| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC | ₹1.9 Cr | L1 | Accepted-AOC Bidder is L1 and has quoted lowest item rates overall |
| 2 | L2₹2.0 Cr+₹4.5 L (2.33%)Rejected-Finance | ₹2.0 Cr+₹4.5 L (2.33%) | L2 | Rejected-Finance Bidder is Quoted Higher Rate |
| 3 | L3₹2.2 Cr+₹21.7 L (11.2%)Rejected-Finance Q NO A 49 10 VINDHYA COLONY PINORA NOWROZABAD MADHYA PRADESH 484555 | UMARIA | MADHYA PRADESH | 484555 | ₹2.2 Cr+₹21.7 L (11.2%) | L3 | Rejected-Finance Bidder is Quoted Higher Rate |
| 4 | L4₹2.7 Cr+₹77.2 L (39.8%)Rejected-Finance | ₹2.7 Cr+₹77.2 L (39.8%) | L4 | Rejected-Finance Bidder is Quoted Higher Rate |
| 5 | L5₹2.7 Cr+₹77.2 L (39.8%)Rejected-Finance | ₹2.7 Cr+₹77.2 L (39.8%) | L5 | Rejected-Finance Bidder is Quoted Higher Rate |
Tender Value
₹3.5 Cr
EMD Value
₹4.3 L
Closing Date
16 Dec 2023, 6:00 pmClosed
Staff Officer (Civil), Pench Area
Staff Officer (Civil), AGM Office, Pench Area, P.O. Parasia, Dist. Chhindwara (M.P.) 480441
Construction of Boundary wall around different colonies under Pench Area.
2023_WCL_294672_1
pe3350-civ-s-e033-2023-24
Open Tender
Civil Works - Others
Item Rate
270 days
PENCH AREA
AS Per NIT
5 documents required · 5 mandatory
₹4.3 L
3 Feb 2024
27 Nov 2023
18 Dec 2023
27 Nov 2023
16 Dec 2023
27 Nov 2023
27 Nov 2023 - 3 Dec 2023
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : Providing and fixing tie bolt, spring coil and plastic cone in wall shuttering complete as per the direction of Engineer-in-charge 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, elves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III)derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts.
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Cold twisted bars
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Brick work with clamp burnt bricks of class designation 35 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Providing and fixing concertina coil fencing with required dia. 600 mm upto 3.0 m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m aprat and with 9 horizontal R.B.T. stud tied with G.I. staples and G.I clips to retain horizontal including nesessary bolts of G.I. Barbed wire tied to angle iron all complete as per direction of engineer-in-charge with reinforced barbed tape (R.B.T) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg / sqm with tape (0.52 mm thick) of supreme make of equivalent and weight 43.478 gm / metre (cost of M.S.Angle, C.C Blocks shall be paid separately).
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2010 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide clause 801.3.3 fixed over Aluminium composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminium with overall thickness of 4mm and aluminium skin of thickness 0.3 on both side, the ACM shall conform to Table 800-1 of specification and High Intensity Micro ismatck Grade Sheeting shall conform to Table 800-3 of specification. The printing on the high intensity grade sheeting shall conform to Clause 801.3.7 with water based latex optimized transparent ink as specified by the sheeting manufacturer, supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to ground by means of properly designed foundation with M15 grade concrete 450x450x600mm. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts.
Total impact of GST for the purpose of CTC
PANKAJ CONTRACTOR
Ashok kumar agrawal
SIDDIQUI BROTHERS,NAGPUR
KASHINATH DIGARSE
Agrico Steel Engineering Works
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .