| 1 | L1₹16.4 CrAccepted-AOC | ₹16.4 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹19.6 CrRejected-Finance 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA UDYAM DL 06 0048538 | NORTH WEST DELHI | DELHI | 110035 | ₹19.6 Cr | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹21.0 CrRejected-Finance | ₹21.0 Cr | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹22.2 CrRejected-Finance | ₹22.2 Cr | L4 | Rejected-Finance Other than lowest bidder |
| 5 | Rejected-Technical | - | - | Rejected-Technical Being not fulfil criteria as per NIT |
Tender Value
₹20.8 Cr
EMD Value
₹13.6 L
Closing Date
6 Jun 2025, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
WORK SERVICES FOR DOVELOPMENT OF OP SITE AND PROVISION OF PERIMETER WALL AT DIGHA AT AFS KALAIKUNDA
2025_MES_699972_1
88893/KKD/E8
Open Tender
Civil Works
665 days
Kalaikunda
As per tender documents
8 documents required · 8 mandatory
₹3,000
GE(P) AF Kalaikunda
₹13.6 L
Yes
24 Jul 2025
3 Mar 2025
9 Jun 2025
3 Mar 2025
6 Jun 2025
23 May 2025
Amount
SCHEDULE "A" Part - I (BUILDINGS/STRUCTURES WORK) Details of Buildings are given here-in-before:-
Design and construction of 01 block of Office Accn (OPs Bldg) in (G+1) configuration with RCC framed structure and permanent specification complete all as specified and as shown in drawing.
Design and construction of 01 block of Meat Storage Room in single storey configuration with RCC framed structure and permanent specification complete all as specified and as shown in drawing.
Design and construction of 01 block of FOL and POL store in single storey configuration with RCC framed structure and permanent specification complete all as specified and as shown in drawing.
Design and construction of 01 block MT garages (Parking for type B vehicle and parking for specialist vehicle) in single storey configurationwith RCC framed structure and permanent specification complete all as specified and as shown in drawing.
Design and construction of 01 block Refueling Trolly Parking Shed in single storey configuration with RCC framed structure and permanent specification complete all as specified and as shown in drawing.
Design and construction of 01 block Pay Load Store in single storey configuration with RCC framed structure and permanent specification complete all as specified and as shown in drawing.
Design and construction of 01 block Sub Station Building in single storey configuration with RCC framed structure and permanent specification complete all as specified and as shown in drawing.
Design and construction of 01 block Pump House Building in single storey configuration with RCC framed structure and permanent specification complete all as specified and as shown in drawing.
Design and construction of 01 block of Guard Rest Room with Watch Tower in (G+2) configuration with RCC framed structure and permanent specification complete all as specified and as shown in drawing.
Design and construction of RCC Static Water Tank of 50 KL capaicty with RCC framed structure and permanent specification complete all as specified and as shown in drawing.
Design and construction of RCC UG Sump of 10 KL capaicty with RCC framed structure and permanent specification complete all as specified and as shown in drawing.
SCHEDULE "A" PART -I (BUILDING WORK/ SUN SHELTER) Design, Construction and Erection of Pre-Engineered Buildings with Aluminium-zinc colour coated profiled steel roofing sheets 0.55mm thick (TCT) and yield strength of 550 MPa in roofing and cladding in gable portion camouflage pattern including RCC foundation, anchor bolts, base plates and all structural steel items, bird proofing net, rain water eaves gutters and down take pipes etc complete all as specified and as shown on approved drawings. Note :- (i) PEB structure to be designed to withstand 180 Km/hr (both in line and cross winds) and based on soil parameters. (ii) The rate quoted shall deemed to include the cost of designing, confirmatory soil investigation and vetting of design of PEB structures by IITs/ NITs. The design (showing full calculations and details) vetted by IITs/ NITs shall be submitted to the department as per time schedule. (iii) Suitable eves gutters and rainwater downtake pipes as required shall be provided to divert rain water from the roof to ground level . (iv) The rate quoted is deemed to include the cost for provision of necessary arrangement for fixing light fittings. (v) The rate quoted is deemed to be excluding the PQC flooring and the same shall be measured and paid separately.
Note for item No 2.00 to 12.00 :- (i) The rate quoted shall deemed to include the cost of confirmatory soil investigation, designing and vetting of design given in Srl Items No. 2.00 to 12.00 by any IITs/ NITs. The design (showing full calculations and details) vetted by IITs/ NITs shall be submitted to the department as per time schedule. (ii) Size of buildings shall be as per Architechtural drawings.
SCHEDULE "A" PART- II ( SITE CLEARENCE AND AREA DEVELOPMENT) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- III (RETAINING WALL) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- IV ( INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V ( INTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- VI (ROAD/PATH/CULVERT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- VII (PQC HARDSTANDING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- VIII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- IX (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- X (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XI (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- XII (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- XIII (FENCING, COMPOUND WALL AND GATE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XIV (MISCELLANEOUS ITEMS) Note:- Srl Item No. 2.00 to 13.00 and 28.00 to 98.00 and this schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
INTERNAL ELECTRIFICATION S&F flame proof switch socket & plug combined in LM6 cable termination box in LM6, 6A, 250V, 2P+earth complete all as specified and as directed.
S & F LED light fitting 40 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, completes all as specified and directed.
S & F LED light fitting 20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, completes all as specified and directed.
S&F flame proof exhaust fan 300mm sweep, single phase complete with bird guard louvers and three core copper conductor cable of suitable size for connecting with ceiling rose including making of hole in wall and making good to the disturbed surface complete with all accessories complete all as specified and directed.
S&F flame proof ceiling fan 1200mm sweep, single phase complete with accessories like holding down rod,hanging clamps, blades, fan hook including writing MES number (as per standard practice) including provision of three core copper conductor cable of suitable size for connecting with ceiling rose complete all as specified and directed.
S&F flame proof weather proof DB TPN 415 volt 6 way with bus bar and cast aluminium LM6 enclosure, operated externally spring type knob complete with M-25 cable entry to suit incoming cable and 02 Nos M-20 cable entries for outgoing cables from bottom with cable gland suitable for hazaradous area certified by CMRS dhanbad for group IIA & IIB consisting of Incoming : (a) MCB 4 Pole 100 Amps - 01 No Outgoing : (a) MCB SP 6-32Amps - 18 Nos complete all as specified and directed.
S&F flame proof weather proof DB TPN 415 volt 4 way with bus bar and cast aluminium LM6 enclosure, operated externally spring type knob complete with M-25 cable entry to suit incoming cable and 02 Nos M-20 cable entries for outgoing cables from bottom with cable gland suitable for hazaradous area certified by CMRS dhanbad for group IIA & IIB consisting of Incoming : (a) MCB 4 Pole 63Amps - 01 No Outgoing : (a) MCB SP 6-20Amps - 12 Nos complete all as specified and directed.
S&F flame proof weather proof DB SPN 230 volt 4 way with bus bar and cast aluminium LM6 enclosure, operated externally spring type knob complete with M-25 cable entry to suit incoming cable and 02 Nos M-20 cable entries for outgoing cables from bottom with cable gland suitable for hazaradous area certified by CMRS dhanbad for group IIA & IIB consisting of Incoming : (a) MCB SPN 32 Amps - 01 No Outgoing : (a) MCB SP 6-10Amps - 02 Nos complete all as specified and directed.
S&F flame proof weather proof DB SPN 230 volt 8 way with bus bar and cast aluminium LM6 enclosure, operated externally spring type knob complete with M-25 cable entry to suit incoming cable and 02 Nos M-20 cable entries for outgoing cables from bottom with cable gland suitable for hazaradous area certified by CMRS dhanbad for group IIA & IIB consisting of Incoming : (a) MCB SPN 40 Amps - 01 No Outgoing : (a) MCB SP 6-32Amps - 06 Nos complete all as specified and directed.
S&F flame proof weather proof DB SPN 230 volt 12 way with wash bar and cast aluminium LM6 enclosure, operated externally spring type knob complete with M-25 cable entry to suit incoming cable and 02 Nos M-20 cable entries for outgoing cables from bottom with cable gland suitable for hazaradous area certified by CMRS dhanbad for group IIA & IIB consisting of Incoming : (a) MCB SPN 63 Amps - 01 No Outgoing : (a) MCB SP 6-32Amps - 10 Nos complete all as specified and directed.
Supply and fixing Modular metal fluxh box with modular white cover plate with frame 8 module complete all as specified and directed.
S&F LED security light fitting not less than1x35 watt of minimum lumen efficiency of 110 lm/W with integral reflector made of aluminium alloy LM6 with LED driver, lamp, surge protector and all accessories pre wired including connection with three core PVC insulated, sheathed copper conductor cable of suitable size complete with GI bracket 1.5M long bend to shape of dia. 25/40 mm GI medium grade pipe with MS clamp including two coats of aluminium paint over a coat of red oxide primer and necessary fixing fasteners, complete all as specified and directed.
S&F MCCB, 4 Pole, 250 Amps, 50 Hz, 36 kA breaking cap with thermal magnetic release complete all as specified and directed
S&F MCB SPN 20 Amps (C-Curve), breaking capacity 10 kA, 240 volts, complete all as specified and directed.
INTERNAL WATER SUPPLY S&F of mixing valve (Concealed type Hot & Cold) cast copper alloy chromium plated with long shank and cup fancy type , screwed down, high pressure with crutch or butterfly handle including three joints to steel pipe or union and plugging and screw to wall of bore 15mm, complete all as specified and as directed.
S&F angle valve of 15mm bore, cast copper alloy with crutch or burret handle, chromium plated with long shank and cup, fancy type, screwed down, high pressure, screwed both ends for iron pipe or for brass ferrule complete all as specified and directed.
S&F 15mm bore, 125mm in size chromium plated shower roses with arm of minimum length 300mm, with or without swivel joints, including fixing to steel pipe or union, complete all as specified and as directed.
PQC HARDSTANDING M&L for polyurethane paint over hanger flooring, 3mm EPU system (100 micron primer) , 2mm epoxy screed, 1mm self levelling EPU top coat including cleanning the existing surfaces, all as per manufacturer instruction, complete all as specified and directed.
SEWAGE DISPOSAL Supply and fixing SFRC circular cover medium duly with frame of internal dia 560mm, heigth 120mm, and cover of outer dia 670mm, height 70mm, and total weight of manhole cover with frame shall be 100 kg complete all as spcified and directed.
M&L for soakage wells for 50 Users, excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as specified and as directed.
Reaming of bore well from 200mm dia. to 525mm dia hole in three steps from 200mm to 350mm, 350mm to 450mm and 450mm to 525mm up to 60M depth below ground level from the top of the ground complete all as specified and directed.
Reaming of bore well from 200mm dia. to 525mm dia hole in three steps from 200mm to 350mm, 350mm to 450mm and 450mm to 525mm from 60M to 130M depth below ground level from the top of the ground complete all as specified and directed.
Reaming of bore well from 200mm dia. to 525mm dia hole in three steps from 200mm to 350mm, 350mm to 450mm and 450mm to 525mm from 130M to 200M depth below ground level from the top of the ground complete all as specified and directed.
Reaming of bore well from 200mm dia. to 525mm dia hole in three steps from 200mm to 350mm, 350mm to 450mm and 450mm to 525mm from 200M to 260M depth below ground level from the top of the ground complete all as specified and directed.
Reaming of bore well from 200mm dia. to 525mm dia hole in three steps from 200mm to 350mm, 350mm to 450mm and 450mm to 525mm from 260M to 300M depth below ground level from the top of the ground complete all as specified and directed.
Supply, lowering and fixing in position150mm dia (internal bore) UPVC casing pipe of suitable wall thickness, complete all as specified and directed.
Supply, lowering and fixing in position of 200mm dia UPVC slotted pipe complete all as specified and directed.
Supply and filling pea gravel of size 3 to 6 mm for packing around the housing/assembly, slotted pipe of the bore well complete all as specified and as directed. Note:- Pea gravel shall be paid as per stack measurment carried out on site.
Yield testing of the tube well by suitable pump and motor for minimum discharge capaity of 20000 LPD(Liter per day) for at least continuous 16 hour uninterrupted of run per day for three continuous days complete all as specified and directed. Note : 'V' notch and other equipment including pump set shall be arranged by the contractor and cost of same is to be included in the unit rate quoted)
S&F of UPVC reducer, bail plug, well cap, electric logging and sample strata box of required sizes, complete all as specified and directed.
Supply, installation, testing and commissioning of submersible pumping set electric driven 415 volts TP suitable for 200mm dia bore well (casing pipe size 200mm) complete of 3 HP, 45m head, 50 LPM and inclussive of 40 mtr long submersible cable and starter complete all as specified and directed.
Supply, installation, testing and commissioning of openwell submersible pumping set electric driven 415 volts TP supply and Install complete of capacity 2 HP inclusive of , SWR and Cage and PCC foundation For pumping water from UG Sump complete all as specified and directed.
Supply and Installation commissioning and testing of Catalytic type of Iron remover plant 5000 gph complete, suitable for raw waler bring it to less than 0.3 mg/lt acceptable standard of potable water and testing chemical analysis of treated waler from approved Govt laboralory, complete with face piping valves, filler and catalylic media, under bed plate system filted with PVC Strainer, pressure gauge, manholes, air vent system, coagulant feeder, chlorine dosing unit, Air Compressor of suitable capacily for back wash complete all as specified and directed by Engr-in-charge. Technical specifications for Iron Removal Filter - 5,000 GPH / 22,000 LPH (i) PRE-FILTER :- VERTICAL, SINGLE DECK AND MULTIGRADE (a) Shell IS: 2062 MS fabricated factory made - 1,800 mm dia X 1,500 mm SOH ( CAPACITY: 5,000 GPH ) (b) Thickness of Body, Dish end & bed plate - 10 mm x 12 mm x 12 mm (c) Frontal (face) pipe line - 80 mm ERW pipe (medium grade) (d) Valves in frontal pipe line - Butterfly valves flangeless finish 80 mm - 05 Nos. (e) Under bed plate system with strainer- Double nut type PVC strainer- 250 Nos (f) Fitter media ( sand & gravels ) - 95 cft/2.71 Cum (g) Pressure gauge - 02 Nos - for raw water and filter water (ii) IRON REMOVAL FILTER :- VERTICAL, SINGLE DECK AND MULTIGRADE (a) Shell IS: 2062 MS fabricated factory made - 1,800 mm dia X 1,500 mm SOH (CAPACITY: 5,000 GPH ) (c) Thickness of Body, Dish end & bed plate - 10 mm x 12 mm x 12 mm (d) Frontal (face) pipe line - will be fabricated from 80 mm ERW pipe (medium grade)
Supply, fixing and connecting altoch dosing pump of capacity 0-6 Ltr/Hr at a pressure of 4Kg /Sqcm with electrical connection of 230 volt AC complete with FRP tank of 100 ltrs including all fittings, complete all as specified and directed.
Supply and laying 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-10) and PP-R plain fittings in trenches/walls/ cellings or laying in floors complete of outer dia 50 mm size including all fittings complete all as specified and directed by Engr-in-charge.
Supply and laying 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-10) and PP-R plain fittings in trenches/walls/ cellings or laying in floors complete of outer dia 40 mm size including all fittings complete all as specified and directed by Engr-in-charge.
Supply and laying 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-10) and PP-R plain fittings in trenches/walls/ cellings or laying in floors complete of outer dia 25 mm size including all fittings complete all as specified and directed by Engr-in-charge.
M & L for construction of brick masonry valve pit of size 900mm x 900mm x900mm (internal dimension) with one brick thick wall in cement mortar 1 : 4, 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) as in bedding/coping and 10 mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit 40 X 40 X 6 mm angle iron frame all round the fixed point by means of 04 Nos holdfast 150 mm long made out of flat iron 40 X 6 mm embedded in PCC block (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) of size 250 X 200 X 150 mm including provision of hinges welded with MS cover 3 mm thick MS sheet cover plate with locking arrangements including 65 mm dia pad lock, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft/loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed.
Supply,installation,testing and commissioning 3 phase and neutral , 415 volts, indoor type , CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT panel fabricated from 2.0 mm thick CRCA sheet, with angle iron frame of 40mm x 40mm x 6 mm, double door , front and back openable type, hinged opening , rubber lining, locking arrangement, with anti-corrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-42, fully compartmentalized design with 4 Nos of bus bar made of copper of ETP grade suitable for 100Amps ( Size of copper strip shall not be less than 25 x 4 mm for each phase and neutral) pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands , cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box / LT Panel with 150mm thick PCC 1:5:10 type E-2 (20mm graded stone aggregate) in foundation , brick work with Fly ash bricks / PCC block work in CM 1:6 , rendering in CM 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The plateform shall be of 450 mm height above ground level complete all as specified and directed with supply and fixing the following:-
Supply, installation, testing and commissioning of silent Diesel Engine driven generating Set 415 Volts, 3 Ph 4 wire, engine as per IS : 10001/10002 and alternator as per IS :60034 complete with relay panel for automatic starting on mains failure, control panel having meters, sound proof canopy and foundation etc. of capacity 250 KVA 4 Stroke, designed to run continuously at 1500 RPM complete all as specified and directed comprising of following accessories:- A) Diesel Engine:- (i) Radiator Cooling (ii) Radiator fan with guard (iii) Fly wheel with starter ring (iv) Dry type air cleaner (v) Vacuum indicator (vi) Mechanical Governor (vii) Exhaust Silencer (viii) Fuel filter (ix) Inline Fuel pump (x) Water pump (xi) Lub oil filter (xii) 24 V electric start system complete with starter, battery charging alternator. (xiii) Engine control panel consisting of starting key switch, lub oil pressure gauge ammeter safety shut down system for low Lube oil pressure & High coolant temperature Engine maintenance manual with spare parts list. (xiv) Exhaust pipe/ stack up to 6.0 meter from top of shed with insulation, structural steel required for supporting exhaust pipe/stack, fixed, sliding supports etc. (xv) First fill of lube oil & coolant (xvi) Residential Silencer with cladding & supports
S & F Servo controlled voltage stabilizer (Confirming as per BIS: 9815: Part 1: 1994 reaffirmed 2009) of capacity 150 KVA 3-phase, 50Hz, Naturally Oil Cooled, Indoor/Outdoor, Unbalanced Type, Copper Wound, Digital Display Type, Relay Free Smooth and Silent Operation with 1 st filling of Transformer oil (IS335: 1993 reaffirmed 2005) having following specification: (i) Input voltage 360V-480V or as per ground requirements (ii) Output voltage stabilized at any designed/desired voltage 415V ± 1% (Adjustable) (iii) Rated frequency 50 Hz (iv) No distortion in wave form (v) Response time shall not exceed 10 mille seconds (vi) Sensitivity (±)1% (vii) Rate of correction 8 Volt/second for single phase and 20 Volt/second for phase to phase (viii) No load losses less than 0.5% (ix) Full load losses less than 2.5% (x) Duty cycle - continuous 24 x 7 (xi) Efficiency more than 95% (xii) Type of load: 3 phase, unbalanced type (xiii) Digital display Voltmeter/Ampmeter With following protections :- (i)Over load/Short circuit protections (ii). High/Low voltage cut off (iii) By pass arrangement in case of emergency (iv) Single phase sequence change protection
S & F Servo controlled voltage stabilizer (Confirming as per BIS: 9815: Part 1: 1994 reaffirmed 2009) of capacity 50 KVA 3-phase, 50Hz, Naturally Oil Cooled, Indoor/Outdoor, Unbalanced Type, Copper Wound, Digital Display Type, Relay Free Smooth and Silent Operation with 1 st filling of Transformer oil (IS335: 1993 reaffirmed 2005) having following specification: (i) Input voltage 360V-480V or as per ground requirements (ii) Output voltage stabilized at any designed/desired voltage 415V ± 1% (Adjustable) (iii) Rated frequency 50 Hz (iv) No distortion in wave form (v) Response time shall not exceed 10 mille seconds (vi) Sensitivity (±)1% (vii) Rate of correction 8 Volt/second for single phase and 20 Volt/second for phase to phase (viii) No load losses less than 0.5% (ix) Full load losses less than 2.5% (x) Duty cycle - continuous 24 x 7 (xi) Efficiency more than 95% (xii) Type of load: 3 phase, unbalanced type (xiii) Digital display Voltmeter/Ampmeter With following protections :- (i)Over load/Short circuit protections (ii). High/Low voltage cut off (iii) By pass arrangement in case of emergency (iv) Single phase sequence change protection
S & F Servo controlled voltage stabilizer (Confirming as per BIS: 9815: Part 1: 1994 reaffirmed 2009) of capacity 10 KVA 3-phase, 50Hz, Naturally Oil Cooled, Indoor/Outdoor, Unbalanced Type, Copper Wound, Digital Display Type, Relay Free Smooth and Silent Operation with 1 st filling of Transformer oil (IS335: 1993 reaffirmed 2005) having following specification: (i) Input voltage 360V-480V or as per ground requirements (ii) Output voltage stabilized at any designed/desired voltage 415V ± 1% (Adjustable) (iii) Rated frequency 50 Hz (iv) No distortion in wave form (v) Response time shall not exceed 10 mille seconds (vi) Sensitivity (±)1% (vii) Rate of correction 8 Volt/second for single phase and 20 Volt/second for phase to phase (viii) No load losses less than 0.5% (ix) Full load losses less than 2.5% (x) Duty cycle - continuous 24 x 7 (xi) Efficiency more than 95% (xii) Type of load: 3 phase, unbalanced type (xiii) Digital display Voltmeter/Ampmeter With following protections :- (i)Over load/Short circuit protections (ii). High/Low voltage cut off (iii) By pass arrangement in case of emergency (iv) Single phase sequence change protection
Supply, install, testing and commissioning of factory made indoor cubical type LT feeder piller box of 2.5 x 1.5 x 0.9 m size totally enclosed weather ,dust vermin proof made of angle iron frame 50mm X50mm X 6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and 2mm thick CRCA (cold rolled cold annealed ) MS sheet bend to shape ,front & back side operated double door with proper hinge and locking arrangement and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete incld internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB, Bus bar cable alley. 800 Amp size of bus bar shall be insulated with colour code/sleeves /tapes sincluding necessary PCC (1:3:6) type C2 for foundation /Platform all as specified and directed. LT panel board shall be completed in all respects with and including the following accessories:-
Supply, install, testing and commissioning of 3 phase and neutral , 415 volts outdoor type , CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT panel fabricated from 3.15 mm thick CRCA sheet for outer shell and 2.0 mm for inner shell, with angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type, double door system, hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 Nos of bus bar made of copper of ETP grade suitable for 500 Amps ( Size of copper strip shall not be less than 50 X 6 mm for each phase and neutral) pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands, cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box / LT Panel with 150 mm thick PCC 1:5:10, E-2 (using 40mm graded stone aggregate) as in foundation , brickwork with fly ash bricks / PCC block work in CM 1:6 , 10mm thick rendering in CM 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified and directed with supply and fixing the following. (For Hangar & Complex)
Supply, install, testing and commissioning of 3 phase and neutral , 415 volts out door type , CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT Feeder Pillar fabricated from 3.15 mm thick CRCA sheet for outer shell and 2.0 mm for inner shell, with angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type, double door system, hinged opening , rubber lining, locking arrangement,with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 Nos of bus bar made of copper of ETP grade suitable for 200 Amps ( Size of copper strip shall not be less than 25x4 mm for each phase and neutral) pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands, cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box with150 mm thick PCC 1:5:10, E-2 (using 40mm graded stone aggregate) as in foundation , brickwork with fly ash bricks / PCC block work in CM 1:6 , 10mm thick rendering in CM 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified and directed with supply and fixing the following. :-.
Supply, install, testing and commissioning of 3 phase and neutral , 415 volts out door type , CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT Feeder Pillar fabricated from 3.15 mm thick CRCA sheet for outer shell and 2.0 mm for inner shell, with angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type, double door system, hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 Nos of bus bar made of copper of ETP grade suitable for 200 Amps ( Size of copper strip shall not be less than 25x4 mm for each phase and neutral) pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands, cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box with150 mm thick PCC 1:5:10, E-2 (using 40mm graded stone aggregate) as in foundation , brickwork with fly ash bricks / PCC block work in CM 1:6 , 10mm thick rendering in CM 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified and directed with supply and fixing the following. :-.
Supply and fix LED street light 45 W with minimum lumen of 4500Lm, PF >0.95 new generation energy saving and environmental friendly long life made up of pressure diecast aluminium housing with high power LED as lighting source cover having driver compartment with IP66 protection and impact resistance with built-in surge protection device suitable for mounting pole including street light GI pipe bracket of medium grade 40mm dia. ,1.5m long bend to required size and shape including two coat of aluminum paint over a coat of red oxide primer complete in all respect all as specified and directed.
S&F thermo plastic terminal box of size not less than 130 x180 x 77 mm with locking arrangement and necessary mounting arrangement on pole with MS clamps, nuts, bolts and washers etc including 01 No MCB 6 Amps and PVC connector 3 phase for cable termination complete all as specified and as directed.
M&L for construction of brick masonry valve pit for protection of Electric cable of size 1.20 x 1.20 x0.90 m (internal dimensions) with one brick thick wall in cement mortar 1 : 4 on 100 mm thick PCC 1:4:8 type D-2 (using 40 mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) as in bedding and coping and 10 mm thick cement plaster in CM (1:4) internally and externally upto 15 cm below ground level , providing valve pit 40 X 40 X 6 mm angle iron frame all round the fixed point by means of 04 Nos holdfast 150 mm long made out of flat iron 40 X 6 mm embedded in PCC block (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) of size 250 X 200 X 150 mm , provision of hinges welded with MS cover 3 mm thick, MS handle of suitable size welded with MS cover and suitable locking arrangement including 65 mm dia Godrej pad lock and applying two coats synthetic enamel paint over a coat of red oxide primer, necessary excavation and earth work , returning filling in, removal of surplus soil to a distance as directed complete all as specified and as directed.
M&L concentina coil fencing with 600 mm dia upto 4m heigth of wall on existing angle iron Y shaped placed 2.4m to 3.00m apart and with 9 horizondal RBT stud tied with GI slips to retain horizondal including necessary bolts of GI barbed wire tied to angle iron, with reinforced barbed tape (RBT)/spring core (2.5mm thick) wire of high tensile strength of 165 Kg/Sqmm with tape (0.52 mm thick) and weight 43.478 gm/mtr complete all as specified and dirceted.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2.0 TR Complete all as specified and directed
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR Complete all as specified and directed
Supply, installation, testing and commissioning of Water Cooler fully stainless steel, electric driven single phase having storage 80 Litres and nominal cooling capacity of 40 Liters per hour, complete all as specified and as directed
Supply and fix refrigerator, electric driven (single phase), of capacity 195 Litres BEE 5 star rated Complete all as specified and as directed
NIRMAL SALES CORPORATION (BID ID -3309463)
CHHABINDRA KUMAR PRADHAN (BID ID -3309349)
CMRGS Infrastructure Projects Ltd (BID ID -3308787)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid