| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-AOC NO 56 PERAMBUR CHENNAI TAMIL NADU 600011 | CHENNAI | TAMIL NADU | 600011 | ₹5.4 L | L1 | Accepted-AOC Lowest bidder. |
| 2 | L2₹7.5 LRejected-Finance NO 121 6 SATHANUR SATHANUR MAIN ROAD SATHANUR BANGALORE KARNATAKA 560064 | BENGALURU URBAN | KARNATAKA | 560064 | ₹7.5 L | L2 | Rejected-Finance Quoted amount is higher than the lowest amount quoted. |
| 3 | L3₹8.0 LRejected-Finance 12 1 TECHSER HOUSE JALAHALLI MES RING ROAD SHARADAMBANAGAR BENGALURU BANGALORE KARNATAKA 560013 UDYAM KR 03 0010269 09AABCT0359D1ZK B 29AABCT0359D1ZI R M 02AABCT0359D2ZX M 05AABCT0359D2ZR B 33AABCT0359D1ZT B 27AABCT0359D1ZM B 36AABCT0359D1ZN B 30AABCT0359D1ZZ B 37AABCT0359D1ZL B 19AABCT0359D1ZJ B 32AABCT0359D1ZV B 10AABCT0359D1Z1 B 07AABCT0359D1ZO B 08AABCT0359D1ZM B 23AABCT0359D1ZU B MII STATUS AS NOT VERIFIED | BENGALURU URBAN | KARNATAKA | 560013 | ₹8.0 L | L3 | Rejected-Finance Quoted amount is higher than the lowest amount quoted. |
| Sl No | Description | Qty | Unit | Soundry Power Systems L1 | Perpetual Power Services Pvt. Ltd. L2 | TECHSER POWER SOLUTIONS PVT LTD L3 |
|---|---|---|---|---|---|---|
| 1.00Cat (A) -Items to be supply and installation | ||||||
| 1.10 | Supply, Installation, Testing, Commissioning and handing over of 12 volts Valve regulated Lead Acid Batteries Sealed Maintenance Free (SMF) of required minimum 100 AH capacity complete with battery cubicle inter ‐ connections, jumper cable and terminal connectors with terminal caps / covers to meet the 2 x 80 KVA UPS systems (I&II) back up requirement. (inclusive of GST). Batteries should be of Panasonic / Rocket / Amararaja make and in Fire retardant container. Location : Main building ground floor UPS (I&II) battery room. | 80 | Nos | 5,150 ₹4.1 L | 9,345.6 ₹7.5 L | 9,558 ₹7.6 L |
| 1.20 | Supply, Installation, Testing, Commissioning and handing over of 12 volts Valve regulated Lead Acid Batteries Sealed Maintenance Free (SMF) of required minimum 65 AH capacity complete with battery cubicle inter ‐ connections, jumper cables and terminal connectors with terminal caps / covers to meet the 2 x 30 KVA UPS systems (I&II) back up requirement. (inclusive of GST)
Batteries should be of Panasonic / Rocket / Amararaja make and in Fire retardant container. Location : Library building Annex 1st floor UPS (I&II) battery room. | 68 | Nos | 7,500 ₹5.1 L | 5,841 ₹4.0 L | 6,372 ₹4.3 L |
| 2.00Cat (B) - Buy Back Items | ||||||
| 2.10 | Buy-Back (ie minus) Rebate for dismantling and taking away old 80 Nos, 100AH SMF Amaron make old batteries installed for 2 x 80 KVA UPS systems (I&II) on as is where is basis. ( Rate for old batteries ) ( inclusive of GST ) | 80 | Nos | 2,006 -₹1,60,480 | 3,186 -₹2,54,880 | 3,186 -₹2,54,880 |
| 2.20 | Buy-Back (ie minus) Rebate for dismantling and taking away old 68 Nos, 65AH SMF Amaron make old batteries installed for 2 x 30 KVA UPS systems (I&II) on as is where is basis. ( Rate for old batteries ) ( inclusive of GST ) | 68 | Nos | 3,186 -₹2,16,648 | 2,124 -₹1,44,432 | 2,124 -₹1,44,432 |
Updated dates
Tender Value
₹11.2 L
EMD Value
₹22,416
Closing Date
11 Nov 2025, 3:00 pmClosed
The Registrar
IMSc, Taramani.
Supply and Installation of new SMF Batteries for Main building Ground floor 2 x 80 KVA UPS systems I and II and the Library building annex 1st floor HPC server room 2x30KVA UPS systems I and II installed at IMSc, Chennai-113.
2025_IMSC_881058_1
IMSc / ELEC - e-TR-02 / 2025
Open Tender
Batteries and cells and accessories
45 days
IMSc, Taramani
Please refer Tender documents
7 documents required · 7 mandatory
₹0
₹22,416
Yes
16 Mar 2026
15 Oct 2025
12 Nov 2025
15 Oct 2025
11 Nov 2025
23 Oct 2025
16 Oct 2025 - 22 Oct 2025
Amount
Cat (A) -Items to be supply and installation
Supply, Installation, Testing, Commissioning and handing over of 12 volts Valve regulated Lead Acid Batteries Sealed Maintenance Free (SMF) of required minimum 100 AH capacity complete with battery cubicle inter ‐ connections, jumper cable and terminal connectors with terminal caps / covers to meet the 2 x 80 KVA UPS systems (I&II) back up requirement. (inclusive of GST). Batteries should be of Panasonic / Rocket / Amararaja make and in Fire retardant container. Location : Main building ground floor UPS (I&II) battery room.
Supply, Installation, Testing, Commissioning and handing over of 12 volts Valve regulated Lead Acid Batteries Sealed Maintenance Free (SMF) of required minimum 65 AH capacity complete with battery cubicle inter ‐ connections, jumper cables and terminal connectors with terminal caps / covers to meet the 2 x 30 KVA UPS systems (I&II) back up requirement. (inclusive of GST) Batteries should be of Panasonic / Rocket / Amararaja make and in Fire retardant container. Location : Library building Annex 1st floor UPS (I&II) battery room.
Cat (B) - Buy Back Items
Buy-Back (ie minus) Rebate for dismantling and taking away old 80 Nos, 100AH SMF Amaron make old batteries installed for 2 x 80 KVA UPS systems (I&II) on as is where is basis. ( Rate for old batteries ) ( inclusive of GST )
Buy-Back (ie minus) Rebate for dismantling and taking away old 68 Nos, 65AH SMF Amaron make old batteries installed for 2 x 30 KVA UPS systems (I&II) on as is where is basis. ( Rate for old batteries ) ( inclusive of GST )
Perpetual Power Services Pvt. Ltd. (BID ID -3308637)
TECHSER POWER SOLUTIONS PVT LTD (BID ID -3313331)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx