Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC AT PO SURYA NAGAR HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | TALCHER | ANGUL | ODISHA | 759100 | L1 | Accepted-AOC technocommercially eligible L1 bidder | |
| 2 | Rejected-Technical AT PO HANUMANPUR DIST ANGUL ODISHA 759117 | ANUGUL | ODISHA | 759117 | - | Rejected-Technical REJECTED FOR NOT BEING L1 |
Tender Value
₹34.3 L
EMD Value
₹42,900
Closing Date
13 Dec 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer(EnM), Jagannath Area, MCL
Jay Prakash, Staff Officer(EnM), Jagannath Area, MCL PH 06760-269717, 06670-269751(Extn)2023 Fax 06760-269527 E-mail so-enm-jaga.mcl(at)coalindia.in
Day to day maintenance, repair, fault rectification including trimming of trees of All H.T and L.T Overhead Lines under GM Unit, Jagannath Area for a period of 02 Years as and when required basis
2024_MCL_321966_1
GM(JA)/EnM/e-Tender/ 24-25/E-707/72 dtd. 25/11/2024
Open Tender
Electrical and Maintenance Works
Item Rate
730 days
TALCHER
As per NIT
4 documents required · 4 mandatory
₹42,900
14 Mar 2025
25 Nov 2024
16 Dec 2024
26 Nov 2024
13 Dec 2024
26 Nov 2024
26 Nov 2024 - 1 Dec 2024
Amount
H.T OVERHEAD LINE WORKS
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 120 sq. mm
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :120 sq. mm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :120sq.mm
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required .
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required .
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required .
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required .
Supplying and erection of a set of cross bracing frame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height , complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required .
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Supplying and erection of 33 KV Polymer type pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying of 33 KV Polymer disc insulator for 11 KV over head lines with Polymer type insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Supplying of Horizontal type GOAB switch, 11KV 400amps, Double breake 11KVx 3post insulators per phase , Heavy duty copper male & female conctact with double operation rod and separate operation system complete with operating down rod as per reuirement .
Supplying of 11KV , 400amps, 11KVx 3post insulators per phase , DO Fuse set complete as required .
Erection of GOAB switch Horaizontal / Vertical type and 11KV DO Fuse Set complete job as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Manpower for trimming of tree branches laying under 11KV overhead lines of NSCH Feeder ( Total Length of OH Line-5.5 K.Ms ) from 33KV Balanda substation to NSCH Substation compete job as required. For 1 call/day, manpower required: Unskilled: 3 nos.
Supplying and erection of cradle guard complete job as required. 01 set of length of 40 mtrs
Rectification of 11KV Overhead line in faulty condition and restoration the line by supplying of suitable manpower compete job as required. For 1 call/day, manpower required: Electrician (Skilled): 2 nos Electrical Helper (Semi-skilled): 2 nos Unskilled: 1 nos.
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required. (1500mx3wire=4500mtr=4.5KMsx392.14kg/KM)=1764.63 Kgs
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. (0.5x0.5x1x10=2.5Cu.M )
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 13.61.1 Two or more cotes on new works . For 12 Mtrs height pole : 6.24 sq.M x 100nos = 624 sq.M.
Pole Numbering as per degisned from 33KV Balanda Incoming pole to end of the Feeder complete job as required
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
L.T OVERHEAD LINE WORKS
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 8.0 metre and upto 10.0 metre
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required.
Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (100 mm X 110 mm), G.I. bolts, nuts and washers, coach screws etc. as required.
Supplying and erection of 100 mm X 110 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required .
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required.( 500mx5wire=2500mtr=2.5K.Ms x 392.14kgs/K.Ms)=980.35 Kgs
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. (0.5x0.5x1x25=6.5Cu.M )
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 13.61.1 Two or more cotes on new works . For 10 Mtrs height pole : 4.56 sq.M x 100nos = 456 sq.M.
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supplying and fixing of Suspension clamp with I Hook complete set with pole clamp as required.
Supplying and fixing of Dead end clamp with I Hook complete set with pole clamp as required.
Erection of AB Conductor cable of different sizes complete job as required
Transportation of all tubular poles from the stores to the working place with his own arrangement complete job as required.
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
ART ENGINEERING (BID ID -1107248)
techsummary_333748.pdf
PDF • 0.49 MB
finsummary_333748.pdf
PDF • 0.54 MB
LOAE707.pdf
PDF • 5.46 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .