| Sl No | Description | Qty | Unit | Gaikhonlung Panmei L3 | Sophila Muinao L2 | M/s N.J.B. Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00(SH I :Construction of Gas Chamber ) | ||||||
| 2.00 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil. | 34.48 | m3 | 333 ₹11,481.84 | 327 ₹11,274.96 | 313 ₹10,792.24 Lowest |
| 3.00 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 11.49 | m3 | 220 ₹2,527.8 | 214 ₹2,458.86 | 206 ₹2,366.94 Lowest |
| 4.00 | Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km | 43.23 | m3 | 1,478 ₹63,893.94 | 1,451 ₹62,726.73 | 1,388 ₹60,003.24 Lowest |
| 5.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size). | 14.67 | m3 | 10,920 ₹1,60,196.4 | 10,718 ₹1,57,233.06 | 10,276 ₹1,50,748.92 Lowest |
| 6.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.) | 4.24 | m3 | 14,799 ₹62,747.76 | 14,526 ₹61,590.24 | 13,886 ₹58,876.64 Lowest |
| 7.00 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.) | 1.6 | m3 | 16,336 ₹26,137.6 | 16,034 ₹25,654.4 | 15,385 ₹24,616 Lowest |
| 8.00 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.) | 7.37 | m3 | 16,842 ₹1,24,125.54 | 16,532 ₹1,21,840.84 | 15,833 ₹1,16,689.21 Lowest |
| 9.00 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a ) Thermo-Mechanically Treated bars | 1,521.07 | Kg | 138 ₹2,09,907.66 | 135 ₹2,05,344.45 | 129 ₹1,96,218.03 Lowest |
| 10.00 | Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete. | 32.35 | m2 | 504 ₹16,304.4 | 495 ₹16,013.25 | 473 ₹15,301.55 Lowest |
Tender Value
₹3.7 Cr
EMD Value
₹7.4 L
Closing Date
4 Jan 2024, 1:00 pmClosed
Executive Engineer (I/E),MPHC Ltd.
MPHC Complex
Infrastructure Development of State Institute of Hotel Management at Nongmaiching, Imphal East.
2023_MPHCL_2295_1
05/EE(I/E)/MPHC/2023-24
Open Tender
Civil Works
Works
365 days
As Per Tender Document
Please refer Tender documents.
11 documents required · 11 mandatory
₹25,000
Managing Director, MPHC Ltd.
₹7.4 L
2 Apr 2024
23 Dec 2023
4 Jan 2024
23 Dec 2023
4 Jan 2024
23 Dec 2023
23 Dec 2023 - 2 Jan 2024
Amount
(SH I :Construction of Gas Chamber )
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a ) Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, Pillars, Piers, Abutments, Posts and Struts.
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers,with water proof ply 12mm thick.
(d ) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick.
Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 Kanhaighat coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : (i) Cement mortar 1:6(1 cement: 6 Kanhaighat coarse sand)
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in : (i) cement mortar 1:4 (1 cement : 4Kanhaighat coarse sand)
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : (a) Local best quality Tolhao wood.
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws.(a) Local best quality Tolhao wood.(35mm thick)
Providing and fixing expanded metal 20x60mm strands 3.25mm wide and 1.6mm thick for windows etc. including 62x19mm beading of Ilnd class teak wood and priming coat with approved steel primer all complete.
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :(i) 300 x 16 mm
Providing and fixing bright finished brass tower bolts (barrel type)with necessary screws etc. complete : (a) 250x10 mm
Providing & fixing Brass handles with necessary screws etc. complete.(a) 125mm
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.2.1 40mm thick with 20mm nominal size stone aggregate.
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with (i) Precoated galvanised iron profile sheets 0.50 mm thick
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc.complete. (a) Electric resistance or induction butt welded tubes
12mm cement plaster of mix : 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster on rough side of single or half brick wall of mix (i) 1:4 (1 cement : 4 Kanaighat coarse sand).
15 mm cement plaster 1:3 (1 cement: 3 Kanhaighat coarse sand) finished with afloating coat of neat cement on the roughside of single or half brick wall.
Finishing walls with textured exterior paint of required shade : (i) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
(SH II :Construction of Laundry Shed )
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a ) Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete.
Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 Kanhaighat coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : (i) Cement mortar 1:6(1 cement: 6 Kanhaighat coarse sand)
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.2.1 40mm thick with 20mm nominal size stone aggregate.
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with (i) Precoated galvanised iron profile sheets 0.50 mm thick
Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick.
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc.complete. (a) Electric resistance or induction butt welded tubes
15 mm cement plaster 1:3 (1 cement: 3 Kanhaighat coarse sand) finished with afloating coat of neat cement on the roughside of single or half brick wall.
Providing and fixing aluminium work for doors, windows,ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber/ Neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleatangle,Aluminium snap beading for glazing / panelling, C.P. brass /stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately).(i) For fixed portion
(ii) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
(SH III:Construction of Linen Room)
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a ) Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete.
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4 Kanhaighat C/Sand)
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.2.1 40mm thick with 20mm nominal size stone aggregate.
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with (i) Precoated galvanised iron profile sheets 0.50 mm thick
Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick.
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc.complete. (a) Electric resistance or induction butt welded tubes
15 mm cement plaster 1:3 (1 cement: 3 Kanhaighat coarse sand) finished with afloating coat of neat cement on the roughside of single or half brick wall.
Providing and fixing aluminium work for doors, windows,ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber/ Neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleatangle,Aluminium snap beading for glazing / panelling, C.P. brass /stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately).(i) For fixed portion
(ii) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
(SH IV:Providing roofing and flooring of Open to Sky area of the Institutional Building)
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a ) Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for:
(a) Columns, Pillars, Piers, Abutments, Posts and Struts.
(b) Lintels, beams, plinth beams, girders, bressumers and cantilevers,with water proof ply 12mm thick.
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in : (i) cement mortar 1:4 (1 cement : 4Kanhaighat coarse sand)
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : (a) Local best quality Teak wood.
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws.(a) Local best quality Teak wood.(35mm thick)
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10 x15cm 1:3:6 (1 cement : 3 Kanaighat coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.(a) Double charge vitrified tile polished finish of size (i) Size of Tile 600 x 600 mm
Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete (i) 8mm thick
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with (i) Precoated galvanised iron profile sheets 0.50 mm thick
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc.complete. (a) Electric resistance or induction butt welded tubes
12mm cement plaster of mix : 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster on rough side of single or half brick wall of mix (i) 1:4 (1 cement : 4 Kanaighat coarse sand).
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :.(i) Water thinnable cement primer
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with textured exterior paint of required shade : (i) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade (i) Two or more coats
(SH V :Construction of Boundary fencing with Barbed Wire and M.S Angle for a length of 310 Rm)
1.52 m high fencing with angle iron posts 2.13 m long 50x50x6 mm plates at every 2.44 m apart embedded in cement concrete block of mix 1:5:10 (1 cement : 5 fine sand :10 stone/agg/40mm gauge) 30.5x30.5x61 cm corner and at every 12th posts to be strutted, provided with 8 (eight) horizontal lines and 2(two) diagonals of G.I barbed wire 0.124 kg/m between two posts filled and fixed with G.I. staples i/c earth work in excavation etc complete.
(SH VI:-Construction of Internal Raods)
Providing laying and compacting Granular Base/Sub base with naturally occuring Sand Gravel Material free from organic ore other deleterious constituent spreading with Motor Grader and compacted by rolling with power roller of 8-10 capacity in layers not exceeding 150mm (spread thickness)
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density.
(A )By Manual Means
(i) Grading-I (Aggregate size – 63mm to 45mm) (a) Using Screening Crushable type such as Moorum or Gravel
(ii) Grading-II ( Aggregate size – 53mm to 22.4mm) (a) Using Screening Crushable type such as Moorum or Gravel
Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means.
Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 percent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects. ( b) VG-30
Seal Coat (Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats) (i) Case -I:Type A
(SH VII: Land Development )
Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller or wooden or steel rammer and rolling every third and topmost layer with power roller of minimum 8 tonne and dressing up in embankment for roads marginal banks flood banks and guide bank lead upto 15 KM and lift upto 1.5 metre
(SH VIII: Construction of 50KL Capacity Ground Sump )Add
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:4 :8(1 cement :4Kanhaighat coarse sand :8graded stone aggrt. 40mm nominal size).
RCC WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a ) Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete.
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers,with water proof ply 12mm thick.
(g) Walls (any thickness) including attached pilasters, buttresses,plinth and string courses etc.
(d ) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick.
(e) Edges of slab and breaks in floors and walls (i) Under 20cm wide
FINISHING
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement.
P/F C.I. Cover with frame (for manhole and chambers) (i) 600 mm x 450 mm (heavy duty) (38 Kg)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
25 mm nominal outer dia Pipes
SH IX: Installation of 250 KVA 3 phase distribution transformer, External service connection and compound lighting.
Providing & Installation of 11/0.4 KV 250 KVA Distribution Transformer i/c 2 nos. of 9m steel tubular poles, channels,angles,clamps, A.B. switch, D.B. box,sub-station earthing, sub-station fencing, energy meter, danger board, lightening arrestor and pole muffling complete set etc as reqd.
Standard bill of materials for one Km. of 11 KV line with ACSR Rabbit (6/1/3.35 mm) conductor with 9 m long steel tubular pole.
S/F swaged type steel tubular pole 8 mt.long as per 410-SP-14 conforming to IS-2713 (Pt-II) 1980 with bracket in cement concrete 1:3:6 (1 cem.:3 c/sand : 6 gr. St. 40mm n/size) foundation i/c excavation and refilling etc. as reqd.
Supply and drawing of AB cable of size (3x50+1x35)mm2
S/F L.T. cross arm 50X50X6mm - 2 wires
S/F back clamp for L.T. pole
S/F stay set complete with stay wire & stay insulator etc.as reqd.
Design, supply, installation testing and commissioning of L.T.Panel board of dust and vermin proof mounted with thickness of 16 SWG metal clad sheet with suitable for use at 3- Phase, 4 pole,50 Hz 415V fitted with the following switch gears of four way outgoing conforming to IS/IEC:60947-2, HSN Code 8537 :-
1. 200 amp. TPN on load changeover switch - 1 No.
2. 200 amp. TPN bus bar chamber - 1 No.
3. 125 amp. TPN thermal adjustable MCCB - 4 Nos.
P/L 70mm2 four core pvc ins.(heavy duty) Al. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Supply, installation, testing and commissioning of 8 mtr. High hot dip galvanised octagonal poles with 130mm bottom A/F & 70mm top A/F made up of 3mm thick HT sheet alongwith base plate of size 200x200x12mm thick with complete foundation as reqd. (Without bracket).
S/F G.I. bracket 1 mt. long single arm etc.as reqd.
S/F G.I. bracket 1 mt. long double arm etc.as reqd.
S/D of 2.5 sq mm FR Cu. Conductor.
SITC LED Street Light 60W 757K made of pressure dia housing with toughned glass and individual high power LED with secondary optics IP66 protection & impact resistance of (Havells) ENDURAPEARLPLUSL60W complete with all accessories i/c connection etc. as reqd.
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Sophila Muinao
Gaikhonlung Panmei
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.17 MB
BOQ_2540.xls
BOQ • 0.32 MB
Tender_documents.pdf
Tender Documents • 0.46 MB
Schedule_of_materials.pdf
Tender Documents • 0.64 MB
Drawing.pdf
Tender Documents • 1.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .