| 1 | L1₹2.9 CrAccepted-AOC 402 C WING BUILDING NO 86 NAVRANG CO OP HSG SOCIETY LTD TILAKNAGAR CHEMBUR MUMBAI 89 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400089 | ₹2.9 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹2.9 Cr+₹2.2 L (0.75%)Rejected-Finance | ₹2.9 Cr+₹2.2 L (0.75%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹3.1 Cr+₹22.4 L (7.72%)Rejected-Finance 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | ₹3.1 Cr+₹22.4 L (7.72%) | L3 | Rejected-Finance Not Lowest |
| 4 | Rejected-Technical H NO 49 54 9 2 2 1 OPP MOURYA APPT NEAR VELAMA BHAVAN B S LAYOUT SEETHAMMADHARA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | - | - | Rejected-Technical Firm applied as un-enlisted firm and have not submitted documents in support of enlistment criteria in A class |
| Sl No | Description | Qty | Unit | STANDARD AGENCIES L3 | Sri Associates L2 | Sai construction & services L1 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling galvanised steel sheet roof including ridges, hips, valleys and gutters etc; and stacking the materials with 50 metres lead complete all as specified and directed. | 8 | SQUARE METRE | 49 ₹392 | 25 ₹200 | 10 ₹80 Lowest |
| 2.00 | S&F, pre-painted galvalume aluminium profile sheet zinc coating AZ-150, 240 Mpa, sheet shall be 0.50 mm thick of any colour having tensile strength of 550 mpa, durable and fine finish, high resistant to corrosion as in roof covering fixed with self tapping screws complete all as specified and directed. | 8 | SQUARE METRE | 999 ₹7,992 | 720 ₹5,760 Lowest | 750 ₹6,000 |
| 3.00 | Providing and spray applying two component hybrid polyurea polyureathane waterproofing system at all levels for terrace waterproofing by the manufacturer or his approved applicator consisting the following operations (Horizontal Surfaces):
(a) Dismantling and removing the existing APP layer alongwith protective screed of concrete if any including disposal of malba.
(b) Grinding the surface to remove clinged APP layer and dirt, dust & grease etc; and treating the surface as recommended by manufacturer and there after treated cracks, holes etc; with surface polymer modified cement mortor and ponded with water for 24 hrs for testing of leakage or seepage. | 1,800 | SQUARE METRE | 2,797 ₹50,34,600 | 2,300 ₹41,40,000 | 1,525 ₹27,45,000 Lowest |
| 3.01(c) Providing and applying by spray or brush two component solvent free rasin / epoxy primer mixed in proportion by volume / weight as recommended by manufacturer over cement concrete surface after 14 days having consumption from 0.20 to 0.40 Kg/Sqm depending on the porosity and undulations of the surface. (d) Providing and sprinkling sand as recommended by manufacturer over freshly laid primed tacky surface @ 0.25 to 0.4 Kg/Sqm as decided by the Engineer-in-Charge. | ||||||
| 3.02(e) Over sandy surface providing and spray applying two component hybrid polyurea polyureathane coating system. Solvent free mixed in proportion by volume / weight as recommended by the manufacturer having elongation > 400%. Shore A Hardness > 75 (after 28 days). Tensile stregth of minimum of 10 MPa as per DIN/ASTM and tear strength of minimum 30 N/mm as per DIN 53515 or minimum 45 N/mm as per ASTM D624 and having dry film thickness of two coats shall be minimum 1.5 mm and 20 sec maximum gel time / reaction time. (f) A layer of non woven polypropylene geo textile of minimum mass / unit area of 120 gsm with an overlap of 50 mm shall be laid over the polyurea / polyureathane coating surface having minimum tensile strength 2.4 KN/m as per ASTM. | ||||||
| 3.03(g) Providing and laying screed of cement concrete, 1:1.5:3 using 20mm graded aggregate of thickness 50mm. | ||||||
| 4.00 | Providing and spray applying two component hybrid polyurea polyureathane waterproofing system at all levels for terrace waterproofing by the manufacturer or his approved applicator consisting the following operations (Vertical surfaces i.e. upward roof facias / parapet wall):
(a) Dismantling the existing cement plaster / APP treated vertical surface including disposal of malba.
(b) 15 mm thick cement plaster with cement mortor 1:3 over a coat of cement slurry @ 2 Kg/Sqm.
(c) Providing and laying coving in concave shape of cement concrete 1:1.5:3 using 20 mm graded aggregate of size 75 x 75 mm at the junction of vertical wall and horizontal surfaces along the length of wall. | 160 | SQUARE METRE | 2,690 ₹4,30,400 | 2,300 ₹3,68,000 | 1,547 ₹2,47,520 Lowest |
| 4.01(d) Providing and applying by spray or brush two component solvent free resin / epoxy primer mixed in proportion by volume / weight as recommended by manufacturer over cement concrete surface in dry condition, having consumption from 0.20 to 0.40 Kg/Sqm depending on the porosity and undulations of the surface. (e) Providing and sprinkling washed coarse sand as recommended by manufacturer over freshly laid primed tacky surface @ 0.4 to 0.5 Kg/Sqm as decided by the Engineer-in-Charge. | ||||||
| 4.02(f) Over sandy surface providing and spray applying two component hybrid polyurea polyureathane coating system. Solvent free mixed in proportion by volume / weight as recommended by the manufacturer having elongation > 400%. Shore A Hardness > 75 (after 28 Days). Tensile stregth of minimum of 10 MPa as per DIN/ASTM and tear strength of minimum 30 N/mm as per DIN 53515 or minimum 45 N/mm as per ASTM D624 and having dry film thickness of two coats shall be minimum 1.5 mm and 20 sec maximum gel time / reaction time. | ||||||
| 5.00 | Renewing glass pane with putty, glazing clips and nails wherever necessary at building height of 10mtr, the old putty including float glass panes of nominal thickness 5mm (weight not less than 12.5 kg/Sqm) complete all as specified and directed. | 15 | SQUARE METRE | 1,399 ₹20,985 | 999 ₹14,985 | 500 ₹7,500 Lowest |
Tender Value
₹3.3 Cr
EMD Value
₹4.0 L
Closing Date
13 Feb 2026, 6:00 pmClosed
CHIEF ENGINEER RND SECUNDERABAD
CHIEF ENGINEER RND SECUNDERABAD PICKET OPP JUBILEE BUS STATION SECUNDERABAD 500003
ADDITION ALTERATION AND SPECIAL REPAIRS TO BLDG No. 41, 44 TO 46, 66, 66A AND 112 IN DMRL, HYDERABAD
2026_MES_748768_1
84047
Open Tender
Civil Works
Item Rate
365 days
KANCHANBAGH HYDERABAD
Class A
category a(i) and b(i)
8 documents required · 8 mandatory
₹2,000
GARRISON ENGINEER I RND KANCHANBAGH HYDERABAD
₹4.0 L
Yes
1 Jul 2026
16 Jan 2026
16 Feb 2026
16 Jan 2026
13 Feb 2026
6 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling galvanised steel sheet roof including ridges, hips, valleys and gutters etc; and stacking the materials with 50 metres lead complete all as specified and directed. | 8 | SQUARE METRE | - | - |
| - | Providing and fixing 0.56mm galvalume colour coated profile sheet with centre to centre pitch of 175mm, depth of 46mm, top crest width of 41mm, bottom valley width of 80mm overall profile width of 1144, cover width 1050mm at all height, levels and locations colour finish galvalume alloy roofing sheets of alloy and dimensions as per IS standard with characteristics of good formability and corrosion resistance complete all as specified and directed. | 8 | SQUARE METRE | - | - |
| - | Providing and spray applying two component hybrid polyurea polyureathane waterproofing system at all levels for terrace waterproofing by the manufacturer or his approved applicator consisting the following operations (Horizontal Surfaces):
(a) Dismantling and removing the existing APP layer alongwith protective screed of concrete if any including disposal of malba. | 1,800 | SQUARE METRE | - | - |
| 3.01 | (b) Grinding the surface to remove clinged APP layer and dirt, dust & grease etc; and treating the surface as recommended by manufacturer and there after treated cracks, holes etc; with surface polymer modified cement mortor and ponded with water for 24 hrs for testing of leakage or seepage.
(c) Providing and applying by spray or brush two component solvent free rasin / epoxy primer mixed in proportion by volume / weight as recommended by manufacturer over cement concrete surface after 14 days having consumption from 0.20 to 0.40 Kg/Sqm depending on the porosity and undulations of the surface. | - | - | - | - |
| 3.02 | (d) Providing and sprinkling sand as recommended by manufacturer over freshly laid primed tacky surface @ 0.25 to 0.4 Kg/Sqm as decided by the Engineer-in-Charge.
(e) Over sandy surface providing and spray applying two component hybrid polyurea polyureathane coating system. Solvent free mixed in proportion by volume / weight as recommended by the manufacturer having elongation > 400%. Shore A Hardness > 75 (after 28 days). Tensile stregth of minimum of 10 MPa as per DIN/ASTM and tear strength of minimum 30 N/mm as per DIN 53515 or minimum 45 N/mm as per ASTM D624 and having dry film thickness of two coats shall be minimum 1.5 mm and 20 sec maximum gel time / reaction time. | - | - | - | - |
| 3.03 | (f) A layer of non woven polypropylene geo textile of minimum mass / unit area of 120 gsm with an overlap of 50 mm shall be laid over the polyurea / polyureathane coating surface having minimum tensile strength 2.4 KN/m as per ASTM.
(g) Providing and laying screed of cement concrete, 1:1.5:3 using 20mm graded aggregate of thickness 30mm. | - | - | - | - |
| - | Providing and spray applying two component hybrid polyurea polyureathane waterproofing system at all levels for terrace waterproofing by the manufacturer or his approved applicator consisting the following operations (Vertical surfaces i.e. upward roof facias / parapet wall):
(a) Dismantling the existing cement plaster / APP treated vertical surface including disposal of malba.
(b) 15 mm thick cement plaster with cement mortor 1:3 over a coat of cement slurry @ 2 Kg/Sqm.
(c) Providing and laying coving in concave shape of cement concrete 1:1.5:3 using 20 mm graded aggregate of size 75 x 75 mm at the junction of vertical wall and horizontal surfaces along the length of wall. | 160 | SQUARE METRE | - | - |
| 4.01 | (d) Providing and applying by spray or brush two component solvent free resin / epoxy primer mixed in proportion by volume / weight as recommended by manufacturer over cement concrete surface in dry condition, having consumption from 0.20 to 0.40 Kg/Sqm depending on the porosity and undulations of the surface.
(e) Providing and sprinkling washed coarse sand as recommended by manufacturer over freshly laid primed tacky surface @ 0.4 to 0.5 Kg/Sqm as decided by the Engineer-in-Charge. | - | - | - | - |
| 4.02 | (f) Over sandy surface providing and spray applying two component hybrid polyurea polyureathane coating system. Solvent free mixed in proportion by volume / weight as recommended by the manufacturer having elongation > 400%. Shore A Hardness > 75 (after 28 Days). Tensile stregth of minimum of 10 MPa as per DIN/ASTM and tear strength of minimum 30 N/mm as per DIN 53515 or minimum 45 N/mm as per ASTM D624 and having dry film thickness of two coats shall be minimum 1.5 mm and 20 sec maximum gel time / reaction time. | - | - | - | - |
| - | Renewing glass pane with putty, glazing clips and nails wherever necessary at building height of 10mtr incluidng racking out the old putty including float glass panes of nominal thickness 5mm (weight not less than 12.5 kg/Sqm) complete all as specified and directed. | 15 | SQUARE METRE | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
84047Tender.pdf
Tender Documents • 1.56 MB
BOQ_838547.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .