Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 17 C LADHOWALI ROAD OPP G G S C SCHOOL JALANDHAR | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹77,024
Closing Date
16 Mar 2026, 3:00 pmClosed
Er. Prabhdeep Singh, Estate Officer
Estate Office, SLIET, Longowal
Repair/ Renovation/Up-gradation of Multi Purpose Hall at SLIET, Longowal
2026_SLIET_900777_2
SLIET/EST/2026/04
Open Tender
Civil Works
180 days
SLIET, Longowal
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
Director, SLIET
₹77,024
23 Apr 2026
5 Mar 2026
17 Mar 2026
5 Mar 2026
16 Mar 2026
6 Mar 2026
SANT LONGOWAL INSITUTE ENGINEERING & TECHNOLOGY, LONGOWAL
TECHNICAL BID
NAME OF FIRM/AGENCY
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 4 way (4 + 12), Double door
b) 6 way (4 + 18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Double pole
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 4 X 16 sq. mm (28mm)
b) 4 X 25 sq. mm (28mm)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3 x 4 sq. mm
b) 3 x 6 sq. mm
c) 1 x 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (Item No. 1.31 DSR 2022)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply of Aluminium, Armoured PVC insulated and PVC sheathed / XLPE LT power cable 4C of 25 square mm 1.1KV grade as per IS 7098 (Part-1) 1988 etc. as per requirement. Make: KEI, L&T, Havells, Polycab
Supply of Aluminium, Armoured PVC insulated and PVC sheathed / XLPE LT power cable 4C of 16 square mm 1.1KV grade as per IS 7098 (Part-1) 1988 etc. as per requirement. Make: KEI, L&T, Havells, Polycab
SITC of concave top outdoor (double door) cubical panel suitable for 415V 3 phase, 50Hz AC supply system having approximate face area 1.52 x 0.91 Mtr. with appropriate depth 0.30 mtr. fabricated in compartmentalized design from CRCA sheet of 2mm thick for frame work & covers, 3 mm. thick for gland plate i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 400Amp capacity extensible type TPN aluminium alloy bus bar of high conductivity, bottom base channel of MS section of appropriate size. Thick & solid connections from main bus bar to switch gear with required size of aluminium bus bar with control wiring of 2.5sq.mm. PVC insulated copper conductor, Indicators, cable gland plate in two half i/c providing & fixing Switchgears. Making provision of stand of angle iron of size 50x50x5mm with height approx. 2 feet & foundation etc. as per requirement.
Main incomer Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 200 A,36KA,FPMCCB (01 PC) Make: L&T, Hager, ABB, Siemens
Outgoing a) Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 KA,TPMCCB (03 PC) Make: L&T, Hager, ABB, Siemens
b) Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 150 A, 16 KA,TPMCCB (03 PC) Make: L&T, Hager, ABB, Siemens
c) Indicator (Red, Yellow, Green) (03 PC)
Supplying & fixing of High Flow wave Wall mounted Fan 450mm sweeps with non metallic balanced blades, low noise, 220V, 50Hz. Make: Crompton/Usha/ Orient/ Havells
Supplying and fixing of heavy duty copper tube (minimum wall thickness of 0.8mm) of appropriate size for 2 Ton Split AC with nitrile insulation and interconnecting 4 core, 1.5 sqmm PVC insulated copper control cable from indoor to outdoor along with required accessories like wall plugs, screws, thimbles etc. as per requirement.
SANT LONGOWAL INSITUTE ENGINEERING & TECHNOLOGY, LONGOWAL
FINANICIAL BID
NAME OF FIRM/AGENCY
TOTAL
SANT LONGOWAL INSITUTE ENGINEERING & TECHNOLOGY, LONGOWAL
FINANICIAL BID
NAME OF FIRM/AGENCY
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 4 way (4 + 12), Double door
b) 6 way (4 + 18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Double pole
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 4 X 16 sq. mm (28mm)
b) 4 X 25 sq. mm (28mm)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3 x 4 sq. mm
b) 3 x 6 sq. mm
c) 1 x 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (Item No. 1.31 DSR 2022)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply of Aluminium, Armoured PVC insulated and PVC sheathed / XLPE LT power cable 4C of 25 square mm 1.1KV grade as per IS 7098 (Part-1) 1988 etc. as per requirement. Make: KEI, L&T, Havells, Polycab
Supply of Aluminium, Armoured PVC insulated and PVC sheathed / XLPE LT power cable 4C of 16 square mm 1.1KV grade as per IS 7098 (Part-1) 1988 etc. as per requirement. Make: KEI, L&T, Havells, Polycab
SITC of concave top outdoor (double door) cubical panel suitable for 415V 3 phase, 50Hz AC supply system having approximate face area 1.52 x 0.91 Mtr. with appropriate depth 0.30 mtr. fabricated in compartmentalized design from CRCA sheet of 2mm thick for frame work & covers, 3 mm. thick for gland plate i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 400Amp capacity extensible type TPN aluminium alloy bus bar of high conductivity, bottom base channel of MS section of appropriate size. Thick & solid connections from main bus bar to switch gear with required size of aluminium bus bar with control wiring of 2.5sq.mm. PVC insulated copper conductor, Indicators, cable gland plate in two half i/c providing & fixing Switchgears. Making provision of stand of angle iron of size 50x50x5mm with height approx. 2 feet & foundation etc. as per requirement.
Main incomer Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 200 A,36KA,FPMCCB (01 PC) Make: L&T, Hager, ABB, Siemens
Outgoing a) Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 KA,TPMCCB (03 PC) Make: L&T, Hager, ABB, Siemens
b) Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 150 A, 16 KA,TPMCCB (03 PC) Make: L&T, Hager, ABB, Siemens
c) Indicator (Red, Yellow, Green) (03 PC)
Supplying & fixing of High Flow wave Wall mounted Fan 450mm sweeps with non metallic balanced blades, low noise, 220V, 50Hz. Make: Crompton/Usha/ Orient/ Havells
Supplying and fixing of heavy duty copper tube (minimum wall thickness of 0.8mm) of appropriate size for 2 Ton Split AC with nitrile insulation and interconnecting 4 core, 1.5 sqmm PVC insulated copper control cable from indoor to outdoor along with required accessories like wall plugs, screws, thimbles etc. as per requirement.
TOTAL
stage.html
html • 0.03 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
DNITMPH.pdf
Tender Documents • 3.18 MB
TBMPH.xls
Additional Documents • 0.05 MB
PBMPH.xls
Additional Documents • 0.05 MB
Download all tender documents and submit your bid