Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Capital (Works)
Above/Below/Par
GENERAL
34 conditions · 7 needing a document upload
Mandate form should be uploaded as per attached format in document tab.
GST : Tenderer has to fulfill GST Compliance as per Govt. norms
Tenderer may upload GST registration number and certificate
PAN Card: Tenderers are required to upload their Permanent Account Number (PAN) card
Declaration of proprietorship/partnership firm and necessary document should be submitted along with tender
Employment/Partnership etc. of Retired Railway Employees: (a) Should a tenderer i) be a retired Engineer of the gazetted rank or any other gazetted officer working before his retirement, whether in the executive or administrative capacity or whether holding a pensionable post or not, in the Engineering or any other department of any of the railways owned and administered by the President of India for the time being, OR ii) being partnership firm / joint venture (JV) / registered society / registered trust etc have as one of its partners a retired Engineer of the gazetted rank or any other gazetted officer working before his retirement, OR iii) being an incorporated company have any such retired Engineer of the gazetted rank or any other gazetted officer working before his retirement as one of its directors AND in case where such Engineer or officer had not retired from government service at least 1 year prior to the date of submission of the tender THEN the tenderer will give full information as to the date of retirement of such Engineer or gazetted officer from the said service and as to whether permission for taking such contract, or if the Contractor be a partnership firm or an incorporated company, to become a partner or director as the case may be, has been obtained by the tenderer or the Engineer or officer, as the case may be from the President of India or any officer, duly authorized by him in this behalf, shall be clearly stated in writing at the time of submitting the tender. b) In case, upon successful award of contract, should a tenderer depute for execution of the works under or to deal matters related with this contract, any retired Engineer of gazette rank or retired gazetted officer working before his retirement in the Engineering or any other department of any of the railways owned and administered by the President of India for the time being, and now in his employment, then the tenderer will ensure that retired Engineer or retired gazetted officer had retired from government service at least 1 year prior to the date of his employment with tenderer and in case he had retired from service within a year then he possesses the requisite permission from the President of India or any officer, duly authorized by him in this behalf, to get associated with the tenderer . c) Should a tenderer or Contractor being an individual, have member(s) of his family or in the case of partnership firm/ company / joint venture (JV) / registered society / registered trust etc. one or more of partners(s)/shareholder(s) or member(s) of the family of partner(s)/ shareholder(s) having share of more than 1% in the tendering entity employed in gazetted capacity in the Engineering or any other department of the railway, then the tenderer at the time of submission of tender, will inform the authority inviting tenders the details of such persons. If information as required as per 16.a), b), c) above has not been furnished, contract is liable to be dealt in accordance with provision of clause 62 of Standard General Condition of contract. Format for declaration in this regard is attached with the tender document. ( Click here to download Format)
"Bid Security: (1) (a) The tenderer shall be required to submit the Bid Security with the tender for the due performance with the stipulation to keep the offer open till such date as specified in the tender, under the conditions of tender. The Bid Security shall be as under: Value of the Work and Bid Security : For all works, 2% of the estimated cost of the work. Note: (i) The Bid Security shall be rounded off to the nearest 100. This Bid Security shall be applicable for all modes of tendering. (ii) Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' shall be exempted from payment of Bid Security detailed above. (iii) Labour Cooperative Societies shall submit only 50% of above Bid Security detailed above. (b) It shall be understood that the tender documents have been issued to the tenderer and the tenderer is permitted to tender in consideration of stipulation on his part, that after submitting his tender he will not resile from his offer or modify the terms and conditions thereof in a manner not acceptable to the Engineer. Should the tenderer fail to observe or comply with the said stipulation, the aforesaid amount shall be liable to be forfeited to the Railway. (c) If his tender is accepted, this Bid Security mentioned in sub para (a) above will be retained as part security for the due and faithful fulfillment of the contract in terms of Clause 16 of the Standard General Conditions of Contract. The Bid Security of other Tenderers shall, save as herein before provided, be returned to them, but the Railway shall not be responsible for any loss or depreciation that may happen thereto while in their possession, nor be liable to pay interest thereon.
The Bid Security shall be deposited either in cash through epayment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- VIA and shall be valid for a period of 90days beyond the bid validity period. In case, submission of Bid Security in the form of Bank Guarantee, following shall be ensured: i. A scanned copy of the Bank Guarantee shall be uploaded on e-Procurement Portal (IREPS) while applying to the tender. ii. The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document before closing date for submission of bids (Le. excluding the last date of submission of bids) . iii. Non submission of scanned copy of Bank Guarantee with the bid on e-tendering portal (IREPS) and/or non submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. iv. The Tender Security shall remain valid for a period of 90 days beyond the validity period for the Tender. v. The details of the BG, physically submitted should match with the details available in the scanned copy and the data entered during bid submission time, failing which the bid will be rejected vi. The Bank Guarantee shall be placed in an envelope, which shall be sealed. The envelope shall clearly bear the identification "Bid for the ***** Project" and shall clearly indicate the name and address of the Bidder. In addition, the Bid Due Date should be indicated on the right hand top corner of the envelope. vii. The envelope shall be addressed to the officer and address as mentioned in the tender document. viii. If the envelope is not sealed and marked as instructed above, the Railway assumes no responsibility for the misplacement or premature opening of the contents of the Bid submitted and consequent losses, if any, suffered by the Bidder.
The successful bidder shall submit the Performance Guarantee (PG) in any of the following forms, amounting to 5% of the original contract value and Additional Performance Guarantee as per Clause 16(4)(h) of GCC-2022, in any of the following forms:- (i) A deposit of Cash; (ii) Irrevocable Bank Guarantee; (iii)Government Securities including State Loan Bonds at 5% below the market value; (iv) Pay Orders and Demand Drafts tendered by any Scheduled Commercial Bank of India; (v) Guarantee Bonds executed or Deposits Receipts tendered by any Scheduled Commercial Bank of India; (vi) Deposit in the Post Office Saving Bank; (vii) Deposit in the National Savings Certificates; (viii) Twelve years National Defence Certificates; (ix) Ten years Defence Deposits; (x) National Defence Bonds and (xi) Unit Trust Certificates at 5% below market value or at the face value whichever is less. Also, FDR in favour of FA&CAO (free from any encumbrance) may be accepted. New Para 16(4) (h) of Part-II of GCC'22: If a tender is accepted on the quoted rates of bidder which is below the advertised tender value, an additional performance security shall be submitted by the bidder as below: (i) If Bid quoted in % of advertised cost is Below 0 - 5% (inclusive), Additional Performance Guarantee (%) will be 'Nil'. (ii) If Bid quoted in % of advertised cost is Below 5%, Additional Performance Guarantee (%) will be '5%.
Performance Guarantee : The successful bidder shall have to submit a Performance Guarantee (PG) within 21 (Twenty one) days from the date of issue of Letter of Acceptance (LOA). Extension of time for submission of PG beyond 21 (Twenty one) days and upto 60 days from the date of issue of LOA may be given by the Authority who is competent to sign the contract agreement. However, a penal interest of 12% per annum shall be charged for the delay beyond 21(Twenty one) days, i.e. from 22ndday after the date of issue of LOA. Further, if the 60thday happens to be a declared holiday in the concerned office of the Railway, submission of PG can be accepted on the next working day. In all other cases, if the Contractor fails to submit the requisite PG even after 60 days from the date of issue of LOA, the contract is liable to be terminated. In case contract is terminated railway shall be entitled to forfeit Bid Security and other dues payable to the contractor against that particular contract, subject to maximum of PG amount. In case a tenderer has not submitted Bid Security on the strength of their registration as a Startup recognized by Department of Industrial Policy and Promotion (DIPP) under Ministry of Commerce and Industry, DIPP shall be informed to this effect. The failed Contractor shall be debarred from participating in re-tender for that work. However the clause may also applicable as amended time to time.
The Performance Guarantee shall be submitted by the successful bidder after the Letter of Acceptance (LOA) has been issued, but before signing of the contract agreement. This P.G. shall be initially valid upto the stipulated date of completion plus 60 days beyond that. In case, the time for completion of work gets extended, the Contractor shall get the validity of P.G. extended to cover such extended time for completion of work plus 60 days.
The value of PG to be submitted by the Contractor is based on original contract value and shall not change due to subsequent variation(s) in the original contract value.
The Performance Guarantee (PG) shall be released after physical completion of the work based on 'Completion Certificate' issued by the competent authority stating that the Contractor has completed the work in all respects satisfactorily. The Security Deposit shall, however, be released only after expiry of the maintenance period and after passing the final bill based on No Claim Certificate from the contractor.
The value of PG to be submitted by the Contractor is based on original contract value and shall not change due to subsequent variation(s) in the original contract value.
Whenever the contract is rescinded, the Security Deposit shall be forfeited and the Performance Guarantee shall be encashed. The balance work shall begot done independently without risk cost of the failed contractor. The failed contractor shall be debarred from participating in the tender for executing the balance work. If the failed contractor is a JV or a Partnership firm,then every member/partner of such a firm shall be debarred from participating in the tender for the balance work in his/her individual capacity or as a partner of any other JV/partnership firm.
In case of Bank Guarantee submitted as a Performance Guarantee then Bank confirms that it is on the SFMS (Structured Financial Messaging System) and shall invariably send the advice of this Bank Guarantee to the following bank details - IFSC CODE - SBIN000RAIL IFSC TYPE - BRANCH BANK NAME - STATE BANK OF INDIA BRANCH NAME - RAIL CITY NAME - NAVI MUMBAI ADDRESS - SECTOR-11, CBD BELAPUR, NAVI MUMBAI DISTRICT - NAVI MUMBAI STATE - MAHARASHTRA BG ENABLED - YES
The Railway reserves the right of not to invite tenders for any of Railway work or works or to invite open or limited tenders and when tenders are called to accept a tender in whole or in part or reject any tender or all tenders without assigning reasons for any such action.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Shramikkalyan portal:- (i) Contractor is to abide by the provisions of various labour laws in terms of above clause 54,55, 55-A and 55-B of Indian Railways Standard General Conditions of Contract. In order to ensure the same, an application has been developed and hosted on website 'www.shramikkalyan.indianrailways.gov.in'. Contractor shall register his firm/company etc. and upload requisite details of labour and their payment inthis portal. These details shallbe available in public domain. The registration /updation in Portal shall be done as under: (a)Contractor shall apply for one time registration of his company/firm etc. in the Shramikkalyan portal with requisite details subsequent to issue of Letter of Acceptance. Engineer shall approve the contractor's registration in the portal within 7 days of receipt of such request. (b)Contractor once approved by any Engineer, can create password with login ID (PAN No.) for subsequent use of portal for all Letter of Acceptances (LoAs)issued in his favour. (c)The contractor once registered on the portal, shall provide details of his Letter of Acceptances (LoAs)/ Contract Agreements on shramikkalyan portal within 15 days of issue of any LoA for approval of concerned Engineer. Engineer shall update (if required) and approve the details of LoA filled by contractor within 7 days of receipt of such request.(d)After approval of LoA by Engineer, contractor shall fill the salient details of contract labours engaged in the contract and ensure updating ofeach wage payment to them on shramikkalyan portal on monthly basis. (e)It shall be mandatory upon the contractor to ensure correct and prompt uploading of all salient details of engaged contractual labour & payments made thereof after each wage period. (ii)While processing payment of any'On Account Bill' or 'Final Bill' or release of 'Advances' or 'Performance Guarantee / Security deposit', contractor shall submit a certificate to the Engineer or Engineer's representatives that "I have uploaded the correct details of contract labours engaged in connection with this contract and payments made to them during the wage period in Railway's Shramikkalyan portal at 'www.shramikkalyan.indianrailways.gov.in' till____Month,____Year.
As per directive of Railway Higher Authorities, police verification of all contractors and contractual staffs is mandatory regardless of their role or duration of engagement.
Electrical work for Interlocking of 6 nos. LC Gates: HA-2, HA-4, HA-7, HA-10, HA-16, HA-20 in Howrah-Amta section.
ELEC-SRC-26-27-LCAMTA-5
ELEC-SRC-26-27-LCAMTA-5
Open
Works - General
12 Months
Howrah, West Bengal
₹0
₹80,300
1 Jun 2026
7 May 2026
18 May 2026
79 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 40,16,628.27 | ||
| — | 48.00 | — | — | ||
| "Supply of 20W or higher wattage LED tube light with Batten ( integrated electronic driver).As per CEGE approved Specification for LED tube light-high power,6500 Kelvin, output,220V, 50Hz AC , Aluminium Extruded with constant current driver with short circuit and overload protection etc. | — | — | — | 24,000 | |
| — | 48.00 | — | — | ||
| Fixing and Commisioning of 20W or higher wattage LED tube light with Batten | — | — | — | 2,299.2 | |
| — | 12.00 | — | — | ||
| "Supply of street light LED 45 watt or higher wattage street light as per Specification No. CEE/S/185/ LED/12/21/Rev-0, 2021 dated 22/12/2021 suitable for fixing in 42.4mm arm, including system lumen efficiency 110 lm/Watt (±5%), Power factor 0.90 at full load, normal voltage of luminary: 230V AC ±5%, 50HZ, Operating Voltage range: 140-270V AC, working temperature should be -10°C to 55°C, The complete unit cubicle together with its mounting arrangement shall be subjected to shock testing as per latest IEC 61373, LED life expectancy 50000 burning hrs., Colour temperature range 5500-6500K, Colour Rendering Index (CRI) 70 with driver featuring (Constant current driver with open & short circuit protection), THD<10%, efficiency 85%, SPD for External surge protection-of minimum 10KV to be separately installed with the each fixture (As per ANSI C 136'2- 2014), Lamp shall be Distortion free, clear, heat resistance toughened glass of thickness 4.00 mm, polycarbonate lens Fire retardant FR grade, Ingress Protection of IP-66 or better, The housing shall be single housing, side entry high pressure aluminium die cast/extruded aluminium, grey colour corrosion-resistant polyester powder coated with separate optical and control gear compartments, high conductivity (LM/6/ADC12/LM24) with integral heat sink and heat proof silicon rubber, silicon gasket between housing & cover, Impact Resistance of IK-07 or better. Cover to be fixed to the housing by mean of stainless steel screws and stainless steel fastener. 1) Unit shall with stand 300 volt AC for 1 minutes and cut off. It will automatically ON when voltage comes in oparating voltage range. Warranty for free replacement for 05 years. 2) Shall be oparated with reverse polarity for 3 minutes at maximum value of voltage range between supply terminal and body off the unit. 3) Shall be tested at 1500 volt AC for 1 minutes between supply terminals and body of the unit. | — | — | — | 28,179.24 | |
| — | 12.00 | — | — | ||
| Fixing and commissioning of LED 45 watt or higher wattage street light including wiring of light from loop box with proper termination by Pin Type Terminal End Lugs including fixing to the arm by mean of stainless steel screws and stainless steel fastener as per site requirenment, to complete the job. | — | — | — | 2,752.2 | |
| — | 18.00 | — | — | ||
| Supply of Wall Mounted Fan with Brushless DC (BLDC) Motor, sweep size 400 mm with feature of Oscillaton & Vertcal Adjustable Tilt Mechanismn Minimum Air Delivery 65 cubic meter/min,Rated Voltage: 230 V, 50Hz, Single phase AC, Motor Winding Material: Copper, No. ofBlades-3, Provided with Pull cord or string based speed control mechanism with minimum 3 speed stepsn Colour: White, Minimum Service Value 1.43 as per BEE 5 star rating (BEE's Schedule- 32, Table & Wall-Mounted Fan), Conforming to IS 555:1979 (Reaffirmed Year: 2020) with all amendments. | — | — | — | 97,920 | |
| — | 18.00 | — | — | ||
| Fixing and Commissioning of Wall Mounted Fan WITH 5 STAR and above RATING 400 mm size , suitable for 230V, 50Hz, AC supply as per site requirement. | — | — | — | 2,734.02 | |
| — | 21.00 | — | — | ||
| "Supply of Heavy duty Exhaust Fans 300 mm , 1400 RPM suitable for 230V, 50Hz, AC supply, Conformity to Indian Standrad IS: 2312 (latest).accessories such as Frame, Legs Set,Rubber Clamps & Other Hardware - inclusive in the scope of supply. | — | — | — | 63,000 | |
| — | 21.00 | — | — | ||
| Fixing and commissioning of Heavy Duty Exhaust Fans as per consignee requirement. | — | — | — | 3,210.27 | |
| — | 24.00 | — | — | ||
| Supply of Brushless DC (BLDC) Motor Ceiling Fan, ISI marked, Sweep size: 1400 mm, Minimum Air delivery-210 Cubic Meter/Min, total harmonic distortion- 8% [max], Rated Voltage: 230 V,50HZ Single phase AC, Blade thickness (Min): 1.1mm, Blade material : Aluminium, Bearing: Double ball bearings, Down rod size (without shackle) : 300mm, Shank & Shackle thickness(Min) : 2mm, canopy : 2 nos., colour standard: white, BEE rating : 5 star (as per Ministryof Power Notification Number: S.O. 2210 (E) and S.O. 2211 (E) dated. 12th May 2022 orlatest), Rated power-28 watt [max], Warranty [Min] 30 Months. Conforming to- (i)IS:374/2019 with Amendment No. 1/2022 or latest (ii)IS:302 (Part 2/Sec 80) - For safetyrequirement (iii)IS:14700 (Part 3/Sec2) for THD. Speed control with electronic regulator(step type with minimum 5 running positions) and Regulators shall be provided with radioand television interference suppressing devices as per clause 10.7 of Amendment No. 1/2022 to IS 374/2019 or latest. | — | — | — | 70,169.52 | |
| — | 24.00 | — | — | ||
| Fixing and commissioning of Brushless DC (BLDC) Motor Ceiling Fan, ISI marked, Sweep size: 1400 mm, suitable for 230V, 50Hz, AC supply confirming to Class:I of IS: 374/latest. Fixing of the fan shall be done with suitable clamp, hook, nut/bolts etc. and connection with flexible twin twisted multistrand Copper wire and removing of the existing old fan (if any) and handing over of the same to Railway Store with clear acknowledgement, as per site requirement. | — | — | — | 3,291.36 | |
| — | 18.00 | — | — | ||
| "Supply of modular electrical switches and accessories with 6A/16 A, 6 Pin Socket, with Stainless Steel boxes and all other accessories to complete job for concealed wiring. Specs: Modular Electrical Switch, 16 A, 230 V, SP, 1 Way, 1 Module, Unenclosed type as per Clause no.7.1.3, Method of Activation of switch shall be of Rocker type as per Clause no. 7.1.5, Switch shall be Flush type as per Clause no.7.1.6 and shall be installed as per Design A mentioned in the Clause no.7.1.7, Current carrying material as per Clause no. 22.5, with cover made of tough non-ignitable insulating material and bare of tough non-ignitable insulating material or of vitrified ceramic material, Conforming to IS:3854/1997 (reaffirmed 2017) with latest amendments and ISI mark, Modular type Socket outlet, 6 pin, 6A & 16A, 230V, 2 Module, Shuttered (Operation of Shutter should be independent of Earthing Point), Cover made of tough Non-Ignitable insulating material, material of base -vitrified ceramic, Conforming to IS : 1293-2019, Amendment no. 1 or latest with ISI mark, with moduler cover plate and Stainless Steel boxes and all other accessories including stainless steel fastener, Pin Type Terminal End Lugs to complete job as per specification attached or with latest amendment or specification issued from HQ/GRC if any time to time. | — | — | — | 23,688 | |
| — | 18.00 | — | — | ||
| Fixing and commissioning of modular electrical switches and accessories with 6A/16 A, 6 Pin Socket, with Stainless Steel boxes, moduler cover plate duly Concealed in wall surface including all other accessories to complete job with latest amendment or specification issued from HQ/GRC if any time to time, including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. (Wiring will be covered under Shedule item No. as per site requirement). | — | — | — | 626.04 | |
| — | 24.00 | — | — | ||
| "Supply of modular PC Board consisting of 03 nos. switches with inbuilt LED indication, 03 nos. sockets and modular SP MCB 10-16A, 10kA, Type B- 01 No. with Stainless Steel 12M Box and all other accessories to complete job for concealed wiring. Specs: Modular Electrical Switch, 6 A, 230 V, SP, 1 Way, 1 Module, Unenclosed type as per Clause no.7.1.3, Method of Activation of switch shall be of Rocker type as per Clause no. 7.1.5, Switch shall be Flush type as per Clause no.7.1.6 and shall be installed as per Design A mentioned in the Clause no.7.1.7, Current carrying material as per Clause no. 22.5, with cover made of tough non-ignitable insulating material and bare of tough non-ignitable insulating material or of vitrified ceramic material, Conforming to IS:3854/1997 (reaffirmed 2017) with latest amendments and ISI mark and Modular type Socket outlet suitable for 3 pin plug, 6A, 230V, 2 Module, Shuttered (Operation of Shutter should be independant of Earthing Point), Cover made of tough Non-Ignitable insulating material, material of base -vitrified ceramic, Conforming to IS : 1293-2019, Amendment no. 1 or latest with ISI mark. with modular SP MCB 10A, 10kA, Type B- 01 No. ISI marked, rated voltage: 240V AC, conforming to IS/IEC 60898-1:2015 (Reaffirmed Year:2024) or latest, with rated short circuit current capacity 10KA, fixed unadjustable time current characteristics suitable for use in protection of industrial, commercial and domestic electrical installations. along with 12M stainless steel Box, moduler cover plate and Stainless Steel boxes and all other accessories including stainless steel fastener, Pin Type Terminal End Lugs to complete job as per specification attached or with latest amendment or specification issued from HQ/GRC if any time to time. | — | — | — | 40,780.56 | |
| — | 24.00 | — | — | ||
| Fixing and commissioning of modular PC Board consisting of 03 nos. switches with inbuilt LED indication, 03 nos. sockets and modular SP MCB 10-16A, 10kA, Type B- 01 No. with Stainless Steel 12M Box, moduler cover plate duly Concealed in wall surface including all other accessories to complete job with latest amendment or specification issued from HQ/GRC if any time to time, including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. (Wiring will be covered under Shedule item No. as per site requirement). | — | — | — | 834.72 | |
| — | 175.00 | — | — | ||
| Concealed Wiring of light and fan point by 1.5 sq. mm, Single Core, Multistrand (22/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR- LSH), PVC insulated Cable of 1100V grade, Type-C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked. Earthing the point with 1.5 sq. mm, Single Core, Multistrand (22/0.3mm), Copper Conductor (flexible), Unsheathed, FR-LSH, PVC insulated Cable of 1100V grade, Type-C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked,through PVC Conduit Pipe of Nominal Size 20mm/25mm(as per site requirement) and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark. Modular Electrical Switch, 6 A, 230 V, SP, 1 Way, 1 Module, Unenclosed type as per Clause no.7.1.3, Method of Activation of switch shall be of Rocker type as per Clause no. 7.1.5, Switch shall be Flush type as per Clause no.7.1.6 and shall be installed as per Design A mentioned in the Clause no.7.1.7, Current carrying material as per Clause no. 22.5, with cover made of tough non-ignitable insulating material and bare of tough non-ignitable insulating material or of vitrified ceramic material, Conforming to IS:3854/1997 (reaffirmed 2017) with latest amendments and ISI mark. including supply of all required materials like lamp holder,Aluminium, batten type, with shade carrier ring,ISI marked, Base: B-22 suitable for use at 250V, Conforming to IS: 1258(Rev.-3)-2005)with amdt-3. With BACK plate of 53 MM. Dia & 45 MM PCD.., ceiling rose, Modular type Socket outlet suitable for 3 pin plug, 6A, 230V, 2 Module, Shuttered (Operation of Shutter should be independant of Earthing Point), Cover made of tough Non-Ignitable insulating material, material of base -vitrified ceramic, Conforming to IS : 1293-2019, Amendment no. 1 or latest with ISI mark ,suitable moduler stainless steel JB box with moduler PVC cover , stainless steel switch Board with moduler PVC cover,PVC Spacers, PVC Saddles,PVC Bends, PVC Tees to be provided as and where required as per direction of consignee,. Provision of moduler fan regulator should be kept on switch board . The plate should include 2 blank space for further installation of switches.including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.Covers or cover parts or parts of them, which are intended to ensure protection against electric shock, shall be held in place at two or more points by effective fixings..The cost includes supply of all materials to complete job. ( Two 5-ampere socket point treated as one point). | — | — | — | 1,57,150 | |
| — | 980.00 | — | — | ||
| "Concealed Sub circuit wiring by 2.5 sq. mm, Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694- 2010(reaffirmed 2020), ISI marked. with 2.5Sq mm earthing wire of Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR- LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694-2010(reaffirmed 2020), ISI marked. through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark with Supply & fixing of PVC Circular Box and Ceiling rose if required with connection from running circuit as per direction of Consignee. including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete the job. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable of size 2.5 sq mm for phase & neutal and 1mtr of 2.5 Sq.mm PVC Cu. cable as earthing with Supply of PVC Circular Box and Ceiling rose as per direction of Consignee. | — | — | — | 1,78,928.4 | |
| — | 400.00 | — | — | ||
| "Concealed Sub circuit wiring by 4 sq. mm, Single Core, Multistrand (56/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked with 4 Sq mm earthing wire of Single Core, Multistrand (56/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete the job. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable of size 4 sq mm for phase & neutal and 1mtr of 4 Sq.mm PVC Cu. cable as earthing. | — | — | — | 88,112 | |
| — | 200.00 | — | — | ||
| "Concealed Sub circuit wiring by 6 sq. mm, Single Core, Multistrand (84/0.3mm), Copper Conductor (flexible), Unsheathed, , Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked with 6 Sq mm earthing wire of Single Core, Multistrand (84/0.3mm), Copper Conductor (flexible), Unsheathed, , Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete the job. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable of size 6 sq mm for phase & neutal and 1mtr of 6 Sq.mm PVC Cu. cable as earthing with Supply of PVC Circular Box and Ceiling rose as per direction of Consignee. | — | — | — | 57,186 | |
| — | 6.00 | — | — | ||
| "Supply of TPN 4-way DB (Double Door) consisting with FP 63A, 10kA MCB with 4PP, Type B- 01 No. as incoming and DP 32A, 10kA MCB with 2PP, Type B- 03 Nos., DP 20A, 10kA MCB with 2PP, Type B- 03 Nos. as outgoing with Cu.bus-bar, Neutral links, Spreader Link and Earth bar etc. Thickness of DB material (in mm): 1.6 mm (CRCA Sheet Steel). Cost includes all other accessories including stainless steel fastener, Pin Type Terminal End Lugs to complete job as per specification attached. | — | — | — | 67,662 | |
| — | 6.00 | — | — | ||
| Fixing and Commisioning of TPN 4-way DB (Double Door) consisting with FP 63A, 10kA MCB with 4PP, Type B- 01 No. as incoming and DP 32A, 10kA MCB with 2PP, Type B- 03 Nos., DP 20A, 10kA MCB with 2PP, Type B- 03 Nos. as outgoing with Cu.bus-bar, Neutral links, Spreader Link and Earth bar etc. and all other accessories including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached with complete wiring to complete job. | — | — | — | 3,451.74 | |
| — | 6.00 | — | — | ||
| "Supply of SPN 8-way DB (Double Door) consisting with DP 40A, 10kA MCB with 2PP, Type B- 01 no. as incoming and SP 10A, 10kA MCB, Type B- 04 nos, SP 16A, 10kA MCB, Type B- 02 nos as outgoing with Cu.bus-bar, Neutral links, Spreader Link and Earth bar etc. Thickness of DB material (in mm): 1.6 mm (CRCA Sheet Steel). Cost includes all other accessories including stainless steel fastener, Pin Type Terminal End Lugs to complete job as per specification attached. | — | — | — | 25,691.76 | |
| — | 6.00 | — | — | ||
| Fixing and Commisioning of SPN 8-way DB (Double Door) consisting with DP 40A, 10kA MCB with 2PP, Type B- 01 no. as incoming and SP 10A, 10kA MCB, Type B- 04 nos, SP 16A, 10kA MCB, Type B- 02 nos as outgoing with Cu.bus-bar, Neutral links, Spreader Link and Earth bar etc. and all other accessories including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached with complete wiring to complete job. | — | — | — | 2,698.38 | |
| — | 6.00 | — | — | ||
| "Supply with testing of Outdoor Type LT Panel made of Powder Coated CRCA Sheet Steel of thickness (minimum): 2mm with Double Door arrangement (Front side openable & operatable compartmental doors and front side outer door is to be provided) to meet Ingress Protection of IP 65 or higher, a canopy at the top made of minimum 2.0mm thick CRCA Sheet Steel to protect panel from rainwater consisting with Two Separate Chambers [Chamber-1 for 3-Ph Local Power Distribution, Chamber-2 for 1-Ph Traction / Emergency Power Distribution]. Chamber-1 consisting of FP 100A, 36kA MCCB- 01 No. as incoming and FP 40A, 10kA MCB with 4PP, Type C- 03 Nos., DP 32A, 10kA MCB with 2PP, Type C- 06 Nos. as outgoing, Chamber-2 consisting of DP 32A, 10kA MCB with 2PP, Type B- 01 No. as incoming and DP 20A, 10kA MCB with 2PP, Type-B- 03 Nos. as outgoing with suitable Cu. Bus bar, Digital Multifunctional Meter in each Incoming & Outgoing MCCB, Capable to measure and display Voltage, Current, Frequency, Power factor, kW, kVAR, kWh, kVAh, kVARh etc., appropriate spreader link for MCCB and with necessary item for seal the cable entry and outgoing point duly conforming PCEE/SER/GRC Specification of LT Distribution Panel as applicable with Description No. SER/ELEC/GS/DESCRIPTION/LT PANEL/1/REV-2/JUNE 2025, Dtd.16/06/2025. | — | — | — | 8,20,203.72 | |
| — | 6.00 | — | — | ||
| Fixing, commissioning and testing of Outdoor Type LT Panel made of Powder Coated CRCA Sheet Steel of thickness (minimum): 2mm with Double Door arrangement (Front side openable & operatable compartmental doors and front side outer door is to be provided) to meet Ingress Protection of IP 65 or higher, a canopy at the top made of minimum 2.0mm thick CRCA Sheet Steel to protect panel from rainwater consisting with Two Separate Chambers [Chamber-1 for 3-Ph Local Power Distribution, Chamber-2 for 1-Ph Traction / Emergency Power Distribution]. Chamber-1 consisting of FP 100A, 36kA MCCB- 01 No. as incoming and FP 40A, 10kA MCB with 4PP, Type C- 03 Nos., DP 32A, 10kA MCB with 2PP, Type C- 06 Nos. as outgoing, Chamber-2 consisting of DP 32A, 10kA MCB with 2PP, Type B- 01 No. as incoming and DP 20A, 10kA MCB with 2PP, Type-B- 03 Nos. as outgoing with suitable Cu. Bus bar, Digital Multifunctional Meter in each Incoming & Outgoing MCCB, Capable to measure and display Voltage, Current, Frequency, Power factor, kW, kVAR, kWh, kVAh, kVARh etc., appropriate spreader link for MCCB and with necessary item for seal the cable entry and outgoing point duly conforming PCEE/SER/GRC Specification of LT Distribution Panel as applicable with Description No. SER/ELEC/GS/DESCRIPTION/LT PANEL/1/REV-2/JUNE 2025, Dtd.16/06/2025 with all other Civil work and accessories to complete job. | — | — | — | 2,44,357.04 | |
| — | 24.00 | — | — | ||
| "Supply, Installation Testing and commissioning of integrated 30 Watt LED & Li-ion battery based Solar Street Light including Pole & accessories. Specification-Solar PV module 150 Watt peak MNRE approved. Warranty 5 years, LED light 4 meter from ground level, Life > 50000 Hrs. & free battery maintenance. | — | — | — | 6,28,704 | |
| — | 18.00 | — | — | ||
| Supply of Cable loop Box(Of fiber body) for 3 phase incoming & outgoing connection consists of 3 phase &neutral terminal &15 A K-fuse as per relevant ISS, with suitable bridge arrangement of size 240mm x 140 mmx 100mm, fitting shall be made with necessary arrangement as per site requirement, cables are to be terminated withproper socking arrangement to complete job. | — | — | — | 17,117.82 | |
| — | 18.00 | — | — | ||
| "Fixing and commissioning of POLYCARBONATE make fire retardent Cable loop box ( of fibre body), IP 66 Fixing shall be made with necessary arrangements as per site requirement, cables are to be terminated with proper socketing arrangement to complete job. | — | — | — | 1,711.8 | |
| — | 18.00 | — | — | ||
| "Supply of Earthing arrangement with supply of Hot Dip Galvanized (HDG) earth cone and all other requisite materials as per CEE/GRC's Drg. No.CEE/G/A3/P-150, Alt.1 including sump box with salt and charcoal, metalic cover etc. as per site supervisor's instruction. Cost includes supply of all materials mentioned in the Drawing including 02 mtrs 25x5mm GI strip for connection from earth electrod pipe to light pole /Rail pole etc. | — | — | — | 78,059.7 | |
| — | 18.00 | — | — | ||
| Erection of Earthing arrangement with erection of Hot Dip Galvanized (HDG) earth cone and all other requisite materials as per CEE/GRC's Drg. No.CEE/G/A3/P-150, Alt.1 including sump box with salt and charcoal, metalic cover etc. as per site supervisor's instruction. Cost includes erection of all materials mentioned in the Drawing including 02 mtrs 25x5mm GI strip for connection from earth electrod pipe to light pole /Rail pole etc. | — | — | — | 18,723.78 | |
| — | 6.00 | — | — | ||
| Supply of 3Phase 4 wire AC energy meter 3PH 10-60 A/20-100A meter+RS232 port as per IS 13779:202 | — | — | — | 47,460 | |
| — | 6.00 | — | — | ||
| Erection of3Phase AC energy meter 3PH 10-60 A/20-100A meter+RS232 port as per IS 13779:202 | — | — | — | 4,746 | |
| — | 4000.00 | — | — | ||
| Laying of cable / cables in under ground along the road through cable trench etc . as per standard drawing including necessary termination , connection and testing.Trenching and laying of U/G cables in any kind of soil trench of size minimum 0.40 mtr wide and 1 mtr deep covered with necessary bricks for protection of the cables including filling of space between brick and cable/cables with sand and refilling the trench with excavated soil, leveling up, and restoring the surface duly rammed. | — | — | — | 5,14,760 | |
| — | 500.00 | — | — | ||
| Laying of cable / cables across the road, track, drain etc through RCC/GI pipe confirming to IS standard of size 100mm or 150mm (or any suitable size as per field requirement based on the actual size of the cable) as per relevant specification and as per standard drawing with necessary termination, connections and testing .Cost also includes collection of cable/cables from Railway store if required.GI pipe will be supplied by contractor. | — | — | — | 1,47,295 | |
| — | 250.00 | — | — | ||
| Laying of cable/ cables on wall / structure through PVC casing pipe of size 4inches or 3inches with accessories or as per site requirement with suitable clamp / saddle/ fixtures etc with necessary termination, connection and testing as per standard drawing.Cost also includes collection of cable/cables from Railway store if required. | — | — | — | 22,125 | |
| — | 500.00 | — | — | ||
| Supply of HDPE pipe of size 110 mm Diameter PE 100 to complete job. | — | — | — | 1,32,500 | |
| — | 500.00 | — | — | ||
| Erection and commissioning of HDPE pipe with all accessories to complete job. | — | — | — | 20,495 | |
| — | 6.00 | — | — | ||
| Supply of Water Cooler Storage Type, Cooling Capacity Rating of Water Cooler (In LPH)- 150. , Storage Capacity for Storage Type Water Coolers (In Liters) -150, Power supply 230 V Single PhaseStorage unit material as per clause no 6.8 of IS 1475 (Part 1) / Storage type unit as per clause no. 5.9 of IS 1475 : 2024 Stainless Steel 304Outer Body Material Stainless Steel 304. | — | — | — | 3,56,994 | |
| — | 6.00 | — | — | ||
| Supply of Automatic change over switches with enclosure(mains 30 Amps, genset/ alternative supply 30 amps) similar to Hager model No: EKS330B. | — | — | — | 16,200 | |
| — | 6.00 | — | — | ||
| Erection of Changeover switches. | — | — | — | 810 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ExplanatorynoteLC.pdf
ATTACHMENT
GCC 2022
ATTACHMENT
allcorrectionslipsmergedupto11compressed.pdf GCC correction slips
ATTACHMENT
MANDATEFORM.pdf
ATTACHMENT
REVISEDFORMATFORCERTIFICATE_1.pdf
ATTACHMENT
LEDSpecificationScan_compressed.pdf
ATTACHMENT
JPOfordiggnigwork.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
allcorrectionslipsmergedupto11compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .