Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC 01 PATHWALIYA GONDA GONDA GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹40.0 L+₹3.3 L (9.13%)Rejected-Finance PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L2 | Rejected-Finance Second lowest amount quoted | |
| 3 | L3₹42.0 L+₹5.4 L (14.6%)Rejected-Finance MAIN ROAD RANJHI JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L3 | Rejected-Finance Third lowest amount quoted | |
| 4 | L4₹43.3 L+₹6.6 L (18.0%)Rejected-Finance MILITARY ENGINEER SERVICES GARRISON ENGINEER EAST JABALPUR 482 011 | L4 | Rejected-Finance Fourth lowest amount quoted | |
| 5 | L5₹43.4 L+₹6.7 L (18.3%)Rejected-Finance | L5 | Rejected-Finance Fifth lowest amount quoted |
Tender Value
₹44.6 L
EMD Value
₹89,500
Closing Date
9 Feb 2024, 6:00 pmClosed
Lt Col P Aditya Deepak, GE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
COMPREHENSIVE MAINT OF LT TRANSMISSION LINES, LT PANEL, MCCBS AND CONNECTED ITEMS IN CMM AND MAINT OF LT CABLES CONDUCTORS AND CONNECTED ACCESSORIES IN MAP ACCN IN ZONE C UNDER GE (EAST) JABALPUR
2024_MES_637591_1
8612/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Garrison Engineer (East) Jabalpur
Class D
category b (i)
7 documents required · 7 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹89,500
Yes
27 May 2024
19 Jan 2024
12 Feb 2024
19 Jan 2024
9 Feb 2024
2 Feb 2024
19 Jan 2024 - 25 Jan 2024
Amount
Taking down over head ACSR conductor/GI earth wire of any size and type after untyeing binding wire from insulators/cross arms and restringing to achieve permissible sag limit of over head line including new binding wire of proper size complete all as specified and directed.
M&L for Preparation surface of existing steel tubular poles 7.5 mtr long (above ground level) including cross arms, nuts, bolts, and applying one coat of approved quality of aluminum paint all as Specified and directed.
Diconnecting LT elect cable of any size and type from existing elect source and taking out carefully loop of cable not more than 2.5 m length from trench, cut the worn out portion of cable, provide new aluminium cable lugs wherever necessary of suitable size and reconnect the elect cable to the source, testing and commissioning complete all as directed.(Excavation & earth work for loop portion shall demmed include in quoted rate).
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 Volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of following cross sectional area :-
10 Sqmm x 2 core
16 Sqmm x 4 core
25 Sqmm x 3.5 core
35 Sqmm x 3.5 core
50 Sqmm x 3.5 core
70 Sqmm x 3.5 core
95 Sqmm x 3.5 core
120 Sqmm x 3.5 core
150 Sqmm x 3.5 core
185 Sqmm x 3.5 core
240 Sqmm x 3.5 core
300 Sqmm x 3.5 core
Dismantling and getting out old unserviceable cable from trenches, removing from pipe under road/fixed along pole etc any type and size complete all as specified and directed.
S&F in replacement on load change over switch, 63 Amps, 415 Volts, 50 Hz, open execution, mounted on common chasis complete with mechanical interlock and side operating handle assy complete all as specified and directed.
S&F in replacement on load change over switch, 100 Amps, 415 Volts, 50 Hz, open execution, mounted on common chasis complete with mechanical interlock and side operating handle assy complete all as specified and directed.
S&F in replacement on load change over switch, 200 Amps, 415 Volts, 50 Hz, open execution, mounted on common chasis complete with mechanical interlock and side operating handle assy complete all as specified and directed.
S&F in replacement MCCB 4 Pole, 415 Volt, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed.
S&F in replacement MCCB 4 Pole, 415 Volt, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed.
S&F in replacement MCCB 4 Pole, 415 Volt, Adjustable type, 400 Amps with breaking capacity 36 KA complete all as specified and directed.
S&F in replacement MCCB 4 Pole, 415 Volt, Adjustable type, 350 Amps with breaking capacity 36 KA complete all as specified and directed.
S&F in replacement MCCB 4 Pole, 415 Volt, Adjustable type, 500 Amps with breaking capacity 36 KA complete all as specified and directed.
S&F in replacement MCCB 4 Pole, 415 Volt, Adjustable type, 630 Amps with breaking capacity 50 KA complete all as specified and directed.
S&F teak wood rectangular board of size 20 x 15 x 5 cm clossed recessed complete all as specified and directed.
S&F teak wood rectangular board of size 25 x 15 x 5 cm clossed recessed complete all as specified and directed.
S&F teak wood rectangular block of size 30 x 20 x 5 cm clossed recessed complete all as specified and directed.
Excavating in trenches, in any type of soil n.exc 1.5m wide and n.exc 1.5m in depth for foundation, etc or n.exc 10 Sqm on plan and n.exc 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed.
Returning, filling in excavated soil, including spreading, leveling, watering and well ramming in layers n.exc 25cm each complete all as specified and directed.
Removing excavated soil n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for cement concrete 1:3:6, type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for sand cushioning with fine dry unwashed sand in trenches for protection of cables including gently punning complete all as specified and directed (Note - Punned thickness shall be measured and paid).
M&L for old size sub class ‘B’ bricks, laid in trenches as cable covers complete all as specified and directed.
Supply and stringing in repair ACSR conductor of any size for LT over head line including fixing to insulators with proper size of binding wire complete all as specified and directed.
S&F in replacement GI wire 4 mm dia/ stranded 7/2.24mm complete all as specified and directed.
S&F in repair mild steel galvanised stay assembly set complete comprising of 14 mm dia, 400 mm long stay bow, 1800 mm long stay rod 20 mm dia, 300 mm x 300 mm x 6 mm stay plate, thimble, GI stay wire of 7/8 SWG upto required length including loop type insulator of vitreous porcelain, small size with overall dimensions 90 x 140mm, clearance of hole 25.5 mm, all as shown in electrical plate No.1 of MES Schedule Part-I 2009 complete all as specified and directed.
S&F in repairs Shackle type, porcelain, vitreous, white, brown or green insulators 100mm height and 115 mm dia for working pressure 1100 Volts including galvanised mild steel strap 31 x5 mm size, washers, 14 mm dia insulator bolts, washers & nuts complete all as specified and directed.
S&F in repairs Pin type, porcelain, vitreous, white, brown or green insulator, 100mm height, 65 mm dia for 1100 Volts grade including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut complete all as specified and directed.
M&L in repairs for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of alminum paint over a coat of red oxide primer complete all as specified and directed.
M&L for boring of hole under road/hard standing by trenchless technology including S&F HDPE pipe "heavy duty " of size 100mm bore fixed in repairs complete all as specified and directed.
Cutting of hardstanding/Road for laying of pipe line/cable and making good surfaces after lying of pipe line/cable upto 30cm in depth as per existing specification complete all as specified and directed.
S&F in repairs Steel tubes, galvanised, light grade, ISI marked 80mm bore for protection of cable under floor, road and on wall complete all as specified and directed.
S&F in repairs Steel tubes, galvanised, light grade, ISI marked 50mm bore for protection of cable under floor, road and on wall complete all as specified and directed.
S&F in repairs Steel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall complete all as specified and directed.
M&L in repairs cradles hexagonal/rectangular, fabricated with galvanised steel wire 4mm dia complete all as specified and directed.
M&L in repairs loop type insulator, vitreous porcelain, white, brown or green large size with overall dimensions 140mm, clearance of hole 25.5mm complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead GI strip 32 x 6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule part-I 2009 complete all as directed. connected to earthing test point all as specified or indicated including testing on completion. Note : Earth lead beyond 7.5 meter shall be measured and paid saperately.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead GI wire 4mm dia as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel protected by 15 mm bore GI tube light grade all as shown in electrical plate No.3 of MES Schedule part-I 2009 complete all as directed. connected to earthing test point all as specified or indicated including testing on completion. Note : Earth lead including protection pipe beyond 7.5 meter shall be measured and paid saperately.
M&L in repairs Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20 x 15cm size for HT, 25 x 20cm size complete all as specified and directed.
M&L for Anti climbing device spike type fabricated out of MS bars (round square and flat) including nut bolts, washer and welding in two halve made to shape to suit the cross section of the pole complete all as specified and directed.
Trimming/pruning tree branches upto 1 spans of range to clear the OH conductors complete all as specified and directed at site.
Repair/maintenance of stay by tightening of stay wire after untying the conductor spans from the poles to make correct tension and maintain verticality of pole, including re jointing the conductors in position complete all as specified and directed.
Maintenance of indoor sub stations, including cleaning of premises and surroundings upto 5m from outer face of wall, checking of oil level of transformers, cleaning and dusting out of transformers, panel boards, cleaning of earth pits to keep free from vegetation etc complete all as specified and directed.
All as per item No 44 herein before but for out door sub stns including levelling of loose filled aggregate around sub station.
Maintenance of 11 KV sub station by cleaning of all vegetation and grass, cleaning of earth pits, watering to all earth pits, dusting out the transformers and equipments of indoor/out door types complete to keep the installation premises in a presentable manner complete all as specified and directed.
M&L for testing earthing of installations, buildings, equipments etc and treating of earthing by pouring salt water and submit result properly maintained sheets to Engr-in-Charge as directed. Note :- Contractor has to arrange advanced testing equipments and tools required for the job.
M&L for attending KWH meter complaints, repair like rectifying loose connections in meter and switch gears, checking and caliberation of meter to ensure proper function, testing, sealing and submission of reading after repair to Engr-in-Charge complete all as specified and directed.
Taking down partly unserviceable/unserviceable security/street/gate/flood light fittings from poles/towers/ Perimeter Fencing of any type upto 9 m height by manual or mechanical means and for necessary repair and make serviceable as per complaint given by department (E/M service cell) through job card/complaint register on day to day basis all to the satisfaction of Engr-in-Charge & complete all as specified and directed. Note :- Fittings/Ballast, Lamp holder, capacitor, ignitor, covers and lamps of required wattage/type shall be measured and paid separately.
Fixing only repaired serviceable street light fitting of any size, and any make complete all specified and directed by Engr-in-Charge
S&F LED street light fitting 35/45 Watt, 230 Volt AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F LED street light fitting 70 Watt, 230 Volt AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F LED street light fitting 90 Watt, 230 Volt AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F in repair GI pipe bracket 25mm dia GI pipe light grade, 1.5m long made to shape including 2 set of clamps made out of 30 x 5mm MS flat & fixed with anchor bolt suitable for security light fitting complete all as specified and directed.
S&F LED flood light 70 Watt, 230 Volt AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S&F LED flood light 120 Watt, 230 Volt AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and install Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410-SP-31 (9.0 m long) complete all as specified and directed.
S&F Cable jointing kit for 1100 Volt grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 35 sqmm complete all as specified and directed.
S&F Cable jointing kit for 1100 Volt grade grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm complete all as specified and directed.
S&F Cable jointing kit for 1100 Volt grade grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 150 sqmm complete all as specified and directed.
S&F in repairs PVC junction box IP-65 Protection of size 0.200 x 0.250 x 0.115 complete with 1 Nos of MCB SP 2.5 Amps & 4 way industrial connector including Clamp made out of MS flat 30 x 5 mm, connection from junction box to street light fitting with three single core PVC insulated & PVC sheathed wire 2.5 Sqmm copper complete all as specified and directed.
S&F TPN Bus Bar Chamber 400 Amp with Aluminium Bus bar having 4 Outgoing ways complete all as specified and directed.
Schedule of credit amount of Rs. 1,45,468.00 to be deducted during AOC.
shri krishna traders
RAVINDRA ELECTRICAL
deepak kumar vishwakarma
KRD ASSOCIATE
M/S BHARTI ENTERPRISES
ELCON
Shri kamal traders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .