Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrRejected-Finance AT PO PS BEHERA SAHI CHOUDWAR DIST CUTTACK | CUTTACK | ODISHA | 752120 | ₹1.0 Cr | L1 | Rejected-Finance As per Govt Order |
| 2 | L2₹1.0 CrRejected-Finance AT PARIKUL PO BUANL PS SADAR BALASORE DIST BALASORE ODISHA 756027 | BALASORE | BALASORE | ODISHA | 756027 | ₹1.0 Cr | L2 | Rejected-Finance As Per Govt Order |
Tender Value
₹1.3 Cr
EMD Value
₹1.3 L
Closing Date
26 Feb 2026, 5:00 pmClosed
Executive Officer
Choudwar
Construction of Gosala at Choudwar Municipality
2026_ORULB_125188_1
CHM-07/2025-26
Open Tender
Civil Works - Others
Choudwar
Please refer Tender documents.
2 documents required · 2 mandatory
₹11,800
₹1.3 L
Yes
28 Apr 2026
2 Feb 2026
27 Feb 2026
2 Feb 2026
26 Feb 2026
2 Feb 2026
Earth work excavation in all kind of soil within initial lead of 50 m and initial lift of 1.5 m including rough dressing and leveling the bed...etc complete in all respect and as per the direction of Engineer-in-charge.
Supplying, & filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyance, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc., complete (Measurement will be taken on finished compacted section) as per specification and direction of Engineer-in-charge.
C.C (1:4:8) with 4cm size HG Crusher BROKEN metal including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C.
Providing, lifting, hoisting and laying Reinforced Cement Concrete of M-25 grade in Column base, Column Footings, Raft Foundation,Stem of the Columns, beams, chaujja, fin, lintel, stair case, jali , shelves and slab etc as per approved designs and drawings having a minimum compressive strength ( in work test) 20N. / Square mm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days including, centering and shuttering then after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials , cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position as directed by the Engineer-in-charge.(FOOTING)
Column
Plinth Bend
Lintel
Roof beam
Roof slab
Chhaja
Providing and fixing Centering and shuttering including strutting, propping etc. and removal of form the site after completion of respective work as the direction of engineer in charge.(Column footing)
Column
Plinth bend
Lintel
Roof beam
Roof slab
Chhaja
Cutting,Straightening coiled or bent up M.S plain HYSD/TMT reinforcement bars welding or jointing if necessary bending,binding,tying the grills as required for R.C.C works,providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance,loading, unloading & taxes of M.S plain/HYSD/TMT reinforcement bars and binding wires of 18 to 20 gaugo required for the work and cost of all labour, sundries, T&P and scaffolding complete in all respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.S plain/HYSD/TMT reinforcement bars consumed in the work only.
Brick work with Fly Ash bricks 25cm x 12cm x 8cm size having crusing strength not less then 75Kg/cm2 in cement mortar (1:6) in superstructure per cum.
Brick work with Fly Ash bricks 25cm x 12cm x 8cm size having crusing strength not less then 75Kg/cm2 in cement mortar (1:4) in superstructure per cum.
Providing 12mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to out side smooth surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge.
16mm thick cement plaster (1:6) on brick work including all cost conveyance royalty & taxes etc. comp. to work site per 1sqm
6mm thick cement plaster (1:4) onRCC concrete drain work including all cost conveyance royalty & taxes etc. comp. to work site per 1sqm
Wall painting 2 coats with weather coat over a coat of primer to inside and out side smooth surface with all cost of labour, T&P material etc complete.
Wall painting 2 coats with Plastic emulsion paint of approved shade over a coat of primer on new work to give an even shade with all cost of labour, T&P material etc complete.
M.S. Grill gate made out of M.S. flat conforming to IS 2062/20006 painted with red oxide primer as pe the design approved.
Painting two coats with approved synthetic enamel paints of Asian / Berger/Dulox make and of approved colour, shade to new Iron including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-charge. Note :- Sample of Paint & Primer shall be approved before procurement and use.
Dressed and Seasoned Sal wood work for door frames.
Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fitings and fixtures etc. complete. (SR-2022 New Miscellaneous Item-9 , Page-234).
Supplying, fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fittings and fixtures.(SR-2022 New Miscellaneous Item-12 , Page-235).
Supplying , fitting and fixing of openable PVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.
Fixing vitrified tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete.
Fixing vetrified tiles in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete.
Fixing of ceramic floor tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete.
Fixing Ceramic wall tiles in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete.
2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips complete all as per direction of Engineer-in-Charge.
Supplying and laying 2.5cm artificial stone flooring with cement concrete (1:2:4) including punning using 12 mm size crusher broken granites chips
Supplying, Manufacturing, fabricating & assembling of frame structure at stage area with circular/square hollow steel tube section of TATA STRUCTURE shall conform to CHS-IS-1161 & SHS/RHS of IS 4923 grade for shed component viz. column, truss, purlin etc as per approved drawing including two coat of primer & two coat of enamel painting.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Supply and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP- 63:2018. (SR-2022 New Miscellaneous Item-2 , Page-233).
Supplying, & filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyance, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc., complete (Measurement will be taken on finished compacted section) as per specification and direction of Engineer-in-charge.
C.C (1:4:8) with 4cm size HG Crusher BROKEN metal including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C.
Supplying and fixing of Pre cast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758: 1984.(SR-2022 New Miscellaneous Item-4 , Page-234)
Earth work excavation in all kind of soil within initial lead of 50 m and initial lift of 1.5 m including rough dressing and leveling the bed...etc complete in all respect and as per the direction of Engineer-in-charge.
Supplying, & filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyance, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc., complete (Measurement will be taken on finished compacted section) as per specification and direction of Engineer-in-charge.
C.C (1:4:8) with 4cm size HG Crusher BROKEN metal including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C.
Providing, lifting, hoisting and laying Reinforced Cement Concrete of M-25 grade in Column base, Column Footings, Raft Foundation,Stem of the Columns, beams, chaujja, fin, lintel, stair case, jali , shelves and slab etc as per approved designs and drawings having a minimum compressive strength ( in work test) 20N. / Square mm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days including, centering and shuttering then after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials , cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position as directed by the Engineer-in-charge.(FOOTING)
Providing and fixing Centering and shuttering including strutting, propping etc. and removal of form the site after completion of respective work as the direction of engineer in charge.(Footing)
Cutting,Straightening coiled or bent up M.S plain HYSD/TMT reinforcement bars welding or jointing if necessary bending,binding,tying the grills as required for R.C.C works,providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance,loading, unloading & taxes of M.S plain/HYSD/TMT reinforcement bars and binding wires of 18 to 20 gaugo required for the work and cost of all labour, sundries, T&P and scaffolding complete in all respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.S plain/HYSD/TMT reinforcement bars consumed in the work only.
M.S. Grill gate made out of M.S. flat conforming to IS 2062/20006 painted with red oxide primer as pe the design approved.
Painting two coats with approved synthetic enamel paints of Asian / Berger/Dulox make and of approved colour, shade to new Iron including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-charge. Note :- Sample of Paint & Primer shall be approved before procurement and use.
Labour for drilling a perfectly vertical bore holes of specified diameter for a specified depth below ground level through hard and boulder formation by means for Fast Drilling Sophisticated Rigs as required to suit the site condtion as per the direction of Engineer-in charge including deployment of rig with its accessories,T&P and consumables etc. for a finished bore suitable for lowering of 125 x 100 mm nominal dia PVC or GI casing pipes fitted with sockets and with or without well screens as per necessity for the soft and hard formations drilled by combination drilling method.
Labour for lowering the following sizes of PVC or GI pipes with or without strainers as per necessity and fitted and fixed up in perfectly vertical position including cutting and threading the pipes as may be necessary and supplying all jointing materials, extra sockets (GI or PVC heavy quality) , tools and plant etc. complete and keeping the top of the casing pipe threaded including plugging the tube wells to prevent entry of foreign materials from above.
Cleaning and developing the tube well with supply of comperssor worked till clear and adequate discharge is obtained from the tube well incuding supply and use of all necessary equipments and labour as per the direction of Engineer-in-charge.
Withdrawing casing pipes
Supplying all materials, labour and T&P for providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe up to 5 mtr below ground level to plug the bore hole including cost of cement etc. all complete as per direction of EIC.
Submersible/Centrifugal PumpSets without Control Panel
Star Delta Control Pannel with APFC arrangement
PVC ASTM Pipes and fittings (Riser & Down)Non-Concealed (40 mm dia CPVC pipe (Riser pipe)
25 mm dia CPVC pipe ( Down Pipe)
PVC ASTM Pipes and fittings (Riser & Down)Concealed (20 mm dia CPVC Pipe)
Supplying, Fittings & Fixing with all labour, T&P as per specification, the following Brass / CP(Jaquar) /G.M. fittings at appropriate locations along the pipe lines at all floors and at all heights of approved make confirming to relevent IS specification. etc.complete in all respect as per direction of the Engineer in charge.(a)15 mm dia C.P. 2 way Bib Cock (Short body) or Health Processor (3.2.14)
(a) 15 mm dia CP Bib cock ( Long Body)
(a) 15 mm dia CP Angle stop cock
(a)15 mm dia Conc. Stop cock.
(a)15 mm dia C.P. Pillar cock
(a) 15 mm dia C.P. Shower with arm
600 mm long CP Towel rail
(a)CP Soap holder
15 mm dia C.P. Towel Ring
600 mm long C.P. Glass shelf with C.P frame
(a)110 mm dia C.P. waste
40mm dia GM FW valve
Supplying, Fittings & Fixing with all labour, T&P as per specification, the following flexible PVC connection pipes and waste pipe making connection with pillar cock, cistern. Wash hand basin at all height and all floors with all jointing materials etc. complete as per direction of the Engineer -in- charge. (a) 450-600 mm long 15mm dia PVC connection pipe
(a)40 mm dia flexible PVC waste pipe 1 mtr each.
Supplying, Fittings & Fixing of 10 Ltr. Capacity low level P.V.C cistern white colour, to wall at all floors and at all height with all accessories etc. complete in all respect as per direction of the Engineer -in- charge.
Supplying, Fittings & Fixing of following sizes of porcelain wash hand basin confirming to relevant IS specification of Nycer/ Cera/ Parryware make to the brick / concrete wall etc. complete as per direction of the Engineer in charge.(a) Standard ( 550x400mm) size basin
Porcelain Squatting Urinal(600x355mm)
Supplying , fitting and fixing the standard size of European pattern porcelain wash down water closet confirming to relevant IS specification of Nycer/ Cera / Parryware make having 'S' or 'P' trap etc with all required materials, labour T&P etc. complete as per direction of the Engineer in charge.
Supplying ,fitting and fixing with all labour and T & P 4mm thick bevelled edge sheet glass mirror (508mmx406) of relevant IS specification to the brick concrete wall with full sheet hard board and CP down shaped screw on wooden /PVC plug etc. complete as per direction of the Engineer in charge.
Supplying all labour T & P etc for cutting holes in brick masonry wall/ RCC work for passing of GI /pvc Pipes of 15 mm to 50 mm dia and making good to the damages with C.M. (1:4) as per direction of the Engineer in charge.
Supplying, fitting & fixing of ISI marked PVC,CLASS-B(SWR) pipes with all materials, labour & T&P on concrete / Brick walls and grounds with nails, bobbins and wooden plugs as required including , scaffolding with proper plumbing fittings for exposed pipes complete in all respect as per direction of the Engineer in charge.(110mm dia PVC pipes (Ground Floor)
Supplying, fitting & fixing of following size of UPVC,CLASS-B(SWR) fittings of ISI marked to UPVC pipes (on concrete / Brick walls and grounds) with all materials labour T&P including cutting of the walls, with supply of nails, bobbins and wooden plugs as required including scaffolding etc. complete in all respect as per direction of the Engineer in charge.(110 mm dia Single Junction with door)
110 mm dia plain Door Bend
110 mm dia 'P' Trap
110 mm dia Off set
110 mm dia Cowl
75 mm dia Single Junction with door
75 mm dia elbow
Earth work excavation in all kind of soil within initial lead of 50 m and initial lift of 1.5 m including rough dressing and leveling the bed...etc complete in all respect and as per the direction of Engineer-in-charge.
Earthwork exxcavation Beyond 1.50m lift
Supplying, & filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyance, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc., complete (Measurement will be taken on finished compacted section) as per specification and direction of Engineer-in-charge.
C.C (1:4:8) with 4cm size HG Crusher BROKEN metal including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C.
C.C (1:2:4) with 4cm size HG Crusher BROKEN metal including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C.
Providing, lifting, hoisting and laying Reinforced Cement Concrete of M-25 grade in Column base, Column Footings, Raft Foundation,Stem of the Columns, beams, chaujja, fin, lintel, stair case, jali , shelves and slab etc as per approved designs and drawings having a minimum compressive strength ( in work test) 20N. / Square mm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days including, centering and shuttering then after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials , cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position as directed by the Engineer-in-charge (A) Tank bed
Providing and fixing Centering and shuttering including strutting, propping etc. and removal of form the site after completion of respective work as the direction of engineer in charge.(a) Footing
Cutting,Straightening coiled or bent up M.S plain HYSD/TMT reinforcement bars welding or jointing if necessary bending,binding,tying the grills as required for R.C.C works,providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance,loading, unloading & taxes of M.S plain/HYSD/TMT reinforcement bars and binding wires of 18 to 20 gaugo required for the work and cost of all labour, sundries, T&P and scaffolding complete in all respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.S plain/HYSD/TMT reinforcement bars consumed in the work only.
Brick work with Fly Ash bricks 25cm x 12cm x 8cm size having crusing strength not less then 75Kg/cm2 in cement mortar (1:4) in superstructure per cum.
Earthwork in excavation of foundation in all kinds of soil
B.W (1:4) in F & P
12 mm thick C.P (1:4)
M.S rod
Centering
Centering
Centering
Earth work excavation in all kind of soil within initial lead of 50 m and initial lift of 1.5 m including rough dressing and leveling the bed...etc complete in all respect and as per the direction of Engineer-in-charge.
Earthwork exxcavation Beyond 1.50m lift
Supplying, & filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyance, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc., complete (Measurement will be taken on finished compacted section) as per specification and direction of Engineer-in-charge.
C.C (1:4:8) with 4cm size HG Crusher BROKEN metal including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C.
C.C (1:2:4) with 4cm size HG Crusher BROKEN metal including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C.
Providing, lifting, hoisting and laying Reinforced Cement Concrete of M-25 grade in Column base, Column Footings, Raft Foundation,Stem of the Columns, beams, chaujja, fin, lintel, stair case, jali , shelves and slab etc as per approved designs and drawings having a minimum compressive strength ( in work test) 20N. / Square mm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days including, centering and shuttering then after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials , cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position as directed by the Engineer-in-charge.(Slab)
Providing and fixing Centering and shuttering including strutting, propping etc. and removal of form the site after completion of respective work as the direction of engineer in charge.
Cutting,Straightening coiled or bent up M.S plain HYSD/TMT reinforcement bars welding or jointing if necessary bending,binding,tying the grills as required for R.C.C works,providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance,loading, unloading & taxes of M.S plain/HYSD/TMT reinforcement bars and binding wires of 18 to 20 gaugo required for the work and cost of all labour, sundries, T&P and scaffolding complete in all respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.S plain/HYSD/TMT reinforcement bars consumed in the work only.
16mm thick cement plaster (1:6) on brick work including all cost conveyance royalty & taxes etc. comp. to work site per 1sqm
Brick work with Fly Ash bricks 25cm x 12cm x 8cm size having crusing strength not less then 75Kg/cm2 in cement mortar (1:4) in superstructure per cum.
Dry brick khoa well watered and rammed [Vide AR page-86/9]
Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq) (Make of modular box,cover,switch & socket-Legrand Arteor/schneider Zencelo/Panasonic Vision/Eq) With 10Years Warenty
Recessed wiring to secondary light point looped from primary light point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including 3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer-in-charge. (Make of wire KEI /Polycab/ Anchor / Havels/Eq) Average Length: 3 mtr
Recessed wiring to ceiling fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire KEI /Polycab/ Anchor / Havels/Eq) Group c
Recessed wiring to Twin control light point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type 2way switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer-in-charge. (Make of wire KEI /Polycab/ Anchor / Havels/Eq) Group C
Recessed wiring for 5 / 6 amp socket outlet with 6Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection on same switch board as per direction of Engineer-in-charge.
Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer-in-charge.(Make of wire KEI /Polycab/ Anchor / Havels/Eq) Group C
Recessed wiring for 2 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer-in-charge.
Recessed wiring for 6 pin 16 amp socket outlet with 16Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer-in-charge.
Recessed wiring for A.C/ Power socket outlet with industrial type socket outlet, plug top and metal chained cover in sheet steel enclosure ,20A/32A SP MCB including all accesories and connection as per direction of Engineer-in-charge.
Recessed wiring to exhaust fan/Wall Fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 6Amp 250V Modular Switch, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire KEI /Polycab/ Anchor / Havels/Eq) Group C
Call bell point
Recessed wiring to submain in 4 x 6 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire KEI /Polycab/ Anchor / Havels/Eq)
Recessed wiring to submain in 2 x 6 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire KEI /Polycab/ Anchor / Havels/Eq)
Recessed wiring to submain in 2 x 4 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire KEI /Polycab/ Anchor / Havels/Eq)
Recessed wiring to submain in 2 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire KEI /Polycab/ Anchor / Havels/Eq)
Recessed wiring to submain in 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire KEI /Polycab/ Anchor / Havels/Eq) (For Switch Board Looping)
Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required wih necessary MCB , RCCB / ISOLATORS as required.Note for MCB- There should be colour indication for tripping On ,Off & Trip/There should be mid trip position for toggles for electrical fault conditions.(With 5Years Warenty).(A)Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 4 way TPN Distribution Boards For BDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.Incommer 1 No-63A FP MCB (10KA) Outgoings-10/20A SP MCB 10KA-12Nos.(Make-L&T/ Hager/Schneider/Legrand/Eq)
Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 3.5core 35 sq.mm direct in ground including excavation , sand cushining protective covering and refilling the trench etc. as required.(Make-polycab/KEI/Rhino cable/Eq)
Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 4 core 16 sq.mm Aluminium on surface as required.(Make-polycab/KEI/Rhino cable/Eq)
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.(3.5C x 35 sq.mm)
4C x 16 sq.mm
Supply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used with Indication lamp, C.T , Digital Voltmeter, Digital Ammeter and control fuse etc. complete.MAKE- Legrand / Schneider/Hager/ L&T/SIEMENS/Eq.(A)MAIN PANEL with 100A 4P MCCB 25KA -1 No as incomer,63A 4P MCB 10KA 4Nos,80A 4P Change over Switch 1Nos, 40A 4P MCB 10KA.-3Nos, 32A DP MCB 10KA-3Nos with E.C Busbars with 4nos 65KA VSD along with 4nos 32A SP MCB.
Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required.
Supplying and laying 25 mm x 6 mm CU earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required.
Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess for connection etc as required.
Providing and fixing 8 SWG CU wire on surface or in recess for loop earthing as required.
Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required.Make-JAQUAR/Bajaj/Eq.With 5Years Warenty.(A)Ceiling mounted indoor type batten type LED Luminaire with LED Lamp Similar to JAQUAR Cat No. LGLZ01X024XW or equivalent.
Ceiling/ Wall mounted type BULK HEAD Luminaire with Similar to JAQUAR Cat No.LBLK02X010XW or equivalent.
Supply, Installation, testing and commissioning of 10W Mirror Light Similar to JAQUAR Cat no-LGLZ01X010XW/Equivalent.
Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required.Model -USHA ENERGIA 32 BLDC 5 STAR.
Supply, Installation, testing and commissioning of exhaust fan of 300 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required.Model-Usha AEROCLEAN.
Supply & fixing of 18W LED Down Light (S/R) similat to Jaquar Cat no-LNRO02S018SW/Equivalant With all accessories.
Supply & fixing of 90W LED Street light For Building Premises Light Similar to Jaquar Cat no-LSRT015090XC with all accessories.
Supply and installation of Pregalvanised Perforated type cable trays without cover. The rate shall include bends, Tees, all supporting brackets, anchor fasteners, screws, bolts, nuts etc., including painting of cable trays. Thickness of sheet steel shall be 2 mm. Support sizes similar to ladder type trays (Size of Cable Tray :150 mm x 50 mm)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.04 MB
BOQ_578239.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid