Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC | L1 | Accepted-AOC AOC Awarded | |
| 2 | L2₹34.3 L+₹59,282 (1.76%)Rejected-Finance | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹34.7 L+₹99,402.50 (2.95%)Rejected-Finance 22B HEMILTAN ROAD GEORGE TOWN PRAYAGRAJ UP 211001 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L3 | Rejected-Finance Other than lowest quoted tenderer | |
| 4 | L4₹36.2 L+₹2.5 L (7.41%)Rejected-Finance | L4 | Rejected-Finance Other than lowest quoted tenderer | |
| 5 | L5₹36.4 L+₹2.7 L (8.01%)Rejected-Finance MOHAMMADPUR CHAIL KAUSHAMBI UTTAR PRADESH 212208 | PRAYAGRAJ | UTTAR PRADESH | 212208 | L5 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
27 Jun 2022, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST ALLAHABAD
GE WEST ALLAHABAD NEW CANTT ALLAHABAD
REPAIR TO ROOF, CHAJJAS AND SUNKEN PORTION TO BLDG UNDER AGE BR-I AT NEW CANTT ALLAHABAD
2022_MES_527413_1
8554/E8
Open Tender
Civil Works
Item Rate
270 days
NEW CANTT ALLAHABAD
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE WEST ALLAHABAD
₹90,000
Yes
14 Jul 2022
30 May 2022
29 Jun 2022
30 May 2022
27 Jun 2022
13 Jun 2022
Amount
Demolition of brick work built in cement mortar of any description including all quions arches, pillars, etc and removing debris complete all as specified and directed.
Taking down cement plaster on brick or stone walls incl wall tiles etc. with raking out joints, hacking for key, scrubbing down with water, etc and removing debris complete all as specified and directed
Demolition of plain cement concrete in any position including tar felt & cement mortar bedding etc from roof or sunkenc etc complete all and removing debris as specified and directed.
Dismantling of brick tiles or terracing tiles, single layer on roofs complete all as specified and directed.
Dismantling of floor hearth or wall tling including cement mortar bedding (but not backing), removing servicesable tiles to store and rubbish off the premises and removing debris complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for and removing debris complete all as specified and directed
M & L for brickwork with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces complete all as specified and directed
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces with WPC complete all as specified and directed (Note : WPC to be mesured and paid separately under appropriate item)
M&L for rendering 10mm thick in CM 1:3 on ceiling surfaces of RCC or brick complete all as specified and directed.
Complete removal of mud phuska from roofs of any thickness and removing the waste material from site to a distance exc. 250m but not exc. 500m and deposited where directed including cleaning of surface complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-0 (12.5mm graded stone aggregate) as in roof padding,roof kerbs, benching on roof slab and other similar works laid as per slop required finished even and fair complete all as specified and directed.
M&L for 10mm thick plaster in CM 1:3, mixed with liquid water proofing compound over concrete surface of roof /chajja on cleaning of surface complete all as specified and directed. (Note : WPC to be mesured and paid separately under appropriate item)
M&L for cleaning the dust,dirt and any other foreign material from roof surface and applying a coat of bituminous primer @ 0.40 ltr / Sqm uniformily and primer shall be allowed to dry over night as conforming to IS 3384-1986 complete all as specified and directed.
M&L for Laying of minimum 3mm thick APP membrane of (reinforced with non-woven fabric polyester type wt not less than 150 gms/sqm) & minimum weighing 3kg/sqm shall be done using butane torch maintaining 100mm side overlap and 150mm end overlap,sealing all overlaps and bonded to the surface by fusing and bonding torchon method complete all as specified and directed. (Note: All water proofing work shall be done as per manufacturer instruction and under supervision of manufacturer technical representative.)
Supply only Liquid water proofing compound (ISI marked) complete all as specified and directed.
M&L for 40mm thick brick tiles laid over and including 20mm thick screed bed in CM 1:4 mixed with polymer based liquid water proofing additive @ 5 % by weight of cement or as per manufacturer's instruction and the joints of tiles shall be filled with CM 1:3 mixed with crude oil as per SSR-2009 (Part-I) on roof area complete all as specified and directed.After laying the brick tiles the work shall be cured with water by ponding.
All as per item No 17 but using servicable tiles obtained from dismantling
M&L for cement concrete tiles 20 mm thick ( factory made machine pressed) (As per IS-1237: 1980) laid over and including 20 mm thick screed bed in CM 1:4 mixed with polymer based liquid water proofing additive @ 5% by weight of cement or as per manufacturer's instruction and the joints of tiles shall be filled with polymer based cement proof joint filler (manufactured by approved company) on roof area complete all as specified and directed. After laying the PCC tiles the work shall be cured with water by ponding.
M&L for Sunken floor treatment as in following sequence:- (a) The surface of Sunken floor is to be properly cleaning the dust,durt and any other foreign material,fungus moss etc from the surface. (b) M&L for 10mm thick plaster in CM 1:3, mixed with liquid water proofing compound over concrete surface of sunken area when concrete is green. (c) Applying a coat of bituminous primer @ 0.40 ltr / Sqm uniformily and primer shall be allowed to dry over night as conforming to IS 3384-1986. (c) M&L for APP based polymeric water proofing membrane of 3mm thick (reinforced with non-woven fabric polyester type) (weight not less than 3 kg per sqm) shall be done using butane torch maintaining 100mm side overlap and 150mm end overlap,sealing all overlaps including at all junction and corners with bonded to the surface by fusing and bonding torchon method complete all as specified and directed.
M&L for cement concrete 1:5:10,type E2 (40 mm graded aggregate) as in sunken filling and mass concrete works complete all as specified and directed.
M&L for 25 mm thick plain cement concrete type B0 1:2:4 (12.5mm graded aggregate) as in levelling course of floor and other similar works complete all as specified and directed.
M & L for first or premium quality non skid joint free coloured ceramic floor tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06sqm but n exc 0.11 sqm,in floor etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M & L for first or premium quality non skid joint free coloured ceramic floor tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm,in floor ,wall etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
S&F for first or premium quality glazed ceramic coloured tiles 300mm x 200mm size 6-7mm thick in dados or skirting over rendering 10mm thick in CM (1:4), jointed in neat grey cement slurry and pointed in white or colour cement to match the tiles complete all as specified.
M&L for first or premium quality glazed ceramic coloured wall tiles in vertical surface 450X300X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in 1:4 CM complete all as specified.
M&L for 32 mm bore galvanised steel tubes 'medium grade' as in sunken spout pipe complete all as specified and directed.
M&L for cutting holes in full brick walls, built in cement mortar for inserting of sunken pipe , holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
Disconnecting existing water tanks, Exc 250 & n exc 500 ltrs setting aside (or lowering if required) and hoisting, reconnecting and re-fixing in same position after cleaning complete all as specified and directed.
Disconnecting existing water tanks,Exc 500 & n exc 1000 ltrs setting aside (or lowering if required) and hoisting, reconnecting and re-fixing in same position after cleaning complete all as specified and directed.
S&F rotational moulded polyethylene water storage tank of capacity 500 ltr (Cylindrical/vertical with closed top) double layer construction, ISI marked hoisted & fixed in position including dismantling of old tank and removing from site complete all as specified and directed.
S&F rotational moulded polyethylene water storage tank of capacity 1000 ltr (Cylindrical/vertical with closed top) double layer construction, ISI marked hoisted & fixed in position including dismantling of old tank and removing from site complete all as specified and directed.
S&F in repair ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 20mm bore minimum weight 210 gms complete all as specified and directed.
S&F in repair ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 15 mm bore minimum weight 142 gms complete all as specified and directed.
S & F in repairs vitreous China white wash down water closet pan (pedestal pattern) including fixing bolts,plastic water closet white. seat cover clossed pattern with flat bottom (white colour) and cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including 'P' or 'S' trap complete all as specified and directed.
S&F in repair PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float & handle, waste pipe & brackets complete set all as specified and directed.
S & F in repair PVC connection 450 mm long, 15 mm size with brass chromium plated nuts complete all as specified.
Taking up or down 15 mm bore GI steel tubing and connections on (walls, ceiling, floors, etc.) including cleaning complete all as specified and as directed
Refixing old 15 mm bore GI steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed
S&F 15 mm bore GI steel tubing "medium grade" with all fittings and fixed to wall, floor and ceiling etc complete all as specified.
Taking up or down 20 mm bore GI steel tubing and connections on (walls, ceiling, floors, etc.) including cleaning complete all as specified and as directed
Refixing old 20 mm bore GI steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed
S&F 20 mm bore GI steel tubing "medium grade" with all fittings and fixed to wall, floor and ceiling etc complete all as specified.
S&F in repair for 15mm bore bib taps chromium plated with crutch or butterfly handle ,screwed down , screwed for iron pipes or brass ferrule complete all as specified and directed.
S&F in repair 15 mm bore chromium plated fancy type stop valves with long shanks fixed with 15 mm dia bore pipes complete all as specified and directed.
S&F in repair CP angle stop valve or cock of 15mm bore screwed down for high pressure with crutch or butter fly handle ,screwed both end for iron pipes complete all as specified and directed..
S&F in repair 15mm bore CP two way angle cock with wall flange fancy type with long shunk with cast copper alloy of crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F in repair 20mm bore dia stop valve cast copper alloy screwed down , high pressure with crutch or butter fly handle ,screwed both ends for pipe or for unions and fixed complete all as specified and directed.
S&F in repairs Stainless steel grating dome 100 mm dia with or without waste holes as required complete all as specified.
S & F in repairs 110 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trench complete all as specified and directed.
S & F in repairs 75 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trences complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed.
S & F in repairs PVC (SWR) floor trap plain or multi with stainless steel grating incl joinig to waste pipe with solvent cement joint dia of outlet 75 mm bore complete all as specified and directed.
Dismantling asbestos cement/galvalume sheet (corrugated, semi corrugated etc) sheets in roof coverings including ridges complete all as specified and directed.
S&F 6mm thick asbestos cement one-piece plain angular ridge fixed with L-type or J-type or cranked hook bolts complete all as specified and directed.
S&F 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls, etc fixed with L-type or J-type or cranked hook bolts complete all as specified and directed.
S&F 0.50 thick (including coated thickness) pre-colour, pre-profiled (Galvalume/Zinkalume) sheets of required colour and design having tensile strength of 550 Mpa as in roof, wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer/profile maker instruction complete all as specified and directed.
S&F 0.50 thick (including coated thickness) pre-colour, plain type sheet any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall,used as in ridge fixed with self tapping screws all as per manufacturer/profile maker instruction complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed.
M&L for steel work in tubular trusses, purlins, rafter,tubler column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
S&F in repair powder coated GI ceiling suspension system false ceiling grid of 600x 600mm size and 0.30 mm thick (MS galvanized with main tee, cross tee and wall angle grid hanging with 4mm dia Gl wire and roof fasteners or butterfly clips etc complete all as specified and directed.
S&F in repair 4 mm thick non asbestos fiber cement building board of 600x600 mm in size (HPSC E-classic) decorative finish fixed to aluminum /CGI frame work with hold down clips in false ceiling complete all as specified and as directed.
M&L in repair 15mm thick ceiling board (Angular tegular ) 600x600 mm in size, fixed on AL or GI snap grid complete all as specified and directed.
M&L for preparation of newly plaster surface of wall sand preparing and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty after it dries an complete all as specified and directed.
M&L for preparation of newly plaster surface of wall ,sand paeringand applying two coats of cement base paint including one coat of primer with Paint sprayers complete all as specified and directed.
M&L for preparation of newly plaster surface of ceiling and applying two coats of white wash complete all as specified and directed.
M&L for preparation of newly steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer with paint sprayers , complete all as specified and directed.
M&L for cutting holes not exc 100 sqcm into or through reinforced cemnt concrete slabs & chajjas etc including of reinforcememt as necessiated complete all as specified & directed.
M&L for RCC Design Mix M-25 as in ajjas,landing,balconies,canopies,desk slab & in shelves etc complete all as specified & as directed.
Use and waste of formwork to Chajjas,rack slabs,lintel or similar work for fair finished surfaces,horizontal or sloping etc complete all as specified & directed.
S & F Mild steel TMT bars 6 to 8 mm dia , cut to length, bent to shape required, including crancking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete as directed and specified.
M&L for 75 mm thick PCC M-10 Type C-2 as in plinth protection finished even and fair with PVC or glass strips not more than 3m or every turning complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in surface channel or surface drain including forming and finishing with extra cement including taking down existing concrete complete all as specified and directed.
Taking down chowkat with shutter (without taking off shutters from the frame) area not exc 1.5 Sqm each and removing from site complete all as specified and directed.
S&F Factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube with wooden grain printed PVC sheet used inserted of plain colour PVC sheet & edges will be painted to match with printed sheet complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified and directed.
S&F 100 mm long stainless steel butt hinges with steel pin complete all as specified and directed.
S&F 150mm long anodised aluminium handles, fabricated type complete all as specified and directed.
S&F for 200mm long anodised aluminium barrel tower bolt of extruded section complete all as specified and directed.
Taking down chowkhat with shutter (without taing off shutters from the frame) area exc. 1.50 sqm & n.exc 4.00 sqm each & removing from site complete all as specified & as directed
Anupravesh Enterprises
M/S VIVEK DUBEY
KAPIL AWASTHI THEKEDAR
HARSH ASSOCIETES
M/S Garg Sons
oasis contractor builder and supplier
SAP ENTERPRISES
Channa Brothers and Co.
GAYDIN CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .