 'light grade', galvanised, 50mm bore, ISI marked, laid in trenches or fixed to walls/ poles including mild steel clamps, nuts, bolts and washers; for protection of electric cable, complete all as specified and as directed.
Replacement of old unserviceable/ damaged GI pipe with new GI pipes/ Tubes, 'light grade', galvanised, 40mm bore, ISI marked, laid in trenches or fixed to walls/ poles including mild steel clamps, nuts, bolts and washers; for protection of electric cable, complete all as specified and as directed.
M&L in replacement Gang operated Isolating Switch 11 KV Triple pole vertical type, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 Amps, 15 insulators, including drop out fuse assembly as specified and directed.
M&L in replacement Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo Amp for 11 KV, complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10sqm on plan for foundation or for shaft, well, manhole's, for laying of cables/pipes and foundation of poles stays and getting out in any type of soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 mtrs in depth, not exceeding 10sqm on plan for foundation or for shaft, well, manhole's, for laying of cables/pipes and foundation of poles stays and getting out in any type of soil complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick ,complete all as specified and as directed.
Removing of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed. Note: Punned thickness shall be measured.
Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed.
Plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as in mass concrete in foundation of poles etc, complete all as specified and as directed.
Plain cement concrete M-10 (1:3:6), type C-2 (using 40mm graded crushed stone aggregate), as in mass concrete in foundation of stays etc, complete all as specified and as directed.
Plain cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregate), as in coping of poles including necessary form work, finish even and smooth without using extra cement, complete all as specified and as directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
td752526.pdf
Tender Documents • 0.69 MB
BOQ_844070.xls
BOQ • 5.35 MB
Download all tender documents and submit your bid