Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹38.2 L+₹24,344.60 (0.64%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹45.2 L+₹7.2 L (18.9%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹45.9 L
EMD Value
₹91,800
Closing Date
13 Apr 2024, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
SPL REPAIRS TO BLDG NO PS57 AND SPECIAL REPAIR REPLACEMENT OF BER COOLERS CEILING FAN AT 213 TRANSIT CAMP UNDER GE NAGROTA
2024_MES_646735_1
GEN-8585/E8
Open Tender
Civil Works
Item Rate
180 days
NAGROTA
Class D category a i
8 documents required · 8 mandatory
₹500
Yes
GE NAGROTA
₹91,800
Yes
29 Jun 2024
16 Mar 2024
15 Apr 2024
16 Mar 2024
13 Apr 2024
1 Apr 2024
Amount
SCHEDULE ‘A’ PART-I ( LIST OF B/R WORKS AT REASI ) Excavating in post holes (or similar holes) each n.exc 0.5 cum in soft / loose soil, getting out returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M&L PCC 1:4:8 Type D2( using 40mm graded crushed stone agg) , as in fdn filling and mass concrete.complete all as specified and directed.
S&F for Rolled sections as in post, main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates of Fe 410-W (Gde- E-250 quality-A)complete all as specified and directed.
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.complete all as specified and directed.
M&L for synthetic enamel painting two coats to steel surfaces over a coat of red oxide primer including preparation of surfaces of any description over 10cm girth or width not other wise described.complete all as specified and directed.
S&F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed.
M&L Hardcore of broken stone or boulder of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L coloured rubberised Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and no pigment complete all as specified and directed.
Supply only Fine aggregate (sand) for laying floor finishes complete all as specified and directed.
M&L PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in copings, kerbs including necessary formwork etc complete all as specified and directed.
Removing excavated material (soil) exc 1.5km and n.exc 5 km and spreading where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Returning, filling, ramming including, spreading, leveling, watering and well ramming in layers n.exc 25cm thick in soft/loose soil.complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in surface channels and drains etc complete all as specified.
Extra for forming fair faces (finished drain of channel 30cm inner grith in cement concrete using extra cement including forms moulds mitred stopped end etc complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil.complete all as specified and directed.
M&L for Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 Mtr mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L for Rendering 15mm thick on fair faces of bricks in CM 1:4 finished even and smooth without using extra cement using WPC @ 3% by weight of cement.complete all as specified and directed.
M & L for Preparing new plastered or unplastered surfaces and applying three coats of white wash on walls complete all as specified and as directed.
SCHEDULE ‘A’ PART-II ( LIST OF E/M WORKS AT REASI ) Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M & L for concealed point wiring for light , fan point with 1.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade,ISI marked controlled by one one-way switch, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories(PVC Casing and caping to be done wherever wiring to be run on ceilings and concrete surfaces including one run of 1.5 sqmm FRLS muti stranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly, including sunk sheet steel terminal box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted with two coates of anti corrosive black bituminous paint over a coat of red oxide primer in and out sides and two coated of aluminium paint on internal surface , including laminated hylum sheet cover, ISI marked of Make" Hylem" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer and make good wall surface complete all as specified and directed. Note : Wiring to be done as per approved colour code in IE rule.Rate includes chase cutting for concealed wiring.
All as per Srl item No. 22 above but for 3 pin socket outlet, 5 Amp on the same board with other switches, complete all as specified and directed.
All as per Srl item No. 22 above, but for 3 pin 5 amp switch socket combination on independent board with other switch complete all as specified and directed.
All as per Srl item No. 22 above but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination on independent board and provision of 1.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .
Material and labour for sub-main wiring with 2 runs of 6 sqmm FRLS PVC insulated, multi-stranded, copper cable, 1100 V grade, along with one run of 4.0 sqmm copper cable for earth continuity wire connected to common earth dolly (Colour code to be followed) drawn through concealed 20 mm dia, medium grade, PVC conduit, including accessories complete all as specified and directed .
S&F in repair/ replacement LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in repair/ replacement LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.complete all as specified and directed.
S&F Polycarbonate switch piano, flush button, single pole, one way 5 Amp , 240 volts ISI marked,complete all as specified and directed.
S&F Polycarbonate ceiling rose, surface type, 3 terminal, 240 , ISI marked, Make Anchor/Havells/ Cona/ Leader (white colur)
S&F socket outlet 2-in-1, 5 pin 5 Amps, 240 volts, flush type complete all as specified and directed.
S&F socket outlet flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 230 volts complete as directed.
S&F Polycarbonate switch piano flush button single pole one way 15 Amp 240 volt ISI marked, complete all as specified and directed.
S&F in repair/ replacement, stepped type electronic fan regulator, Delux model, 100 watt, 240V, flush type. complete all as specified and directed.
S&F in repair/ replacement Lamp holder, insulated body with back plate suitable for batten/angular fittings fixed complete.Make Anchor/Havells/ Cona/ Leader (white colur) with LED lamp of 9 wattcomplete all as specified and directed
M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 02 core.complete all as specified and directed
M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 04 core.complete all as specified and directed
S&F in repair/ replacement, flush to wall, double door MCB DB, SPN 8 way, 240 volts grade, with 200 amps rated bus bar. of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral complete fitted on wooden board first class of suitable size complete all as specified and directed
S&F flush to wall, double door MCB DB, SPN 12 way, 240 volts grade, with 200 amps rated bus bar. of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral complete fitted on wooden board first class of suitable size complete all as specified and directed
S&F in repair/ replacement MCB SPN 40 amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and directed
S&F in repair/ replacement MCB SPN 63 amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and directed
S&F in repair/ replacement MCB SP 240 volts 5 to 40 Amps, 10 KA breaking capacity, 'c' curve including connection with suitable size aluminium / copper lugs complete all as specified and directed
Design,Supply, installation, testing and commissioning of bus bar chember box of size 0.5Mx0.8Mx0.60M depth,(HxBxD) outdoor type alongwith one incoming MCCB 100 A 4 Pole 25 KA factory fabricated made out of CRCA sheet of 3.15 mm thick ,fully enclosed and angle iron frame of size 40 x 40 x 6mm thick and T section with front and rear openable double door shutter, dust and vermin proof and rear opening complete with locking arrangement, having a system of bus bars of aluminium of suitable size of 100 Amps duly insulated and mounted on Epoxy/porcelain insulators in totally enclosed chamber with three phase and neutral 415 volts, AC, system. provn of suitable cable glands, duly powder coated.complete all as specified and directed
M & L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cmx 6.3 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.5 of MES SSR parts-I and including excavation & earth work in any type of soil , disposal of soil , providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type c-1 with 40 mm thick RCC 1:2:4 type B-J cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion, complete all as specified and directed.(Note: Unit rate of earthing deemed to be included with GI wire 4 mm, GI pipe light grade protection pipe 15 mm up to 7.5 RM) complete all as specified and directed
All as per Sl item No 44 above here in before but for using galvanised iron strip 25X4 mm as earthing lead with 40 mm bore protection pipe complete all as specified and directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cable, GI pipes etc, and getting out in soft/ loose type of soil complete all as specified and directed.
M/L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed.
M/L for Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed.
Supply and laying dry river sand cushioning laid in trenches 08 cm below the cable and 15 cm above the cable, complete all as specified and directed. ( Note Punned Thickness shall be measured )
M&L Bricks covering with width equal to length of brick as the mechanical protection to cable with well burned sub-class ‘B’ laid in trenches flat complete all as specified and directed.
SCHEDULE ‘A’ PART-III ( LIST OF B/R WORKS AT NAGROTA ) Dismantling of plain or corrugated steel sheeting of any gauge ,thickness as in roof covering complete all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
S & F Pre-painted galvalume aluminium zinc coatingn GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed
S & F Pre-painted galvalume aluminium zinc coatingn GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge, hips, valley gutter, drip and straight flashing fixed with self tapping screws complete all as specified and directed
M & L for Formwork to sides of concrete foundation, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; similar work; vertical or to batter Rough finished surface of concrete flat.for rough finished surfaces complete all as specified and directed
M & L for Reinforced cement concrete (design mix) M-25 (using 20mm graded aggregate).as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed
M & L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished aurfaces of concrete..for rough finished surfaces complete all as specified and directed
M & L for Reinforced cement concrete (M-25 design mix) Columns, pillars, piers, posts and struts.complete all as specified and directed
M & L for Mild steel TMT bars.10mm dia and over, cut to length, bent to shape required including cracking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed
M & L for Mild steel TMT bars 5mm to 10mm dia, cut to length, in stirrups, spacers & binders. complete all as specified and directed
M & L for Formwork to sides and soffits of floor or roof beams, beam haunchings, griders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete.complete all as specified and directed
M & L for Reinforced cement concrete (M-25 design mix) in Beams, cantilevers, bressummers, lintels over 1.5m span (20 mm graded aggregate) complete all as specified and directed
M & L for Rendering 15mm thick in cement mortar 1:6 on INTERNAL fair faces of Brick walls or on concrete surfaces, finished even and smooth W/O using extra cement complete all as specified and as directed.
S & F rolled mild steel in roof trusses(framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing(Beam,tee, angle, channel or flat sections)incl distance pieces, cleats, etc conforming to grade Fe-410W-(Gde E-250 Quality A) complete all as specified and directed
S & F MS work framed brackets of angles or tees with web and flanges cut to shape drilled and couter sunk for screw, including bending and welding angles, as necessary, gusset plates, riveting etc. n.exc 10 kg each brackets conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed
Demolition of cement concrete (unreinforced) of of any descriptions, above Ground floors not exc 150mm thick, above or below ground level complete all as specified and directed.
M&L of 25 mm thick PCC 1:2:4 type B-0 as a sub base to receive topping layer finished even and rough complete all as specified and as directed.
M & L for Screed bed or bedding layer 15mm thick in cement mortar 1:6 for laying floor finishes/tiles complete all as specified and as directed.
M & L Dark shade/Double charged/ Ultra charged Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.0 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick 1:6 cm screed bed for laying the floor finishes complete all as specified and directed .
M & L for Dark shade/Double charged/ Ultra charged Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles including 10mm thick 1:6 cm screed bed.complete all as specified and directed
M & L for Provision of RCC NP3 150 mm diameter Pipes laid on150 mm thick P.C.C. 1:4:8 bed having depth 0.70M to 1.65M with excavation in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional.complete all as specified and directed
M/S KALSI ENGINEERS AND CONTRACTORS
R C TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .