Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57.0 LAccepted-Finance | L1 | Accepted-Finance OK | |
| 2 | L2₹69.4 L+₹12.4 L (21.8%)Accepted-Finance | L2 | Accepted-Finance OK | |
| 3 | L3₹81.8 L+₹24.8 L (43.5%)Accepted-Finance | L3 | Accepted-Finance OK |
| Sl No | Description | Qty | Unit | M/S Sengar Enterprises L1 | shiva engineering AND suppliers L3 | M/s Jaswantpur Filling Station L2 |
|---|---|---|---|---|---|---|
| 1.00Carriage following material from Centre Stores, Mainpuri to site of work (Distance 00-20 Kms.) through the Kacha and Pakka road including the work of its loading and unloading at the respective ends as per RESPO manual and as per direction of Concern Executive Engineer including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work in the area of Concern Division under EDC MAINPURI, (Material shall be provieded by Department) | ||||||
| 1.01 | 9 M STP Pole-SP- 55 Galvanised | 16 | No | 849.6 ₹13,593.6 Lowest | 885 ₹14,160 | 944 ₹15,104 |
| 1.02 | 11 M STP Pole-SP- 55 Galvanised | 170 | No | 1,038.4 ₹1,76,528 | 1,003 ₹1,70,510 | 944 ₹1,60,480 Lowest |
| 1.03 | 13 M STP Pole-SP- 70 Galvanised | 18 | No | 2,076.8 ₹37,382.4 | 1,062 ₹19,116 | 944 ₹16,992 Lowest |
| 1.04 | 8.5 M PCC Pole | 8 | No | 259.6 ₹2,076.8 Lowest | 1,062 ₹8,496 | 944 ₹7,552 |
| 1.05 | V Type Cross Arm for 11 KV | 168 | No | 65.14 ₹10,943.52 | 35.4 ₹5,947.2 Lowest | 35.4 ₹5,947.2 Lowest |
| 1.06 | 11 KV Pin Insulator with Pin | 555 | No | 6.61 ₹3,668.55 Lowest | 35.4 ₹19,647 | 35.4 ₹19,647 |
| 1.07 | Disc Insulator with Fitting | 282 | No | 9.44 ₹2,662.08 Lowest | 35.4 ₹9,982.8 | 35.4 ₹9,982.8 |
| 1.08 | LT XLPE Cable Size 3.5x400 Sq.mm. | 60 | Mtr | 75.52 ₹4,531.2 | 35.4 ₹2,124 Lowest | 35.4 ₹2,124 Lowest |
| 1.09 | LT XLPE 3.5x70 Sq.mm. | 390 | Mtr | 28.32 ₹11,044.8 | 23.6 ₹9,204 Lowest | 23.6 ₹9,204 Lowest |
Tender Value
₹42 L
EMD Value
₹42,000
Closing Date
25 Sept 2025, 12:00 pmClosed
SE EDC MAINPURI
POWER HOUSE CAMPUS MAINPURI
Electrical work Approved in Business Plan Year 2025 26 on Semi Turnkey basis Under Electricity Urban Distribution Division Mainpuri
2025_DVVNL_1070256_1
EDC(M)-12/2025-26
Open Tender
Electrical Works
Lump-sum
180 days
DISTRICT MAINPURI
AS PER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹3,000
DVVNL
₹42,000
29 Sept 2025
31 Aug 2025
25 Sept 2025
31 Aug 2025
25 Sept 2025
31 Aug 2025
Amount
Carriage following material from Centre Stores, Mainpuri to site of work (Distance 00-20 Kms.) through the Kacha and Pakka road including the work of its loading and unloading at the respective ends as per RESPO manual and as per direction of Concern Executive Engineer including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work in the area of Concern Division under EDC MAINPURI, (Material shall be provieded by Department)
9 M STP Pole-SP- 55 Galvanised
11 M STP Pole-SP- 55 Galvanised
13 M STP Pole-SP- 70 Galvanised
8.5 M PCC Pole
V Type Cross Arm for 11 KV
11 KV Pin Insulator with Pin
Disc Insulator with Fitting
LT XLPE Cable Size 3.5x400 Sq.mm.
LT XLPE 3.5x70 Sq.mm.
3x120 Sq.mm. AB Cable
AL. XLPE Cable Size 1 x 400 Sq.mm.
AL. XLPE Size 1 x 240 Sq.mm.
Three Phase Distribution Box
11 KV TPMO with Polymer Insulator
Complete Stay 9GI Stay Rod 20x1800 mm, stay wire 7/8 SWG, 10 KG, Stay Clamp, Bolt, nut and washer)
Distribution Transformer 25 KVA
Distribution Transformer 100 KVA
Distribution Transformer 250 KVA
ACSR Rabit Conductor
ACSR weasel Conductor
DO Fuse Set
Earthing Complete
11 KV VCB
33 KV Lightning Arrester
33 KV CT Set
33 KV PT Set
33 KV Control Panel
Battery Charger DC
Battery 24 Volt DC
1x120 Sq.mm. L.T, XLPE Cable For D.B. Energization
Supply of the Following Material.
Clamp For 11 KV "V" type cross arm with bolts and nuts
F-bracket for STP with Clamp, Nut and Bolts
L.T. Fuse Set Protection Box
Stone Pad (300x300x75)
Holding Clamp for Doulble Pole Unit with Nut and Bolts
Danger Board With Clamp and Nut & Bolt
PG Clamp for Conductor
Chemical Earthing as per Norms
Dropper Channel 100x50x2028 mm.
MS Angle 75x75x6x2028mm with clamp & Bolt and nut (T/F base)
T-Off Chhanel+ T/F Clamp
Top Chhanel 125x65x240
WTI/OTI as per Norm and Requirements
L.T. Tail Less unit
Suspension Clamp
Dead End Clamp
Eye (I) Hook
AL. Lug 240 Sq.mm.
LT PVC Armoured Cable size 4 x 25 Sq.mm.
4 Core LT MCB with Box for 250 KVA T/F
Copper L-Pieace 62x225x12mm.
Pearcing Connector for D.B.
Three Phase Distribution Box Clamp with Nut & Bolts
Only Erection of the following Material
Clamp For 11 KV "V" type cross arm with bolts and nuts
F-bracket for STP with Clamp, Nut and Bolts
L.T. Fuse Set Protection Box
Stone Pad (300x300x75)
Holding Clamp for Doulble Pole Unit with Nut and Bolts
Danger Board With Clamp and Nut & Bolt
PG Clamp for Conductor
Chemical Earthing as per Norms
Dropper Channel
MS Angle 75x75x6x2028mm with clamp & Bolt and nut (T/F base)
T-Off Chhanel+ T/F Clamp
Top Chhanel 125x65x240
WTI/OTI as per Norm and Requirements
L.T. Tail Less unit
Suspension Clamp
Dead End Clamp
Eye (I) Hook
AL. Lug 240 Sq.mm.
LT PVC Armoured Cable
4 Core LT MCB with Box for 250 KVA T/F
Copper L-Pieace 62x225x12mm.
Pearcing Connector for D.B.
Three Phase Distribution Box Clamp with Nut & Bolts
Laying, stringing, sagging, binding and jumpering etc of following conductor on the erected supports, as per RESPO norms.
ACSR Rabit Conductor
ACSR weasel Conductor
Dismantle of all old existing assesories where as it is required & carriage to centre store Mainpuri 0-15 Km
Erection of Double pole structure 8.5 Mtr PCC Pole by digging of pits fitting of all relevant accessories with 25 KVA as per RESPO norms.
Erection of Double pole structure 9/11/13 Mtr STP Pole by digging of pits fitting of all relevant accessories as per RESPO norms.
Erection of single pole structure 9/11/13 Mtrs on ST Pole by digging of pits fitting of all relevant accessories as per RESPO norms.
Grouting of PCC/STP POLE Long As per Respo Norms (Cement, Sand, Blast Stone with the ratio 1:4:8) will be provided by conractor
Earthing of pole by M S Earthing Rod 20 x2500 mm and 6 SWG earthing wire etc
Pipe Earthing of Power T/F by GI strip patti as per RESPO manual and as per direction of executive engineer including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.
Construction of Distribution Transformer plinth of size 2x2x1.5 Mtr at various places under the jurisdiction of Concern Division, Mainpuri. The size of plinth shall be of 4’ above the ground level. At the bottom there shall be brick ballast pad of size 5x6’x3” thick in ratio 1:3:6 [Cement, sand and brick ballast]. The first class brick wall work shall be 9” thick in ratio 1:4 [Cement and sand]. The hollow portion among the wall shall be filled up with the brick ballast properly hammered and rammered as per direction of Executive engineer. On the top of the wall there shall be mesh of 12 mm thick iron rod at distance of 9’’ and RCC work in ratio 1:3:6 [Cement, Sand and grit stone] There shall be plastering all over the plinth 12 mm thick in ratio 1:4 [Cement and sand] above the ground level. Proper watering and curing of the plinth shall be carried out as per direction of Executive engineer., and also including the cost of arrangement of labourer, T&P etc required for proper completion of work.
Fencing of Distribution Transformers with Enamel in proper alignment as per RESPO manual and as per direction of Executive engineer including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.
Installation of the Following new transformers at various 11/0.4 KV substation, under the jurisdiction of Concern Distribution Division, Mainpuri, in proper alignment and direction and making proper HT/LT connection as per instruction of Executive Engineer after carriage the same from Centre Stores,Mainpuri including the work of safe loading and unloading at the respective ends and also including the cost of arrangement of laborer, T&P, carrier etc required for proper completion of work.
11/0.4 KV T/F 250 KVA with L.T. XLPE Cable Suitable Size with all respective material as per Norms.
11/0.4 KV T/F 100 KVA with L.T. XLPE Cable Suitable Size with all respective material as per Norms.
Laying of Following Cable
Cable LT ABC (3x120+1x95+1x16) sq mm
Installation Of Three Phase Distribution Box with all respective material as per Norms.
Installation Of 11 KV VCB and Make Proper Connection As per Norms.
Installation Of 33 KV Lighting Arrestor Make Proper Connection As per Norms. at 33 KV Substation Under EUDD MAINPURI.
Installation Of 33 KV CT Set and Make Proper Connection As per Norms.
Installation Of 33 KV PT Set and Make Proper Connection As per Norms.
Installation Of 33 KV Control Pannel and Make Proper Connection As per Norms.
Installation Of Battery Charger DC and Make Proper Connection As per Norms.
Installation Of 24 Battery DC and Make Proper Connection As per Norms.
M/s Jaswantpur Filling Station (BID ID -5547226)
shiva engineering AND suppliers (BID ID -5547204)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .