Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | ₹1.2 Cr | L1 | Accepted-AOC Awarded being 1st Lowest Bidder |
| 2 | L2₹1.3 Cr+₹12.0 L (10.2%)Rejected-Finance | ₹1.3 Cr+₹12.0 L (10.2%) | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder |
| 3 | L3₹1.4 Cr+₹22.3 L (18.9%)Rejected-Finance RM 01 RIDHISIDHI I SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | ₹1.4 Cr+₹22.3 L (18.9%) | L3 | Rejected-Finance Rejected being 3rd Lowest Bidder |
| 4 | L4₹1.5 Cr+₹29.5 L (25.1%)Rejected-Finance | ₹1.5 Cr+₹29.5 L (25.1%) | L4 | Rejected-Finance Rejected being 4th Lowest Bidder |
| 5 | L5₹1.6 Cr+₹41.9 L (35.6%)Rejected-Finance | ₹1.6 Cr+₹41.9 L (35.6%) | L5 | Rejected-Finance Rejected being 5th Lowest Bidder |
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
6 Mar 2021, 6:00 pmClosed
HQ COMMANDER WORKS ENGINEER SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO. CWE SGNR-86 OF 2020-21 CONSTRUCTION OF ESHs / IGLOOS AT MILITARY STATION LALGARH JATTAN
2021_MES_415723_1
CA NO. CWE SGNR - 86 OF 2020-21
Open Tender
Civil Works
Lump-sum
330 days
GE LALGARH JATTAN
Class B
Category a(i)
10 documents required · 10 mandatory
₹1,000
GE LALGARH JATTAN
₹1.9 L
Yes
13 Mar 2021
30 Jan 2021
9 Mar 2021
30 Jan 2021
6 Mar 2021
20 Feb 2021
Amount
SCH 'A' SECTION - I (BUILDING WORK) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 5 signifies this fact onlyLump sum price as worked out independently by the Contractor based on drawings & specification for “Building works” as listed in Schedule ‘A’ Section- I shall be entered under Column 6
Construction of ESHs / IGLOOS building including both side platforms, water tank, hard standing, dawarf wall, ramp etc. as shown on drawings complete all as specified and directed by Engineer-in-Charge.
Construction of Static Water Tank of capacity 225 Kilo Litre, as shown on drawings complete all as specified and directed by Engineer-in-Charge.
Construction of Fire Point as shown on drawings complete all as specified and directed by Engineer-in-Charge.
Construction of Fire Board as shown on drawings complete all as specified and directed by Engineer-in-Charge.
Material & Labour of Dunnage Block of size 380mm x 300mm x 150mm as shown on drawings complete all as specified and directed by Engineer-in-Charge.
Subtotal
Schedule 'A' Section - II (Road Works)
Lump sum price worked out by the Contractor for **Rs. ______________ “Road Works" as listed in Schedule ‘A’ Section - II, Representing ** _______ % ____________ percent *Above / Below the lump sum price of Rs. 882416.00 inserted by the MES in Schedule ‘A’ Section - II (Part-I).
Schedule 'A' Sec - III (Part - I) (External Water Supply Works)
Lump sum price worked out by the Contractor for **Rs. ______________ “External Water Supply Works" as listed in Schedule ‘A’ Section - III (Part-I), Representing ** _______ % ____________ percent *Above / Below the lump sum price of Rs. 84885.20 inserted by the MES in Schedule ‘A’ Section - III (Part-I).
Schedule 'A' Section - III (Part-II) (External Water Supply Works)
Suply, fixing in trenches, testing and commissioning high density polyethylene pipes (HDPE) 90mm bore complete all as per IS-4984-1995 with all accessories i.e. socket, bend, Tees, elbows etc. of rating 8 Kg / Cm2 complete all as specified and directed by Engineer-in-Charge.
Supply, fixing in trenches, testing and commissioning high density polyethylene pipes (HDPE) 75mm bore complete all as per IS-4984-1995 with all accessories i.e. socket, bend, Tees, eblows etc. of rating 8 Kg / Cm2 complete all as specified and directed by Engineer-in-Charge.
Excavation, cutting existing pipe 200mm bore and inserting of HDPE 'T' of size 200mm x 200mm x 90mm for fixing of HDPE pipe of 90mm bore complete all as specified and directed by Engineer-in-Charge.
Excavation, cutting existing GI pipe 50mm bore and insert 25mm bore Tee complete all as specified and directed by Engineer-in-Charge.
Subtotal
Schedule 'A' Section - IV, (Part-I) (External Electrification Works)
Lump sum price worked out by the Contractor for **Rs. ______________ “External Electrification Works" as listed in Schedule ‘A’ Section -IV, (Part-I) Representing ** _______ % ____________ percent *Above / Below the lump sum price of Rs. 38777.32 inserted by the MES in Schedule ‘A’ Section -IV (Part-I)
Schedule 'A' Section - IV (Part-II) (External Electrification Works)
Supply and fixing MCB SPN, 'C' curve, 16 Amps, 10 KA 240 Volts 50 Hz in existing panel complete all as specified and directed by Engineer-in-Charge.
Subtotal
Schedule 'A' Section - V, (Part-I) (Lightening Protection Works)
Lump sum price worked out by the Contractor for **Rs. ______________ “Lightening Protection Works" as listed in Schedule ‘A’ Section -V (Part-I), Representing ** _______ % ____________ percent *Above / Below the lump sum price of Rs. 35335.40 inserted by the MES in Schedule ‘A’ Section -V (Part-I).
Schedule 'A' Section - V, (Part-II) (Lightening Protection Works)
M&L for earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25 mtr deep below the normal ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to gI earthing strip of size 32mm x 6mm flat by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate no. 3 of SSR Part-I connected to earthing test point or indicated including testing on complition complete all as specified an directed by Engineer-in-Charge Note : The unit rate shall be deemed to include for excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40mm x 40mm x 6mm, RCC 1:2:4, type B1 cover 40mm thick reinforced with 8mm dia CTD bars @ 75mm centre to centre both ways, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 40mm dia, earthing lead upto 7.5mtr complete all as specified in preambles of SSR Part-II and shown in electrical plate No. 3 of SSR Part-I
Subtotal
Schedule 'A' Sec - VI (Area Drainage Works)
Lump sum price worked out by the Contractor for **Rs. ______________ “Area Drainage Works" as listed in Schedule ‘A’ Section -VI, Representing ** _______ % ____________ percent *Above / Below the lump sum price of Rs. 105482.35 inserted by the MES in Schedule ‘A’ Section -VI
Schedule 'A' Sec - VII, (Environmental Pond Works)
Lump sum price worked out by the Contractor for **Rs. ______________ “Environmental Pond Works" as listed in Schedule ‘A’ Section -VII, Representing ** _______ % ____________ percent *Above / Below the lump sum price of Rs. 528439.40 inserted by the MES in Schedule ‘A’ Section -VII
Subtotal
Schedule 'A' Section - VIII (Internal Electrification Works)
M&L for flame proof surface point wiring for one light point with 1.50 Sqmm FRLS PVC insulated cable and PVC FRLS insulated cable 1.50 sq mm as earth wire in and including ERW steel rigid heavy duty conduit including flame proof junction boxes duly painted flame proof black enamelled of suitable size on wall complete with all fittings such as elbows, bends, connectors, sadles, clamps etc and other accessories complete all as specified and directed by Engineer-in-Charge. Note: Two nos of light point circuits shall be connected with one rotary switch in distribution control board.
M&L for flame proof junction box LM 6 protection 3 way including accessories suitable for 20 mm ERW pipe in wiring complete all as specified and directed by Engineer-in-Charge
M&L for flame proof junction box LM 6 protection 4 way including accessories suitable for 20 mm ERW pipe in wiring complete all as specified and directed by Engineer-in-Charge
Supply and fixing LED, flame proof type bulkhead light fitting, fixture 1x16W natural white colour CCT 5000 degree K, 1685 lumens, made of aluminium alloy LM6, with all accessories, driver, ballast, lamp holders, 2 KV surge protection etc complete including making recess in wall / roof and fixing with cement mortar 1:3 and making necessary connections complete all as specified and directed by Engineer-in-Charge
Supply and fixing LED, flame proof tube light fitting 1x20 Watt worm white colour made of aluminium alloy LM6, with all accessories, ballast, lamp holders, etc. internally prewired complete suitable for mounting on pendent including 02 Nos pendent rods of suitable size and flame proof specification having length of 1 mtr fixed to ceiling including fixing accessories at ceiling, nuts, bolts, washers etc duly painted with 2 coats flame proof white colour paint over a coat of anti corrisive primer and making necessary connections complete all as specified and directed by Engineer-in-Charge
Supply and fixing flame proof DB having 2 incoming and 12 outgoing with isolator of 63A - 01 No and outing SP of 6/10A - 12 Nos with operating knob conforming to IS/ICE 60079, protection class IP-65 , wall mounted with FLP glands for connections, temp class T6 complete all as specified and directed by Engineer-in-Charge
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed by Engineer-in-Charge Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 10 cms above ground level. (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slanting position.
Subtotal
Aggarwal brothers and company
KHANNA CONSTRUCTIONS
ROYAL BUILDERS
AJAY CONSTRUCTION COMPANY
M/S GODARA CONSTRUCTION CO.
M/s Balvinder Singh Engineer and Contractors
M/s DHEERAJ JAIN CONSTRUCTION COMPANY
M/s Luxmi Constructions
M/s Kamal Builders
M/s Azure Infrastructure Construction Co.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .