| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹39.0 L+₹65,865 (1.72%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹42.1 L+₹3.8 L (9.96%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹43.0 L+₹4.6 L (12.1%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹43.8 L+₹5.5 L (14.2%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
3 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (UTILITIES) UDHAMPUR
GE (UTILITIES) UDHAMPUR,PO-GARHI,PIN-182121
Repair/Replacement of LT overhead lines, LT cables, stabilizer and switchgears at various pockets in MPH area under GE (Utilities) Udhampur
2022_MES_537800_1
GE/U-28/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (UTILITIES) UDHAMPUR
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (UTILITIES) UDHAMPUR
₹90,000
Yes
20 Sept 2022
13 Jul 2022
5 Aug 2022
13 Jul 2022
3 Aug 2022
27 Jul 2022
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for foundations of poles/stays etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-Charge.
Supply,Laying and fixing in replacement along the poles or passing through pipes or laid under floor etc jointing and testing LT Cross Linked Polythene Insulated(XLPE insulated) galvanized steel strip armoured electric cable 1100 volt grade heavy duty of size 25 sqmm 4 core ISI marked with aluminium conductor and overall served with an outer sheath of PVC, including taking down complete all as specified and directed by Engr-in-Charge. Note : Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection shall be measured and paid for separately.
All as per serial item No. 04 here-in-before but of size 35 sqmm 3.5 core.
All as per serial item No. 04 here-in-before but of size 50 sqmm 3.5 core.
All as per serial item No. 04 here-in-before but of size 70 sqmm 3.5 core.
All as per serial item No. 04 here-in-before but of size 95 sqmm 3.5 core.
All as per serial item No. 04 here-in-before but of size 120 sqmm 3.5 core.
All as per serial item No. 04 here-in-before but of size 150 sqmm 3.5 core.
All as per serial item No. 04 here-in-before but of size 185 sqmm 3.5 core.
All as per serial item No. 04 here-in-before but of size 300 sqmm 3.5 core.
All as per serial item No. 04 here-in-before but of size 400 sqmm 3.5 core.
All as per serial item No. 04 here-in-before but of size 630 sqmm single core.
Supply, install, testing and commissioning of testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compartmentalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 2 mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming:- (a) ACB 800 amps, fixed type manual jod 4 pole, 50Hz ,415 V with rupturing capacity 50 KA-01 No. Make :- L&T, Legrand, Scheineider, Havells, ABB,C&S. (b) Bus bar electrolytic grade copper 1000Amp,4 pole, not less than 1.5 Mtr long SMC insulators mounted on insulators - 01 set.
Outgoing:- (a) MCCB 315/320 amps, 4 pole, 35/36 KA , with adjustable thermal over load release 50 Hz, 415 volts grade - 02 Nos. Make :- &T, Legrand, Scheineider, Havells, ABB,C&S (b) MCCB 250 amps, 4 pole,35/36 KA with adjustable thermal over load release 50 Hz, 415 volts grade - 2 Nos. Make :- &T, Legrand, Scheineider, Havells, ABB,C&S Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using suitable gun metal /SS glands.
All as above items No -5 here-in-before but but of following capacity:- Incoming:- (a) Bus bar electrolytic grade copper 600 Amp,4 pole, not less than 1.5 Mtr long SMC insulators mounted on insulators - 01 set. (b) MCCB FP, 400 Amp, 50 KA -01 No. Make:-H&T, Legrand, Scheineider, Havells, ABB,C&S Outgoing:- (a) MCCB TPN, 315 Amp , 36 KA-01No. Make: L&T, Legrand, Scheineider, Havells, ABB,C&S. (b) MCCB TPN, 250 Amp , 36 KA-01No. Make:- L&T, Legrand, Scheineider, Havells, ABB,C&S. (c) MCCB TPN, 200 Amp , 36 KA -01 No. Make:- L&T, Legrand, Scheineider, Havells, ABB,C&S. (d) MCCB 160 Amp, 4 pole , 25 KA - 01 No. Make: L&T, Legrand, Scheineider, Havells, ABB,C&S. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using suiotable gun metal /SS glands.
All as above items No -5 here-in-before but but of following capacity:- Incoming:- (a) Copper bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 400 amps for phases and neutral - 01 set. (b) On load change over switches 4 pole of capacity 400 Amps -01 No. Note:- Provision has to be made during fabrication for utilisation of change over supply both ends which ever required. Outgoing:- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -03 Nos.
All as above items No -5 here-in-before but but of following capacity:- Incoming:- (a) Copper bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 200 amps for phases and neutral - 01 set. (b) On load change over switches 4 pole of capacity 100 Amps -01 No. Note:-Provision has to be made during fabrication for utilisation of change over supply both ends which ever required. Outgoing:- (a) MCCB 4 pole ,Ics=100%Icu- 25 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos.
LT panel out door (Kiosk type) type, weather & vermin proof MS sheet housing 2 mm thick, powder coated over a coat of primer, double door, front & rear openable type, mounted on 40x40x6 mm angle iron frame, floor mounted type with one MCCB, 4 pole, 100 Amp, 25 KA 415 volts as incomer, copper bus bar 200 Amp of length not less than 60 cm, 4 pole duly drilled with holes for cable connections, after due approval of panel drawing including PCC pedestals of suitable size,Including taking down old unserviceable LT Panel complete all as specified and directed by Engr-in-Charge.
LT panel out door (Kiosk type) type, weather & vermin proof MS sheet housing 2 mm thick, powder coated over a coat of primer, double door, front & rear openable type, mounted on 40x40x6 mm angle iron frame, floor mounted type with, Onload Changeover , 4 pole, 200 Amp, 35 KA 415 volts as incomer, copper bus bar 200 Amp of length not less than 60 cm, 4 pole duly drilled with holes for cable connections, after due approval of panel drawing including PCC pedestals of suitable size,Including taking down old unserviceable LT Panel complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning of testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compartmentalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 2 mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following accessories :- Incoming:- (a) MCCB 320 amps, fixed type manual jod 4 pole, 50Hz ,415 V with rupturing capacity 35 KA-01 No. Make :- L&T, Legrand, Scheineider, Havells, ABB,C&S. (b) Bus bar electrolytic grade Aluminium 600 Amp,4 pole, SMC insulators mounted on insulators - 01 set.
Outgoing:- (a) MCCB 160 amps, 4 pole, 25/26 KA , with adjustable thermal over load release 50 Hz, 415 volts grade - 02 Nos. Make :- L&T, Legrand, Scheineider, Havells, ABB,C&S. (b) MCCB 100 amps, 4 pole,25/26 KA with adjustable thermal over load release 50 Hz, 415 volts grade - 2 Nos. Make :- L&T, Legrand, Scheineider, Havells, ABB,C&S. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using suiotable gun metal /SS glands.
Opening, maintenance and general servicing of Servo voltage stablizers of different makes (Rating from 100 KVA to 400 KVA) including removal of sludge from disserstate coils, Buck Boost Transfromers, tightening of all nut bolts, cleaning of stablizer coils, checking and servicing of servo mechanism, gear synchronising system, automatice voltage regulator circuits and other allied electrical components complete all as specified and directed by Engr-in-Charge. Note:- Rate quoted by contractor is inclusive of following items:- (a) Shifting of stablizer from AOR of CPH to workshop (To/Fro). (b) OEM Service engineer shall be engage for rectification of defects.
Servo Motor with RC Net work (in replacement) having torque of 3 Kg/cm as per existing make complete all as specified and directed by Engr-in-Charge.
Servo Motor with RC Net work(in replacement) having torque of 10 Kg/cm as per existing make complete all as specified and directed by Engr-in-Charge.
Electronic Control Card ( in replacement) for Automatic Voltage regulation as per existing make complete all as specified and directed by Engr-in-Charge.
Top up of transformer oil (ISI Marked) suitable for existing voltage stablizer as per IS 335 part-1 complete all as specified and directed by Engr-in-Charge.
Voltmeter of capacity 0-500 volt ( in replacement) for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
Ammmeter CT operated (in replacement ) for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
Rewinding of variac coil conforming to the original specifications of the servo stablizer of any make/capacity with super enamelled copper wire/strip or DPC copper wire of appropriate gauge and turns including allied materials complete all as specified and directed by Engr-in-Charge.
Circuit plate of capacity 30 KVA-400 KVA (in replacement) for voltage stablizer of any capacity and size as per existing make complete all as specified and directed by Engr-in-Charge.
Pulse transformer of capacity 30 KVA-400 KVA (in replacement ) for voltage stablizer of any capacity and size as per existing make complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanized steel earth plate electrode 600 mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32 x 6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40 x 40 x 5 mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by the Engr-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
Taking down carefully old unserviceable insulator (any type/size) from existing over head lines complete all as specified and directed by Engr-in-Charge.
ACSR conductor of required size for over head lines on poles including streching,tighting of poles insulator with binding wire of sutable size with insulator/streching of ACSR conductor, including taking down old unserviceable ACSR conductors complete all as specified and directed by Engr-in-Charge.
Insulator pin type porcelain viterous white, brown or green LT 1100 Volt including 01 galvanized M.S.spindle, two galvanised iron washers and one galvanized. iron nut of size 100mmx65mm complete all as specified and directedby Engineer-in-Charge.
Shackle type insulator pocelain viterous LT 1100 Volt 100x115mm including M.S. strip washers, insulator bolts, nuts, all as specified and directed by Engineer-in-Charge.
Boring for laying of cable/pipe and making good the disturbed/excavated surface as per existing road including refilling the excavated material, compacting, WBM and black top carpeting with bitumen & aggregate following the stone/sand on top complete all as specified and directed by Engr-in-Charge.
Steel water Tubing 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads of 80mm bore complete all as specified and directed by Engr-in-Charge.
All as per serial item No 28 here-in-before but of size 50mm bore.
All as per serial item No 28 here-in-before but of size 100mm bore.
Dismantling, re-errecting,restringing tensioning and repair to overhead line ACSR conductor of any size upto 5 conductor in one span as required on poles LT / HT including fixing insulators and jointing with ACSR conductor complete all as specified and directed by Engr-in-Charge.
Lopping/prooning of tree branches upto the extend to obtain clearance all around the HT/LT over head lines conductor upto 3 mtr from farthest conductor on pole including removing of cut branches & cleaning of site complete all as specified and directed by Engr-in-Charge. Note:- (a) The trees branches etc will be left as it is & will not be carried away by the contractor/DEL as the wood belongs to CEO/DEO & they will be responsible to lift the wood. (b) Pruning of all tree branches in one tree shall be measured as one Job. (c ) Contractor will employ sufficient labour to complete the Job with in time as directed. (d) Contractor will provide all safety measures to the personel employed by him for this Job and in care of any failure due to hot providing the safety measures, contractor shall be fully responsible for any type of mis-happening/accident while pruning the trees. (e) Contractor/his supervisor will take proper shut down from MES installation before starting the work & clear it before resuming power supply. However, full assistance will be provided by MES staff. (f) The contractor will provide proper tools & safety to his staff for purning of trees.
Straight through joint kit, heat shrinkable type suitable for 70 sqmm LT UG Cable complete all as specified and directed by Engr-in-Charge.
Straight through joint kit, heat shrinkable type suitable for 95 sqmm LT UG Cable complete all as specified and directed by Engr-in-Charge.
Straight through joint kit, heat shrinkable type suitable for 120 to 150 sqmm LT UG Cable complete all as specified and directed by Engr-in-Charge.
Straight through joint kit, heat shrinkable type suitable for 185 sqmm LT UG Cable complete all as specified and directed by Engr-in-Charge.
Disconnecting & taking out the existing Unserviceable MCCB from panel and S&F new MCCB 63 amp, 25 KA breaking capacity of suitable frame size, 4 Pole, 415 V, 50 Hz, 3 phase including extension terminals and connecting using suitable fasteners, modification/fabrication if any complete all as required at site, complete all as specified and directed by Engr-in-Charge.
All as per serial item No 37 here-in-before but of capacity 100 amp, 25 KA.
All as per serial item No 37 here-in-before but of capacity 125 amp, 25 KA.
All as per serial item No 37 here-in-before but of capacity 160 amp, 25 KA.
All as per serial item No 37 here-in-before but of capacity 200 amp, 35/36 KA.
All as per serial item No 37 here-in-before but of capacity 250 amp, 35/36 KA.
All as per serial item No 37 here-in-before but of capacity 320 amp, 35/36 KA.
All as per serial item No 37 here-in-before but of capacity 400 amp, 35/36 KA.
Aluminium thimble cable (Lugs) suitable for Cable of size 25 Sqmm complete all as specified and directed by Engr-in-Charge.
All as per serial item No 45.00 here-in-before but of size 35 Sqmm.
All as per serial item No 45.00 here-in-before but of size 50 Sqmm.
All as per serial item No 45.00 here-in-before but of size 70 Sqmm.
All as per serial item No 45.00 here-in-before but of size 95 Sqmm.
All as per serial item No 45.00 here-in-before but of size 120 Sqmm.
All as per serial item No 45.00 here-in-before but of size 150 Sqmm.
All as per serial item No 45.00 here-in-before but of size 185 Sqmm.
All as per serial item No 45.00 here-in-before but of size 240 Sqmm.
All as per serial item No 45.00 here-in-before but of size 300 Sqmm.
All as per serial item No 45.00 here-in-before but of size 400 Sqmm.
Steel tubular swaged poles erected to truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to Pole, B-118 finial taper cap, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the end portion embedded in concrete, making five black and white bands at lower portion of pole above ground level/coping each 300 mm wide alternately and marking pole number. with black paint at suitable height all as specified and directed by Engineer-in-Charge. Note:- The earthwork, PCC foundation, steel clamps, MS Cross arms & bracing of angle iron etc will be measured and paid separately under relevant items of Sch ‘A’ (BOQ).
Plain cement concrete, M-10(1:3:6), type C-2,(using 40 mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and directed by Engr-in-Charge.
Plain cement concrete, M-15(1:2:4), type B-1 (using 20 mm graded stone aggregate) for coping of poles complete all as specified and directed by Engr-in-Charge.
Stay assembly for LT steel tubular poles comprising of 7/10 SWG galvanized MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FI clamps bolts, nuts, washers, galvanized steel stay rod 16mm dia 180 cm long bow 400x14mm nuts/bolts, washers all galvanized and two nos thimble, loop insulator of size 65x90mm vitreous, clearance dia of hole 16mm, stayplate of size 230x230x6mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate in foundation and disposal of surplus spoil upto 50 M all as specified and shown in plate No 1 of MES SSR Pt -I, complete all as specified and directed by Engr-in-Charge.
Supply ,fabricating and fixing in repairs cross arms ( any type) supports, bracing, stiffeners anti climbing spikes etc made out of MS channel, angle iron, flat of any size including drilling of holes making clamps including eye hooks, nuts bolts and washers etc welding if required including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Painting to steel tubular swaged pole of Overhead lines (9 Mtr long) complete with and including comprising the following works :- (a) Scraping out wornout old paint and making the surface smooth. (b) Painting the pole and all MS work mounted on pole with two coats of synthetic enameled paint (Aluminium shade) as directed by Engr.-in-Charge. (c) Forming five nos coloured bands at lower portion of pole each 300 mm wide alternatively with white and black colour (or any colour as approved by Engr-in-Charge)synthetic enameled paint and marking pole no. with black and white paint complete all as specified by Engr-in-Charge.
Suply only PVC insulation tape red,yellow, blue colour 25 mm 35 mtr length tape Roll complete as specified and directed by Engr-in-Charge.
LT Line spacers rigid type 5 wire complete all as specified and directed by Engr-in-Charge. Make : Pactil/Atlas/Raychem (RPG)/Jaipuria.
Double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as spd and directed by Engr-in-Charge.
Double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as spd and directed by Engr-in-Charge.
Surface cleaning by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, weeds by excavation not exceeding 30cm and averaging 15cm deep including sweeping removing the same to distance not exceeding 50m away from the installation and burning the same all as specified and directed by Engr-in-Charge.
ARNABH ASSOCIATES
FANGALIA TRADERS
MOHAN LAL AND SONS
D P ASSOCIATES
proach associates
M/S RAJINDER GOODS TRANSPORT CARRIER
K S BUILDERS
slathia construction works
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .