Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹36.3 L+₹69,330 (1.95%)Rejected-Finance KRISHNA SOCIETY OPP TODI XRAY AND DIAG CENTRE MAKUM ROAD TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L2 | Rejected-Finance Higher | |
| 3 | L3₹36.5 L+₹86,596 (2.43%)Rejected-Finance | L3 | Rejected-Finance Higher | |
| 4 | L4₹37.6 L+₹2.0 L (5.71%)Rejected-Finance RSD STREET HALL BAZAR AMRITSAR 143001 PUNJAB | AMRITSAR | AMRITSAR | PUNJAB | 143001 | L4 | Rejected-Finance Higher | |
| 5 | L5₹39.6 L+₹4.0 L (11.3%)Rejected-Finance | L5 | Rejected-Finance Higher |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
12 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAMS
GE NAMS KHASA CANTT AMRITSAR
REPAIR / REPLACEMENT OF LIGHTENING PROTECTION SYSTEM AND MISC WORKS OF MES INSTALLATION AT NAMS
2021_MES_413070_1
GE NAMS - 86 / 2020 - 21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NAMS CANTT
Class D
Category b i
6 documents required · 6 mandatory
₹500
Yes
GE NAMS
₹80,000
Yes
15 Mar 2021
15 Jan 2021
13 Feb 2021
15 Jan 2021
12 Feb 2021
29 Jan 2021
60 days
Amount
Supply & fix in replacement of aluminium strip 25 mm x 3.15 mm Complete with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. Note:- All T & P, 30 mtr staging material and men power risk is the responsibility of contractor and no extra amount will pay on this regard.
Supply and fix in replacement of test point terminal blocks made of gun metal or phosphorus bronze size 75x75x25 mm drill and screwed including three numbers 8 mm dia 25 mm long hexgonal head screw complete all as specified and directed
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directely in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate at a depth not less than 2.25m below ground level connected with an including GI Strip 32mmx6mm by means of nuts and bolts , check nuts, washers of galvanised iron and thimbles, earth plate surrounded by picked layers of coal, dust and common salt 15cm thick all around top and bottom and watering , excavation, earth work PCC Chamber in cement concrete 1:3:6 type C-2 and RCC Cover in M-20(design mix) complet all as shown in Electric plate No.5 of MES Standerd schedule of rates (Part-I) of 2009 complet all as specified and directed and testig on completion. Note(i) Unit rate shall be included for protection pipe, GI water pipe wire mesh funnel excavation , RCC pit cover , test point, 32mmx6mm GI Strip top of earth plate upto 5m above ground level and if GI Protection is less than 5m no price adjustment shall be made (ii) PCC Pit shall be provided at least 500mm away from the earth pit and extra cost of additional length of water pipes and fittings, junction elbowetc. Shall be deemed in inclusive.
Supply & fix in replacement of single pointed air termination Aluminium rod, 12 mm dia, 300 mm long complete all as specified and directed
Supply & fix in replacement of GI strip 32 mm x 6 mm buried In ground complete all as specified and directed
Excavation in trenches not exceeding 1.5m wide & not exceeding 1.5m in depth for and getting out in any of soil complete all as specified and directed.
Returning, filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified
Supply,laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps of f size 77mm outer dia and 63mm inner dia all as specified and directed by Engr in Charge.
All as per Item No 10 here in before but size 50mm outer dia and 38mm inner dia for LT UG cables
All as per Item No 10 here in before but of size 90mm outer dia and 76mm inner dia for LT UG cables
All as per Item No 10 here in before but of size 120mm outer dia and 103mm inner dia for LT UG cables
Supply and fixing Single phase propeller type ventilating ( Exhaust fan) heavy duty AC 230 volts 450 mm sweep, metallic body complete with louvrers and shutters including making and finishing good hole in wall for fixing Exhaust fan of 450mm sweep including necessary brick work and plaster to match the existing surface complete all as specified.
Taking down aluminium point wiring from existing conduit / batten (light, fan, socket or power) complete such as switches, ceiling rose, pendent, regulators, socket, light fittings etc and removing material from site and making good the disturbed surface of wall / floor etc, complete all as specified and directed
M&L for point wiring with 1.5 sqmm (Nominal area ) 1100 Volt PVC Insulated , FRLS unsheathed and multi stranded copper conductor cable in existing PVC Concealed conduit 1.5mm thick for one light / fan point or bell point controlled by one switch (including cutting chases and making good the distributed surfaces) and fixing new 3mm thick plastic laminated sheet top cover, sheet screws and 1.6mm thick GI sunken boxes after removing old unserviceable plastic laminated sheeet and sunken boxes included 1.5 Sqmm stranded copper conductor with green PVC Insulation earth contunity conductor connected to common earth dolly etc . complete all as specified and directed for one light /fan/ buzzer point controlled by one 5 Amp switch one way
All as per Srl item No 16 here in before but for one 5 amps socket out let independent complete all as specified.
All as per Srl item No 16 here in before but on the same board completeall as specified
All a per item No 16 here in before but with 2.5 Sq mm size cable multi stranded FRLS copper wire unsheathed for one 3 pin socket outlet 15 Amps on independent board including continuous earth wire of PVC insulated 1.5 Sq mm copper solid conductor connecting to common earth dolly complete.
Supply and Fixing in replacement switch piano type 6 Amps one way 230 volts AC complete all as specified and as directed
Supply and Fixing in replacement socket type heavy duty regulator 5 step 230 volts AC complete all as specified and as directed
Supply and Fixing in replacement socket outlet 5 pin, 6 Amps flush type 230 volts AC complete all as specified and as directed
Supply and Fixing switch piano 16 Amps type one way 230 volts AC complete all as specified and as directed
Supply and Fixing in replacement socket outlet 6 pin 6/16 Amps multi purpose flush type 230 volts AC complete all as specified and as directed
Supply and fixing ceiling fan 1200mm sweep Copper winding complete all as specified and directed
Supply and fixing in replacement ceiling rose 65X50 mm two to three terminals complete all as specified.
Material and labour for replacement of lamp holder insulated body with back plate angle type for batten fitting fixed on bakelite sheet 100mmx100mm with 10 Watt LED Bulb 230V AC cool day light 6500K having maximum height 1020mm heavy duty complete all as specified.
Supply and fixing in replacement of LED T-8 tube light CRCA Fitting with single side connection polycarbonate LED tube rod 18/20W 4 feet 1 x 18/20 watt box type including rotary type bipin holder and connection with PVC insulalted twin core 23/0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed.
Supply and fixing in replacement of MCB single pole 6 to 32 Amps all as specified and directed
S & F in replacement of MCB 40 amps single pole with neutral, AC 230 volts complete all as specified and directed.
Supply & fixing in replacement of single pole sheet metal enclosures with two pin & earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and as directed.
Supply and fixing in replacement of HT underground cable XLPE insulated PVC bedded, galvanised steel strip armoured electric power cables (heavy duty) with stranded aluminium conductor 11000 volts grade cross sectional area 300 sqmm 3 core laid in duct / trench/along pole etc including making connection complete all as specified and directed.
Supply and fixing in replacement of sheet metal enlosure for DBs when MCBs to be used double door factory made flush fixed complete with 100 amps rated bus-bar 240 volts single phase 8 ways including necessary brick work and plaster to match with the existing surface complete all as specified.
Supply and fixing in replacement of sheet steel enclouser distribution boards, double door factory made TPN Vertical 4 way 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulated copper jumpers of suitable size from the MCCB to the out going circuits one incoming MCCB and 12 outgoing MCBs circuits comprising of 3 phase 4 wire of suitable rating complete all as spcd and directed with the following accessories :- (a) MCCB 100 amps, 25 KA, TP, 415 volts, 50 Hz = 01 No. (Note:- Out going MCB shall be measured and paid for separately)
M&L in replacement of two single core sub main wiring 6 Sqmm multi-strand PVC insulated copper conductor FRLS cable including PVC insulated copper conductor cable of size 4 Sqmm as cotinuous earth wire connecting to common earth including connections of cable with MCBs or bus bars complete all as specified and directed
M&L in replacement of two single core sub main wiring 4 Sqmm multi-strand PVC insulated copper conductor FRLS cable including PVC insulated copper conductor cable of size 2.5 Sqmm as cotinuous earth wire connecting to common earth including connections of cable with MCBs or bus bars complete all as specified and directed
Supply & fix in replacement Ductile iron pipe class K-7 ISI marked with internal cement mortar lining and external zinc and bitumen coated pipes 200 mm bore confirming to IS 8329 : 2000 complete with push on rubber gasket joint complete all as specified and directed.(Note : Earth work will be measured and paid separately.
Supply & fix in replacement Ductile iron pipe class K-7 ISI marked with internal cement mortar lining and external zinc and bitumen coated pipes 150mm bore confirming to IS 8329 : 2000 with push on rubber gasket joint complete all as specified and directed.(Note : Earth work will be measured and paid separately
Supply & fix in replacement Ductile iron pipe class K-7 ISI marked with internal cement mortar lining and external zinc and bitumen coated pipes 100mm bore confirming to IS 8329 : 2000 complete with push on rubber gasket joint complete all as specified and directed.(Note : Earth work will be measured and paid separately
Supply and fixing in replacement of HT underground cable XLPE insulated PVC bedded, galvanised steel strip armoured electric power cables (heavy duty) with stranded aluminium conductor 11000 volts grade cross sectional area 185 sqmm 3 core laid in duct / trench/along pole etc including making connection complete all as specified and directed.
Supply & fix in replacement Cast iron sluice valve, ISI Marked 200 mm bore flanged of class 1.6 PN having spindle made out of gun metal, operating wheel nuts, bolts, packing complete all as specified and directed.
Supply & fix in replacement Cast iron sluice valve, ISI Marked 150 mm bore flanged of class 1.6 PN having spindle made out of gun metal, operating wheel nuts, bolts, packing complete all as specified and directed.
Supply & fix in replacement Cast iron sluice valve, ISI Marked 100 mm bore flanged of class 1.6 PN having spindle made out of gun metal, operating wheel nuts, bolts, packing complete all as specified and directed.
supply ,fixing in replacement of GI steel tubing 20mm bore with replacement of US fittings laid in trench/wall/floor including necessary saddles and clamps ,complete all as specified and directed.
M&L in replacement Air release valve of size 100mm/200mm bore with two air outlet conforming to IS 14845 and fixing up dectile Iron pipe ,complete all as specified and directed.
Material & Labour in replacement cast iron fittings for flanged or spigot socketed pipe such as tail piece connecting pieces bends tappers, tee pieces (Single or double branch) any type & angle/radious and straight connecting pieces suitable for bore upto 200mm dia pipe complete all as specified and directed.
M & L in replacement of integral LED aviation light comprising of aluminium housing with polycarbonate enclosure are provided,complete all as specified and directed.
Material & labour in replacement of raising main/delivery/over flow/wash out pipe of OHT height 30 mtr made out of DI pipe flanged type K-9 100 MM of size 3.00 mtr including rubber gas ket /gland peacking , nut and bolts etc.Note:- All T & P, 30 mtr staging mtrl and men power risk contractor responsibility.
Material & labour in replacement of raising main/delivery/over flow/wash out pipe of OHT height 30 mtr made out of DI pipe flanged type K-9 150 MM of size 3.00 mtr including rubber gas ket /gland peacking , nut and bolts etc. Note:- All T & P, 30 mtr staging mtrl and men power risk contractor responsibility.
Material & labour taking out CI/MS pipe flanged type 150mm / 100 mm dia of rising main/delevery/over flow/wash out of OHT of height 30mm cleaning and refixing with replacing nut bolts, rubber gas kit /gland peacking etc. Note:- All T & P, 30 mtr staging mtrl and men power risk contractor responsibility.
Material & Labour including taking out old UNSV water level, mechanical level made wooden type and supply and fix new waer level scale , mechanical level, indicator wooden scale type complete with FRP scale, float wire, float guide pipe, breket and pulley, counter weight indicator pin etc for over head reservior on 30 mtr height.
Supply in replacement OT soluation for chlorine test 500 ML bottle complete all as specified and directed.
Material & labour for restrainging ACSR conductor HT/LT providing suitable proper sag all as specified and directed.
Supply & fixing in replacement of stay assembly comprising of 7/2.50mm galvanized MS stay wire of reqd length, fixed to poles with and including of FI clamps made out of FI 40x6mm and nuts bolts washers of suitable size MS stay bow 14mm dia galvanized 40cm long MS galvanised stay rod threaded with nut 16mm dia 21 Cm long with washers MS stay plate galvanized 230x30x6mm incl necessary Excavation and PCC all as specified and directed by Engr-in charge
Prunning of trees of over head HT/LT lines by taking proper shutdown & removing the same from site upto a distance of 50 mtr all as directed by Engr in Charge.
Taking out carefully manually by excavation of existing LT/HT cable with loops and relaying with DWC pipe the same after repair of cutting the damages / burnt parts of cable and reconnecting its into original positions complete with cable joints all as specified and directed by Engineer-in-Charge.Note:-(i) HT/LT Cable Joint & DWC Pipe will be measured and paid sepearetly. (ii) Unit rate shall be included in excavation and returning filling.
S & F in replacement End/ straight through joint heat shrinkable suitable for 3 core 11000 volts XLPE HT UG cable of size 185 Sq mm to 300 Sq mm complete all as specified and directed.
Material and Labour straight through joint heat shinkable suitable for 70 sqmm to 120 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 70 sqmm 3.5 core complete all as specified and directed.
All as per srl item No 61 here-in-before but of size 50 Sqmm 3.5 core.
All as per srl item No 61 here-in-before but of size 35 Sqmm 3.5 core.
All as per srl item No 61 here-in-before but of size 25 Sqmm 3.5 core.
All as per srl item No 61 here-in-before but of size 16 Sqmm 4 core.
All as per srl item No 61 here-in-before but of size 10 Sqmm 4 core.
Labour for drilling hole under the road with the help of drilling machine without damaging the road horizontally for road crossing GI tubing of any size for cable protection complete all as specified and directed.
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as specified and directed. Note :-Punned down thickness of sand shall be considered for measurement)
Supply and laying un-reinforced precast concrete cable cover factory made, class HV, type I, flat of size 300mm x 180mm x 40mm complete all as specified and directed.
Supply and fixing in replacement LED type street light fitting pressure die cast aluminium housing(Heat sink)for effective thermal management,sturdinessexcellent corrosion resistant IP 66,Assemetric Lens of luminaires 90 watt LED 5700K complete fitting.
Repair of existing street light of any type or discription, fixed in vertical position with poles/wall including disconnecting the electric connection, removing from pole/wall if required, carrying out minor repairs like disconection of wire/cable,cleaning of carbon on OH line and replacing starter/fuses,etc as required at site to make the items functional and refixing the same at same location or any other location, connecting with electric feeder and testing for functioning engaging sufficient man power and tool and plant etc to ensure safety of light/pole as well as working persons complete all as specified and directed. Note : (i) The un-serviceable items shall be replaced under respective items of relevent schedule as below . (ii) T&P viz tools , ladder any type are provided by the contractor to the electrician party.
Supply only in replacement Open Construction copper ballast (Choke) suitable for 70 watt HPSV/MH light fitting complete all as specified and directed.
Supply & fix inreplacement Ingnitor suitable for 70 to 250 watt HPSV Lamp ISI marked all as specified and directed.
Supply only in replacement HPSV lamp 70 watt, tubular type complete all as specified and directed.
Supply and fixing in replacement thermoplastic polycarbonate cable junction box hinged door type of size 200x160x 98 mm for 3 Phase and Nutral incoming cable, 3 Phase and Nutral outgoing cable and single Phase & Nutral connection for light fitting with aluminiuam bus bar of 25 x 3mm strip, 4 pole, 415 volt with insulator porceline and one MCB sp 6 Amp, 240 Volt and clamp system (screw less), shock proof safe IP-55, weather proof, rust, dust and water proof internally embedded gasket with provision for cable entry through gland alongwith MS clamps and mounting brackets as required at site complete all as specified & directed.
Supply and lay 3 layer (inner antimicrobial, outer UV stablized) ISI marked , IS- 15801, PP-R pipes SDR 13.5 (PN- 8) and PP-R plain fittings in trenches /walls/ceilings or laying in floors complete of size outer dia 80mm.
Exacavates and relaying cables loops near the poles LT Panels,LT Pole & transformers, cutting the damages/burnt parts of cable and reconnecting its positions complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement LED type street light fitting pressure die cast aluminium housing(Heat sink)for effective thermal management,sturdinessexcellent corrosion resistant IP 66,Assemetric Lens of luminaires 60 watt LED 5700K complete fitting.
M & L in replacement for air break gang operated triple pole mechanically operated mounted on HT insulators and galvanised steel frame with operating rod of 25mm bore medium grade GI pipe suitable for operation while standing on ground for current rating 200 Amps suitable for 11000 volt 50 Hz supply including 12 insulator and drop out fuse carrier element all as specified and directed by Engineer-in-charge.
Supply & fix in replacement disc type porcelain white, brown or green insulator including one galvanized mild steel spindle, two galvanised iron washers & one galvanised nut for working pressure 11000 volts grade.all as specified and directed by Engr-in charge
Supply & fix in replacement pin type porcelain white, brown or green insulator including one galvanized mild steel spindle, two galvanised iron washers & one galvanised nut 150mm height,150mm dia for working pressure 11000 volts grade.all as specified and directed by Engr-in charge
Supply and lay 3 layer (inner antimicrobial, outer UV stablized) ISI marked , IS- 15801, PP-R pipes SDR 13.5 (PN- 8) and PP-R plain fittings in trenches /walls/ceilings or laying in floors complete of size outer dia 110mm .
Supply & fix in replacement pin type porcelain white, brown or green insulator including one galvanized mild steel spindle, two galvanised iron washers & one galvanised nut 50mm height,65mm dia for working pressure 1100 volts grade.all as specified and directed by Engr-in charge
Material and labour in replacement for ACSR conductor of any type drawn straight horizontal on HT over head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent HT/LT poles and calculating weight of conductor of size length by adding 3% extra for sag jointing jumpers etc complete all as specified and directed.
S & F in replacement of MCCB Capacity 36 KA 4 pole 400 Amps adjustable thermal megnate to release type with preader and aluminium lugs all as required at site.
All as per item 85 here in before but 250 Amp 36 KA
All as per item 85 here in before but 315 Amp 36 KA
All as per item 85 here in before but 200 Amp 36 KA
All as per item 85 here in before but 160 Amp 36 KA
Supply laying & testing in replacement cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 185 sqmm 3.5 core complete all as specified and directed.
All as per srl item No 90.00 here-in-before but of size 95 Sqmm 3.5 core.
M & L in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint.
M & L in replacement of out door type aluminuam bus bar chamber feeder box of cap 300 Amp , 3 phase, 4 wire, 415 Volts with porcelain insulator of size 90 x 60 x 45 cm made out of 3.15 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer and fixed and supported with anlge iron grouted in PCC 1:2:4 upto 0.30 mtr high from ground level all as directed by Engr-In-Charge.
Supply and fixing in replacement flood Light Luminaire 120 watt with high power SMD LED cool white supply voltage 220/240/50 Hz, light engine driver base pole adapter pressure die cast powder coated in IP 66 Inculding protection over temperature complete all as specified and directed.
Supply and fixing in replacement flood Light Luminaire 150 watt with .high power SMD LED cool white, supply voltage 220/240/50 Hz, pressure die cast powder coated in IP 66 Incliding protection over temperature complete all as specified and directed.
Supply & fix in replacement of LED Street Light Luminaire 25 watt 6000K with .high power LED cool white supply voltage 220/240/50 Hz, light engine driver base pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens complete all as specified and directed.
Supply and fixing in replacement bracket made out of GI pipe 50/ 40 mm medium grade 1.2 mtr long made to shape with fixing clamps of MS flat 40x6mm nut bolts etc for street light all as specified and directed
Supply and fixing in replacement of complete male & female contacts of gang operative switch made out of brass and rated capacity 200 amps ,make matching with the existing switch complete all as specified and directed .
Supply and fixing in replacement of 3 Nos copper ribbon suitable for 200 amps rated capacity gang operative switch, 45 CM long complete all as specified and directed .
Supply and fixing for earthing complete with copper earth plate electrode 600x600 x 3.15mm thick burried directly in ground( earth pit not less than 3.00 mtr deep below ground level) with top edge of earth plate not less than 2.0 mtr below normal ground level ,connected to copper strip of size 20X3.15mm as earthing lead by means of nuts and bolts check nuts and washers of copper/brass all as shown on electrical plate No -3 of SSR 2009- Part 1 connected to earthing test point all as specified or indicated including testing on completion. The quoted unit rate shall include the following elements as given below :- (a) Copper earth electrode as mentioned above (b) Main earthing lead of 32X6 mm copper strip from earth electrode to test point up to 7.5 mtrs. (c) Connecting earthing lead and electrode all as specified and testing complete. (d) Adequate quantity of charcoal and salt. (e) GI protection pipe of 40 mm dia light grade of length not more than 5.00 mtrs. (f) Necessary excavation, earth work and PCC pit , angle iron 40x40x6mm frame including RCC cover.
Supply and laying or fixing in replacement 1100 Volts grade heavy duty cable with PVC insulated aluminium standard conductor served with an inner sheathing of PVC tape and over all PVC Sheathed one twin core 10 Sqmm cable standard conductor cable flat or circular all as specified and directed by Engineer- in- Charge.
Material and labour for PCC 1:4:8 type D-2 using 40mm graded broken stone aggregate as in mass concrete in foundation of poles complete all as specified.
Supply and fixing GI tubing light grade 15 mm dia bore for providing support for the aluminium air termination electrode complete all as specified and directed
Supply and laying GI steel tubing, 80mm bore, light grade with all fittings, laid in trenches / under roads / along pole / wall for protection of Cable / GI wire / GI strip etc complete all as specified and directed.
ss enterprises
Roop Sons and Co
Intrernational Engineers
BHARAT ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .