| 1 | L1₹30.5 CrAccepted-AOC BADRI RAI COMPANY ARUN KUMAR RAI DULIAJAN STATION ROAD P O DULIAJAN P S DULIAJAN DIBRUGARH PIN 786602 | DULIAJAN | DIBRUGARH | ASSAM | 786602 | ₹30.5 Cr | L1 | Accepted-AOC Lowest quote. |
| 2 | L2₹30.5 CrRejected-Finance | ₹30.5 Cr | L2 | Rejected-Finance High Quoted |
| 3 | L3₹38.0 CrRejected-Finance | ₹38.0 Cr | L3 | Rejected-Finance Highest Quoted |
| 4 | Rejected-Technical | - | - | Rejected-Technical Does NOT satisfy the NIT criteria. |
Tender Value
₹31.3 Cr
EMD Value
₹56.3 L
Closing Date
6 Dec 2019, 6:00 pmClosed
AGM Engg (C)
Assistant General Manager Engg. (Civil), CHQ-NER, 2nd Floor, AAI Operational offices, Rangpuri, New Delhi 110037
Construction of ATC Tower Cum Technical block at Dibrugarh Airport.
2019_AAI_32760_1
AAI/CHQ/ENGG/NER/DIB/ATC TOWER
Open Tender
Construction Works
730 days
Dibrugarh
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,900
AAI
₹56.3 L
11 Mar 2020
16 Nov 2019
16 Dec 2019
16 Nov 2019
6 Dec 2019
29 Nov 2019
16 Nov 2019 - 25 Nov 2019
Amount
CIVIL WORKS (SH: EARTH WORK)
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. (a) All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. (a) Ordinary rock.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (a) All kinds of soil.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : (a) All Kinds of soil. (i) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil.
Carriage of Earth by mechanical transport including loading, unloading and Stacking. carriage up to 5 KM complete.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
(SH: CONCRETE WORK)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form work for : a) Foundations, footings, bases for columns.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
(SH: REINFORCED CEMENT CONCRETE WORK)
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Shelves (Cast in situ)
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts.
Stairs, (excluding landings) except spiral-staircases.
Extra for shuttering in circular work (Columns, Pillars, Piers, Abutments, Posts and Struts.)
Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like.
Edges of slabs and breaks in floors and walls.Under 20 cm wide.
Weather shade, Chajjas, corbels etc., including edges.
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). a) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. upto plinth level. a) Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. a) Thermo-Mechanically Treated bars of grade Fe-500D or more.
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).
All works upto plinth level.
All works above plinth level upto floor V level.
Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable /recoverable separately.
Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)
Providing M-40 grade concrete instead of M-25 grade BMC/ RMC. (Note : Cement content considered in M-40 is @ 360 kg/ cum)
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof.
(SH: BRICK WORK)
Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means.
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick (or as per drawing) AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick (or as per drawing) AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
(SH: MARBLE & GRANITE WORK)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade.
Area of slab upto 0.50 sqm
Area of slab over 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
Granite Stone of approved shade.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
(SH: WOOD & PVC WORK)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). (a) Second class teak wood.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : a) 2nd class teak wood. 50x12 mm
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. A) Fixed to steel windows by welding.
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (a) 250x10 mm
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete.
Providing and fixing 50 cm long aluminium kicking plate of size 100x3.15 mm, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. A) Single rubber stopper
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive.
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. a) 1.0 mm thick
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/ m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-incharge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. a) 125 mm.
Providing and fixing Toilet cubicals as under with door, pilaster and divider of Titan 12mm thick Box-UP Series Merino/Greenlam or equivelent make board both side decorative high pressure laminates (HPL) of required colour ,shade and sizes including stainless steel accessories ( SS-304 grade) like square top rail, box, knob, thumb turn and indicator, twin coat hook, door stopper, gravity hinges, and locking arrangement, SS chanel etc as desired. all complete as per architectural drawing and direction of Engineer in charge. (A)Cubical size =1050x1500mm,Cubical Height =2100mm,External Laminate finish- Mettallic) "L TYPE"
Providing and fixing Toilet cubicals as under with door, pilaster and divider of Titan 12mm thick Box-UP Series Merino/Greenlam or equivelent make board both side decorative high pressure laminates (HPL) of required colour ,shade and sizes including stainless steel accessories ( SS-304 grade) like square top rail, box, knob, thumb turn and indicator, twin coat hook, door stopper, gravity hinges, and locking arrangement, SS chanel etc as desired. all complete as per architectural drawing and direction of Engineer in charge. (A)Cubical size =1050x1500mm,Cubical Height =2100mm,External Laminate finish- Mettallic) "I TYPE"
(SH: STEEL WORK)
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. a) Using M.S. angels 40x40x6 mm for diagonal braces
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. a) 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Extra for providing mechanical device chain and crank operation for operating rolling shutters. a) Exceeding 10.00 sqm and upto 16.80 sqm in the area.
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. a) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. a) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing Built up sections/Rolled steel MS sections/Builtup tubular sections of approved make structural steel plate fabricated section, testing, cutting, fabrication, welding to the required Profile, shape and size as per approved structural drwaings for Structural Steel Column / Steel Beams / Bracing Works & Staircase Works etc complete made of Grade E350 conforming to IS 2062 - 2006, BSEN - 4, IS: 4923 - 1997, IS: 1239 - 2004 and IS: 1611 - 1960 including shop fastening members with a coat of anti rust primer after cleaning/shot blasting ( when ever required). The work shall be carried out strictly in accordance to structural drawing, specification and as per directions of Engineering in charge. The structural steel shall conform to IS : 226 / 2062 - and shall be of TATA / SAIL / JSW / JSPL make.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. a) 10 x 80 mm
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : a) 4.0 mm thick glass panes.
Deck Sheet
Supplying and laying cold roll formed galvanized rofiled sheet of Tata/JSW/ Smartdek with the following specification: Base metal thickness of decking shall be 1.00 mm thick (11.34 kg/sqm) manufactured using S350 grade of steel with total galvanization of 275 gsm on both sides. The decking is produced in minimum of 60 mm profile depth. The decking is profiled with indentations to achieve adequate bonding with concrete to act as a composite deck complete as per direction of the Engineer-in-charge.
(SH: FLOORING WORK)
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. a) 18 mm thick
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (a) 25 mm thick.
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Extra for pre finished nosing to treads of steps of marble stone.
Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre.
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Size of Tile 1000x1000 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
Size of Tile 600x600 mm
Size of Tile 1000x1000 mm
Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Light shade pigment using white cement.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (a) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: (a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. (b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge.(c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. (a) 700 mm Finished Floor Height (FFH).
(SH: ROOFING WORK)
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : (a) In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
75 mm diameter
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Coupler- 110 mm
Bend 87.5°- 110 mm bend
Shoe (Plain)- 110 mm Shoe
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval,
including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, pecification and direction of the Engineer in Charge but excluding the cost of painting with : (a) 12.5 mm thick tapered edge gypsum moisture resistant board
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-incharge.
(a) With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6
(SH: FINISHING WORK)
12 mm cement plaster of mix : (a) 1:6 (1 cement: 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix : (a) 1:6 (1 cement: 6 coarse sand)
20 mm cement plaster of mix : (a) 1:4 (1 cement: 4 coarse sand)
6 mm cement plaster of mix : (a) 1:3 (1 cement: 3 fine sand)
Neat cement punning.
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
White washing with lime to give an even shade : (a) New work (three or more coats)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : (a) New work (two or more coats) over and including water thinnable priming coat with cement primer.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. (a) With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: (a) New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. (a) Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
Applying priming coat:
With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
Providing and applying two coats of fire retardant paint on cleaned wood / ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : (a) Two or more coats on new work.
French spirit polishing : (a) Two or more coats on new works including a coat of wood filler.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : (a) Two or more coats on new work.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
(SH: REPAIRS TO BUILDING WORK)
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : (a) 3 mm thick
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
(SH: SANITARY INSTALLATIONS WORK)
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and Fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm PTMT waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : (a) White Vitreous China Wash basin size 550x400 mm with single PTMT pillar cock.
Providing and Fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.
Kitchen sink with drain board 510x1040 mm bowl depth 200mm.
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineerin- charge.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing
Rectangular shape 1500x450 m
Providing and fixing toilet paper holder .
C.P. brass
Providing and Fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality colour and make, weighing not less that 105gms
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Soil, Waste & Vent Pipes
Providing and fixing uPVC pipes type -B of Supreme, Astral, apollo or equivelent make conforming to IS 13592 (1992) for soil, waste and vent pipes including all fittings rubber ring type (plain or with access door) e.g. bends, junctions, cowls, offsets, access pieces, jointing with rubber ring joints with lubricant etc. fixed with clamps to walls with cement concrete 1:2:4 blocks complete as per directions of Engineer-Incharge.
Providing and fixing the following uPVC pipes of Supreme, Astral, apollo or equivelent make conforming to IS: 4985 of 6 kg/sqcm for drainage system cut to required length to be laid under floor including covering all around with cement concrete and making good the same complete as per directions of Engineer-Incharge.
Providing and fixing uPVC, P or S trap of self cleansing design with / without vent. arm Setting in cement concrete 1:2:4 mix complete including cost of cutting & making good the Wall / Floors wherever required complete as per directions of Engineer-Incharge.
110 mm inlet & 110 mm outlet
Providing and fixing PVC inlet fitting with one or more inlets fabricated from 110 mm outer dia UPVC pipe and solvent welded sockets and fixed to UPVC Trap and set in cement concrete as per drawing complete
Providing and fixing floor drain with supporting clamp ceiling or in sunken portion including cutting and making good the walls and floors wherever required complete as per directions of Engineer-Incharge. a) 110 x63mm outlet
Providing and fixing SS grating of approved quality including cutting and making good the walls and floors wherever required complete as per directions of Engineer-Incharge. (size 5" dia)
Providing and fixing End plug of approved quality including cutting and making good the walls and floors wherever required complete in all respects .
(SH: WATER SUPPLY WORK)
Providing and Fixing chlorinated Polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
15mm dia nominal bore
20mm dia nominal bore
25mm dia nominal bore
32mm dia nominal bore
Providing and Fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work).
15mm dia nominal bore
20mm dia nominal bore
25mm dia nominal bore
32mm dia nominal bore
40mm dia nominal bore
50mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work
15 mm dia nominal bore
20 mm dia nominal bore
25 mm dia nominal bore
32 mm dia nominal bore
40 mm dia nominal bore
50 mm dia nominal bore
65 mm dia nominal bore
80 mm dia nominal bore
Providing & fixing brass stop cock of approved quality .
15mmdia nominal bore
20mmdia nominal bore
Providing and fixing gunmetal gate valve with CI wheel of approved quality (Screwed end)
25mm nominal bore
20mm nominal bore
32mm nominal bore
40mm nominal bore
50mm nominal bore
65mm nominal bore
80mm nominal bore
Providing and fixing gun metal non-return valve of approved quality (screwed end) :
65 mm nominal bore
Horizontal
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve,with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominalsize ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :
With common burnt clay F.P.S (non modular)bricks of class designation 7.5
Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Painting GI pipes and fittings with enamel white with 2 coats of paint over a ready mixed priming coat, both of approved quality for new work.
15mm dia nominal bore
20mm dia nominal bore
25mm dia nominal bore
32mm dia nominal bore
40mm dia nominal bore
50mm dia nominal bore
Providing and fixing forged brass auto air vent valve 10 PN rating of Castle, Sant, Zoloto or equivelent make including all fitting & accessories complete as per directions of Engineer-Incharge.
Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Rectangular tank
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
15 mm nominal bore
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15mm nominal bore
Providing and fixing of 600mm long stainless steel grab bar of Jaquar, Cera, Bobrick or equivelent make fixed with screw etc complete as per directions of Engineer-Incharge.
Providing and fixing C.P. cast brass twin coat hooks of Jaquar, Cera, Bobrick or equivelent make fixed to wooden cleats with C.P. brass screws etc complete as per directions of Engineer-Incharge.
Providing and fixing Automatic Hand Dryer 235 x 205 x 265 mm (stainless steel) of Jaquar, Cera, Bobrick or equivelent make with wooden cleats and C.P. brass screws including cutting and making good the wall wherever required complete as per directions of Engineer-Incharge.
Providing and fixing 15mm C.P brass mixer of Jaquar, Cera, Roca or equivelent make fitting for kitchen sink with swivel spout with connecting legs and wall flange including cutting and making good the walls wherever required complete as per directions of Engineer-Incharge
Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by muncipal board complete with bolts,nuts, insertions etc.(The tails pieces if required will be paid separately)
80 mm dia
100 mm dia
150 mm dia
Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373
80 mm dia
100 mm dia
150 mm dia
(SH: DRAINAGE WORK)
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete
150 mm diameter
200 mm diameter
250 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:
150mm dia SW pipe
200mm dia SW pipe
250mm dia SW pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of R.C.C. pipes including bed concrete as per standard design :
150 mm diameter
250 mm diameter
300 mm diameter
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
150x100 mm size P type
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
150 mm diameter
250 mm diameter
300 mm diameter
Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg):
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes :Size 90x80 cm
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
0.91 mm deep with SFRC Cover and frame (heavy duty , HD- 20 grade designation) 560 mm internal dia confirming of to I.S 12592 total weight of cover and frame not less than 182.Kg. fixied in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone agggregate 20 mm nominal size ) including centering shutering all complete.(Excavation,foot rest and 12 mm thick plaster at the external surface shall be paid for separately)
with common burnt clay F.P.S.(non module) brick of class designation 7.5
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m.
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
1.68 mm deep with SFRC Cover and frame (heavy duty , HD- 20 grade designation) 560 mm internal dia confirming of to I.S 12592 total weight of cover and frame not less than 182.Kg. fixied in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone agggregate 20 mm nominal size ) including centering shutering all complete.(Excavation,foot rest and 12 mm thick plaster at the external surface shall be paid for separately)
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar.
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality,H D - 20,Circular shape 560 mm internal diameter.
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :
with common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.
450 mm dia pipes
Providing and laying UPVC pipes (I.S:4985) of 8kg./cm2 of Supreme, Astral , apollo or equivelentmake including all fittings with or without access door i.e. bends, junctions, cowls, offsets, etc., and jointing with solvent cement and excavation, refilling and disposal of surplus earth, including cutting holes in walls and floors,wherever required and making good the same, complete as directed by the Engineer-In-Charge. (For External garden hydrant Pipes only):
25 mm (OD) pipes
32 mm (OD) pipes
40 mm (OD) pipes
50 mm (OD) pipes
(SH: PILE WORK)
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tubewell boring machine shall not be used .
450 mm dia. Piles
500 mm dia. Piles
600 mm dia. Piles
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.Single pile above 50 tonne and upto 100 tonne Safe capacity
Initial test (Test Load 2.5 times the Safe capacity)
Routine test (Test Load 1.5 times the Safe capacity)
(SH: ALUMINIUM WORK)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion: Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (a) With stainless steel cover plate minimum 1.25 mm thickness
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing Pull Handle back to Back (Article code: 903.05.700) Hafele/Dorma/Godrej & Boyce or equivelent makes of Fixing 25mm dia x300mm c/c, SS Matt with necessary screws etc. complete as per direction of Engineer-in-Charge.
Providing and fixing Corner Patch Lock With Cylinder (Article code: 981.50.030) Hafele/Dorma/Godrej or equivelent makes, SS Matt with necessary screws etc. complete as per direction of Engineer-in-Charge.
External Structure Glazing
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. (all heights as per required.)
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating .principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025. 1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.204) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge.
Aluminium Toughened Glass Door & Window
Providing and fixing Powder coated aluminuim framed glazed doors & window with powder coated aluminium frame made of 63mm x 38mm x 2.5mm section of approved brand with door style of size 50mm x 45mm x 2.0mm, top rails 50mm x 45mm x 2.5mm, middle rail 100mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, cleat etc complete as per direction of Engineer-in-Charge. (a) 6mm Toughened glass.
Aluminium Sliding Door
Providing and fixing coloured Powder Coated aluminium sliding glazed doors Shutter with Powder coated aluminium frames made of 100mm x 45mm x 2mm section of approved brand with door style of size 81mm x 45mm x 2mm, top rails 55mm x 45mm x 2mm, lock rails 81mm x 45mm x 2mm, fitted with glazing clip, special type rubber gasket including roller, tower bolt, aluminium door handle, lock, cleat etc. complete as per direction of Engineer-in-Charge. (a) 12 mm thick Prelaminated Board.
Aluminium Louvers Door
Providing and fixing coloured Powder Coated aluminium louver doors Shutter with Powder coated aluminium frames made of 100mm x 45mm x 2mm section of approved brand with door style of size 81mm x 45mm x 2mm, top rails 55mm x 45mm x 2mm, lock rails 81mm x 45mm x 2mm, fitted with glazing clip, special type rubber gasket including roller, tower bolt, aluminium door handle, lock, cleat etc. complete as per direction of Engineer-in-Charge.
Control Tower
Providing and fixing fixed frameless glazing including providing 12mm thick clear float toughened glass as manufactured by Asahi / Modi Guard / Saint Gobain or equivalent make . The perimeter of Frameles Fix glazing shall be grouted in the Masonry / RCC / Stone as per respective location, by using a channel of 19mm X 25mm height X 2.0 mm thick.The channel shall fixed rigdly to masonry, inserting PVC sleeves and fixing with 10 X 50mm long (or as per requirement) stain less steel wooden screw at a spacing of 25mm from the edges and 100mm centre to centre. EPDM flat profile (12mm wide X 20mm height) as manufactured by the Bohra Rubbers / Hanu Industries or equivalent make should be provided on top and bottom of the the glass as required. The glass should be fixed in line and plumb with a minimum gap of 8mm between glass to glass and filled with clear Weather Sealant of Dow Corning or GE Silicones or approved equivalent make , The gaps between both side of the channel and the glass should be inserted with bond breaking backer rod of 6mm Dia as manufactured by Supreme Industries equivalent make , shall be applied with clear weather sealant of Dow Corning Or GE Silicones. All the perimeter gaps between the channel and Masonry work includes supply installation of toughened high performance glass of thickness 12mm as per ST - 467of Saint Gobain/ Modi/ Asahi Glass or equivalent including of sealants, brackets, fasteners, screws, sieve, backer rod, bolts, gasket, fixtures, etc. complete as per direction of Engineer-in-Charge.
Partation Work
Providing and fixing in position opaque partition consisting of frame work in extruded aluminium sections 1.6mm th, of approx size 50 x 50 mm,placed at center to center at not more than 600 mm both ways, joined using angle 35 x35x3 mm.Securly fixed to wall and, floor and celling complete in all respecty. The rates shall be inclusive of cutting,punching of holes for drawings conduits and boxes for electical works etc. Providing and fixing to aluminum frame work ,12mm thick Exterior Grade MDF Fixed with fully threaded parallel shank screws at 200 to 300 mm centre to centre both ways on the framework. Joints staggered on either sides of the partitions to avoid through joints complete as per architectural drawings as per direction of the engineer in charge. Providing and fixing Second Skin of 6mm thick Exterior grade MDF board on existing straight partition Fixed with suitable adhesive & fully threaded parallel shank screws at max. 230mm c/c both ways. Joints staggered on either sides of the partitions to avoid through joints. Providing grooves of size 6mm x 6mm complete as per architectural drawings as per direction of the engineer in charge . Providing and fixing infill of 50mm thick & min. 60 kg / m3 density Mineral Wool Insulation. Mineral wool packed in polyweave packets inside partition frame work fixed to wall with Clip, screw, rawel plug & washers and held in position by criss cossing GI wire etc. complete as per directions of Engineer-in-Charge. Providing and fixing in 1.0mm thick laminate sheet on bothg side of partition, of required size and pattern, & colour over full height fixed with adhesive of approved quality complete as per directions of Engineer-in-charge.
Providing and fixing of frameless Automatic bi-parting sliding door for clear opening (size 2000x3150)mm modular design, including internal cover, eagle sensors on both sides, Electro mechanical lock, light barriers and programmer switch complete, With Operator Dimensions (L x H x T): not exceeding 4200x190x100 mm. The track profile should be separate from the main profile for enabling reduction in vibration. Microprocessor control unit, it should be self-learning, reversing when obstruction is encountered. Microprocessor-controlled control unit. It should be Self-learning, with adjustable parameters for opening and closing speed, hold-open time and opening and closing force. Class of protection IP 20. The glasses shall be of 12mm clear toughened frameless with polished edges. The system shall have constant power supply 230V, 50/60Hz (by others), for various opening sizes all complete as per design and direction of Engineer-in-Charge.
Providing and fixing 3MTM Scotchal electro cut Dusted /Crystal ( acid -etched look ) 7725SE-314/324 Graphic Film over the designated locations shown in the drawing in any design and pattern etc. complete as per the direction of the Engineer-In-Charge.
(SH: WATER PROOFING WORK)
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.(The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)
Providing and laying on sunken areas broken light weight Autoclaved aerated concerete broken blocks of approximately 600 kg/cum density laid, consolidated, finished smoth, including finishing and grouting the top layer with water proof cement mortar 1:6 (1 cement : 6 fine sand) with water proofing compound as per specifications compelte as per directions of Engineer-in-Charge.
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Serrated with central bulb (225 mm wide, 8-11 mm thick)
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
For vertical surface two coats @ 0.70 kg per sqm
For horizontal surface one coat @1.10 kg per sqm.
Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage.
(SH: ROAD & PAVEMENT WORK)
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density).
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts,spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer in-Charge.
With material conforming to Grade-I (size range 75 mm to 0.075 mm ) having CBR Value-30
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve gap the desired density, complete as per specifications and directions of Engineer-in-Charge.
Construction of dry rolled lean cement concrete sub base over a prepared subgrade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications,cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-incharge.
Laying and spreading a layer of sand 6 mm thick (average) over dry rolled lean concrete layer including the cost of sand but including removal of pebbles, rubbish etc. by screening if required etc complete, as directed by the Engineer in charge.
Providing and laying transparent Ist quality polythene sheet sepration membrene of 400 microns thick on the base course with overlaps of not less than 100mm longitudinally and 150mm transversely as per specification and as direction of Engineer-in-charge.
Providing and laying Pavement Quality Concrete (PQC) produced in a batching plant having a Characteristic flexural strength i.e. minimum flexural strength of 4.1 MPa at 28 days using 350 Kg of ordinary Portland cement of 43 grade per cum of finished concrete, fine aggregate, graded stone aggregates of 40 mm nominal size in appropriate proportion as per specification and job mix formula, laid in panels as per drawings/design as approved by the Engineer-In-Charge using normal method including making necessary provision for expansion joint, curing, etc. complete as per direction of Engineer-in-Charge and particular specifications. The item for execution shall also include the following operations: i) Mechanically cutting dummy joints 3mm wide x 1/3rd thickness of slab which is subsequently widened to 10mm for the top 25mm depth and construction joints 10mm wide x 25mm deep as per specification. ii) Filling Polysulphide sealant in dummy, construction and expansion joints including providing closed-cell Polyethylene foam back-up rod, and painting side of joints with Polysulphide primer, etc. complete (to be paid separately under revelant item). Note:- i) Cement content considered in is @ 350 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately Note:- ii) Prior to start of work the job mix for PQC shall be got designed by the agency from the laboratory approved by AAI and the cost of mix design shall be borne by the agency and nothing extra is payable on this account.
Providing and laying in position polysulphide sealant of approved make conforming to BS-5212-1990 or IS 11433-1995, in expansion / Construction / dummy joints including rounding of edges applying 2 coats of approved primer compatible with the brand of polysulphide and preparing the surface and applying masking tape along the edge of joints to prevent accidental spillage of sealant on top surface and to give neat finish to the sealant and removing the masking tape after application of sealant etc. complete as per direction of Engineer-in-Charge & particular specifications. [note : for purpose of payment, quantity (Length X Width X Depth) of sealant only will be measured.] i) Expansion joints of size 25 mm wide and 10 mm deep over 30mm dia. Closed-cell Polyethylene foam back-up rod, as per manufacturers specifications and sketch at Appendix-'A'. ii) Construction joints of size 10 mm wide and 10 mm deep over 12 mm dia Closed-cell Polyethylene foam back-up rod, as per manufacturers specifications and sketch at Appendix-'A'. iii) Dummy joints of size 10 mm wide and 10 mm deep over 12 mm dia. Closed-cell Polyethylene foam back-up rod, as per manufacturer's specifications and sketch at Appendix-'A'.
Providing and laying in position for expansion joint, 25mm thick pre-cut synthetic joint filler board of approved make conforming to IS: 1838 (part 3)-2011, 45 mm from top (to be removed at the time of filling of polysulphide sealant), complete as per particular specifications and direction of Engineer-in-Charge. (Note :- Mode of measurement shall be lenght of joints multiplied by depth of filler board including precut portion.
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately).
Painting road surface marking with adequate no. of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white / yellow shade including cleaning the surface of all dirt, scales, oil, grease and foregin material etc. complete. (a) New work (Two or more coats)
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block makingmachine with strong vibratory compaction, of approved s;ze, design& shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sandetc. all complete as per the direction of Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature,jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge.
Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading,well ramming, consolidating and grouting with jamuna sand, includingfinishing smooth etc. complete as per direction of Engineer-in-charge.
ELECTRICAL WORKS
OUTGOING - '2 No. 630 Amp., 11kV VCB. 02 Nos.' Aux. relays for Anti Pumping & indication. 02 Nos.Trip Circuit spervision relay '- 02 Nos.Master Trip Circuit Relay 2 Nos. of over current & short circuit 51,51N & one earth fault element with numerical IDMT relay with shunt trip on 24volts DC, on RS 485 modbus communication consisting 2 element over current relay and earth fault relay for Over & under voltage, Over & under frequency , CT & VT supervision facility , min. 250 events & 25 faults recording, with min 5 pre & post disturbance recording and 2 Nos of Master trip relays. 2 Nos - Multifunction Meter with 7 LED display of I ;V; Hz; Active, Reactive , Apparent Power & Energy; Power factor; % unbalance of current & voltage; calculated neutral current ; %TDH , individual harmonics up to 15th level (complying with IEC61557-12) and protection Fuse 'Alarm annunciator with 8 windows and buzzer, ACK, rest, test push button for transformer faults and electrical faults in respective window. '1 set of Dual core 3 CTs 40/5A of 15VA burden and accuracy Class -1.0 for metering and class 5P10 for protection. One (1) no. 630A 11kV Buscoupler Breaker have following Accessories & indication ' 1 No. 630 Amp., 11kV VCB Set of ON/OFF/TRIP indicating lamps. Clear lamp for Trip Circuit healthy supply. Aux. relays for Anti Pumping,Fault & indication. Trip Circuit spervision relay. Master Trip Circuit Relay
OIL TYPE OUTOOR TYPE TRANSFORMER Supply, Installation, Testing & Commissioning of Oil type 11KV/0.433KV, 630 KVA Dyn11 outdoor Oil cooled Copper wound Distribution Transformer with OLTC (tappings +5% to -10%, in steps of 1.25%) with RTCC on HT side, having cable end boxes on HV side suitable for 3C x 185 sq.mm. XLPE cable of 11kV grade and cable box arrangement of LV side with neutral brought out separately , supplying and grouting of suitable MS channels with all accessories for mounting arrangement of incommer and confirming to IS 2026 (Part 1 to Part 5) & as per specification attached complete in all respects as required at site. The transformer shall be supplied with following Fitting & Accessories: All standard fitting viz Humidistat for Alarm and Trip Transformer Oil Temperature Alarm & Tripping Winding temperature relay unit with Alarm and trip Oil Level Low Alarm with trip Electronic temperature controlled with RTD. Gas Pressure Relays Outdoor type Marshalling box with RS-485 communication port for BMS integration to monitor all transformer parameters or having 2 No. potential free contact for alram, trip & annunciation (one for BMS and one for control system). The transformers shall have bi-directional rollers, winding temperature indicator and oil temperature indicator with wiring up to the marshalling box complete. The transformers shall have first filling of oil, weather proof HT cable box. The transformer shall have suitable disconnecting chamber at the ends with min 8mm thick non-magnetic gland plate , including M. S. channel and suitable size foundation complete with earth terminals / lifting lugs and other standard accessories as required, as per relevant IS to successfully test & commission the Power Transformer as described above and technical specification.
SUPPLY OF HT CABLES Supply of following sizes of XLPE insulated PVC sheathed aluminium conductor armoured power cable of 11 kV grade conforming to IS 7098 (Part-II) amended upto date. 3 Core, 185 Sq.mm. (E)
LAYING OF 11 KV GRADE HT CABLES Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. Above 120 sq. mm and upto 400 sq. mm
CABLE END TERMINATION
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 240 Sqmm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 240 Sqmm
BATTERY CHARGER & BATTERIES Supply, installation, testing and commissioning of 24 V, 15AMP Battery Charger & suitable numbers of 2V 100 AH maintance free batteries, Battery Charger shall be solid state, full wave fully controlled bridge, input suitable for three phase four wire 415V +/- 10% AC suppply, conforming to degree of protection IP-42, Sheet steel enclosure 1.6mm thick, with automatic voltage regulation, current limiting circuitary, auto cut facility, smooth filter circuit switches, Ammeter & voltmeter on DC side, phase indicating lamps (LED type) on AC side complete in all respect with switchgear, earthing, powder coated painting etc as required. The battery charger shall have electronic health module which will monitor and indicate the health of connected batteries regularly. Suitable Iron angle stand for 2V, battery bank shall be provided.
DG SETS & ACCESSORIES Supply, installation, testing and commissioning of 750 KVA Silent type, radiator cooled D.G Set with DG set microprocessor based controller module mounted on DG set having inbuilt metering & protection, communicable port (RS485) etc. and acoustic enclosure conforming to latest environment protection regulations for emission and noise levels complete with Diesel Engine of suitable BHP (considering de-rating factor if any) at 1500 RPM, four stroke, electric start, turbo-charged conforming to relevant BS & IS standard with all standard accessories, coupled with Alternator of 750 KVA rating, brushless, self excited, self regulated and suitable for continuous operation, generating 415 V ±5% Volts at 0.8 PF (lag), 50Hz, 3 phase, 4 wire system generally conforming to BS: 2613 & IS: 4722. Both Engine and Alternator shall be mounted on common channel M.S base frame, with required fuel pipe line , foundation as per OEM recommendations, Anti vibration mountings, residential type silencer, electric starter, batteries & battery charger, fuel tank of 990 Itrs. capacity with level indicator including required power cable for ventilation fan if any, other standard accessories etc complete as required as per Technical specifications.
EXHAUST PIPE Supplying and fixing of exhaust gas piping of for 750 KVA rating D.G. Set welded black MS, 'B' Class pipe conforming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, the work include necessary cladding of exhaust pipe work using wiremesh, 50mm thick Loosely bound resin(LBR)mattress / mineral wool/ Rockwool, density not less than 150kg/m and aluminium cladding (0.6mm thick min.) for temperature up to 450°C, complete portion complete as required as per specifications.
350mm (NB) MS ERW pipe 5.0mm thick
250mm (NB) MS ERW pipe 5.0mm thick
Suplly and fixing of miscellaneous structural support for horizontal/vertical exhaust piping including fabrication, hardwares and apainting as per specifications.
Supply & Fixing of SS Expension joints for horizontal/ vertical exhaust piping as required at site: 350 mm exhaust SS Bellows (200mm Long)
CONTROL CABLE & TERMINATION: Supplying of following sizes of 1.1 kV grade PVC insulated copper conductor armoured stranded Control Cable conforming to IS :1554 complete as required and as per specifications.
4 core, 2.5 Sq.mm. Cu. Conductor cable
7 core, 2.5 Sq.mm. Cu. Conductor cable
12 core, 2.5 Sq.mm. Cu. Conductor cable
19 core, 2.5 Sq.mm. Cu. Conductor cable
Supply and making end termination with brass Double compression gland and Copper thimbles for XLPE insulated and PVC sheathed copper conductor cable of 1.1kv grade of the following sizes as required.
4 C x 2.5 Sq.mm.
7 C x 2.5 Sq.mm.
12 C x 2.5 Sq.mm.
19 C x 2.5 Sq.mm.
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE Power cable of 1.1kV grade of following sizes on existing cable tray etc. as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
EARTHING (SUB-STATION EQUIPMENTS & DG SET)
Earthing with copper earth plate 600mm x 600mm x 3.0mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal and salt complete as required.
Earthing with GI earth plate 600mm x 600mm x 6.0mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal and salt complete as required.
Providing & fixing of 50mm x 5mm GI strip on surface or recess for earth connection as required.
Providing & fixing of 50mm x 5mm copper strip on surface or recess for earth connection as required.
Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the GI/Copper Strip for protection as required.
SAFETY EQUIPMENTS
Supplying of Rubber hand gloves suitable for 11 kV.as per IS Standard
Supplying and fixing of Shock treatment chart both in Regional, Hindi & English.and framed with 5mm thick glass as required.as per IS Standard
Supply & fixing HT danger notice plate of 250 mm x 200mm, made of mild steel sheet of at least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour on front side as required. (11 kV)as per IS Standard
Supply & fixing MV danger notice plate of 200 mm x 150mm, made of mild steel sheet of at least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour on front side as required.as per IS Standard
Supply of First aid box containing material as prescribed by St. John Ambulance brigade OR Indian Red Cross conforming to IS 2217-1963 complete as required.
Supply and fixing of 12 KV grade class C nominal 3.0 mm ± 10% thick insulated with 1 mtr wide synthetic Mat conforming to IS 15652:2006 and meeting the requirments of IS 5216 (Part 1, 2 & 3) IS 8437, IEC-179 Pub-1, along-with suitable adhesive / chemibound, PU resin, waterproffing compound and celing material as per recommendition of the manufacturaer and as per specifications and direction of Engineer-in- charge.
Supply and fixing of 3.3 KV grade class C nominal 2.0 mm ± 10% thick insulated with 1 mtr wide synthetic Mat conforming to IS 15652:2006 and meeting the requirments of IS 5216 (Part 1, 2 & 3) IS 8437, IEC-179 Pub-1, along-with suitable adhesive / chemibound, PU resin, waterproffing compound and celing material as per recommendition of the manufacturaer and as per specifications and direction of Engineer-in- charge.
Providing Single Line Diagram on 5mm thick Aluminium sheet in A0 Size duly laminated.as per IS Standard
Providing Single Line Diagram on 5mm thick Aluminium sheet in A1 Size duly laminated.as per IS Standard
Providing and fixing HT Danger notice plate of 200mm x 150mm, made of mild steel, at least 2mm thick, at vitreous enameled white on both sides, and with inscription in single red colour on front side as required.as per IS Standard
Caution board printed in signal red "Man on Line".
Caution board printed in signal red "Don’t switch on".
HSD SYSTEM Supply, installation, testing & commissioning of Calibrated HSD buffer/service tank, rectangular MS (IS:226) construction with 990 liters capacity complete with flanged inlet & outlet, overflow, drain, vent, mechanical level indicator, 450mm dia Access hole on top with cover, flame arrestor. Tank will be made out of 3mm MS sheet and will be provided with structural support to keep tank base at (2000mm) above FFL with access ladder arrangement, painting etc. complete as required.
Supplying, installation, testing & comissioning of MS pipes of heavy class ERW piping (Class-C) conforming to IS 1239 of following sizes and materials cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mounting, etc but excluding valves, strainers and gauges etc. adequately supported on rigid supports / concealed on floor, painting with two coats of synthetic enamel paint after primer coat etc. complete as required. 25 mm
Supply , installation, testing & comissioning of following sizes of Ball Valve of brass body, PN-16 rating, Teflon sealing, stainless steel handle, screwed ends etc complete as required. 25 mm
Providing, Fixing, Testing and Commissioning of HSD Oil Y-strainer of 50mm dia, CI body, SS strainer, flanged ends etc complete as required. 25 mm
63A 4P RCBO (30mA) RCBOs in powder coated MS Enclosure (For Lifts) Supply, Installation, Testing and Commissioning of cubicle typeMS Enclosure, IP42, suitable for AC supply system fabricated from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade as per direction of E.I.C
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way , Double door
8 way , Double door
12 way , Double door
Supplying and fixing following way prewired per phase isolation TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, cable tray adapter box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, 200A tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. and suitable for 8 moudle incomer , 12/6 moudle subincomer & SPMCB as outgoing as required.(But without MCB/ RCCB/ Isolator).
4 way (8 + 12 + 12) , Double door
6 way (8 + 12 + 18) , Double door
8 way (8 + 12 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
Double pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 30mA 240 volts, RCBO complete with connections, testing and commissioning etc. as required in the DP MCB DB.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
For 6 way, Double door SPN MCBDB
For 8 way, Double door SPN MCBDB
For 12 way, Double door SPN MCBDB
Supply of following size of 1.1kv grade multicore aluminium conductor XLPE insulated and PVC sheathed armoured cable as per IS: 7098:1988 (Part - I) with upto date amendments.
3.5 core, 300 Sq.mm.
3.5 core, 240 Sq.mm.
3.5 core, 185 Sq.mm.
3.5 core, 150 Sq.mm.
3.5 core, 120 Sq.mm.
3.5 core, 95 Sq.mm.
3.5 core, 70 Sq.mm.
3.5 core, 50 Sq.mm.
3.5 core, 35 Sq.mm.
4 core, 25 Sq.mm
4 core, 16 Sq.mm
Supply of following size of 1.1kv grade multicore copper conductor XLPE insulated and PVC sheathed armoured COPPER cable as per IS : 7098:1988(Part - I) with upto date amendments.
4 core, 10 Sq.mm
4 core, 6 Sq.mm
3 core, 10 Sq.mm
3 core, 6 Sq.mm
Supply of following size of 1.1kv grade Fire Survival multicore Aluminium/copper conductor XLPE insulated and PVC sheathed armoured cable as per IS : 7098 with upto date amendments.
3.5 core, 185 Sq.mm. Al (Fire Survival )
3.5 core, 50 Sq.mm. Al (FS)
4 core, 10 Sq.mm. Cu (FS)
4 core, 6 Sq.mm Cu (FS)
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE Power cable of 1.1kV grade of following sizes on existing cable tray etc. as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required
Upto 35 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5 core, 300 Sq.mm. AL Cable
3.5 core, 240 Sq.mm. AL Cable
3.5 core, 185 Sq.mm. AL Cable
3.5 core, 150 Sq.mm. AL Cable
3.5 core, 120 Sq.mm. AL Cable
3.5 core, 95 Sq.mm. AL Cable
3.5 core,70 Sq.mm. AL Cable
3.5 core, 50 Sq.mm. AL Cable
3.5 core, 35 Sq.mm. AL Cable
4 core, 25 Sq.mm. AL Cable
4 core, 16 Sq.mm. AL cable
Supply and making end termination with flame proof brass compression gland and Copper thimbles for XLPE insulated and PVC sheathed copper conductor cable of 1.1kv grade of the following sizes as required.
4 core, 10 Sq.mm. copper cable
4 core, 6 Sq.mm. copper cable
3 core, 10 Sq.mm. copper cable
3 core, 6 Sq.mm. copper cable
Supplying and making end termination with brass compression gland and Aluminium/Copper lugs for following size of Fire Survival Cable of 1.1 KV grade as required.
3.5 core, 185 Sq.mm. Al (FS)
3.5 core, 50 Sq.mm. Al (FS)
4 core, 10 Sq.mm. Cu. (FS)
4 core, 6 Sq.mm. Cu. (FS)
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
100 mm dia
150 mm dia
250 mm dia
300 mm dia
CABLE TRAY Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
600 mm width x 62.5 m depth x 2 mm thickness.
450 mm width x 62.5mm depth x 2 mm thickness.
300 mm width x 62.5mm depth x 2 mm thickness.
150 mm width x 50mm depth x 1.6 mm thickness.
Supply and installing following size of galvanised iron Lader type cable trays with radil bends supports, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with GI suspenders etc as required. 750 mm width x 62.5 mm depth x 2 mm thickness.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
2 x 1.5 + 1 X 1.5 sq. mm earth wire
2 x 2.5 + 1 X 2.5 sq. mm earth wire
2 x 6 + 1X 6 sq. mm earth wire
4 x 2.5 + 2X 2.5 sq. mm earth wire
4 x 6 + 2X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing of following sizes of steel conduit along with accessories in surface / recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as required.( For ELV System)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Telephone socket outlet
TV antenna socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (75mmX75mm)
Supply and fixing of pop up box (floor mounted) on floor including connection & all accessories etc. as required. (For Blank Module Space for 2NOs. 6A SOCKET&SWITCH +1NO.6A SOCKET & SWITCH +1NO. TELEPHONE SOCKET+1NO.Data SOCKET)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 40A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 63A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supply, assembly and laying of under floor trunking made out of 1.6mm thick GI sheet complete with jointing sleeve, horizontal bends, vertical bends, level adjustment components and closer, vertical elbow, covers, access outlet. etc. complete with all other accessories under floor installation including cutting and chasing the floor/ or on surface, making good the same, placing in position and cleaning from inside complete etc. as required
300 mm wide x 38 mm deep raceway (2 compartment)
150 mm wide x 38 mm deep raceway (1 compartment)
100 mm wide x 38 mm deep raceway (1 compartment)
Providing and fixing following size GI (hot dip galvanized) raceways made out of 1.6 mm thick sheet steel junction box complete as requried as per specification.
100 x 100 x 60-75 mm deep
150 x 150 x 60-75 mm deep
300 x 300 x 60-75 mm deep
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories,and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm GI strip in 40 mm dia G.I. pipe from earth electrode including connection with GI nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing & fixing of 25mm x 5mm GI strip on surface/ recess / cable tray for connection etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
150 mm inner dia
100 mm inner dia
80 mm inner dia
50 mm inner dia
Supplying and laying of following size Type 450/Code 450 DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 16205, Part 24 complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Supply, installation, testing & commisioning of Vertical Electrolytic Lighting Arrester of 10 mm (minimum) dia.and 1mtr (minimum) long with base plate . The component shall be tested as per requirement of IS/IEC 62305 & IEC 62561-2 from reputed NABL Lab.
Supply, installation, testing & commisioning of 8 mm (minimum) round aluminium conductor for horizontal lightning protection - run in parapet .The component shall be tested as per requirement of IS/IEC 62305 & IEC 62561-2 from reputed NABL Lab.
Supply, installation, testing & commisioning of roof conductor holder for 8 mm(minimum) round aluminium conductor made of Gun Metal for horizontal installation. The distance between each holder should be min of 1.5 mtr.The component shall be tested as per requirement of IS/IEC 62305 & IEC 62561-2 from reputed NABL Lab. The component shall be tested as per requirement of IS/IEC 62305 & IEC 62561-2 from reputed NABL Lab.
Supply, installation, testing & commisioning of Cross connector for connecting of 8 (minimum) mm Al round conductor . The connector should be of Gun Metal with SS nuts and bolt. The component shall be tested as per requirement of IS/IEC 62305 & IEC 62561-2 from reputed NABL Lab.
Supply, installation, testing & commisioning of T connector for connecting of 8 mm (minimum) Al round conductor . The connector should be of Gun Metal with SS nuts and bolt.The component shall be tested as per requirement of IS/IEC 62305 & IEC 62561-2 from reputed NABL Lab.
Supply, installation, testing & commisioning of straight connector for connecting of 8 mm (minimum) Al round conductor . The connector should be of Gun Metal with SS nuts and bolt. The component shall be tested as per requirement of IS/IEC 62305 & IEC 62561-2 from reputed NABL Lab.
Supply, installation, testing & commisioning of 8 mm round aluminium conductor as a down conductor mounted in the surface of wall which will carry the lightning current to earth pit. The component shall be tested as per requirement of IS/IEC 62305 & IEC 62561-2 from reputed NABL Lab.
Supply, installation, testing & commisioning of Down conductor holder for 8 mm round aluminium conductor of min distance between the wall to the conductor will be of 50 mm. The distance between each holder should be min of 1 mtr.The component shall be tested as per requirement of IS/IEC 62305 & IEC 62561-2 from reputed NABL Lab.
Supply, installation, testing & commisioning of Test Joint Point for 8 mm round aluminium conductor , the size should be of 25 x 3 x 150 mm copper in ABS boxes.The component shall be tested as per requirement of IS/IEC 62305 & IEC 62561-2 from reputed NABL Lab.
EARTHING AS PER IEC 62561- 2 & 7 Supply, installation, testing & commisioning of UL approved low carbon high tensile steel rod with copper coating of min 250 micron the dia should be 16 mm (minimum) with length of 10 feet(minimum)t. The rod shall be as per IEC 62561-2 and approved by UL 467. The rod shall be tested from NABL lab for current discharge not less then 46kA peak. The Chemrode shall be surrounded with 50 kg ( 2 bag) of Earth enhance materiel comply to IEC 62561-7 and the Chemical resistance value shall not increase more then 0.064 Ωm and same will be tested from NABL lab. -
Supply of Lighting Fixture:
Supply of 4ft Linear LED luminaire delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. The luminaire Housing shall be made of PC & the diffuser shall be of polycarbonate/PMMA. The operating CCT shall be 5700- 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V with L70 Criteria, IP20. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.
Supply of 2ft Linear LED luminaire delivering an initial system lumen of 903 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. The luminaire Housing shall be made of PC & the diffuser shall be of polycarbonate/PMMA. The operating CCT shall be 5700-6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V with L70 Criteria, IP20. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.
Supply of Recess Mounted Round Led Downlighter consuming a system wattage of mimimum 12W & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: Die Cast Aluminium. IP20 , Optics: PMMA/Polysterene Diffuser. The operating CCT shall be 5700-6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.
Supply of Recess Mounted Round Led Downlighter consuming a system wattage of minimum 15W & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: Die Cast Aluminium. IP20 , Optics: PMMA/Polysterene Diffuser. The operating CCT shall be 5700-6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacturer along with Photo Biological Safety Standard.
Supply of Recess mounted LED 2'x2' luminaire delivering an initial system lumen of 3300 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: CRCA. Optics: polycarbonate/PMMA/Polysterene, IP20 Protection. The operating CCT shall be 5700-6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.95, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.
Supply of Recess Mounted Linear LED Fixture consuming a system wattage of minimum 20W & the luminaire shall be with system efficacy ≥ 100lm/W. Housing: Extruded Aluminium . IP20 , Optics: PMMA/Polysterene Diffuser. The operating CCT shall be 5700-6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V with L70 Criteria. Cut out Size 60mm X 1188mm. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.
Supply of Bulk Head Luminare delivering an initial system lumen of 600 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: Die Cast Aluminium. IP65 , Diffuser : OPAL Polycarbonate. The operating CCT shall be 5700-6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.
Supply of 6W Exit Light Signage with rechargeable batteries as required.
Supply of AVIATION OBSTRUCTION light to meet ICAO requirements with red colour LEDs, intensity 30 candela in one direction, total intensity 600 candela (Type - L1 - 300) complete with fixing arrangement as per site conditions. etc. complete as required.
Supply of ceiling fan of 1200mm sweep, 5 Star rated (white colour) suitable for operation on 230/240V, 50Hz, single phase, AC Supply complete with double ball bearing motor, down rod of required length, capacitor ,blades etc. as required.
Supply of 1400 RPM, 450 mm ɸ exhaust fan with louvers (Heavy Duty) suitable for single phase 230/240V, AC Supply complete with motor mounting brackets, all accessories complete. As required.
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Supply of 3 mtrs. high GI OCTAGONAL continuously tapered galvanised street light pole for installation of Post top LED luminaire suitable for wind velocity as per IS 875 fabricated out of 3 mm thick High Tensile Steel Sheet in single section, suitable for installation on a precast foundation with supply of 4 nos. of foundation bolt & anchor plate, rigid flange plate (200x200x12mm min.) welded with the base of pole for fixing on foundation bolts complete as reqd. for structural stability as specified, weather proof and vandal resistant door flush with the exterior surface containing a terminal plate of 5 mm thick backlite sheet with 16 Amp heavy duty connector for loop in loop out cable terminations suitable & DP MCB for fixture connections, earthing bolts for continuous earth connection complete as required & as specified. (The top & bottom dia (A/F) of the pole shall not be less than 70mm & 130mm respectively)
Supply of totally enclosed min 22 watt Post top luminaire, Efficiency not less than 110 lumens/watt with lenses, the operating CCT shall be 5700-6500K with CRI of ≥70. consisting of pressure die cast/extruded aluminium housing, heat resistant toughened glass/polycarbonate cover, IP 65, with 4 KV surge protection minimum suitable for operation 230+/-10%, 50 Hz Ac supply with all accessories compete as required
Supply of Bollard Light 5W, Efficiency not less than 110 lumens/watt connection & wiring from junction box.
Supply of Spike Light 6W Efficiency not less than 110 lumens/watt connection & wiring from junction box.
Supply of Step Light 3W, Efficiency not less than 110 lumens/watt connection & wiring from junction box with 3 x 2.5 sqmm copper wires.
Supply of InGround Single Ray Light 7W, Efficiency not less than 110 lumens/watt connection & wiring from junction box with 3 x 2.5 sqmm copper wires.
Supply of Wall Updown Light 2W, Efficiency not less than 110 lumens/watt connection & wiring from junction box with 3 x 2.5 sqmm copper wires.
Supply of Integral Flood Light 18W, Efficiency not less than 110 lumens/watt connection & wiring from junction box with 3 x 2.5 sqmm copper wires.
Erection of 3 Mtr. high OCTAGONAL street light pole i/c all accessories in reinforced cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation of size 40x40x100 cm, including excavation and refilling, positioning of template & foundation bolts (supplied with pole to match with pole base plate) & providing and fixing of HDPE pipe of size 50 mm dia (2 pieces of min. 0.75 m length) in the foundation for loop-in-loop-out of the cable to the pole i/c cable termination etc complete as required.
Installation, testing and commissioning of Post TOP Light on pole connection & wiring from junction box on 3.0 mtr. High G.I octagonal Pole .
Installation, testing and commissioning of Bollard Light connection & wiring from junction box, connection i/c interconnection complete as required.
Installation, testing and commissioning of Spike Light connection i/c interconnection complete as required .
Installation, testing and commissioning of Step Light ,connection i/c interconnection complete as required .
Installation, testing and commissioning of InGround Single Ray Light, connection i/c interconnection complete as required .
Installation, testing and commissioning of Wall Updown Light, connection i/c interconnection complete as required .
Installation, testing and commissioning of Integral Flood Light , connection i/c interconnection complete as required .
RISING MAINS SYSTEM
Supplying, installing on wall, testing and commissioning of 630 amps, 35kA breaking capacity (100% Neutral busbar) As per IEC 61439-6 sandwitch type Cu Conductor Rising mains having Class-B Insulation with tap off connection point at every floor, expansion joints, fire barriers including necessary support and louvers for ventilation, including 2 Nos. of 40 x 6mm G.I. earthing strips through out the length of the rising mains system made of CRCA sheet steel enclosure of thickness not less than 1.5mm having degree of protection of IP 55 as per 2127, wall strapes, fully PVC insulated four strip aluminium bus bar in convenient sections including, end feed unit, end cover units suitable for 415 volts 3 phase, 4 wire, 50 Hz AC system etc.as required,
Supplying, installation, testing & commisioning of 630A capacity End Feed Unit for sandwitch type Cu Conductor Rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required
Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing sandwitch type Cu Conductor Rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required 125 A 25kA
Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing sandwitch type Cu Conductor Rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required 200 A, 25kA
FIRE DETECTION & ALARM SYSTEM
Supply, Installation, Testing & Commissioning of Microprocessor based 10 loop intellegent analogue Addressable Type UL/FM listed Fire Alarm Control Panel, with minimum 5.5inch/600 character LCD display ,The panel should be equiped of Sufficiant number of loops with loop capacity to take 125+125 intellegent addressable detectors/ devices in one loop. Four access levels, capable of taking Protocol Devices, Graphical Display, sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans, fire pump room, monitoring of fire sprinkler and fire hydrant pump, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. The panel and shall be interface with PA system (For Giving triger Signal to Start prerecored Digital/Analog Voice Excavation from PA system in case of fire ),Fire Hydrant System .It shall have interfacing connectivity (BACNET/ MODBUS/ Openprotocol gateway) for Building Management System complete as required. (UL 9th Edition Approved and NFPA)
Supply, Installation , Testing & Commissioning of the GUI based main network Fire Detection must be capable of graphically representing each facility being monitored with floor plans and icons depicting the actual locations of the various systems; and / or sensors’ locations. The GUI software shall be located in control room in one of the Floors and shall monitor all the Floor Fire Detection.The software shall be capable of monitoring 100 Nodes with minimum 128Kbps baud Transmission rate on Network.The software shall provide the facility to Monitor, Control all the 2 way communication from main control room using voice signals over Fire Network along with the Fire detection signal. The software shall be capable of broadcasting on Voice over IP. (UL 9th Edition Approved and NFPA compliant) Operator work station with PC having Intel Pentium I7 or better Processor including Serial ports (RS232) and USB ports and following accessories etc. complete with software all as specified. 2 Gigabytes of RAM memory 320 Gigabytes of hard disk space DVD ROM 19” TFT colour monitor Mouse with Mouse Pad Standard Key Board Latest Windows Operating System Compatible Fire Alarm System Control Software Laser Printer colour A4- 1 No Software for Automatic Fire Detection and Alarm System Software for Aspiration Based Smoke Detection System UPS 600 VA
Supply, installation, testing and commissioning of UL listed Repeater Panel character for Fire Alarm System with 5.5inch/600 character LCD alpha numeric display with complete system function keys for programming and control like System Reset, Alarm Acknowledge, Alarm Silence, Trouble Acknowledge etc as per specification. The Panel shall be connected/Interface to Main Fire Alarm Panel. (UL 9th Edition Approved and NFPA)
Supply, installation, testing and commissioning of UL listed Intelligent Addressable Multi CriteriaType Detector with mounting based LED with Electronic Addressing Feature to programme the detectors. Complete as required to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete as required.(UL 9th Edition Approved and NFPA)
Supply, installation, testing and commissioning of UL listed intelligent Electronic Addressable type Heat Detector (Fixed cum-rate of rise type) with fixed temperature range upto 57o C complete with all fixing accessories like base, base box, self adhesive sticker indicating loop number and address etc. to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete as required..(UL 9th Edition Approved and NFPA)
Supply, installation, testing and commissioning of UL listed Addressable type Manual Call Point (break glass type) complete with Input Module, push button, enclosed in box with provision for cable or conduit coupling, self adhesive sticker indicating loop number and address.The unit to be painted fire red outside, white inside and written 'In case of fire break glass.'(UL 9th Edition Approved and NFPA)
Supplying, installation, testing & commissioning of Response Indicator (METAL CLADE)which consists of steady glowing LED. This LED shall be mounted within a M.S. box and connected in parallel to the built in indicator of the detector as per specifications. The RI shall come "ON" as soon as the detector activates complete in all respects as per specification.
Supply, installation, testing and commissioning of UL listed Hooter cum Strobe with control module interconnecting to loop cable complete as required. The strobes shall be synchronized for better evacuation as per specification complete as required.
Supply, installation, testing and commissioning of UL listed addressable Single Input Signal Module for various output to control and integrate the sounder cum strobe with the fire alarm panel including connection complete as required.
Supply, installation, testing & commissioning of UL listed Fault Isolator Module as per specifications.(UL 9th edition Approved and NFPA) complete as required.
Providing, installation, testing & commissioning of UL listed Control relay Module (for control of AHU, ventilation fan etc) as per specifications.(UL 9th edition Approved and NFPA) complete as required.
Supply, installation, testing & commissioning of UL listed monitor module with (for monitoring different electrical/mechanical device like flow switch etc.) as per specifications.(UL 9th edition Approved and NFPA) complete as required.
Supply, Installation, Testing and Commissioning of 2 way communication Fire Fighter's Telephone Jack fitted on wall including the cost of breaking and making good the wall wherever required, complete in all respects as per specifications. (UL 9th edition Approved and NFPA) complete as required.
Supply, Installation, Testing and Commissioning of 2 way communication Fire Fighter's Handset complete with all accessories as per specifications.
Supply, installation, testing and commissioning of UL listed/FM approved Addressable control modules for fireman telephone jack etc.
Supply, Installation, Testing and Commissioning of HPSR 2Cx1.5 sq.mm MICA taped Fire Survival Cable insulated overall shielded BASEC & LPCB certified cable conforming to BS:7846 & BS:6387 CWZ, BSEN 50200. The cable shall withstand 950 degree centigrade for 3 hours conforming to BS:6387 standard complete with mounting accessories required for mounting & tagging. (Fire Alarm and Detection System)
Supply, Installation, Testing and Commissioning of HPSR 4Cx1.5 sq.mm MICA taped Fire Survival Cable insulated overall shielded BASEC & LPCB certified cable conforming to BS:7846 & BS:6387 CWZ, BSEN 50200. The cable shall withstand 950 degree centigrade for 3 hours conforming to BS:6387 standard complete with mounting accessories required for mounting & tagging (For Fire-telephone Jack)
Supply and laying of 25 mm dia. Flexible MS Spiral Steel Conduits with GI clamps, fittings/couplers and saddles for drawing detector control cables from surface to below false ceiling etc.
FIRE FIGHTING SYSTEM FIRE FIGHITNG AND HYDRANT SYSTEM
Supply, installation, testing and commissioning of Electric driven main fire pump suitable for automatic/manual operation and consisting of following: complete in all respect as required as per specifications. (i) Horizontal type, multistage, centrifugal, split casing end suction pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm.at highest and farthest outlet at specified flow of 2280 lpm at minimum 80 M head conforming to IS 1520. (ii) Suitable HP squirrel cage induction motor, TEFC, synchronous speed 1450 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS- 325. (iii) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. duly painted as required. (iv) Suitable cement concrete foundation duly plastered with anti vibration pads.As recommended by OEM or EIC.
Supply, installation, testing and commissioning of Diesel Engine driven main fire pump suitable for automatic/manual operation and consisting of following: complete in all respect as required as per specifications. (i) Horizontal type, multistage, centrifugal / end suction pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm.at highest and farthest outlet at specified flow of 2280 lpm at minimum 80 m. head conforming to IS 1520. (ii) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 Volts electric starting equipment, Diesel Tank as per OEM standard with suitatble M.S. stand , exhaust pipe extended up to 6 m. outside pump house duly insulated with 75 mm. thick glass wool (density 48kg/cum) with 24 SWG aluminium sheet clading, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with posts office red colour including battery, battery stand, AVM pads, etc. as required. (iii) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. duly painted as required (iv) Suitable cement concrete foundation duly plastered with anti vibration pads. As recommended by OEM or EIC (v) Stage Panel for Start/Stop Indicators. Note: The contractor has to provide 01 no. 990 ltr day oil tank in addition to Diesel Tank as per OEM standard. Supply, installation, testing & commissioning of Calibrated HSD buffer/service tank, rectangular MS (IS:226) construction with 990 liters capacity complete with flanged inlet & outlet, overflow, drain, vent, mechanical level indicator, 450mm dia Access hole on top with cover, flame arrestor. Tank will be made out of 3mm MS sheet and will be provided with structural support to keep tank base at (2000mm) above FFL with access ladder arrangement, painting etc. complete as required. Note: The contractor has to provide 01 no. 990 ltr day oil tank in addition to Diesel Tank as per OEM standard. Supply, installation, testing & commissioning of Calibrated HSD buffer/service tank, rectangular MS (IS:226) construction with 990 liters capacity complete with flanged inlet & outlet, overflow, drain, vent, mechanical level indicator, 450mm dia Access hole on top with cover, flame arrestor. Tank will be made out of 3mm MS sheet and will be provided with structural support to keep tank base at (2000mm) above FFL with access ladder arrangement, painting etc. complete as required.
Supply, Installation, testing and commissioning of electric driven pressurisation(Jockey) pump suitable for automatic/manual operation and consisting o following: complete in all respect as required as per specifications. (i) Horizontal type, multistage, centrifugal / end suction pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure minimum pressure of 3.5 kg/sq.cm at farthest hydrant and flow of 180 lpm at minimum 80 m head conforming to IS : 1520. (ii) Suitable HP Squirrel cage induction motor TEFC type suitable for operation of 415 volts, 3 phase 50 Hz. AC with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. (iii) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. duly painted as required. (iv) Suitable cement concrete foundation duly plastered with anti vibration pads.As recommended by OEM or EIC
Supplying, testing, installation & commissioning of pressure switches for Electric, diesel and Jockey Pumps of diaphragm type, adjustable range from 0-10 kg/sq cm and a regulation of 0.1 to 1.5 kg/sq.cm direct mounted snap anting type made from die cast aluminium with epoxy powder powder coated finish and other wetted parts including necessary wiring upto control panel & other materials as required as per specifications.
Providing & fixing dial type (100 mm) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI, short pieces, nipples, elbows, stainless steel 'U' tube & ball valve, etc as required as per specifications.
Providing & fixing Electronic type water level indicator with LED panel mounted as required complete with probes & all control wiring etc.
Providing, laying, testing and comissioning of 'C' Class heavy duty MS Pipe conforming to IS:1239 / 3589 fittings like tees, elbows, flanges, tapers, compressed asbestos gaskets, nuts and bolts, etc. in ground including excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphatt tape as per IS:10221, refilling the trench etc. of following sizes complete as required. 150 mm dia
Providing, laying, testing and comissioning of 'C' Class heavy duty MS Pipe conforming to IS:1239 / 3589 fittings like tees, elbows, flanges, tapers, compressed asbestos gaskets, nuts and bolts, etc., on surface and providing cement concrete blocks as supports and painting with two or more coats of synthetic enamel paint of required shade complete as required. 150 mm dia
Providing, laying, testing and comissioning of 'C' Class heavy duty MS Pipe conforming to IS:1239 / 3589 fittings like tees, elbows, flanges, tapers, compressed asbestos gaskets, nuts and bolts, etc. Fixing the pipe on wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required.
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
200 mm dia
Providing, installation, testing & commissioning of PN 16 CI Y-Type strainer fabricated out of 1.6 mm thick stainless steel sheet with 3 mm dia holes with stainless steel flange. 150 mm dia
Supply, fixing, testing and commissioning of butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation) PN 1.6 with bronze /gunmetal seat duly ISI marked complete with rubber gasket, flanges, nuts, bolts, washers conforming to IS 13095, of following sizes as required as per specifications.
65 mm dia
80 mm dia
100 mm dia
150 mm dia
200 mm dia
Providing, installation, testing and commissioning of CI dual plate non return valve PN 16 of following sizes confirming to complete with rubber gasket, GI bolt, nuts,washers etc. as required.
80 mm dia
150 mm dia
Supplying & fixing, testing & commissioning of double flanged Sluice valve PN 1.6 rating with non rising spindle, bronze/gun metal seat, ISI marked complete with Nut, bolts & washers, gaskets, confirming to IS:780 of following sizes as required. 200 mm dia
Providing and fixing bronze flanged gate valve with nut, bolts & washers, painting etc complete as required as per specifications.
25 mm dia
50 mm dia
Supplying & fixing gun metal single headed fire hydrant landing valve with instantaneous Gun metal coupling of 63mm dia with cast iron wheel ISI marked confirming to IS:5290 (Type-A) with blank gunmetal cap and chain as required.
Providing & fixing non-percolating rubber reinforced lined (RRL) fire hose pipe (as per IS : 636) of 63 mm dia and 15 meter length. The hose shall be rated for brust pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked gunmetal male & female coupling (IS:903) bound & rivetted to hose pipe with copper rivets & 1.5 mm copper wire as required as per specifications. (Location : Internal fire hydrant)
Providing & fixing controlled percolation fire hose pipe (as per IS:8423) of 63 mm dia and 15 meter length rated for brust pressure of 35.7 Kg/sqcm. The hose shall be tested for flame resistance test in accordance to IS:8423. Hose shall be complete with ISI marked GM male & female coupling (IS:903) bound & riveted to hose pipe with copper rivets & 1.5 mm copper wire as required as per specifications. (Location : External fire hydrant)
Providing and Fixing 63 mm dia instantaneous pattern branch short gunmetal pipe, 20 mm dia nozzle conforming to IS 903, suitable for instantaneous connection to hose pipe coupling complete as required as per specifications.
Providing and fixing first aid hose reel drum of MS construction, spray painted in post office Red, confirming to IS:884 with upto date amendments, complete with the following as required. 30 m length x 20 mm (nominal internal) dia water hose Thermoplastic Textile reinforced type-2 as per IS: 12585 20 mm (nominal internal) dia gun metal ball valve & nozzle Drum and brackets for fixing the equipments on wall. Connection from riser to hose reel 40 mm dia stop valve(gun metal) & M.S. pipe including sockets, nipples, elbows etc.
Supplying and fixing of hose cabinet of size 0.9 x 0.6 x 0.5 mtr made out of SS sheet 2mm thick with 6 mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve, 2 nos 15mtr. long hose pipe, 1 no. branch pipe, mounted on wall OR raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect, for external hydrant, as required.
Providing and fixing angle iron (40mmx40mmx5mm) door frame and S.S. sheet (2mm thick) cum glass shutter of size 2.1mtr x0.9mtr (N.S.) with 25mmx 25mm x3mm angle frame all around and stiffened in between i/c hinges, handle, locking arrangement, painting with approved synthetic enamel paint i/c sign writing on glass at internal hydrant including providing & fixing S.S. sheet 2mm thick on remaining portion above door to close opening i/c painting etc. as required.
Providing & fixing double flanged flexicon rubber expansion joint (suitable for system test pressure) of standard length as per specs including rubber gaskets, flanges, nuts, bolts and washers complete as required as per specifications.
100 mm dia
150 mm dia
Supplying and fixing 4 way fire brigade connection of cast iron body with 4 nos. Gun metal male instantaneous inlet couplings complete with cap and chain as required for 150mm dia MS pipe connection, conforming to IS 904 as required as per specifications.
Providing & fixing MS cabinet to enclose fire brigade connection and draw out connection fabricated from MS sheet 2mm thick with 2mm thick MS sheet frame with full front glass door and locking arrangement duly painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade and suitably mounted on a raised masonry platform as required as per specifications. (Approx 0.6m x 0.6m x 0.45m)
Providing & fixing gun-metal fire brigade suction hose coupling with cap and chain as required (draw-out connection) with nut for female coupling as per IS: 902-1974 complete with 100 mm dia GI suction pipe and 100 mm dia foot valve (to be connected to static tank). Provision of GI drop pipe and foot valve shall be made in all the fire water static storage tanks as required as per specifications.
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.
Providing & fixing CI medium duty manhole cover with frame of 560 mm internal dia for valve chamber. The weight of the cover not to be less than 58 Kg and frame not less than 58 Kg as per standard design as required as per specifications.
Providing & fixing Auto Air vent for fire hydent and sprinkler, suitable for pressure not less than 15 Kg/Sq.cm.15 mm dia 15 mm dia
Fabricating, Supplying, Installation, Testing and Commissioning Air Vessel of continuous welded construction with flanged discharge header in pump house fabricated out of 10 mm thick dished ends and 8 mm thick MS sheet, Air Release Valve, complete with drain arrangement with 25 mm dia gun metal wheel valve complete with all accessories and mounting arrangements etc. as required of the following sizes.2 Metre high and 450 mm dia suitable to operate Jockey Pump, Main Fire Pump & Diesel Engine Driven Fire Pump.
Supply, installation, testing and commissioning of Electric driven main fire pump suitable for automatic/manual operation and consisting of following: complete in all respect as required as per specifications. a.Horizontal type, multistage, centrifugal, split casing / end suction pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm.at highest and farthest outlet at specified flow of 2280 lpm at minimum 80 M head conforming to IS 1520. Suitable HP squirrel cage induction motor, TEFC, synchronous speed 1450 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS- 325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. duly painted as required. Suitable cement concrete foundation duly plastered with anti vibration pads.As per OEM or EIC .
Providing, fixing, testing and commissioning of Installation Control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc. of size 150mm dia as required.
Providing & fixing brass quartzoid sprinklers (UL, FM approved) of 15 mm dia size, suitable for sustaining the seat & water hammer effect. The type & temperature rating shall be as follows : Pendant & rosette adjustable type with quartzoid bulb operating temperature at 68 deg. C as per specification.
Providing & fixing 25mm dia stainless steel (SS) flexible sprinkler hose fitting as required as per specifications.
1200 mm long
1500 mm long
Providing and Fixing electrically operated water flow switches (Vane type) including tamper switch and accessories, complete with tap off socket arrangement as required, with 2 Nos. NO/ NC potential free contact as required as per specifications. 150 mm dia
Providing and fixing inspectors test assembly complete with test valve, sight glass sectional drain valve, union with corrosion resistant orifice all complete as per drawing and as per specifications. 50 mm dia
Supply, installation, testing and commissioning ISI marked (IS:940-with updated amendments) portable chemical fire extinguisher, water (gas pressure) type capacity 9 litres with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets as required as per specifications.
Supply, installation, testing and commissioning ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 and walll suspension braket as required as per specifications.
Supply, installation, testing and commissioning of 4kg ABC (Powder Type) Fire Extinguisher. Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:13849-1993 as required as per specifications.
Supply, installation, testing and commissioning of 50 litres(Trolly mounted) Mechanical Foam type Fire Extinguisher. Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and conforming to IS:910 as required as per specifications.
Supply, Installation, Testing & Commissioning of Modular construction electronic Annunciation panel not less than 1.6 mm thick MS Sheet and Powder coated after 7 tank process, dust, damp and vermin proof suitable for receiving message through flow switch having approx. 12 zones (10 working & 2 spare for future) consisting of all buzzer,flash indicators, LED type indicating lamps, audio and visual alarm in case of fault, fire, etc. complete in all respect. The Anunciation panel must have battery backup with trickle cum boost charger and provision for interface with the Main fire and BMS system as per requirement at site.
Supply, installation, testing and commissioning Clean Agent Modular (celling mounted ) type capacity 5 Kg CE certified fire extinguisher filled with 236 FAC clean Agent Gas. Complete in all respect.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as required.
300 mm width x 50mm depth x 1.6 mm thickness.
150 mm width x 50mm depth x 1.6 mm thickness.
Supply, Laying, Fixing, Testing and Commissioning of following sizes of XLPE insulated PVC sheathed armoured Copper / aluminium conductor cable of 1.1 KV grade on existing cable tray / surface as required.
4 core x 2.5 Sq mm copper conductor armoured control cable.
3 core x 16 Sq.mm. Aluminium Armoured
Supply, Laying, Fixing, Testing and Commissioning of following sizes of XLPE insulated PVC sheathed armoured Copper / aluminium conductor cable of 1.1 KV grade on existing cable tray / surface as required.
3 core x 25 Sq.mm. Aluminium Armoured
3 core x 50 Sq.mm. Aluminium Armoured
Supply and making end termination with brass compression gland and copper/ aluminium lugs for following size of XLPE insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade as required.
4 core x 2.5 Sq mm copper conductor armoured control cable.
3 core x 16 Sq.mm.(25 mm) Aluminium Armoured
3 core x 25 Sq.mm. (25 mm) Aluminium Armoured
3 core x 50 Sq.mm. (32 mm)Aluminium Armoured
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. ( 2nos. For body earthing all DG )
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for connections . as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing . as required.
Supply, installation, testing and commissioning of clean gas fire suppression sytem having 1x80 Itr completele CCOE approved high pressure seamless BIS 7285 approved Cylinders having 80 ltr capacity, UL/FM/VDS approved FK5-1-12 clean agent gas with UL/FM/VDS listed valve assembly and electric solinoid switch. The system also to be fitted with low pressure supervisory switch for monitoring cylinder pressure gauge with safety burst disc safety cap, elbow and other accessories, mounting bracket, container straps, NRV , Pressure operated control head which shall allow for pressure actuation of gas mounted, manually operated actuator to actuate the gas flooding process with the help of a lever, flexible rubber hose with wire bralded enforcment to route the gas from the storage cyinder to the discharge piping, to be connected to the discharge outlet of gas cylinder valve & to be terminated at the system piping or discharge manifold, Flexible actuation hose complete as required. Discharge nozzle, 180/360 degree. Designated to provide proper flow rate & distribution FK5-1-12 gas to flood the hazard area as per latest NFPA 2001 requrement. Piping ASTM grade A 106 schedule 40 with fittings & supports and Gas Release Panel compatible to Fire Alarm System . Note- Above System shall be Installed at following location in ATC Tower UPS ROOM -GROUND FLOOR ,FIRST FLOOR,SECOND FLOOR IT SERVER ROOM -GROUND FLOOR AND FIRST FLOOR
Clean Gas Fire Suppression Systems 2x150 Itr completele CCOE approved high pressure seamless BIS 7285 approved Cylinders having 150 ltr capacity, UL/FM/VDS approved FK5-1-12 clean agent gas with UL/FM/VDS listed valve assembly and electric solinoid switch. The system also to be fitted with low pressure supervisory switch for monitoring cylinder pressure gauge with safety burst disc safety cap, elbow and other accessories, mounting bracket, container straps, NRV , Pressure operated control head which shall allow for pressure actuation of gas mounted, manually operated actuator to actuate the gas flooding process with the help of a lever, flexible rubber hose with wire bralded enforcment to route the gas from the storage cyinder to the discharge piping, to be connected to the discharge outlet of gas cylinder valve & to be terminated at the system piping or discharge manifold, Flexible actuation hose complete as required. Discharge nozzle, 180/360 degree. Designated to provide proper flow rate & distribution FK5-1-12 gas to flood the hazard area as per latest NFPA 2001 requirement. Piping ASTM grade A 106 schedule 40 with fitting and supportnd Gas Release Panel compitable to fire alarm system.
Supply,installation,testing and commissioning of air cooled VRF outdoor units complete with Twin Rotary/Scroll Inverter type compressors, special pre coated fins,panel,corrosion resistant coated condenser ,invertor based condenser fan having interconnected control wiring housed in compact housing, refrigerant & Oil charging, MS hot dip galvanised suitable size stands for ODU,electrical & microprocessor panel,isolating valves and all required acessories for proper functioning of units,suitable to operate on 440 +10% volt,50Hz,3 phase- AC power supply of the the following capacities.Outdoor units supplied should be cooling only Type as well as should be modular in Nature).The Compressors used should be 100% Inverter twin rotary/scroll type. The VRF ODU offered should have at least 2 Nos. of inverter compressor in each module above 14 HP. The ODU offered shall offer high COP of 5.6 @ 50% Load & 3.6@ 100%.
10 HP Nominal Capacity
12 HP Nominal Capacity
14 HP Nominal Capacity
Supply, installation, testing and commissioning of factory fabricated customized Double Skinned VRV DX Air-handling unit Floor mounted / ceiling suspended type fabricated out of extruded aluminium section with 0.8 mm pre-plasticized / pre-coated ,Galvanised steel sheet outside & 0.8 mm plain Galvanised steel sheet inside with blower, blower section and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 6 Row cooling coil made of Aluminium finned Copper tube with coil section, pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90%, polished stainless steel drain pan made out of 22 G sheet duly insulated complete with motor, belt drive package, guard etc.,without face and bypass dampers. The AHU panels shall be insulated with50 mm thick injected PUF of density not less than 40 kg/cu/m. Fan motors shall be energy efficient and shall be 415±10% volts, 50 cycles, three phases, totally enclosed fan-cooled squirrel cage induction class F, with IP-55 protection. Motors shall be especially designed for quiet operation. Motor shall be suitable to operate with direct driven plug fans and frequency converter. Frequency converter (VFD) shall be supplied by the AHU manufacturer for all AHUs with direct driven plug fans for the complete control of motor. rpm. The motor shall conform to IS: 325. "Three phase induction motors" having class F insulation. The fan motor shall have the efficiency level of IE-3 whichever is more efficient. Motors shall be as per ECBC.Fan motor assembly shall be statically and dynamically balanced & certified as per relevant ISO/AMCA Standards The motor & blower assembly shall be mounted on Aluminium extruded section only. The complete AHU shall conform to specication & face velocity across cooling coil shall be limited to 152 MPM maxm. AHU DX coils shall be in tune with the requirement of VRV Outdoor Unit capacity and 1 / 2 / 3 / 4 equal divisions with respective HP ODU shall be made in cross sectional area of the coil respectively or as per manufacturer standard. The capacity of Air-handlers shall be as follows: Expansion Kit, Communication PCB , Thermostat & Corded Remote Controller Supply, installation, testing and commissioning of Electronic Type Expansion Kit, (Expansion kit should be of EEV type) + control kit suitable for VRF ODU Connection ,Communication PCB with Sensors, Corded Self Diagnostic Type Digital Thermostat, corded Remote Controller with LCD Display for controlling AHU kitY-joints etc. Note- The unit shall be certified by AHRI for Performance
21 TR 8400 CFM 35mm Static Press.for Ground Floor
28 TR 11830 CFM 35mm Static Press.for First Floor
29 TR 12435 CFM 35mm Static Press.for Second Floor
Ceiling suspended Units Supply, installation, testing & commissioning Inverter based 5 star rated split air-conditioning indoor unit consisting of condensing unit with variable speed fan motor, inverter type hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories such as piping, insulation copper tubing, gas charging, internal copper wiring/ Communication Cable, Voltage Stablizer/ Startor & remote control etc.
Split Air Conditioner Unit 3.3 TR 1150 CFM- Apron Level
Split Air Conditioner Unit 6.3 TR 2047 CFM Control Tower
CASSETTE TYPE UNITS 1.5 TR Ground Floor
CASSETTE TYPE UNITS 1.0 TR Ground Floor 02 Nos First Floor - 01 Nos Second Floor- 01 Nos 3rd Floor- 01 Nos Tower gallary- 01 Nos Apron Level. - 02 Nos
CASSETTE TYPE UNITS 2.0 TR Apron Level
HI WALL TYPE UNITS 2.0 TR Ground Floor/ First Floor/ Second Floor
Thermostat Sensor Supply, Installation, testing & commissioning of wall mounted fan display & Fan Speed regulation, temperature & RH settings on Thermostat Sensor with other necessary fitting and supports etc as required to complete the job, as per engineer in-charge directions , complete in all respect.
Precision Packaged type air conditioners Supply , installation, testing and commissioning of Bottom discharge (Below false floor) dual Coil (reffrigerant and chilled water) Precision Packaged type air conditioners of approved make as per the specifications complete with air cooled condenser on MS angle iron frame, and saddling arrangement for the traverse and support of refrigerant piping, interconnecting control cables, termination of and condensate drain piping duly insulated, chilled water coil and variable speed drive for condenser fan, scroll compressor, evaporator coil with hydrophillic coating, EC brushless motor, backward curved/ direct driven fan, with necessary multistage electric heater, and vibration isolator. Motor shall be suitable for 415 ± 10% volts, 50 ± 3% Hz, 3 phase AC supply and external static pressure shall be 25 Pa. Outdoor unit motor should be with IP-54/55 protection and should be weather proof. PAC shall have Down Flow with Fan section below raised floor. The cabinet Shall be provided with double skin side panels with inner panel of minimum thickness of 0.8mm and outer panel of thickness of 1.0mm Insulation in the side panels should be 19 mm thick glass wool and front & back panels should be insulated with 25 mm thick special acoustic mineral wool Refrigerant : R407C and complete with LCD screen display of actual and set point temperatures and relative humidity.It should be complete with microprocessor based logic controllerand sequential controller ,centrifugal blowers with latest innovative EC fan technology with “COMPOSITE “Blade material and other accessories, in all respect.Unit isolators (suitable for the motor and as per the specifications) shall be supplied alongwith the unit.The units shall be supplied with dedicated water sensors and BMS communicable port. 2.0 TR Ground Floor- 02 Nos First Floor- 02 Nos Second Floor- 02 Nos Third Floor - 01 Nos
COPPER REFRIGERANT PIPE (with insulation) Supply, Installation, testing & commissioning of Interconnecting hard/soft drawn copper refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber of class 'o' tubular insulation between each set of indoor & outdoor units as per specifications, and all piping inside the room shall be properly supported with MS hanger & clamps and all external piping with UV coating as per specifications, complete in all respect of various size as required
41.3 mm O.D. (insulation : 19 mm)
34.9 mm O.D. (insulation : 19 mm)
28.6 mm O.D. (insulation : 19 mm)
22.2 mm O.D. (insulation : 19 mm)
19.1 mm O.D. (insulation : 19 mm)
15.9 mm O.D. (insulation : 13 mm)
12.7 mm O.D. (insulation : 13 mm)
9.5 mm O.D. (insulation : 13 mm)
6.4 mm O.D. (insulation : 13 mm)
CONDENSATE DRAIN PIPING Supplying, laying, fixing, testing & commissioning of Rigid heavy class uPVC piping with minimum 9 mm nitrile rubber insulation over the pipes complete with fittings, supports, U trap complete with all necessary fittings such as elbows, tees, reducers etc and supports such as clamps etc. complete as per specifications, complete in all respect.
25 mm dia uPVC pipes
32 mm dia uPVC pipes
40 mm dia uPVC pipes
50 mm dia uPVC pipes
AIR DISTRIBUTION SYSTEM Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
Thickness 1.25 mm sheet
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Retrun Air Grills with aluminium volume control dampers as per specifications.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
Supplying, installing and testing of exhaust/ intake air GI outlet/intake louvers with bird screen complete as per specification & drawings.
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Fire damper
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
19 mm thick.
25 mm thick.
Supply, Installation, Testing & Commissioning of long casing (GSS) Vane/ Axial flow type fans complete with aluminium alloy blades with aerofoil design, bird screen, flexible connection & gravity louvers at outlet. Motor shall be of 415 + 10% volts, 50 Hz. Sound level at 3mt distance from fan outlet shall not be more than 73-80 db(A) (Room Condition). Capacity shall be as follows & as per detailed technical specification: Fans should be AMCA certified. Manufacturer shall submit “Certificate of conformity for 250 deg for 2 hours operation as per EN12101-3: 2002 issued by Internationally recognized Independent Fire Laboratory should be submitted along with type test report. The Type test report should clearly indicate the make of motor used during the testing and the same make/model of motor should be supplied by the fan manufacture at the site.” RPM Should Not exceed 1450. However lower cfm upto 5000 CFM can be provided at 2850 RPM. Outlet velocity should not exceed 13.5 m/s. NOTE:- Axial & Jet fans shall be AMCA certified for Air & Sound performance. In addition to this fire rated axial fans shall be UL or CE certified for 2 hours of operation at 250o C temperature.
Fire Extraction Fans 2500 CFM 30mm wg Static press. Smoke exhaust air For Apron level.
Fire Extraction Fans 6500 CFM 30mm wg Static press. Smoke exhaust air For Apron level.
Fire Extraction Fans 1250 CFM 30mm wg Static press. Smoke exhaust air For Apron level.
Pressrization 9000 cfm capacity with 35 mm static pressure for lift well pressurization
Pressrization 22500 cfm capacity with 35 mm static pressure for lift well pressurization
IN LINE FANS FOR TOILET EX.AIR 550 CFM
PROPELLER FANS FOR TOILET EX.AIR 100 CFM
Assosiated Electrical work for HVAC LT CABLES, TERMINATION & CABLE TRAY Supply of following size of 1.1kv grade multicore copper conductor XLPE insulated and PVC sheathed armoured COPPER cable as per IS : 7098:1988(Part - I) with upto date amendments.
4C X 6 Sqmm Cu cable
4C X 10 Sqmm Cu cable
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required.
4C X 6 Sqmm
4C X 10 Sqmm
Cable Laying: Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Control Cables Supplyof following size 1.1KV grade PVC insulated armoured multistrand copper conductor under . The cable shall conform to IS 1554/Part I
4core 2.5sq.mm
12core 2.5sq.mm
Supply and making end termination with brass Double compression gland and Copper thimbles for XLPE insulated and PVC sheathed copper conductor cable of 1.1kv grade of the following sizes as required.
4core 2.5sq.mm
12core 2.5sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE CONTROL cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
CABLE TRAYS:- Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. uspenders including bolts & nuts, painting suspenders etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 6 SWG GI wire
BUILDING MANAGEMENT SYSTEM Supplying, Installing, Testing & Commissioning of the Central Control Stations consisting of the following Server for BMS software
BMS Computer System: Supply, installation, testing and commissioning of i7 Processor or Equivalent Server PC, 4MB Cache with 8 GB RAM, & 1 TB HDD, 10/100 Mbps Ethernet card, USB connection & internal modem, Microsoft(R) Windows(R) 8 or better or latest OS Professional Enterprise, Web server software, DVD-ROM Drive (with RAM), 100/1000 Mbps NIC for Network connection and anti virus software . PC shall be with UPS for minimum 15 mints power backup
Colour Monitor LED Monitor - 21"
A-4 size Black and White laser Printer
Cordless Mouse & Key Board
SOFTWARE BUILDING MANAGEMENT SYSTEM WEB-BASED SERVER SOFTWARE BMS System Software : Supply, installation, testing and commissioning of simultaneous minimum 2 user Graphical Software meeting the requirements in the Given I/O Summary and technical specifications including configuration and facility to create / provide the graphic mapping for all I/O Summary points , animate the Graphics, Navigation between pages, display of logs, changing the time zones, popup alarms, configurable password protection for Building Mgmt System as per Specifications. Software shall be able to communicate with open protocols like BACNet devices simultaneously. Offered software shall have builtin feature for EMS, Alarming, reporting, scheduling & trending. The software shall have unlimited software & Hard ware capacity. During operation & maintenance if any controllers required to replace than software shall have feature to download logics in new controller as of old one, from control station, once the old controllers ip is maped in new one.
SYSTEM INTEGRATION UNITS FOR 3RD PARTY SYSTEM SOFTWARE INTEGRATION - UL listed Controllers Supply, installation, testing and commissioning of Bacnet IP (BTL certified) / Lonmark IP852 certifies (open Protocols) Integration units, to connect individual 3rd party microprocessor system controllers like Chillers & fans etc. the unit shall be capable of integrating all mentioned devices on BACnet, Modbus & LON etc.as per distribution given below : VFD integration as aper IO Summary UPS Integration as per IO Summary Energy Meter Integration as per IO Summary Packaged AC Integration as per IO Summary STP Integration as per IO Summary WTP Integration as per IO Summary Water Meter Integration as per IO Summary Fire Alarm Integration as per IO Summary DG Integration as per IO Summary System integration unit shall be of same make as of BMS System
Supply, installation, testing and commissioning of network switches. Switches shall be including Passive components inbuilt SFP ports / SFP modules, rack mountable, SMPS power supply & other termination accessories (Like Pigtails/LIUs/ Convertors/Splicing equipment ,Patch panel, Patch Cord, Etc.) complete as per specifications and as required for BMS DDC Panel Networking. Vendor to decide the quantity and size of network switches based on their network design.
PROGRAMMABLE & APPLICATION SPECIFIC CONTROLLER (DDC) Supply, installation, testing and commissioning of Bacnet IP/Lonmark IP (open Protocols) Direct Digital Controllers, The networkable controllers shall be , UL and BTL/ Lonmark IP852 certified, (vendor shall submit BTL/Lonmark IP852 certificate along with bid) with 32 bit microprocessor, real time clock & programmable memory. The Controller shall have built-in two Ethernet ports. Each DDC and IO module shall have built in LCD display & dial/button for local control & monitoring. The networkable DDC's shall be capable of peer to peer communication with lockable MS mounting cabinets duly powder coated connector strip, internal wiring and space to house controller & relays, connector etc. as per IO Summary. The Controller shall have built in memory to save graphics & logis for the connected points. The controller shall have minimum 10% spare IO capacity. Any Multiplexer (Mux) / AI to DI / DI to AI converters shall not be allowed. Max one DDC for 2 AHU shall be used.
Supply, installation, testing & commissioning of the following Sensors :
Supply, installation, testing & commissioning of Differential Switch across the blower and filters for indicating blower status. Pressure differential - 10mmWG.the swwitch shall be connecting tube and metal bends for connection to the duct. The housing shall be IP 54 rated. The contact shall be SPDT type with 230 VAC, 1 A Rating.
Duct mounted Tempreture Sensor for air as per technical specification.
Flame Proof Level Switch as per technical specification.
Water Diffrential Pressure switch as per technical specification.
Water Bi-level Switch
Duct CO2 Sensor 2000 ppm as per technical specification.
Supply, Installation, Testing & Commissioning of cables as below: Supplying, laying, termination, testing and commissioning of signal shielded cables . (2 core 1 mm2), PVC insulated, tinned copper conductor Armoured cable.
Supply, Installation, Testing & Commissioning of cables as below: Supplying, laying, termination, testing and commissioning of signal un shielded cables . (2 core 1 mm2), PVC insulated, tinned copper conductor Armoured cable.
Supply, Installation, Testing & Commissioning of cables as below: Supplying, laying, termination, testing and commissioning of communication cables. (2 core 1.5 mm2), PVC insulated, shielded, Twisted Pair, tinned copper conductor Armoured cable.
Supply, Installation, Testing & Commissioning of cables as below: Supply, Installation, Testing & Commissioning of Armoured Cat 6 cables
Supply, Installation, Testing & Commissioning of cables as below: Supplying, laying, termination, testing and commissioning of power un-shielded cables. (3 core 1.5 mm2), PVC insulated, tinned copper conductor cable Armoured cable.
SEWERAGE TREATMENT PLANT BASED ON MBBR MBBR EQUIPMENT Supply, installation, testing & commissioning of 2 Nos Stainless Steel (SS-304) Perforated/ Course & Fine Bar Screen with suitable lifting arrangement (size 600 mm wide x 600 mm high approx.). Item to include suitable garbage lifting Box/ Tray arrangement. The hole size of screen shall be for solid handling capacity of 12 mm.
Supply, installation, testing & commissioning of non clogging type pumps capable of handling solids (as stated for respective pump type), having C.I casing & C.I impeller complete with all accessories, motor of required capacity, Pressure gauge on delivery line with isolation cock, integration with level controller (with wiring) to control the level of sump automatically. Cost Shall also be inclusive of Isolation Butterfly Valve and NRV as stated under respective pump item. Pumps shall have following duty: Cost shall be inclusive of PVC flexible Hose pipe ( for piping submerged in effluent) with M S epoxy piping (for piping non-submerged in effluent. Provision of guide ropes to guide submersible pump from upper level to operational level in sump basin with channels / angle section of MSEP shall be made by the STP contractor.
Main Sewage Lifting Pumps (32 mm Solids)(1W + 1S) Flow rate : 1.25 cum/hr Head : 10 Mts Type : Submersible
Plant room sump Pumps (32 mm Solids)(1W + 1S) Flow rate : 4 cum/hr Head : 8 Mts Type : Submersible
Sludge transfer Pumps Capacity : 0.75 cum/hr Head : 8 M Type : Self Priming Screw Pump
Air Diffusion System: Supply, installation, testing & commissioning twin type rotary air blowers tank, capable of delivering 25 cum/hr of free air at 8 PSI driven through “V” belt or directly coupled through flexible coupling to a TEFC Motor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply.(1W + 1S).
Air piping shall comprise of pipes droppers/ laterals with M S (epoxy coated) Header complete with all fittings such as tees, crosses, plugs, sockets, elbows, reducers, supports & clamps, puddle flanges etc. cutting chases & making good. Contactor to submit detailed P & I indicating their proposal.
Non clog type air dispersion system capable of handling 3-5 cfm of air with oxygen transfer efficiency of 3-4% per/meter water depth. Air dispersion grid shall be assembled in modular form so that they can be replaced / repaired easily from platform at the top. (Imported fine bubble membrane diffusers).
Bronze Ball valve and air dispersion grid as required for STP as described above. Note:Air dispersion system shall be provided for equalization Sump/ tank, Aerobic digester cum Thickener & MBBR Tank.
Providing and fixing all piping (as described below) as required and isolation control valves for making the system complete. CPVC : Submerged air piping. All exposed inter connection piping. UPVC : Air header piping & pumped effluent riser (non-submerged air piping).
Supply, installation of MBBR Media for bioreactor tank and PVC tube deck media in secondary settling tank, MBBR MOC - PP, Specific Gravity - 0.93 to 0.95. (Make : Cooldeck/MM Aqua) with test certificate.MBBR Media 2 cum, Tube deck media 1.0 cum.
Supply, installation, testing & commissioning of poly electro type dosing system comprising of 100 ltrs HDPE/FRP tank with 0-6 lph electronic metering type pump
Supply, installation, testing and commissioning of Filter Press suitable for 225 kld daily average flow, plate size 12"x12"x12 nos manual plate manual complete in all respect.
Supply, installation, testing & commissioning of 100 ltrs HDPE/FRP tank with chemical for with 0-6 lph electronic metering type pump complete with motor for chlorine dosing complete as required.
TERTIARY TREATMENT SYSTEM AND EQUIPMENT Supply, Installation, Testing & Commissioning of Single Stage Horizontal centrifugal monoblock pumping set with CI body and CI- impeller, shaft of stainless steel SS 316 and SS shaft sleeve, mechanical seal, connected to a TEFC induction motor suitable for 400/440 volts, 3 phase 50 cycles A.C. supply with 1500 mm dia pressure gauge with gunmetal isolation cock, level controller, vibration eliminating pads as required, M.S fabricated base plate bolted to cement concrete foundations complete. Filter Feed Pumps :(1W + 1S) Capacity /Flow rate : 2.5 cum/hr Pumping Head : 30 M
Supplying, installing, testing and commissioning of FRP filter with media, CPVC frontal piping complete with multiport Valve (PN 10) Arrangement. Filter shall be suitable for working pressure of 2.5 - 3.0 kgf / sq cm and shall include standard fittings like Manhole Cover, Legs, pressure gauges, sampling cock, rinse drain. The corrosion allowance shall be 1.5mm to 2.0mm; the test press will be 5.5 (+/-0.5) kg/cm2. Activated Carbon Filter Flow Rate : 2.5 cum/hr Filtration velocity : 15000 ltrs/hr/sqm Filter Diameter : 500 mm
Filter Pressure Gauge, Niddle Valve and all other accessories for complete working of the Filter
Dual Media Filter Flow rate: 2.5 cum/hr Filtration Velocity: 15000 lts/hrs/ sqm Filter Diameter : 500 mm
Other Accessories on the Filter Pressure Gauge, Niddle Valve and all accessories for complete working of the Filter
Supply, installation, testing & commissioning of High Flow UV system for tertiary water treatment. The UV chamber shall be internally & externally electro polished with double side flange, drain part & probe bar. The unit shall use quartz glass technology for superior UV transmission and specialized high intensity UV lamp rated for 16000 hour operation. The UV dosage shall be greater than 60,000 μW-Sec / sq.cm Unit flow : 2.5 cum/hr
S.I.T.C of Electronic Flow Meter with Totalizer for clear water flow measurement. The meter shall be installed on-line and shall be suitable for feed water pressure up to 3 bar. The meter shall have its own display and should have interface to BMS.
Flow rate - up to 5 Cu-M/Hr.
On-Line pH Meter.
Fabricating and Installing following size of perforated Hot dip G.I cable tray including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders and including painting etc. as required.
300 mm width x 62.5mm depth x 2.0 mm thickness.
150 mm width x 50mm depth x 1.6 mm thickness.
Supply of following sizes of XLPE insulated PVC sheathed armoured Copper conductor control cable of 1.1 KV grade
4 core x 2.5 Sq mm copper conductor armoured control cable.
3 core x 10 Sq.mm. copper conductor armoured cable.
3 core x 6 Sq.mm. copper conductor armoured cable.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Supply and making end termination with brass compression gland and copper lugs for following size of XLPE insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade as required.
4 core x 2.5 Sq mm Cu
3 core x 10 Sq.mm. Cu
3 core x 6 Sq.mm. Cu
Providing and fixing following size of GI strips/ GI wire etc. on surface or in recess for connections, including GI clamps etc. as required. 25 mm x 5 mm GI strip
Providing and fixing following size of GI strips/ GI wire etc. on surface or in recess for connections, including GI clamps etc. as required. 6 SWG dia G.I. wire
WATER TREATMENT PLANT Supplying, installing, testing and commissioning single stage, submersible centrifugal pumps of closed coupled construction with CI body & cast iron (C.I) impeller connected to a fully submersible water/oil cooled motor suitable to operate with 380-415 volts 3 phase 50 cycles AC power supply with class F insulation and built -in temperature protection, pump connector unit with rubber diaphram & bend, vertical discharge pipe, guide pipe, stainless steel chain/rope, water -proof control panel, power cable and level controller complete in all respects for fixed installation. For Sump Pump (1 Working + 1 Standby) For Drainage Location - Plant Room Discharge 180LPM. Head 15 m HP/Load 2 (Approx)
WATER TREATMENT PLANT Providing and fixing horizontical/vertical monobloc centrifugal pumping set with mechanical seal cast iron (C.I) volute and bronze impeller connected to a IE3 induction motor suitable for 400/440 volts, 3 phase, 50 cycles A.C. supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating for each pump including necessary structual supports, clamps, bolts, nuts washers and 1:2:4 plain cement concreate (PCC) foundations
Filter Feed pump ( 1 Set = 1 working + 1 standby) Location - Plumbing Plant Room Capacity 50 lpm Head 35 m HP/Load 1 HP/Load
Irrigation Pumps ( 1 Set = 1 working + 1 standby) Location - STP Plant Room Capacity - 50 lpm Head - 30 m HP/Load - 1 HP/Load
STP makeup Pumps ( 1 Set = 1 working + 1 standby) Location - Plumbing Plant Room Capacity - 50 lpm Head - 30 m HP/Load - 1 HP/Load
Domestic Water Supply Pumps : ( 1 set = 1 W + 1 SB) Capacity for Each Pump : 175 LPM Head - 60 m
Flushing Supply Pumps : ( 1 set = 1 W + 1 SB) Capacity for Each Pump : 160 LPM Head - 60 m
MULTI GRADE FILTER: (For Domestic Water) Location - Plumbing Plant Room Supply, installation, testing & commissioning of vertical self supporting multi grade pressure filter (MGF) (Dual media filter) fabricated from MS sheet as per IS Code, pressure gauges at inlet & outlet, sample cock, air vent valve with piping, GI face piping distribution pipe with diffuser on top, CI butterfly valves and all accessories, with initial charge of filter media for filter, painting inside with food grade epoxy paint and outside with two coat of red oxide primer and two or more coat of synthetic enamel paint complete with bypass arrangement including piping and valves (3 Nos.) of required size. Capacity/Flow rate : 3 M3/hr Filtration rate/velocity : 18-20 M3/M2/hr Max. operating pressure : 3.5 kg/Sq.cm Test pressure : 5.5 kg/Sq.cm Suggested diameter : 500 mm
ACTIVATED CARBON FILTER: (For Domestic Water) Location - Plumbing Plant Room Supply, installation, testing & commissioning vertical self supporting Activated Carbon Filter (ACF) fabricated from M.S. Sheet as per IS Code, pressure gauge at inlet & outlet, sample cock, GI face piping, C.I. Butterfly valve and all accessories, air vent valve with piping, with initial charge of filter media for activated carbon filter, painting inside with epoxy paint and outside with two coat of synthetic enamel paint complete with bypass arrangement including piping, CI Valves (3 Nos.) of required size. Capacity/Flow rate : 3 M3/hr Filtration rate/velocity : 18-20 M3/M2/hr Max. operating pressure : 3.5 kg/Sq.cm Test pressure : 5.5 kg/Sq.cm Suggested diameter : 500 mm
Providing and fixing mild steel (MS) puddle flanges of required size with 5mm thick mild steel (MS) plate including necessary welding as per details shown on drawings and directions of Engineer-in-charge for water tanks.
25mm dia (4mm wall thickness)
32mm dia (4mm wall thickness)
40mm dia (4mm wall thickness)
50mm dia (4mm wall thickness)
65mm dia (4mm wall thickness)
80mm dia (4mm wall thickness)
100mm dia (4mm wall thickness)
150mm dia (4mm wall thickness)
200mm dia (4mm wall thickness)
Supply, installation, testing & commissioning of Hot dipped galvanised 'Y' Strainer fabricated out of 1.6 mm thick stainless steel sheet with 3 mm dia holes with stainless steel flange.
80 mm dia
100 mm dia
150 mm dia
Supplying, assembly, erection, testing and commissioning of magnetic level sensors and controllers, Chlorinated Polyvinyl Chloride (CPVC) probe tube, PP actuating float and all other equipment required for the performance of the system to the satisfaction of the engineer in charge complete including providing and fixing wiring from control junction box near the Under Ground tank to probes of required length, interconnection wiring between level controller and the concerned contactor in the starter panel as required. Level of all tanks (Under Ground and overhead tank) will be included in this item. The level controller will perform the following functions. To switch on the pumps when the level of water in the supply water tank is low and to cut off the pump when the level in the recieving water tank is high and switch off the pumps when the level of water in the supply water tank is low. To indicate 5 levels of water in all tanks through a control panle with LEDs To start the pumps in a cyclic order. The system shall be complete to ensure automatic operation of pump in accordance to water level in respective tanks.
Supply, fixing, testing and commissioning of Site Tube (of 3.0 - 5 M) with isolation valve at top and bottom demarcation on tube for making the installation of level indication on the RCC water tank complete.
Providing, fixing, testing & commissioning of 100 mm dia Burden type, Stainless Steel dial type pressure gauge including brass isolation valve and pipe having caliberation of 0-16 Kg/cm2.
Tube Well Boring/drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS:2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer - in-charge, upto 90 metre depth below ground level. Rocky strata including Boulders 300mm dia
Boring/drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS:2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer - in-charge, beyound 90 metre & upto 150 metre depth below ground level. Rocky strata including Boulders 300mm dia
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 65 mm dia nominal bore
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs conforming to IS: 12818, including hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer- in -charge.
Development of tube well in accordance with IS:2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by ''V'' notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-Charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing MS clamps of required dia on the top of the casing / housing pipe of tube well as per IS : 2800 (Part-1) , including necessary bolts and nuts of required size complete. 150 mm dia
Providing and fixing bail plug / bottom plug of required dia at the bottom of the pipe assambley as per IS: 2800 (Part-1). 150 mm dia
Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C.power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect for fixed installation as per details given below : (For Borewell) Discharge 300 LPM. Head 50 m HP/Load 6.0 (Approx)
ELEVATORS Design, Fabrication, Supply, Installation, Testing & Commissioning of Following Electric Traction Type Fully automatic machine room less (MRL) Passenger Elevator microprocessor based with AC variable voltage & variable frequency drive unit suitable for operation on 415 V, 3 Phase, 50 Hz. AC supply,having speed of 1.5 m /sec., power operate central opening / two-panel side opening type car & landing doors, electro-magnetic brake system, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, emergency light, intercom fesiability from lift to AAI EPABX with suitable hook up arranement,infrared ray sensing door protection for full height, reverse phase relay on controller, fire man's switch at ground floor, digital car positions indicator in car & at all floors with UP/Down direction, light fixtures, ventilation fan, landing sill, main beam in shaft for machine, pit ladder etc. complete with all accessories, serving different floors in the lift shaft along with Automatic Resue Device (ARD), Braille bottons complete with dry maintenance free sealed batteries as required etc. as per specifications and as under: Lift Shaft Dimension : 1850(W) x 1950 (D) No. of Passenger : 10 Nos.(minimum) No. of Landings : Five (5) Nos. (GF to 04th Floors) Travel Speed : 1.5 MPS Approx. Travel Height : 14 meters
M P KHAITAN
SOM PROJECTS PVT LTD
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid