| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC | ₹40.0 L Quoted ₹40.8 L | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹41.6 L+₹76,306 (1.87%)Rejected-Finance | ₹41.6 L+₹76,306 (1.87%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹43.2 L+₹2.4 L (5.83%)Rejected-Finance | ₹43.2 L+₹2.4 L (5.83%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹46.5 L+₹5.7 L (13.9%)Rejected-Finance | ₹46.5 L+₹5.7 L (13.9%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹46.5 L+₹5.7 L (14.0%)Rejected-Finance 27 WESTERN STREET ROOM NO 307 KOLKATA 700012 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700012 | ₹46.5 L+₹5.7 L (14.0%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
7 Feb 2022, 6:00 pmClosed
GE I R and D Chandipur
GE I R and D Chandipur, Post- Chandipur, PIN-756025
REPAIR REPLACEMENT OF POINT WIRING REPLACEMENT OF ELECT FITTING AND FIXTURES AND EARTHING OF MD ACCN TECH ACCN AND REPAIR TO DOMESTIC SUMMER APPLIANCES AND VOLTAGE STABLIZERS AT PXE CHANDIPUR
2021_MES_487030_3
8681/CDP
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chandipur
As per tender documents
7 documents required · 7 mandatory
₹500
GE I R and D Chandipur
₹88,000
Yes
12 Mar 2022
24 Jan 2022
9 Feb 2022
24 Jan 2022
7 Feb 2022
2 Feb 2022
Amount
NOTE (Applicable for all items) :- The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A' PART-I (INTERNAL ELECTRIFICATION)
Taking down carefully copper/aluminum point wiring (Light fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators socket, light fittings etc removing materials for taking credit and making good disturbed surfaces of wall, floor, etc.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick of size not less than 200 mm x 300 mm and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan controlled by one 5/6 amps, one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick of size not less than 200 mm x 300 mm and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 5/6 amps switch socket combination on independent board including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick of size not less than 200 mm x 300 mm and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for for one 5/6 amps socket outlet on same board controlled with other switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 2.5 Sqmm (phase & neutral) and one run of 2.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (heavy duty) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 15/16 amps socket outlet on independent board controlled with one, 15/16 amps one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (medium grade) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan point controlled by one 5/6 amps, one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (heavy duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 5/6 amps socket outlet on independent board controlled with one, oneway switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 4 Sqmm (phase & neutral) and one run of 2.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (heavy duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 6/16 amps socket outlet on independent board controlled with one, 16 amps one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
All as per Sl Item No. 1.02 here-in-before but drawn in through existing concealed conduit.
All as per Sl Item No. 1.03 here-in-before but drawn in through existing concealed conduit.
All as per Sl Item No. 1.04 here-in-before but drawn in through existing concealed conduit.
All as per Sl Item No. 1.05 here-in-before but drawn in through existing concealed conduit.
S & F Including connection of switch piano, flush button, type single pole one way 5 Amps,
S & F Including connection of switch socket combination 5 Amps 2 in 1 flush type,
S & F Including connection of switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type
S & F ceiling rose, polycarbonate three terminals.
S & F Electronic fan regulator, stepped type 120/280V complete all as directed by Engineer-in-Charge.
Supply and fixing including connection of modular switch one way 6 Amps 1 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
Supply and fixing including connection of modular switch one way 16 Amps 1 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
Supply and fixing modular Bell push 6A 1 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
Supply & fixing including connection modular Switch socket combination 2 in 1,5 pin 5 amps 3 modules complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
Supply & fixing including connection modular Switch socket combination 2 in 1,6 pin 16 amps 3 modules complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
Supply & fixing including connection modular socket outlet 2 /3 pin 6 Amps 2 modules complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
Supply & fixing including connection modular socket outlet 2 /3 pin 6/16 Amps 2 modules complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
Supply and fixing of Modular Fan regulator, 120 watts (Make : .Crabtree/Cona/Havells)
Supply and fixing white modular cover plate with frame 1 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
Supply and fixing white modular cover plate with frame 2 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
Supply and fixing white modular cover plate with frame 3 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
Supply and fixing white modular cover plate with frame 4 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
Supply and fixing white modular cover plate with frame 6 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
Supply and fixing white modular cover plate with frame 8 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells)
Supply and fixing modular metal flush box 1/2 Module complete all as specified and directed.
Supply and fixing modular metal flush box 3 Module complete all as specified and directed.
Supply and fixing modular metal flush box 4 Module complete all as specified and directed.
Supply and fixing modular metal flush box 6 Module complete all as specified and directed.
Taking down Sub main /Sub circuit wiring of any type and size including conduit / casing capping / batten wiring complete all as directed by Engineer-in-Charge.
M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 4 Sqmm to be drawn in and including PVC conduit 25 mm dia (medium grade). Note: Three runs of 4 Sqmm copper wire and one run of PVC conduit shall be measured as one unit.
M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 6 Sqmm to be drawn in and including PVC conduit 25 mm dia (medium grade). Note: Three runs of 6 Sqmm copper wire and one run of PVC conduit shall be measured as one unit.
M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 2.50 Sqmm to be drawn in and including PVC conduit 20 mm dia (medium grade). Note: Three runs of 2.50 Sqmm copper wire and one run of PVC conduit shall be measured as one unit.
M&L Submain wiring using six runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 6 Sqmm to be drawn in and including PVC conduit 25 mm dia (medium grade). Note: Six runs of 6 Sqmm copper wire and one run of PVC conduit shall be measured as one unit.
Supply and fix in repair vertical TPN MCBDB 8 way with 200 Amps rated busbar, double door type including provision for fixing MCCB 4 pole 100 Amps, 25 KA complete including taking down old DB and making disturbed surafce good to match the existing surface Make Make : L&T cat part No. DBVTLOO8DD or equivalent in Havells/ Legrand
S & F in repair MCB DB made of sheet steel phosphatised powder coated with bus bar, neutral link, earth bar and din rail, double door type, TPN 4 way 240v, fixed in wall including making good disturbed surfaces including taking down old unserviceable , complete all as directed by Engineer-in-Charge. Make : L&T cat part No. DBVTLOO4DD or equivalent in Havells/ Legrand
All as per Sl Item No 1.42 here-in-before but of SPN 8 way,240Volts double door as in repair. Make - L&T cat part No. DBSPNOO8DD or equivalent in Havells/ Legrand
All as per Sl Item No 1.42 here-in-before but of SPN 12 way,240Volts double door as in repair. Make - L&T cat part No. DBSPNO12DD or equivalent in Havells/ Legrand
S & F in repair MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 36 kA, 415 Volts, 100 Amps including taking down old unserviceable one. Make : Make - L&T cat part No. CM97919OOK2OG or equivalent in Havells/ Legrand
All as per Sl Item No 1.45 above but of capacity 63 Amps, 4 Pole, 18 KA. Make - L&T cat part No. CM90518OOJO or equivalent in Havells/ Legrand
S & F in repair MCB, SPN. 6-32 Amps rating 240, volt, 'C' series, 10 kA, Make : Havells/Legrand/L&T
S & F in repair , MCB, TPN, 240V, 50Hz, 10kA, 'C' series, 63 Amps series. Make : Havells/Legrand/L&T
S & F in repair , MCB, TP, 240V, 50Hz, 10kA, 'C' series, 6 to32 Amps series. Make : Havells/Legrand/L&T
S & F in repair MCB, SP, 6 to 32 Amps, 240 volt, 'B' Series, 10 kA, as in repairs.Make :Havells/Legrand/L&T
Supply and fix in repair LED battern pre wired suitable to use with LED tube, complete with powder coated decorative LED batten box type complete,including with PVC insulated flexible copper wire of size .5 sqmm 2 core from ceiling rose to fitting complete incl taking down old fitting all as specified and directed Make : SURYA Batten Cat part No SUB 118 T8 LED 1 X18 WATT or equivalent model of make list as given in Appdix "A".
All as per item as above here-in-before but enviroment friendly energy saving, T8 LED tub with aluminium extrucsion heat sink for optimum performance with high luminous efficacy and easy . Make : SURYA 18 PAL EXT or equivalent model of make list as given in Appdix "A".
Suplly and fix in repair recessed/surface mounted LED luminaire suitable for armstron/grid ceiling with its super bright LED 20 Watt is a delight in modern office environment this panel gives a soft soothing light additional mounting frame required for gypsum/pop ceiling installation deemed at this rate 1'x1', 20 W all as spd and directed by engrs in charge. Make : SURYA Celesta Cat Part No SLE DS 20 11S 20 Watt or equivalent model of make list as given in Appdix "A".
Suplly and fix in repair recessed/surface mounted LED luminaire suitable for armstron/grid ceiling with its super bright LED 36 Watt is a delight in modern office environment this panel gives a soft soothing light additional mounting frame required for gypsum/pop ceiling installation deemed at this rate 2'x2', 36 W all as spd and directed by engrs in charge Make SURYA Celesta Cat part No. SLE DS 36 22R or equivalent model of make list as given in Appdix "A".
Supply and fix in repair LED T8 40 watt Batten for multipurpose application made from extruded aluminium housing and polycorbonate diffuser 40 watt with aluminiu housing complete all as specified including cutting and making space of suitable size on existing ceiling of any type complete all as directed Make : SURY Maple Cat Part No. SLE BTN T8 40 or equivalent model of make list as given in Appdix "A".
S & F in repair Sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP of 20 Amps . Make : L&T/Schnieder/Siemens
M&L Earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm buried directly in ground connected to galvanized earth lead strip of size 25 mm x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron including 40mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe light grade 20mm dia, charcoal or coke and common salt in alternative layers of 15 cm compacted thickness all around the electrode with concrete earth pit with PCC type C1 , 1:3:6 (using 20 mm graded stone aggregate), 50mm thick precast RCC type B1, (1:2:4)(using 20 mm graded stone aggregate) pit cover reinforced with 8mm dia deformed bar and suitable handle made of 10mm dia round bar including galvanised strip of size 25mm x 4mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No.3 of SSR Part-I, 2009 and all as directed including taking down old unserviceable one. (Note : GI strip upto 7.5 m length shall be deemed to include in the cost of above item.
S & F in repair Earthing conductor with GI strip of size (25 x 4) mm complete all as directed by Engineer-in-Charge.
Fixing only in repair Earthing conductor with GI strip of size (25 x 4) mm mounted on insulator fixed with wall and surface complete all as directed by Engineer-in-Charge.(Note :- Rate of Insulator fastners dirlling deemed at this rate)
Disconnecting electrically and dismantling of ceiling fans of any make capacity and type, washing thoroughly of bearing /bush, fan blades and body of fan by kerosene /petrol etc and greasing for smooth functioning. Replacement of worn out/defective unserviceable parts (where ever necessary), reassembling the same including provision of three core flexible copper wire as per requirement (minimum 1.5m long), including one coat of synthetic enamel paint (first quality) with super glossy finish to fan body and blades refixing the same to its original position including testing complete all as directed by Engineer-in-Charge. (NOTE : Replacement of worn out/ defective/unserviceable parts and rewinding shall be measured and paid separately under relevant items of these schedule).
All as per Sl Item No 1.60 here-in-before but for Exhaust fans of any size and make.
All as per Sl Item No 1.60 here-in-before but for air circulator fans/wall mounting fans of any size and make.
M&L Rewinding the motor of AC ceiling fan of any make and size (1200/1400mm) with super enamelled copper wire of adequate size/gauge including all insulation materials, varnishing etc complete all as directed by Engineer-in-Charge.
All as per Sl Item No 1.63 here-in-before but for exhaust fans of 300/380mm sweep of any make.
All as per Sl Item No 1.63 here-in-before but for air circulators/wall mounting fans of any make and size.
Supply only Ball bearing of suitable size for any type/make of ceiling fan, Make : TATA/NBC/SKF.
All as per Sl Item No 1.66 here-in-before but for Exhaust fans of any type/size/make.
All as per Sl Item No 1.66 here-in-before but for air circulators/ wall mounting fans of any type/size/make.
Supply only capacitor 220 volts, 2.5 mfd suitable for ceiling fan, Make : SARADA/ TIBCON/ UNIVERSAL.
Supply only capacitor 220 volts,4 mfd suitable for ceiling fan, Make : SARADA/ TIBCON/ UNIVERSAL.
S & F in repair Hanging clamp for ceiling fan of adequate size including rubber reel, nuts, bolts and washers etc complete including taking down old unserviceable one, all as directed by Engineer-in-Charge.
S&F in repair LED Bldg security light fitting 25 Watt with all accessories, (with extra driver) attractively styled high pressure die cast housing acting as a heat sink housing epoxy powder coated in dark graphite grey colour suitable for mounting bracket of 40mm bore GI pipe light grade complete with all accessories including taking down old fitting as directed. Make - SURYA Lexon Cat Part No SLE UL 25W IP66 (LXN) or or equivalent model of make list as given in Appdix "A".
Taking down geysers of capacity 25 liters and carrying to workshop for repairing, servicing, cleaning etc, replacement of thermostat, heating element, indicator lamp and thermal cut out incl fixing of PVC cable, sheathed, three core with stranded copper conductor of size 2.5 sqmm and refixing the geysers at location as directed. (Note:- Heating element, thermostat indicator lamp & thermal cutout etc shall be measured and paid separately as supply only)
Taking down geysers of capacity 50 liters and carrying to workshop for repairing, servicing, cleaning etc, replacement of thermostat, heating element, indicator lamp and thermal cut out incl fixing of PVC cable, sheathed, three core with stranded copper conductor of size 2.5 sqmm and refixing the geysers at location as directed. (Note:- Heating element, thermostat indicator lamp & thermal cutout etc shall be measured and paid separately as supply only)
Supply only heating element 1.5 KW, 230 volt round/ triangular in shape ISI marked complete
Supply only thermostat ISI marked complete suitable for 25/50 liters capacity geyser
Supply only Indicating lamp (red/green/yellow) complete suitable for 25/50/100 liters capacity geyser
Supply and fixing for LT ACB of capacity 800 Amps 1000 Volts by all connected works including require at site for proper and smooth functing of air circuit breaker all as specified and as directed. Make : SIEMENS Cat Part WLI 800 N, No 491240204107 or equivalent model of make list given in Appendix A.
SCHEDULE 'A' PART-II (SUMMER APPLIANCES AND VOLTAGE STABLIZERS)
Taking out unserviceable Receprocating type compressor of the Window /Split Type AC 1.5 Ton capacity, from site and replacement of compressor with new one to match with existing make/ Model (R Compressor) and fixing of new compressor sealed unit in position, charging required quantity of refrigerant gas R-22/R-134a/R-410 as per existing design of AC, brazing of discharge and suction line including leak testing complete as directed by the Engineer-in-charge Make :- Kirlosker / Hitachi / Hillie / Copeland / Danfoss. Note: Cost of copper capilary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost.
Taking out unserviceable Receprocating type compressor of the Window /Split Type AC 2 Ton capacity, from site and replacement of compressor with new one to match with existing make/ Model (R Compressor) and fixing of new compressor sealed unit in position, charging required quantity of refrigerant gas R-22/R-134a/R-410 as per existing design of AC, brazing of discharge and suction line including leak testing complete as directed by the Engineer-in-charge Make :- Kirlosker / Hitachi / Hillie / Copeland / Danfoss. Note: Cost of copper capilary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost.
Taking out unserviceable Rotary type compressor of Window/ Split Type AC 1.5 Ton capacity, from site and replacement of compressor with new one to match with existing make/Model (R Compressor) and fixing of new compressor sealed unit in position, charging required quantity of refrigerant gas R-22/R-134a/R-410 as per existing design of AC, brazing of discharge and suction line including leak testing complete as directed by the Engineer-in-charge Make :- Kirlosker / Hitachi / Hillie / Copeland / Danfoss. Note: Cost of copper capilary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost.
Taking out unserviceable Rotary type compressor of Window/ Split Type AC 2 Ton capacity, from site and replacement of compressor with new one to match with existing make/Model (R Compressor) and fixing of new compressor sealed unit in position, charging required quantity of refrigerant gas R-22/R-134a/R-410 as per existing design of AC, brazing of discharge and suction line including leak testing complete as directed by the Engineer-in-charge Make :- Kirlosker / Hitachi / Hillie / Copeland / Danfoss. Note: Cost of copper capilary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost.
M/L for Gas charging with R-22 refrigerant gas for Split / Windows ACs of any make, model and capacity, Refrigerator and Water coolers of any make, Model of any capacity in position or by taking down including leak testing to achieve desired suction pressure and temperature and all as directed by Engg-in-Charge. Note: Leakage or loss of gas due to imperfect workmanship will not be measured. Only the qty of gas utilised as per design of machine will be measured after successful gas charging.
M/L for Gas charging with R-410/R-134A refrigerant gas for Split / Windows ACs of any make, model and capacity, Refrigerator and Water coolers of any make, Model of any capacity in position or by taking down including leak testing to achieve desired suction pressure and temperature and all as directed by Engg-in-Charge. Note: Leakage or loss of gas due to imperfect workmanship will not be measured. Only the qty of gas utilised as per design of machine will be measured after successful gas charging.
Cleaning, servicing including carrying out preventive maintenance of summer appliances viz. indoor and outdoor unit of Split AC 2.0 TR Capacity using suitable cleaning solution, chemicals, tools and minor spares viz. screws, washers, insulation tapes, thimbles, PVC fasteners etc. as per site requirement and as directed. Cleaning of the condensor, evaporator, fins and cooling coils shall be done using Blower / Vacuum cleaner, cleaning clothes, nylon brushes etc till scales and dirts are removed including cleaning of drain pipe line and replacement of unserviceable spares if any and ensuring its serviceability by keeping the AC in good working condition all as specified and directed by Engineer-in-Charge. Note :- 1. During servicing work, if any major fault is observed, the machine will be repaired under respective item of the schedule under Supply and fix in repair work, and thereafter servicing will be undertaken and completed. 2. Spares required for repair of unserviceable machines if any will be measured and paid under respective item of this schedule as "Supplied only" items. However, for servicing work, cost of minor spares to be replaced if any and not specified in this schedule viz. screws, washers, teflon seal, rubber bush, insulation tape, copper thimble, copper connecting jack, short length connecting wire, markers etc upto Rs 100 is deem to be included in the rate of the item. 3. Cost of taking down, reinstallation and transportation if required for the servicing / repair work is deem to be included in the price. 4. Servicing and repair work will be carried out within the contract period as and when required as per the site requirement and as directed by Engg-in-Charge.
Cleaning, servicing including carrying out preventive maintenance of summer appliances viz. indoor and out door unit of Split AC 1.5 TR Capacity using suitable cleaning solution, chemicals, tools and minor spares viz. screws, washers, insulation tapes, thimbles, PVC fasteners etc. as per site requirement and as directed. Cleaning of the condensor, evaporator, fins and cooling coils shall be done using Blower / Vacuum cleaner, cleaning clothes, nylon brushes etc till scales and dirts are removed including cleaning of drain pipe line and replacement of unserviceable spares if any and ensuring its serviceability by keeping the AC in good working condition all as specified and directed by Engineer-in-Charge. Note :- 1. During servicing work, if any major fault is observed, the machine will be repaired under respective item of the schedule under Supply and fix in repair work, and thereafter servicing will be undertaken and completed. 2. Spares required for repair of unserviceable machines if any will be measured and paid under respective item of this schedule as "Supplied only" items. However, for servicing work, cost of minor spares to be replaced if any and not specified in this schedule viz. screws, washers, teflon seal, rubber bush, insulation tape, copper thimble, copper connecting jack, short length connecting wire, markers etc upto Rs 100 is deem to be included in the rate of the item. 3. Cost of taking down, reinstallation and transportation if required for the servicing / repair work is deem to be included in the price. 4. Servicing and repair work will be carried out within the contract period as and when required as per the site requirement and as directed by Engg-in-Charge.
Cleaning, servicing including carrying out preventive maintenance of summer appliances viz. unit of Window type AC 1/1.5/2 TR Capacity using suitable cleaning solution, chemicals, tools and minor spares viz. screws, washers, insulation tapes, thimbles, PVC fasteners etc. as per site requirement and as directed. Cleaning of the condensor, evaporator, fins and cooling coils shall be done using Blower / Vacuum cleaner, cleaning clothes, nylon brushes etc till scales and dirts are removed including cleaning of drain pipe line and replacement of unserviceable spares if any and ensuring its serviceability by keeping the AC in good working condition all as specified and directed by Engineer-in-Charge. Note :- 1. During servicing work, if any major fault is observed, the machine will be repaired under respective item of the schedule under Supply and fix in repair work, and thereafter servicing will be undertaken and completed. 2. Spares required for repair of unserviceable machines if any will be measured and paid under respective item of this schedule as "Supplied only" items. However, for servicing work, cost of minor spares to be replaced if any and not specified in this schedule viz. screws, washers, teflon seal, rubber bush, insulation tape, copper thimble, copper connecting jack, short length connecting wire, markers etc upto Rs 100 is deem to be included in the rate of the item. 3. Cost of taking down, reinstallation and transportation if required for the servicing / repair work is deem to be included in the price. 4. Servicing and repair work will be carried out within the contract period as and when required as per the site requirement and as directed by Engg-in-Charge.
All as per Sl Item No. 2.07 above but for water cooler of any type, any size and any capacity. The inner water tank of water cooler should be cleaned using bleaching powder and keeping the inner tank clean from bacteria and formation of scales and ensuring its serviceability all as specified and as directed by Engineer-in-Charge.
All as per Sl Item No. 2.07 above but for Refrigerator / Deep freezer of any capacity, make and model . The inner tank of refrigrator / deep freezer should be cleaned using bleaching powder and keeping the inner tank clean from bacteria and formation of scales and ensuring its serviceability all as specified and as directed by Engineer-in-Charge.
Supply only thermostat for water cooler / refrigerator / deep freezer of any capacity and make.
Supply only relay for any type of water cooler /refrigerator/deep freezer of any capacity & make.
Supply only PCB suitable for split type A/C 1.5 TR capacity of any make/ model
Supply only PCB suitable for split type A/C 2 TR of any make.
Supply only Digital Display Unit suitable for split / window type A/C 1.5/ 2 TR of any make and model.
Supply only Air sensor suitable for split / window type A/C 1.5/2.0 TR of any make/ model
Supply only Coil sensor suitable for window / split type A/C1.5/ 2 TR of any make/ model
Supply only Running capacitor 45+5 mfd for Window / Split type Air conditioner of of any capacity.
Supply only Running Capacitor capacitor 50+5 mfd for Air conditioner 2 Ton Capacity
Supply only Capacitor of 2.50 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model .
Supply only capacitor of 4.0 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model .
Supply only capacitor of 6.0 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model.
Supply only auto swing motor for indoor unit of split A/C of capacity 2/1.5 TR of any make and model to match with existing design conditions.
Supply only Brass angle valve of size 5/8 inch for split AC 1.5/2TR capacity.
Supply only Brass angle valve 1/4 inch for split AC 1.5/2TR capacity.
Supply only Nitrile Foam Insulation for copper tube of size 5/8 inch suitable for split AC including provision of requisite PVC fasteners.
Supply only Nitrile Foam Insulation for copper tube of size 3/8 inch suitable for split AC including provision of requisite PVC fasteners..
Supply only Nitrile Foam Insulation for copper tube of size 1/2 inch suitable for split AC including provision of requisite PVC fasteners..
Supply only PVC ball valves / float valve for water cooler of any capacity & make
Supply only Thermostat for Window AC of capacity 1.5 TR/2.0 TR to match with existing design conditions.
Supply only relay of model suitable for Window type AC of any capacity and to match with existing design conditions..
Supply only Remote Universal type suitable for all type of split / window AC of any make and model or any capacity and to match with existing design conditions..
Supply only PVC Drain pipe of size 1/2" size suitable for Split type AC of any capacity.
Supply only , main Drain pipe of indoor unit of size 3/4 ", PVC Flexible type suitable for Split type AC of any capacity.
Supply only Rubber Bush for Fan Motor of out door unit of split type AC and Window type AC of any capacity and any make and model .
Supply only Flairing Nuts of Size 5/8 inch for out door unit of Split type AC of Any make and model.
Supply only Flairing Nuts of Size 1/2 inch for out door unit of Split type AC of Any make and model.
Supply only Flairing Nuts of Size 1/4 inch for out door unit of Split type AC of Any make and model.
Taking down unserviceable Fan Motor of Window / Split type AC 1.5/2.0 TR capacity and of any make and model, removing burnt winding, insulation material, cleaning the surfaces, rewinding the motor with super enameled copper winding wire of same gauge and size including insulation material and varnishing and re-fixing at site all as directed by Eng-in-Charge.
Taking down unserviceable Condenser fan motor of water cooler/refrigerator/deep freezer of any capacity, make and model, removing burnt winding, insulation material, cleaning the surfaces, rewinding the motor with super enameled copper winding wire of same gauge and size including insulation material and varnishing and re-fixing at site all as directed by Eng-in-Charge.
Supply and fixing in repair, Out door Bracket suitable for fixing out door unit of Split type ACs of any make and capacity along with MS clamps, bracings, supports, bolts, nuts & washers, PVC rawl plug etc and making good disturbed surface of wall in CM 1:3 including painting to match with existing surface and all as directed.
Supply and fixing in repair Condenser Fan motor ISI marked of window/split Ac of 1.5 TR / 2 TR capacity of any make and model all as directed.
Supply and fixing in repair Blower Fan motor assembly of indoor unit of split AC 1.5/2TR of any make and model and all as directed.
M/L for carrying out spray painting complete unit of window type AC of any make, model and capacity after dismantling, and painting on sheet metal enclosers interanally and externally with two coats of synthetic enamel paint of approved make and shade after preparation of surface and writing the MES/SM Nos, re-assembling and reconnecting the AC unit at its installed location complete all as directed.
All as per Sl Item No. 2.46 above but for outdoor unit of split AC of any capacity make and model.
Supply and fixing in repair Copper Condenser Coil ISI marked suitable for Window type AC of 1.5/2 TR capacity of any make and model to match with existing design conditions.
Supply and fixing in repair Copper Condesser Coil ISI marked suitable for Split type AC of 1.5 /2.0TR capacity of any make and model to match with existing design conditions.
Supply and fixing in repair Cooling Coil suitable ISI marked for Window type AC of 1.5 TR capacity of any make and model to match with existing design conditions.
Supply and fixing in repair 3 Core 2.5 Sqmm multistrand copper conductor PVC insulated sheathed flexible cable suitable for AC / water cooler / Refrigerator / AC / Voltage stabilizer.
Supply and fixing in repair Electronic Circuit Board Suitable for Out door unit of Split type AC 1.5/2.0 TR (Voltas/Lloyd Inverter model ) and all as per Existing make and model , All as specified and directed by Engr - in - Charge
Supply and fixing in repair Electronic Circuit Board Suitable for Indoor unit of Split type AC 1.5/2.0 TR (Voltas/Lloyd Inverter model ) and all as per Existing make and model , All as specified and directed by Engr - in - Charge
Supply and replacement of compressor for water cooler 40/80 Ltr capacity and assembling and testing the compressor unit complete including taking down all as directed and specified.(Make : DANFOS/ LG/ Kirloskar
Supply and replacement of hermetically sealed reciprocating type compressor for Refrigerator/Deep Freeze 170 to 300 Ltr capacity including taking down. (Make : DANFOS/INDFOS/ LG )
Repair of voltage stabilizer of any capacity ( 1 to 5 KVA) and make, opening up for inspection/checking serviceability of voltage regulating transformer relays, circuit board, voltmeters, incoming/outgoing connections etc and reassembling the same with dismantled component after replacement of burnt spare parts and internal wiring complete all as directed and specified by Engineer-in-Charge. Note. Replacement of spare parts shall be measured and paid separately under items below :-
Supply only transformer of any capacity between 1 to 5 KVA including taking down.
Supply only square/ round type voltmeter of size 2" x 2" for various voltage stabilizers including taking down.
Supply only circuit board for various capacity of stabilizer including taking down.
Supply only 3 way connector for voltage stabilizer including traking down
M &L for Sub main wiring in PVC conduit of required size 2 run of 6 sqmm PVC insulated copper conductor cable wih one run of 6 sqmm PVC insulated copper conductor cable as continuity earth wire, including taking down existing old unsv point wiring , all as speified and directed .
Servicing of Water purifier including replacement of pre Filter and unserviceable components such as PCB and relay , all Filters and membrane, Solenoid-valve and other minor spare parts with connection pipe complete all as directed and specified. (Note : items Such as PCB and relay , all Filters and membrane, Solenoid-valve replaced measured and paid separately. (Make of existing water purifier : Kent, Usha, Aquagard)
Supply only PCB and relay as per existing and all as directed
Supply only all Filters and membrane as per existing and all as directed
Supply only Solenoid valve as per existing and all as directed
Supply only Motor as per existing and all as directed
M/s R.C REFRIGERATION
Bansal And Co
ALLIANCE
ELECTRO COMMERCIAL CO
RPL SYNDICATE CO
RANA ENTERPRISES
DS ENTERPRISES
M/SNeelachal Enterprises
chauhan syndicate
Bidder Name
RANA ENTERPRISES
DS ENTERPRISES
ALLIANCE
RPL SYNDICATE CO
Bansal And Co
M/s R.C REFRIGERATION
MS SHIVA DURGA ENTERPRISES
chauhan syndicate
ELECTRO COMMERCIAL CO
M/SNeelachal Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .